{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,13]],"date-time":"2026-01-13T01:03:05Z","timestamp":1768266185263,"version":"3.49.0"},"reference-count":5,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,9,23]],"date-time":"2021-09-23T00:00:00Z","timestamp":1632355200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,9,23]],"date-time":"2021-09-23T00:00:00Z","timestamp":1632355200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Leadless pacemaker has been acknowledged as a promising pacing strategy to prevent pocket and lead-related complications. Although rare, cardiac perforation remains a major safety concern for implantation of Micra transcatheter pacing system (TPS).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 83-year-old female with low body mass index (18.9\u00a0kg\u00a0m<jats:sup>\u22122<\/jats:sup>) on dual anti-platelet therapy, was indicated for Micra TPS implantation due to sinus arrest and paroxysmal atrial flutter. The patient developed mild pericardial effusion during the procedure since the delivery catheter was accidentally placed into the coronary sinus for several times. Cardiac perforation with moderate pericardial effusion and pericardial tamponade was detected 2\u00a0h post-procedure. The patient was treated with immediately pericardiocentesis and recovered without further invasive therapy.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Pericardial effusion caused by accidently placing a delivery catheter into the coronary sinus is rare but should be carefully considered in Micra TPS implantation, especially for those with periprocedural anti-platelet therapy.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12872-021-02266-1","type":"journal-article","created":{"date-parts":[[2021,9,23]],"date-time":"2021-09-23T23:05:23Z","timestamp":1632438323000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Pericardial effusion caused by accidently placing a Micra transcatheter pacing system into the coronary sinus"],"prefix":"10.1186","volume":"21","author":[{"given":"Xueying","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingfeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yixiu","family":"Liang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4724-1541","authenticated-orcid":false,"given":"Yangang","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junbo","family":"Ge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,9,23]]},"reference":[{"issue":"12","key":"2266_CR1","doi-asserted-by":"publisher","first-page":"1800","DOI":"10.1016\/j.hrthm.2018.08.005","volume":"15","author":"MF El-Chami","year":"2018","unstructured":"El-Chami MF, Al-Samadi F, Clementy N, Garweg C, Martinez-Sande JL, Piccini JP, Iacopino S, Lloyd M, Vi\u00f1olas Prat X, Jacobsen MD, Ritter P, Johansen JB, Tondo C, Liu F, Fagan DH, Eakley AK, Roberts PR. Updated performance of the Micra transcatheter pacemaker in the real-world setting: a comparison to the investigational study and a transvenous historical control. Heart Rhythm. 2018;15(12):1800\u20137.","journal-title":"Heart Rhythm"},{"key":"2266_CR2","doi-asserted-by":"publisher","first-page":"1375","DOI":"10.1016\/j.hrthm.2017.05.017","volume":"14","author":"PR Roberts","year":"2017","unstructured":"Roberts PR, Clementy N, Al Samadi F, et al. A leadless pacemaker in the real-world setting: the Micra transcatheter pacing system post approval registry. Heart Rhythm. 2017;14:1375\u20139.","journal-title":"Heart Rhythm"},{"key":"2266_CR3","doi-asserted-by":"publisher","first-page":"2604","DOI":"10.1056\/NEJMoa1511643","volume":"374","author":"DW Reynolds","year":"2016","unstructured":"Reynolds DW, Ritter P. A leadless intracardiac transcatheter pacing system. N Engl J Med. 2016;374:2604\u20135.","journal-title":"N Engl J Med"},{"issue":"6","key":"2266_CR4","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1016\/j.hrthm.2018.12.007","volume":"16","author":"JJ Hai","year":"2019","unstructured":"Hai JJ, Fang J, Tam CC, Wong CK, Un KC, Siu CW, Lau CP, Tse HF. Safety and feasibility of a midseptal implantation technique of a leadlesspacemaker. Heart Rhythm. 2019;16(6):896\u2013902.","journal-title":"Heart Rhythm"},{"issue":"3","key":"2266_CR5","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1002\/joa3.12052","volume":"34","author":"I Togashi","year":"2018","unstructured":"Togashi I, Sato T, Hoshida K, Soejima K. Subclinical cardiac perforation caused by a MicraTM leadless pacemaker. J Arrhythm. 2018;34(3):326\u20138.","journal-title":"J Arrhythm"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-021-02266-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-021-02266-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-021-02266-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,23]],"date-time":"2021-09-23T23:09:06Z","timestamp":1632438546000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-021-02266-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,23]]},"references-count":5,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2266"],"URL":"https:\/\/doi.org\/10.1186\/s12872-021-02266-1","relation":{},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,23]]},"assertion":[{"value":"8 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The patient has given a written consent of anonymous use of the clinical data for academic use, research purposes and publications.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images. A copy of the written consent form is available.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"461"}}