{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:50:23Z","timestamp":1792086623340,"version":"4.4.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:00:00Z","timestamp":1784592000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T00:00:00Z","timestamp":1792022400000},"content-version":"vor","delay-in-days":86,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Anesthesiol"],"DOI":"10.1186\/s12871-026-04115-0","type":"journal-article","created":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T07:57:17Z","timestamp":1784620637000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Peripherally inserted central catheters versus central venous catheters in critically ill patients under standardized insertion protocols: a propensity score\u2013matched cohort study"],"prefix":"10.1186","volume":"26","author":[{"given":"Xiaofang","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiujuan","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiajia","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiong","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changguang","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Niankai","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chongjing","family":"Mu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,21]]},"reference":[{"issue":"1","key":"4115_CR1","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1177\/1129729820928618","volume":"22","author":"RJ Smith","year":"2021","unstructured":"Smith RJ, Cartin-Ceba R, Colquist JA, Muir AM, Moorhead JM, Callisen HE, Patel BM. Peripherally inserted central catheter placement in a multidisciplinary intensive care unit: A preliminary study demonstrating safety and procedural time in critically ill subjects. J Vasc Access Jan. 2021;22(1):101\u20136.","journal-title":"J Vasc Access Jan"},{"key":"4115_CR2","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1002\/jhm.13093","volume":"18","author":"E Bredenberg","year":"2023","unstructured":"Bredenberg E, Atwater R, Grimm E, Chopra V, Dale Shamburger C, Anstett TJ. Promoting appropriate midline catheter and PICC placement through implementation of an EHR-based clinical decision support tool: An interrupted time-series analysis. J Hosp Med. 2023;18:483\u201390.","journal-title":"J Hosp Med"},{"key":"4115_CR3","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ijnurstu.2017.03.001","volume":"71","author":"SL Krein","year":"2017","unstructured":"Krein SL, Kuhn L, Ratz D, Winter S, Vaughn VM, Chopra V. The relationship between perceived role and appropriate use of peripherally inserted central catheters: A survey of vascular access nurses in the United States. Int J Nurs Stud. 2017;71:28\u201333.","journal-title":"Int J Nurs Stud"},{"key":"4115_CR4","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1080\/17434440.2024.2346191","volume":"21","author":"T Takahashi","year":"2024","unstructured":"Takahashi T, Morita K, Uda K, Matsui H, Yasunaga H, Nakagami G. Complications after peripherally inserted central catheter versus central venous catheter implantation in intensive care unit: propensity score analysis using a nationwide database. Expert Rev Med Devices. 2024;21:447\u201353.","journal-title":"Expert Rev Med Devices"},{"key":"4115_CR5","doi-asserted-by":"crossref","unstructured":"Chopra V, Flanders SA, Saint S, Woller SC, O\u2019Grady NP, Safdar N, Trerotola SO, Saran R, Moureau N, Wiseman S, Pittiruti M, Akl EA, Lee AY, Courey A, Swaminathan L, LeDonne J, Becker C, Krein SL, Bernstein SJ. Michigan Appropriateness Guide for Intravenouse Catheters (MAGIC) Panel. The Michigan Appropriateness Guide for Intravenous Catheters (MAGIC): Results From a Multispecialty Panel Using the RAND\/UCLA Appropriateness Method. Ann Intern Med. 2015;163(6 Suppl).","DOI":"10.7326\/M15-0744"},{"issue":"4","key":"4115_CR6","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1177\/11297298211048019","volume":"24","author":"F Pinelli","year":"2023","unstructured":"Pinelli F, Little A, Kokotis K, Alsbrooks K, Pittiruti M. Assessment of the MAGIC recommendations in context of evolving evidence based on the use of PICC in ICU. J Vasc Access Jul. 2023;24(4):836\u201347.","journal-title":"J Vasc Access Jul"},{"issue":"2","key":"4115_CR7","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1177\/11297298211036002","volume":"24","author":"F Brescia","year":"2023","unstructured":"Brescia F, Pittiruti M, Ostroff M, Spencer TR, Dawson RB. The SIC protocol: A seven-step strategy to minimize complications potentially related to the insertion of centrally inserted central catheters. J Vasc Access Mar. 2023;24(2):185\u201390.","journal-title":"J Vasc Access Mar"},{"issue":"1","key":"4115_CR8","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1177\/11297298221099838","volume":"25","author":"F Brescia","year":"2024","unstructured":"Brescia F, Pittiruti M, Spencer TR, Dawson RB. The SIP protocol update: Eight strategies, incorporating Rapid Peripheral Vein Assessment (RaPeVA), to minimize complications associated with peripherally inserted central catheter insertion. J Vasc Access Jan. 2024;25(1):5\u201313.","journal-title":"J Vasc Access Jan"},{"issue":"1","key":"4115_CR9","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1177\/1129729819852203","volume":"21","author":"P Balsorano","year":"2020","unstructured":"Balsorano P, Virgili G, Villa G, Pittiruti M, Romagnoli S, De Gaudio AR, Pinelli F. Peripherally inserted central catheter-related thrombosis rate in modern vascular access era-when insertion technique matters: A systematic review and meta-analysis. J Vasc Access Jan. 2020;21(1):45\u201354.","journal-title":"J Vasc Access Jan"},{"issue":"1","key":"4115_CR10","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1177\/1129729820916113","volume":"22","author":"GJ Schears","year":"2021","unstructured":"Schears GJ, Ferko N, Syed I, Arpino JM, Alsbrooks K. Peripherally inserted central catheters inserted with current best practices have low deep vein thrombosis and central line-associated bloodstream infection risk compared with centrally inserted central catheters: A contemporary meta-analysis. J Vasc Access Jan. 2021;22(1):9\u201325.","journal-title":"J Vasc Access Jan"},{"issue":"4","key":"4115_CR11","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1177\/11297298241262932","volume":"26","author":"F Pinelli","year":"2025","unstructured":"Pinelli F, Pittiruti M, Annetta MG, Barbani F, Bertoglio S, Biasucci DG, Bolis D, Brescia F, Capozzoli G, D\u2019Arrigo S, Deganello E, Elli S, Fabiani A, Fabiani F, Gidaro A, Giustivi D, Iacobone E, La Greca A, Longo F, Lucchini A, Marche B, Romagnoli S, Scoppettuolo G, Selmi V, Vailati D, Villa G, Pepe G. A GAVeCeLT consensus on the indication, insertion, and management of central venous access devices in the critically ill. J Vasc Access Jul. 2025;26(4):1096\u2013114.","journal-title":"J Vasc Access Jul"},{"issue":"15","key":"4115_CR12","doi-asserted-by":"publisher","first-page":"1527","DOI":"10.1001\/jama.2012.12704","volume":"17","author":"V Chopra","year":"2012","unstructured":"Chopra V, Flanders SA, Saint S. The problem with peripherally inserted central catheters. JAMA Oct. 2012;17(15):1527\u20138.","journal-title":"JAMA Oct"},{"issue":"9889","key":"4115_CR13","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/S0140-6736(13)60592-9","volume":"27","author":"V Chopra","year":"2013","unstructured":"Chopra V, Anand S, Hickner A, Buist M, Rogers MA, Saint S, Flanders SA. Risk of venous thromboembolism associated with peripherally inserted central catheters: a systematic review and meta-analysis. Lancet Jul. 2013;27(9889):311\u201325.","journal-title":"Lancet Jul"},{"issue":"8","key":"4115_CR14","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/j.amjmed.2012.04.010","volume":"125","author":"V Chopra","year":"2012","unstructured":"Chopra V, Anand S, Krein SL, Chenoweth C, Saint S. Bloodstream infection, venous thrombosis, and peripherally inserted central catheters: reappraising the evidence. Am J Med Aug. 2012;125(8):733\u201341.","journal-title":"Am J Med Aug"},{"issue":"1","key":"4115_CR15","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.jcrc.2015.09.024","volume":"31","author":"ME Nolan","year":"2016","unstructured":"Nolan ME, Yadav H, Cawcutt KA, Cartin-Ceba R. Complication rates among peripherally inserted central venous catheters and centrally inserted central catheters in the medical intensive care unit. J Crit Care. Feb; 2016;31(1):238\u201342.","journal-title":"J Crit Care"},{"key":"4115_CR16","doi-asserted-by":"publisher","first-page":"917572","DOI":"10.3389\/fcvm.2022.917572","volume":"26","author":"A Puri","year":"2022","unstructured":"Puri A, Dai H, Giri M, Wu C, Huang H, Zhao Q. The incidence and risk of venous thromboembolism associated with peripherally inserted central venous catheters in hospitalized patients: A systematic review and meta-analysis. Front Cardiovasc Med Jul. 2022;26:9:917572.","journal-title":"Front Cardiovasc Med Jul"},{"issue":"6","key":"4115_CR17","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1016\/j.hrtlng.2020.07.008","volume":"49","author":"G Mavrovounis","year":"2020","unstructured":"Mavrovounis G, Mermiri M, Chatzis DG, Pantazopoulos I. Peripherally Inserted Central Catheter lines for Intensive Care Unit and onco-hematologic patients: A systematic review and meta-analysis. Heart Lung Nov-Dec. 2020;49(6):922\u201333.","journal-title":"Heart Lung Nov-Dec"},{"key":"4115_CR18","doi-asserted-by":"crossref","unstructured":"Dobrescu A, Constantin AM, Pinte L, Chapman A, Ratajczak P, Klerings I, Emprechtinger R, Allegranzi B, Grayson ML, Toledo JP, Gartlehner G, Nussbaumer-Streit B. (2025) Effectiveness and safety of methods to prevent bloodstream and other infections and noninfectious complications associated with peripherally inserted central catheters: A systematic review and meta-analysis. Clin Infect Dis. 2025:ciaf063.","DOI":"10.1093\/cid\/ciaf063"},{"issue":"5","key":"4115_CR19","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1001\/jamainternmed.2023.8232","volume":"184","author":"B Teja","year":"2024","unstructured":"Teja B, Bosch NA, Diep C, Pereira TV, Mauricio P, Sklar MC, Sankar A, Wijeysundera HC, Saskin R, Walkey A, Wijeysundera DN, Wunsch H. Complication rates of central venous catheters: a systematic review and meta-analysis. JAMA Intern Med. 2024;184(5):474\u201382.","journal-title":"JAMA Intern Med"},{"issue":"7","key":"4115_CR20","doi-asserted-by":"publisher","first-page":"e045895","DOI":"10.1136\/bmjopen-2020-045895","volume":"5","author":"R Sharp","year":"2021","unstructured":"Sharp R, Carr P, Childs J, Scullion A, Young M, Flynn T, Kirker C, Jackson G, Esterman A. Catheter to vein ratio and risk of peripherally inserted central catheter (PICC)-associated thrombosis according to diagnostic group: a retrospective cohort study. BMJ Open Jul. 2021;5(7):e045895.","journal-title":"BMJ Open Jul"},{"issue":"5","key":"4115_CR21","doi-asserted-by":"publisher","first-page":"e0300425","DOI":"10.1371\/journal.pone.0300425","volume":"19","author":"TCDC Silva","year":"2024","unstructured":"Silva TCDC, Braga LM, Vieira Junior JM. Risk of deep venous thrombosis associated with peripherally inserted central catheter: a retrospective cohort study of 11.588 catheters in Brazil. PLoS ONE. 2024;19(5):e0300425.","journal-title":"PLoS ONE"}],"container-title":["BMC Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-026-04115-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-04115-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12871-026-04115-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:32:54Z","timestamp":1792085574000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12871-026-04115-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,21]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4115"],"URL":"https:\/\/doi.org\/10.1186\/s12871-026-04115-0","relation":{},"ISSN":["1471-2253"],"issn-type":[{"value":"1471-2253","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,21]]},"assertion":[{"value":"11 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was conducted in accordance with the Declaration of Helsinki and was approved by the Institutional Ethics Committee of The Affiliated Suzhou Hospital of Nanjing Medical University. Owing to the retrospective nature of the study and the use of anonymized clinical data, the requirement for informed consent to participate was waived by the Institutional Ethics Committee of The Affiliated Suzhou Hospital of Nanjing Medical University.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"621"}}