{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T08:46:51Z","timestamp":1790412411644,"version":"4.1.0"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:00:00Z","timestamp":1780531200000},"content-version":"vor","delay-in-days":43,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background\/aim<\/jats:title>\n                    <jats:p>Fiberoptic bronchoscopy (FOB) is considered the gold standard for confirming correct placement of left-sided double-lumen tubes (LDLTs) during thoracic anesthesia. However, routine FOB use is not always feasible in high-volume centers, and selective strategies are frequently adopted. This study aimed to identify factors associated with the need for selective intraoperative FOB following conventional LDLT placement in a high-volume thoracic anesthesia practice where FOB is not routinely used.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This retrospective observational study was conducted in a high-volume tertiary thoracic surgery center over a 3.5-year period (July 2017 to January 2021). Adult patients undergoing elective thoracic surgery with LDLT placement were reviewed. FOB was not used routinely and was performed only when clinical findings suggested possible tube malposition. Patients were categorized according to intraoperative FOB requirement. Controls were randomly selected in a 1:2 ratio. Demographic, clinical, surgical, and operator-related variables were evaluated. Binary logistic regression was used to identify independent predictors of FOB requirement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Among 2155 eligible patients, FOB was required in 152 (7.05%); 136 patients with complete data were analyzed. Compared with controls (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009272), patients requiring FOB more frequently had higher body weight, higher body mass index, smaller LDLT size, and procedures performed by less experienced anesthesiologists. In multivariable analysis, anesthesiologist experience remained the only independent predictor of FOB requirement: procedures performed by anesthesiologists with &lt;\u20091 year (OR 6.77; 95% CI 3.66\u201312.52;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) and 1\u20135 years of experience (OR 2.57; 95% CI 1.43\u20134.60;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.001) were associated with increased FOB use. The most common indications for FOB were pressure and\/or volume incompatibility and unexpected desaturation, with malposition most frequently corrected via the tracheal lumen.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In thoracic anesthesia practices where routine FOB is not available, a selective, experience-guided FOB strategy appears appropriate. Anesthesiologist experience is the primary determinant of intraoperative FOB requirement following LDLT placement, whereas patient- and procedure-related factors do not independently predict the need for bronchoscopy. A lower threshold for FOB use should be considered when LDLT placement is performed by less experienced anesthesiologists.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12871-026-03855-3","type":"journal-article","created":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T07:34:37Z","timestamp":1776843277000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Factors associated with selective fiberoptic bronchoscopy use after left double-lumen tube placement"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5534-7579","authenticated-orcid":false,"given":"Onur","family":"K\u00fc\u00e7\u00fck","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2249-6521","authenticated-orcid":false,"given":"Musa","family":"Zengin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1124-7861","authenticated-orcid":false,"given":"Hilal","family":"Sazak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7550-6730","authenticated-orcid":false,"given":"Oya","family":"Kaybal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1926-4770","authenticated-orcid":false,"given":"G\u00fclay","family":"\u00dclger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3661-4277","authenticated-orcid":false,"given":"Ramazan","family":"Baldemir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7968-3462","authenticated-orcid":false,"given":"Mehtap","family":"Tun\u00e7","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-9962-5244","authenticated-orcid":false,"given":"Fatma \u00d6zt\u00fcrk","family":"Yal\u00e7\u0131n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7538-2213","authenticated-orcid":false,"given":"Ali","family":"Alag\u00f6z","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,22]]},"reference":[{"issue":"1","key":"3855_CR1","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1097\/ACO.0b013e3283346c6d","volume":"23","author":"GW Fischer","year":"2010","unstructured":"Fischer GW, Cohen E. An update on anesthesia for thoracoscopic surgery. Curr Opin Anaesthesiol. 2010;23(1):7\u201311.","journal-title":"Curr Opin Anaesthesiol"},{"issue":"6","key":"3855_CR2","doi-asserted-by":"publisher","first-page":"495","DOI":"10.5301\/tj.5000638","volume":"103","author":"F Bernasconi","year":"2017","unstructured":"Bernasconi F, Piccioni F. One-lung ventilation for thoracic surgery: current perspectives. Tumori. 2017;103(6):495\u2013503.","journal-title":"Tumori"},{"issue":"2","key":"3855_CR3","doi-asserted-by":"publisher","first-page":"124","DOI":"10.4103\/aca.aca_140_22","volume":"26","author":"SB Shah","year":"2023","unstructured":"Shah SB, Hariharan U, Chawla R. Choosing the correct-sized adult double-lumen tube: Quest for the holy grail. Ann Card Anaesth. 2023;26(2):124\u201332.","journal-title":"Ann Card Anaesth"},{"issue":"2","key":"3855_CR4","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1097\/00000542-200602000-00010","volume":"104","author":"JH Campos","year":"2006","unstructured":"Campos JH, Hallam EA, Van Natta T, Kernstine KH. Devices for lung isolation used by anesthesiologists with limited thoracic experience: comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker. Anesthesiology. 2006;104(2):261\u20136.","journal-title":"Anesthesiology"},{"issue":"5","key":"3855_CR5","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1007\/s12630-012-9689-5","volume":"59","author":"JS Bussi\u00e8res","year":"2012","unstructured":"Bussi\u00e8res JS, Slinger P. Correct positioning of double-lumen tubes. Can J Anaesth. 2012;59(5):431\u20136.","journal-title":"Can J Anaesth"},{"issue":"2","key":"3855_CR6","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1093\/bja\/aeh055","volume":"92","author":"S Inoue","year":"2004","unstructured":"Inoue S, Nishimine N, Kitaguchi K, Furuya H, Taniguchi S. Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation. Br J Anaesth. 2004;92(2):195\u2013201.","journal-title":"Br J Anaesth"},{"key":"3855_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12871-015-0138-1","volume":"15","author":"JH Seo","year":"2015","unstructured":"Seo JH, Bae JY, Kim HJ, Hong DM, Jeon Y, Bahk JH. Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: incidence, risk factors and blind repositioning techniques. BMC Anesthesiol. 2015;15:1\u20137.","journal-title":"BMC Anesthesiol"},{"issue":"8","key":"3855_CR8","doi-asserted-by":"publisher","first-page":"476","DOI":"10.4103\/0019-5049.162983","volume":"59","author":"SY Parab","year":"2015","unstructured":"Parab SY, Divatia JV, Chogle A. A prospective comparative study to evaluate the utility of lung ultrasonography to improve the accuracy of traditional clinical methods to confirm position of left sided double lumen tube in elective thoracic surgeries. Indian J Anaesth. 2015;59(8):476\u201381.","journal-title":"Indian J Anaesth"},{"issue":"3","key":"3855_CR9","first-page":"1","volume":"94","author":"E Gupta","year":"2023","unstructured":"Gupta E, Singh P, Tejpal Karna S, Niwariya Y, Waindeskar V, Jain S, et al. Comparison of lung ultrasound technique versus clinical method to evaluate the accuracy of size and placement of left endobronchial double lumen tube in patients undergoing elective thoracic surgery: a prospective observational study. Monaldi Arch Chest Dis. 2023;94(3):1\u20137.","journal-title":"Monaldi Arch Chest Dis"},{"key":"3855_CR10","doi-asserted-by":"crossref","unstructured":"Do\u011fan A, Sazak H, Tunc M, Alag\u00f6z A. Effectiveness Thoracic Ultrasonography to Confirm Position of Double Lumen Endobronchial tube. J Cardio-Vascular-Thoracic Anaesth Intensive Care Soc. 2019;25(4):247\u201356.","DOI":"10.5222\/GKDAD.2019.62534"},{"issue":"4","key":"3855_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.heliyon.2023.e15458","volume":"9","author":"PK Wang","year":"2023","unstructured":"Wang PK, Lin TY, Su IM, Chang KV, Wu WT, \u00d6z\u00e7akar L. Preoperative lung ultrasound for confirming the double-lumen endotracheal tube position for one-lung ventilation: A systematic review and meta-analysis. Heliyon. 2023;9(4):1\u20139.","journal-title":"Heliyon"},{"issue":"5","key":"3855_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5812\/aapm-132312","volume":"12","author":"WY Elsabeeny","year":"2022","unstructured":"Elsabeeny WY, Ibrahim MA, Abed SM, Shehab NN. Role of Lung Ultrasound in Confirmation of Double Lumen Endotracheal Tube Placement for Thoracic Surgeries: A Prospective Diagnostic Accuracy Study. Anesth Pain Med. 2022;12(5):1\u20137.","journal-title":"Anesth Pain Med"},{"issue":"1","key":"3855_CR13","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1097\/00001503-200402000-00003","volume":"17","author":"JB Brodsky","year":"2004","unstructured":"Brodsky JB. Fiberoptic bronchoscopy need not be a routine part of double-lumen tube placement. Curr Opin Anaesthesiol. 2004;17(1):7\u201311.","journal-title":"Curr Opin Anaesthesiol"},{"issue":"4","key":"3855_CR14","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1016\/j.ejcts.2011.01.070","volume":"40","author":"M de Bellis","year":"2011","unstructured":"de Bellis M, Accardo R, Di Maio M, La Manna C, Rossi GB, Pace MC, et al. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? Eur J Cardiothorac Surg. 2011;40(4):912\u20136.","journal-title":"Eur J Cardiothorac Surg"},{"issue":"1","key":"3855_CR15","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1097\/ACO.0000000000001586","volume":"39","author":"M Granell Gil","year":"2026","unstructured":"Granell Gil M, Mart\u00ednez Plumed R. Airway management in thoracic anesthesia in the light of the guidelines of EACTAIC-thoracic group: what is next? Curr Opin Anaesthesiol. 2026;39(1):66\u201370.","journal-title":"Curr Opin Anaesthesiol"},{"issue":"7","key":"3855_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/jcm12072473","volume":"12","author":"YW Do","year":"2023","unstructured":"Do YW, Kim JH, Kim K, Oh J, Kwak KH, Jeon Y, et al. Effect of Minimum Bronchial Cuff Volume of Left-Sided Double-Lumen Tube for One-Lung Ventilation on the Change in Bronchial Cuff Pressure during Lateral Positioning in Thoracic Surgery: A Prospective Observational Study. J Clin Med. 2023;12(7):1\u201310.","journal-title":"J Clin Med"},{"issue":"8","key":"3855_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/jcm10081590","volume":"10","author":"JH Kim","year":"2021","unstructured":"Kim JH, Kim E, Kim IY, Choi EJ, Byun SH. Changes in the Bronchial Cuff Pressure of Left-Sided Double-Lumen Endotracheal Tube by Lateral Positioning: A Prospective Observational Study. J Clin Med. 2021;10(8):1\u201310.","journal-title":"J Clin Med"},{"issue":"2","key":"3855_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/07853890.2023.2247422","volume":"55","author":"ZY Chen","year":"2023","unstructured":"Chen ZY, Lin YM, Wu JH, Fu YY, Xu XT, Li Y, et al. Does the periportal end of a double-lumen endobronchial tube need to be fixed to prevent dislocation of the cuffed end caused by a change in position? A randomized controlled trial. Ann Med. 2023;55(2):1\u201310.","journal-title":"Ann Med"},{"issue":"3","key":"3855_CR19","doi-asserted-by":"publisher","first-page":"280","DOI":"10.4103\/sja.sja_192_21","volume":"15","author":"AA Eldawlatly","year":"2021","unstructured":"Eldawlatly AA. Double lumen tube: Size and insertion depth. Saudi J Anaesth. 2021;15(3):280\u20132.","journal-title":"Saudi J Anaesth"},{"issue":"10","key":"3855_CR20","doi-asserted-by":"publisher","first-page":"3903","DOI":"10.21037\/jtd-22-451","volume":"14","author":"P Palaczynski","year":"2022","unstructured":"Palaczynski P, Misiolek H, Bialka S, Owczarek AJ, Gola W, Szarpak \u0141, et al. A randomized comparison between the VivaSight double-lumen tube and standard double-lumen tube intubation in thoracic surgery patients. J Thorac Dis. 2022;14(10):3903\u201314.","journal-title":"J Thorac Dis"},{"issue":"11","key":"3855_CR21","doi-asserted-by":"publisher","first-page":"6533","DOI":"10.21037\/jtd-20-1595","volume":"12","author":"A Onifade","year":"2020","unstructured":"Onifade A, Lemon-Riggs D, Smith A, Pak T, Pruszynski J, Reznik S, et al. Comparing the rate of fiberoptic bronchoscopy use with a video double lumen tube versus a conventional double lumen tube-a randomized controlled trial. J Thorac Dis. 2020;12(11):6533\u201341.","journal-title":"J Thorac Dis"},{"issue":"6","key":"3855_CR22","first-page":"1063","volume":"42","author":"H Sazak","year":"2012","unstructured":"Sazak H, G\u00f6kta\u015f U, Alag\u00f6z A, Demirba\u015f \u00c7S, G\u00fcven \u00d6, \u015eavk\u0131l\u0131o\u011flu E. Comparison of two different right-sided double-lumen tubes with different designs. Turk J Med Sci. 2012;42(6):1063\u20139.","journal-title":"Turk J Med Sci"},{"issue":"3","key":"3855_CR23","doi-asserted-by":"publisher","first-page":"279","DOI":"10.4103\/aca.aca_43_21","volume":"25","author":"M Granell","year":"2022","unstructured":"Granell M, Petrini G, Kot P, Murcia M, Morales J, Guijarro R, et al. Intubation with vivasight double-lumen tube versus conventional double-lumen tube in adult patients undergoing lung resection: A retrospective analysis. Ann Card Anaesth. 2022;25(3):279\u201385.","journal-title":"Ann Card Anaesth"},{"issue":"6","key":"3855_CR24","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1007\/s12630-021-01957-9","volume":"68","author":"J Somma","year":"2021","unstructured":"Somma J, Couture \u00c9J, Pelletier S, Provencher S, Moreault O, Lohser J, et al. Non-ventilated lung deflation during one-lung ventilation with a double-lumen endotracheal tube: a randomized-controlled trial of occluding the non-ventilated endobronchial lumen before pleural opening. Can J Anaesth. 2021;68(6):801\u201311.","journal-title":"Can J Anaesth"},{"issue":"1","key":"3855_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13063-018-3163-9","volume":"20","author":"T Ryu","year":"2019","unstructured":"Ryu T, Kim E, Kim JH, Woo SJ, Roh WS, Byun SH. Comparing the placement of a left-sided double-lumen tube via fiberoptic bronchoscopy guidance versus conventional intubation using a Macintosh laryngoscope, to reduce the incidence of malpositioning: study protocol for a randomized controlled pilot trial. Trials. 2019;20(1):1\u20138.","journal-title":"Trials"},{"issue":"1","key":"3855_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s44158-025-00286-3","volume":"5","author":"M Rispoli","year":"2025","unstructured":"Rispoli M, Calgaro G, Strano G, Rosboch GL, Massullo D, Piccirillo F, et al. Deciding how to decide the correct double-lumen tube: a narrative review of methods and evidence. J Anesth Analg Crit Care. 2025;5(1):1\u201310.","journal-title":"J Anesth Analg Crit Care"},{"issue":"1","key":"3855_CR27","doi-asserted-by":"publisher","first-page":"47","DOI":"10.4103\/aca.ACA_165_18","volume":"24","author":"A Rastogi","year":"2021","unstructured":"Rastogi A. Practice patterns of left-sided double-lumen tube: Does It match recommendation from literature. Ann Card Anaesth. 2021;24(1):47\u20138.","journal-title":"Ann Card Anaesth"},{"issue":"4","key":"3855_CR28","doi-asserted-by":"publisher","first-page":"427","DOI":"10.4103\/aca.aca_24_25","volume":"28","author":"M Kinra","year":"2025","unstructured":"Kinra M, Parab S, Shetmahajan M, Salunke B, Ranganathan P. Practices of Sizing of Left-Sided Double Lumen Tubes at a Tertiary-Referral Cancer Centre in India: A Retrospective Cohort Study. Ann Card Anaesth. 2025;28(4):427\u201331.","journal-title":"Ann Card Anaesth"},{"issue":"2","key":"3855_CR29","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1093\/oxfordjournals.aje.a009786","volume":"149","author":"S Hennessy","year":"1999","unstructured":"Hennessy S, Bilker WB, Berlin JA, Strom BL. Factors influencing the optimal control-to-case ratio in matched case-control studies. Am J Epidemiol. 1999;149(2):195\u20137.","journal-title":"Am J Epidemiol"},{"issue":"2","key":"3855_CR30","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1097\/00000542-199802000-00012","volume":"88","author":"U Klein","year":"1998","unstructured":"Klein U, Karzai W, Bloos F, Wohlfarth M, Gottschall R, Fritz H, et al. Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study. Anesthesiology. 1998;88(2):346\u201350.","journal-title":"Anesthesiology"},{"issue":"1","key":"3855_CR31","doi-asserted-by":"publisher","first-page":"42","DOI":"10.4103\/aca.ACA_93_19","volume":"24","author":"RD Nguyen","year":"2021","unstructured":"Nguyen RD, Kurnutala LN, Tucci MA, Hierlmeier BJ. Comparison of different size left-sided double-lumen tubes for thoracic surgery. Ann Card Anaesth. 2021;24(1):42\u20136.","journal-title":"Ann Card Anaesth"},{"issue":"1","key":"3855_CR32","first-page":"1","volume":"14","author":"G Cui","year":"2024","unstructured":"Cui G, Zhao L, Chi C, Liang S, Liu Z. The feasibility and accuracy of the method for selecting the optimal size of double-lumen tube in thoracic surgery: a prospective, randomized controlled trial. Sci Rep. 2024;14(1):1\u20137.","journal-title":"Sci Rep"},{"key":"3855_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jclinane.2015.12.030","volume":"32","author":"G Zani","year":"2016","unstructured":"Zani G, Stefano M, Tommaso BF, Marco R, Salvatore B, Antonio C, et al. How clinical experience leads anesthetists in the choice of double-lumen tube size. J Clin Anesth. 2016;32:1\u20133.","journal-title":"J Clin Anesth"},{"issue":"1","key":"3855_CR34","first-page":"1","volume":"9","author":"F Piccioni","year":"2020","unstructured":"Piccioni F, Droghetti A, Bertani A, Coccia C, Corcione A, Corsico AG, et al. Recommendations from the Italian intersociety consensus on Perioperative Anesthesia Care in Thoracic surgery (PACTS) part 1: preadmission and preoperative care. Perioper Med (Lond). 2020;9(1):1\u201317.","journal-title":"Perioper Med (Lond)"},{"issue":"3","key":"3855_CR35","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1097\/EJA.0b013e328340c332","volume":"28","author":"JH Campos","year":"2011","unstructured":"Campos JH, Hallam EA, Ueda K. Training in placement of the left-sided double-lumen tube among non-thoracic anaesthesiologists: intubation model simulator versus computer-based digital video disc, a randomised controlled trial. Eur J Anaesthesiol. 2011;28(3):169\u201374.","journal-title":"Eur J Anaesthesiol"},{"issue":"3","key":"3855_CR36","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1093\/oxfordjournals.bja.a013430","volume":"84","author":"SH Pennefather","year":"2000","unstructured":"Pennefather SH, Russell GN. Placement of double lumen tubes\u2013time to shed light on an old problem. Br J Anaesth. 2000;84(3):308\u201310.","journal-title":"Br J Anaesth"},{"issue":"11","key":"3855_CR37","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1111\/anae.13177","volume":"70","author":"D Levy-Faber","year":"2015","unstructured":"Levy-Faber D, Malyanker Y, Nir RR, Best LA, Barak M. Comparison of VivaSight double-lumen tube with a conventional double-lumen tube in adult patients undergoing video-assisted thoracoscopic surgery. Anaesthesia. 2015;70(11):1259\u201363.","journal-title":"Anaesthesia"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-026-03855-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-03855-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-03855-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T22:32:46Z","timestamp":1781649166000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12871-026-03855-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,22]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3855"],"URL":"https:\/\/doi.org\/10.1186\/s12871-026-03855-3","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,22]]},"assertion":[{"value":"21 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"342"}}