{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T15:02:02Z","timestamp":1769958122647,"version":"3.49.0"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T00:00:00Z","timestamp":1769126400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:00:00Z","timestamp":1769904000000},"content-version":"vor","delay-in-days":9,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"DOI":"10.1186\/s12871-026-03623-3","type":"journal-article","created":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T13:15:04Z","timestamp":1769174104000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Extending the safe apnea window: preclinical evaluation of the Turbo\u00ae O\u2082 cap for hypoxia mitigation during difficult intubation"],"prefix":"10.1186","volume":"26","author":[{"given":"Robert B.","family":"Goodwin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chris","family":"Salvino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brion","family":"Benninger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,23]]},"reference":[{"issue":"24","key":"3623_CR1","doi-asserted-by":"publisher","first-page":"2488","DOI":"10.1001\/jama.2021.20781","volume":"326","author":"BE Driver","year":"2021","unstructured":"Driver BE, et al. Effect of use of a Bougie vs endotracheal tube with stylet on successful intubation on the first attempt among critically ill patients undergoing tracheal intubation. JAMA. 2021;326(24):2488\u201397. https:\/\/doi.org\/10.1001\/jama.2021.20781.","journal-title":"JAMA"},{"issue":"3","key":"3623_CR2","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.annemergmed.2011.10.002","volume":"59","author":"SD Weingart","year":"2011","unstructured":"Weingart SD, Levitan RM. Preoxygenation and prevention of desaturation during emergency airway management. Ann Emerg Med. 2011;59(3):165\u201375. https:\/\/doi.org\/10.1016\/j.annemergmed.2011.10.002.","journal-title":"Ann Emerg Med"},{"issue":"3","key":"3623_CR3","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.annemergmed.2015.09.002","volume":"67","author":"JB Bodily","year":"2016","unstructured":"Bodily JB, et al. Incidence and duration of continuously measured oxygen desaturation during emergency department intubation. Ann Emerg Med. 2016;67(3):389\u201395. https:\/\/doi.org\/10.1016\/j.annemergmed.2015.09.002.","journal-title":"Ann Emerg Med"},{"issue":"5","key":"3623_CR4","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1093\/bja\/aer504","volume":"108","author":"GD Simpson","year":"2012","unstructured":"Simpson GD, et al. Tracheal intubation in the critically ill: A Multi-Centre National study of practice and complications. Br J Anaesth. 2012;108(5):792\u20139. https:\/\/doi.org\/10.1093\/bja\/aer504.","journal-title":"Br J Anaesth"},{"issue":"11","key":"3623_CR5","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1513\/AnnalsATS.201805-311OC","volume":"15","author":"AC McKown","year":"2018","unstructured":"McKown AC, et al. Risk factors for and prediction of hypoxemia during tracheal intubation of critically ill adults. Ann Am Thorac Soc. 2018;15(11):1325\u201332. https:\/\/doi.org\/10.1513\/AnnalsATS.201805-311OC.","journal-title":"Ann Am Thorac Soc"},{"key":"3623_CR6","unstructured":"SharpMed LLC. Turbo\u00ae O\u2082 Cap Device Overview and Technical Specification One-Pager. Internal publication; 2022."},{"issue":"2","key":"3623_CR7","doi-asserted-by":"publisher","first-page":"024502","DOI":"10.1115\/1.4062151","volume":"17","author":"C Salvino","year":"2023","unstructured":"Salvino C, et al. Development of an endotracheal tube cap for oxygen delivery during intubation. J Med Devices. 2023;17(2):024502. https:\/\/doi.org\/10.1115\/1.4062151.","journal-title":"J Med Devices"},{"issue":"6","key":"3623_CR8","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1097\/00000542-195911000-00007","volume":"20","author":"MJ Frumin","year":"1959","unstructured":"Frumin MJ, Epstein RM, Cohen G. Apneic oxygenation in man. Anesthesiology. 1959;20(6):789\u201398. https:\/\/doi.org\/10.1097\/00000542-195911000-00007.","journal-title":"Anesthesiology"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-026-03623-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-03623-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-03623-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T00:44:40Z","timestamp":1769906680000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12871-026-03623-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,23]]},"references-count":8,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3623"],"URL":"https:\/\/doi.org\/10.1186\/s12871-026-03623-3","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,23]]},"assertion":[{"value":"3 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was conducted at Absorption Systems California, LLC (ASC), a Pharmaron Company. The protocol was approved by ASC\u2019s Institutional Animal Care and Use Committee (IACUC) on March 22, 2022 under IACUC protocol number 22C627Q, and all procedures were conducted in accordance with the National Research Council\u2019s\n                      Guide for the Care and Use of Laboratory Animals\n                      (8th edition) and the AVMA\n                      Guidelines for the Euthanasia of Animals\n                      (2020).Animals were sedated with telazol (4\u20136\u00a0mg\/kg IM) and xylazine (2\u00a0mg\/kg IM) for induction and maintained under continuous deep anesthesia with isoflurane (1\u20133%) throughout all procedures. Depth of anesthesia was confirmed by the absence of corneal and pedal reflexes before each cycle. Following completion of data collection, animals were euthanized while still under deep anesthesia by intravenous administration of potassium chloride (2 mEq\/kg IV).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Chris Salvino is the CEO of SharpMed, LLC, the manufacturer of the Turbo\n                      \u00ae\n                      O\u2082 Cap, and the inventor of the device described in this manuscript. The study was funded by SharpMed, LLC. The other authors (Robert B. Goodwin, DO, and Brion Benninger, MD) declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"78"}}