{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T07:11:33Z","timestamp":1778656293420,"version":"3.51.4"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T00:00:00Z","timestamp":1773100800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":30,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100005713","name":"Technische Universit\u00e4t M\u00fcnchen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100005713","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Pneumoperitoneum and extreme positioning during robotic surgery impose substantial mechanical load on the respiratory system. Whether bedside electrical impedance tomography (EIT) is beneficial for individualized positive end-expiratory pressure (PEEP) titration under routinely high-PEEP ventilation remains uncertain. We assessed the feasibility and benefits of EIT-guided PEEP titration during clinical routine and explored whether pre-EIT respiratory parameters or anthropometric variables can predict EIT-guided best PEEP and EIT endpoints: lung collapse reduction, overdistention reduction, and regional ventilation delay reduction in routine perioperative care.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      Prospective observational study in 177 patients undergoing elective robotic procedures spanning steep Trendelenburg (e.g., prostate\/rectal) and non-Trendelenburg (e.g., adrenalectomy) positions with a laparoscopic pressure of 20 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O. After establishing pneumoperitoneum and final positioning, EIT (OD\u2013CL crossing-point method) was used to titrate PEEP. Primary endpoints were EIT-guided best PEEP and change in PEEP. Secondary endpoints were change in dynamic compliance (Cdyn), driving pressure (DP), and mechanical power (MP) normalized to Cdyn (MP\n                      <jats:sub>adj<\/jats:sub>\n                      ), as well as EIT-derived endpoints: lung collapse reduction, overdistention reduction, and regional ventilation delay reduction. Associations between pre-EIT variables and outcomes were tested by correlations and ROC analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      For the primary endpoints, EIT-guided PEEP increased pre-EIT PEEP from 12.0\u2009\u00b1\u20092.0 to 14.8\u2009\u00b1\u20092.1 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O and, hence, by 2.8\u2009\u00b1\u20092.3 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O. Of the secondary endpoints, Cdyn improved in 82% of the patients after EIT-guided PEEP titration. DP lowered in 31% of the patients, with post-EIT DP of\u2009 \u2264\u200915 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O. Despite mechanical gains, MP\n                      <jats:sub>adj<\/jats:sub>\n                      increased on average from 0.42 to 0.43 J\u00b7cmH\n                      <jats:sub>2<\/jats:sub>\n                      \u200bO\u00b7min\n                      <jats:sup>\u22121<\/jats:sup>\n                      ml\n                      <jats:sup>\u22121<\/jats:sup>\n                      . Concerning the EIT-derived endpoints, lung collapse reduction was 88%, overdistention reduction was 12%, and regional ventilation delay reduction was 30%. Proportions in secondary endpoints did not differ across surgical subgroups. Baseline anthropometrics showed poor predictive value for EIT-guided best PEEP (strongest correlation with MP\n                      <jats:sub>adj<\/jats:sub>\n                      : r\u2009=\u20090.33, R\n                      <jats:sup>2<\/jats:sup>\n                      \u2009=\u20090.109) and change in PEEP (strongest correlation with the difference between laparoscopic pressure and PEEP (lap. pressure-PEEP), r\u2009=\u20090.38; R\n                      <jats:sup>2<\/jats:sup>\n                      \u2009=\u20090.144). Pre-EIT Cdyn best signalled lung collapse reduction with an ROC-derived cutoff\u2009 &lt;\u200945.75 ml\/H\n                      <jats:sub>2<\/jats:sub>\n                      O (accuracy 0.82, sensitivity 0.84, specificity 0.68).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>EIT-guided PEEP titration improved ventilation parameters in a heterogeneous robotic cohort with high abdominal pressure subject to high-PEEP, maintaining lung-protective ventilation. Pre-EIT respiratory data and anthropometric variables were insufficient for the reliable prediction of EIT-guided best PEEP. Our study demonstrates that EIT can be implemented in clinical routine and allows for individualization of respiratory treatment during robotic surgery, subject to high-PEEP ventilation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical trial number<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12871-026-03739-6","type":"journal-article","created":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T11:06:29Z","timestamp":1773140789000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["EIT-guided end-expiratory pressure individualization in robotic surgery with high PEEP ventilation: a prospective observational study"],"prefix":"10.1186","volume":"26","author":[{"given":"Lorenz L.","family":"Mihatsch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anja","family":"Gnadl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fiona","family":"Harzer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"Rederlechner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Friederich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,10]]},"reference":[{"key":"3739_CR1","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1001\/jamasurg.2016.4065","volume":"152","author":"A Fernandez-Bustamante","year":"2017","unstructured":"Fernandez-Bustamante A, Frendl G, Sprung J, Kor DJ, Subramaniam B, Ruiz RM, et al. Postoperative pulmonary complications, early mortality, and hospital stay following noncardiothoracic surgery: a multicenter study by the perioperative research network investigators. JAMA Surg. 2017;152:157\u201366. https:\/\/doi.org\/10.1001\/jamasurg.2016.4065.","journal-title":"JAMA Surg"},{"key":"3739_CR2","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1023\/a:1011491231934","volume":"16","author":"G Hedenstierna","year":"2000","unstructured":"Hedenstierna G, Rothen HU. Atelectasis formation during anesthesia: causes and measures to prevent it. J Clin Monit Comput. 2000;16:329\u201335. https:\/\/doi.org\/10.1023\/a:1011491231934.","journal-title":"J Clin Monit Comput"},{"key":"3739_CR3","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1093\/bja\/82.1.8","volume":"82","author":"G Tusman","year":"1999","unstructured":"Tusman G, B\u00f6hm SH, Anda GFVde, Campo JLdo, Lachmann B. \u2018Alveolar recruitment strategy\u2019 improves arterial oxygenation during general anaesthesia. Br J Anaesth. 1999;82:8\u201313. https:\/\/doi.org\/10.1093\/bja\/82.1.8.","journal-title":"Br J Anaesth"},{"key":"3739_CR4","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1016\/s0140-6736(14)60416-5","volume":"384","author":"PROVE Network Investigators","year":"2014","unstructured":"PROVE Network Investigators. High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): a multicentre randomised controlled trial. Lancet. 2014;384:495\u2013503. https:\/\/doi.org\/10.1016\/s0140-6736(14)60416-5.","journal-title":"Lancet"},{"key":"3739_CR5","doi-asserted-by":"publisher","unstructured":"Bluth T, Neto AS, Schultz MJ, Pelosi P, Abreu MG de, Group PC, et al. Effect of Intraoperative High Positive End-Expiratory Pressure (PEEP) With Recruitment Maneuvers vs Low PEEP on Postoperative Pulmonary Complications in Obese Patients. JAMA. 2019;321:2292\u2013305. https:\/\/doi.org\/10.1001\/jama.2019.7505.","DOI":"10.1001\/jama.2019.7505"},{"key":"3739_CR6","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.12688\/f1000research.125861.1","volume":"11","author":"G Mazzinari","year":"2022","unstructured":"Mazzinari G, Zampieri FG, Ball L, Campos NS, Bluth T, Hemmes SNT, et al. Effect of intraoperative PEEP with recruitment maneuvers on the occurrence of postoperative pulmonary complications during general anesthesia\u2013\u2013protocol for Bayesian analysis of three randomized clinical trials of intraoperative ventilation. F1000Res. 2022;11:1090. https:\/\/doi.org\/10.12688\/f1000research.125861.1.","journal-title":"F1000Res"},{"key":"3739_CR7","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.1016\/j.bja.2022.02.039","volume":"128","author":"NS Campos","year":"2022","unstructured":"Campos NS, Bluth T, Hemmes SNT, Librero J, Pozo N, Ferrando C, et al. Intraoperative positive end-expiratory pressure and postoperative pulmonary complications: a patient-level meta-analysis of three randomised clinical trials. Br J Anaesth. 2022;128:1040\u201351. https:\/\/doi.org\/10.1016\/j.bja.2022.02.039.","journal-title":"Br J Anaesth"},{"key":"3739_CR8","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1186\/s12871-025-03274-w","volume":"25","author":"L Guo","year":"2025","unstructured":"Guo L, Li J, Zhang M, Wu J, Xie C, Lu Y, et al. Driving pressure-guided dynamic PEEP titration reduces atelectasis and improves oxygenation in pediatric laparoscopy: a randomized trial on personalized ventilation strategies. BMC Anesthesiol. 2025;25:412. https:\/\/doi.org\/10.1186\/s12871-025-03274-w.","journal-title":"BMC Anesthesiol"},{"key":"3739_CR9","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1007\/s10877-023-01094-2","volume":"38","author":"T Esposito","year":"2024","unstructured":"Esposito T, Fregonese M, Morettini G, Carboni P, Tardioli C, Messina A, et al. Intraoperative individualization of positive-end-expiratory pressure through electrical impedance tomography or esophageal pressure assessment: a systematic review and meta-analysis of randomized controlled trials. J Clin Monit Comput. 2024;38:89\u2013100. https:\/\/doi.org\/10.1007\/s10877-023-01094-2.","journal-title":"J Clin Monit Comput"},{"key":"3739_CR10","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1016\/j.bja.2019.08.017","volume":"123","author":"CC Young","year":"2019","unstructured":"Young CC, Harris EM, Vacchiano C, Bodnar S, Bukowy B, Elliott RRD, et al. Lung-protective ventilation for the surgical patient: international expert panel-based consensus recommendations. Br J Anaesth. 2019;123:898\u2013913. https:\/\/doi.org\/10.1016\/j.bja.2019.08.017.","journal-title":"Br J Anaesth"},{"key":"3739_CR11","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.bja.2022.07.009","volume":"129","author":"A Zorrilla-Vaca","year":"2022","unstructured":"Zorrilla-Vaca A, Grant MC, Urman RD, Frendl G. Individualised positive end-expiratory pressure in abdominal surgery: a systematic review and meta-analysis. Br J Anaesth. 2022;129:815\u201325. https:\/\/doi.org\/10.1016\/j.bja.2022.07.009.","journal-title":"Br J Anaesth"},{"key":"3739_CR12","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1097\/aln.0000000000003062","volume":"132","author":"A Shono","year":"2020","unstructured":"Shono A, Katayama N, Fujihara T, B\u00f6hm SH, Waldmann AD, Ugata K, et al. Positive end-expiratory pressure and distribution of ventilation in pneumoperitoneum combined with steep Trendelenburg position. Anesthesiology. 2020;132:476\u201390. https:\/\/doi.org\/10.1097\/aln.0000000000003062.","journal-title":"Anesthesiology"},{"key":"3739_CR13","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1097\/aln.0000000000004009","volume":"136","author":"D Lagier","year":"2022","unstructured":"Lagier D, Zeng C, Fernandez-Bustamante A, Melo MFV. Perioperative Pulmonary Atelectasis: Part II. Clinical Implications. Anesthesiology. 2022;136:206\u201336. https:\/\/doi.org\/10.1097\/aln.0000000000004009.","journal-title":"Anesthesiology"},{"key":"3739_CR14","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1186\/s12871-024-02463-3","volume":"24","author":"S Xue","year":"2024","unstructured":"Xue S, Wang D, Tu HQ, Gu XP, Ma ZL, Liu Y, et al. The effects of robot-assisted laparoscopic surgery with Trendelenburg position on short-term postoperative respiratory diaphragmatic function. BMC Anesthesiol. 2024;24:92. https:\/\/doi.org\/10.1186\/s12871-024-02463-3.","journal-title":"BMC Anesthesiol"},{"key":"3739_CR15","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1097\/00000542-200502000-00009","volume":"102","author":"LE Andersson","year":"2005","unstructured":"Andersson LE, B\u00e5\u00e5th M, Th\u00f6rne A, Aspelin P, Odeberg-Wernerman S. Effect of carbon dioxide pneumoperitoneum on development of atelectasis during anesthesia, examined by spiral computed tomography. Anesthesiology. 2005;102:293\u20139. https:\/\/doi.org\/10.1097\/00000542-200502000-00009.","journal-title":"Anesthesiology"},{"key":"3739_CR16","doi-asserted-by":"publisher","unstructured":"Serafini SC, Hemmes SNT, Queiroz VNF, Neto AS, Gregoretti C, Tschernko E, et al. Postoperative Pulmonary Complications in Conventional Laparoscopic vs Robot-Assisted Abdominal Surgery. JAMA Surg. 2025;160. https:\/\/doi.org\/10.1001\/jamasurg.2025.3581.","DOI":"10.1001\/jamasurg.2025.3581"},{"key":"3739_CR17","doi-asserted-by":"publisher","first-page":"1132","DOI":"10.1007\/s00134-009-1447-y","volume":"35","author":"ELV Costa","year":"2009","unstructured":"Costa ELV, Borges JB, Melo A, Suarez-Sipmann F, Toufen C, Bohm SH, et al. Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography. Intensive Care Med. 2009;35:1132\u20137. https:\/\/doi.org\/10.1007\/s00134-009-1447-y.","journal-title":"Intensive Care Med"},{"key":"3739_CR18","doi-asserted-by":"publisher","first-page":"1576","DOI":"10.1007\/s00134-016-4467-4","volume":"42","author":"T Mauri","year":"2016","unstructured":"Mauri T, Eronia N, Turrini C, Battistini M, Grasselli G, Rona R, et al. Bedside assessment of the effects of positive end-expiratory pressure on lung inflation and recruitment by the helium dilution technique and electrical impedance tomography. Intensiv Care Med. 2016;42:1576\u201387. https:\/\/doi.org\/10.1007\/s00134-016-4467-4.","journal-title":"Intensiv Care Med"},{"key":"3739_CR19","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-022-01790-7","volume":"22","author":"M Dargvainis","year":"2022","unstructured":"Dargvainis M, Ohnesorge H, Sch\u00e4dler D, Alkatout I, Frerichs I, Becher T. Recruitable alveolar collapse and overdistension during laparoscopic gynecological surgery and mechanical ventilation: a prospective clinical study. BMC Anesthesiol. 2022;22:251. https:\/\/doi.org\/10.1186\/s12871-022-01790-7.","journal-title":"BMC Anesthesiol"},{"key":"3739_CR20","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1097\/eja.0000000000001901","volume":"40","author":"X Ma","year":"2023","unstructured":"Ma X, Fu Y, Piao X, Santiago RRDS, Ma L, Guo Y, et al. Individualised positive end-expiratory pressure titrated intra-operatively by electrical impedance tomography optimises pulmonary mechanics and reduces postoperative atelectasis. Eur J Anaesthesiol. 2023;40:805\u201316. https:\/\/doi.org\/10.1097\/eja.0000000000001901.","journal-title":"Eur J Anaesthesiol"},{"key":"3739_CR21","doi-asserted-by":"publisher","first-page":"e40357","DOI":"10.1097\/md.0000000000040357","volume":"103","author":"L Chen","year":"2024","unstructured":"Chen L, Yu K, Yang J, Han X, Liu L, Li T, et al. Electrical impedance tomography-guided positive end-expiratory pressure titration for perioperative oxygenation and postoperative pulmonary complications: a systematic review and meta-analysis. Medicine. 2024;103:e40357. https:\/\/doi.org\/10.1097\/md.0000000000040357.","journal-title":"Medicine"},{"key":"3739_CR22","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1097\/eja.0000000000001894","volume":"40","author":"C Boesing","year":"2023","unstructured":"Boesing C, Schaefer L, Schoettler JJ, Quentin A, Beck G, Thiel M, et al. Effects of individualised positive end-expiratory pressure titration on respiratory and haemodynamic parameters during the Trendelenburg position with pneumoperitoneum. Eur J Anaesthesiol. 2023;40:817\u201325. https:\/\/doi.org\/10.1097\/eja.0000000000001894.","journal-title":"Eur J Anaesthesiol"},{"key":"3739_CR23","doi-asserted-by":"publisher","first-page":"2753","DOI":"10.1038\/s41598-023-29860-x","volume":"13","author":"P Buonanno","year":"2023","unstructured":"Buonanno P, Marra A, Iacovazzo C, Merola R, Siena AUD, Servillo G, et al. Electric impedance tomography and protective mechanical ventilation in elective robotic-assisted laparoscopy surgery with steep Trendelenburg position: a randomized controlled study. Sci Rep. 2023;13:2753. https:\/\/doi.org\/10.1038\/s41598-023-29860-x.","journal-title":"Sci Rep"},{"key":"3739_CR24","doi-asserted-by":"publisher","first-page":"7467","DOI":"10.3390\/jcm12237467","volume":"12","author":"M Rauseo","year":"2023","unstructured":"Rauseo M, Spadaro S, Mirabella L, Cotoia A, Laforgia D, Gaudino G, et al. Electrical impedance tomography during abdominal laparoscopic surgery: a physiological pilot study. J Clin Med. 2023;12:7467. https:\/\/doi.org\/10.3390\/jcm12237467.","journal-title":"J Clin Med"},{"key":"3739_CR25","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1097\/mcc.0000000000001255","volume":"31","author":"JE Francovich","year":"2025","unstructured":"Francovich JE, Katira BH, Jonkman AH. Electrical impedance tomography to set positive end-expiratory pressure. Curr Opin Crit Care. 2025;31:319\u201327. https:\/\/doi.org\/10.1097\/mcc.0000000000001255.","journal-title":"Curr Opin Crit Care"},{"key":"3739_CR26","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1186\/s12871-025-03171-2","volume":"25","author":"L Pan","year":"2025","unstructured":"Pan L, Wu X, Gao L, Zhao Z, Yang L, Zhang J. Intraoperative titration of positive end-expiratory pressure in urological patients undergoing laparoscopic procedures under lateral position: a randomized controlled trial. BMC Anesthesiol. 2025;25:311. https:\/\/doi.org\/10.1186\/s12871-025-03171-2.","journal-title":"BMC Anesthesiol"},{"key":"3739_CR27","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/s40635-024-00686-9","volume":"12","author":"JJ Wisse","year":"2024","unstructured":"Wisse JJ, Scaramuzzo G, Pellegrini M, Heunks L, Piraino T, Somhorst P, et al. Clinical implementation of advanced respiratory monitoring with esophageal pressure and electrical impedance tomography: results from an international survey and focus group discussion. Intensiv Care Med Exp. 2024;12:93. https:\/\/doi.org\/10.1186\/s40635-024-00686-9.","journal-title":"Intensiv Care Med Exp"},{"key":"3739_CR28","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1186\/s13054-024-05173-x","volume":"28","author":"G Scaramuzzo","year":"2024","unstructured":"Scaramuzzo G, Pavlovsky B, Adler A, Baccinelli W, Bodor DL, Damiani LF, et al. Electrical impedance tomography monitoring in adult ICU patients: state-of-the-art, recommendations for standardized acquisition, processing, and clinical use, and future directions. Crit Care. 2024;28:377. https:\/\/doi.org\/10.1186\/s13054-024-05173-x.","journal-title":"Crit Care"},{"key":"3739_CR29","first-page":"578","volume":"44","author":"S K\u00e1rason","year":"2000","unstructured":"K\u00e1rason S, S\u00f8ndergaard S, Lundin S, Wiklund J, Stenqvist O. A new method for non-invasive, manoeuvre-free determination of \u201cstatic\u201d pressure-volume curves during dynamic\/therapeutic mechanical ventilation. Acta Anaesthesiol Scand. 2000;44:578\u201385.","journal-title":"Acta Anaesthesiol Scand"},{"key":"3739_CR30","doi-asserted-by":"publisher","first-page":"1052","DOI":"10.1164\/ajrccm.158.4.9801011","volume":"158","author":"W Nikischin","year":"1998","unstructured":"Nikischin W, Gerhardt T, Everett R, Bancalari E. A new method to analyze lung compliance when pressure\u2013volume relationship is nonlinear. Am J Respir Crit Care Med. 1998;158:1052\u201360. https:\/\/doi.org\/10.1164\/ajrccm.158.4.9801011.","journal-title":"Am J Respir Crit Care Med"},{"key":"3739_CR31","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1007\/s00134-019-05636-8","volume":"45","author":"T Becher","year":"2019","unstructured":"Becher T, van der Staay M, Sch\u00e4dler D, Frerichs I, Weiler N. Calculation of mechanical power for pressure-controlled ventilation. Intensive Care Med. 2019;45:1321\u20133. https:\/\/doi.org\/10.1007\/s00134-019-05636-8.","journal-title":"Intensive Care Med"},{"key":"3739_CR32","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1186\/s13054-020-03116-w","volume":"24","author":"D Chiumello","year":"2020","unstructured":"Chiumello D, Gotti M, Guanziroli M, Formenti P, Umbrello M, Pasticci I, et al. Bedside calculation of mechanical power during volume- and pressure-controlled mechanical ventilation. Crit Care. 2020;24:417. https:\/\/doi.org\/10.1186\/s13054-020-03116-w.","journal-title":"Crit Care"},{"key":"3739_CR33","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1097\/aln.0000000000004613","volume":"139","author":"RRDS Santiago","year":"2023","unstructured":"Santiago RRDS, Xin Y, Gaulton TG, Alcala G, Camargo EDLBde, Cereda M, et al. Lung imaging acquisition with electrical impedance tomography: tackling common pitfalls. Anesthesiology. 2023;139:329\u201341. https:\/\/doi.org\/10.1097\/aln.0000000000004613.","journal-title":"Anesthesiology"},{"key":"3739_CR34","doi-asserted-by":"publisher","first-page":"103575","DOI":"10.1016\/j.eclinm.2025.103575","volume":"89","author":"H He","year":"2025","unstructured":"He H, Zhao Z, Becher T, Bellani G, Yoshida T, Amato MBP, et al. Recommendations for lung ventilation and perfusion assessment with chest electrical impedance tomography in critically ill adult patients: an international evidence-based and expert Delphi consensus study. eClinicalMedicine. 2025;89:103575. https:\/\/doi.org\/10.1016\/j.eclinm.2025.103575.","journal-title":"eClinicalMedicine"},{"key":"3739_CR35","doi-asserted-by":"publisher","unstructured":"Karalapillai D, Weinberg L, A SN, Peyton P, Ellard L, Hu R, et al. Intra-operative ventilator mechanical power as a predictor of postoperative pulmonary complications in surgical patients. Eur J Anaesthesiol. 2022;39:67\u201374. https:\/\/doi.org\/10.1097\/eja.0000000000001601.","DOI":"10.1097\/eja.0000000000001601"},{"key":"3739_CR36","doi-asserted-by":"publisher","first-page":"1567","DOI":"10.1007\/s00134-016-4505-2","volume":"42","author":"L Gattinoni","year":"2016","unstructured":"Gattinoni L, Tonetti T, Cressoni M, Cadringher P, Herrmann P, Moerer O, et al. Ventilator-related causes of lung injury: the mechanical power. Intensive Care Med. 2016;42:1567\u201375. https:\/\/doi.org\/10.1007\/s00134-016-4505-2.","journal-title":"Intensive Care Med"},{"key":"3739_CR37","doi-asserted-by":"publisher","first-page":"e70067","DOI":"10.1111\/aas.70067","volume":"69","author":"CM Brandt","year":"2025","unstructured":"Brandt CM, Borgmann S, Frank N, Spaeth J, Hell J, Lozano\u2010Zahonero S, et al. Individualised positive end\u2010expiratory pressure during robotic\u2010assisted radical prostatectomy guided by intratidal compliance\u2013volume curve analysis. Acta Anaesthesiol Scand. 2025;69:e70067. https:\/\/doi.org\/10.1111\/aas.70067.","journal-title":"Acta Anaesthesiol Scand"},{"key":"3739_CR38","doi-asserted-by":"publisher","first-page":"101569","DOI":"10.1016\/j.accpm.2025.101569","volume":"44","author":"G Scaramuzzo","year":"2025","unstructured":"Scaramuzzo G, Priani P, Ferrara P, Verri M, Montanaro F, Rosa RL, et al. Longitudinal changes of electrical impedance tomography-based best PEEP in obese patients undergoing laparoscopic surgery: a prospective physiological study. Anaesthesia Critical Care & Pain Medicine. 2025;44:101569. https:\/\/doi.org\/10.1016\/j.accpm.2025.101569.","journal-title":"Anaesthesia Critical Care & Pain Medicine"},{"key":"3739_CR39","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1097\/mcc.0000000000001121","volume":"30","author":"LS Menga","year":"2024","unstructured":"Menga LS, Subir\u00e0 C, Wong A, Sousa M, Brochard LJ. Setting positive end-expiratory pressure: does the \u2018best compliance\u2019 concept really work? Curr Opin Crit Care. 2024;30:20\u20137. https:\/\/doi.org\/10.1097\/mcc.0000000000001121.","journal-title":"Curr Opin Crit Care"},{"key":"3739_CR40","doi-asserted-by":"publisher","first-page":"1211","DOI":"10.1097\/aln.0000000000005677","volume":"143","author":"T Ros\u00e0","year":"2025","unstructured":"Ros\u00e0 T, Menga LS, Mastropietro C, Settanni D, Russo A, Frassanito L, et al. Evaluation of the potential for lung recruitment with the recruitment-to-inflation ratio during general anesthesia. Anesthesiology. 2025;143:1211\u201324. https:\/\/doi.org\/10.1097\/aln.0000000000005677.","journal-title":"Anesthesiology"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-026-03739-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-03739-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-03739-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T06:35:50Z","timestamp":1778654150000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12871-026-03739-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,10]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3739"],"URL":"https:\/\/doi.org\/10.1186\/s12871-026-03739-6","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,10]]},"assertion":[{"value":"29 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Patients gave written and informed consent to participate in this study prior to inclusion. Ethical approval was waived by the ethical committee of the Bayerische Landes\u00e4rztekammer (Ref. 2020\u20131255) since all data collected were routine and observational in nature and, thus, fall under the provisions of the Bavarian Hospital Act (BayKrG, Art. 27). The study adheres to the Declaration of Helsinki and its later amendments. Clinical trial number was not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"PF received lecturing and consulting fees from Dr\u00e4ger Medical. All other authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"219"}}