{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T01:18:50Z","timestamp":1793150330928,"version":"4.5.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T00:00:00Z","timestamp":1632182400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T00:00:00Z","timestamp":1632182400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Spinal artery ischemia (SCI) events can result from over coverage of the descending thoracic aorta with a coated stent during Thoracic Endovascular Aortic Repair (TEVAR). The aim of this study was to determine whether a new distal perforating stent could reduce the incidence of spinal cord ischemia while remodeling the true lumen.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>TBAD patients treated with Talos stent in the vascular surgery Department of Yan 'an Hospital affiliated to Kunming Medical University between December 2017 and October 2019 were retrospectively analyzed to investigate the short-term safety and effectiveness of Talos stent.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A total of the 20 patients, including 14 males and 6 females, with an average age of 52.65\u2009\u00b1\u20098.98\u00a0years (range 37\u201368\u00a0years), were included in the analysis. Stent-grafts were successfully implanted in all patients under local anesthesia, with a technical success rate of 100%. The average operation time was 50.75\u2009\u00b1\u200913.01\u00a0min. A total of 2 cases (10%) presented chest pain associated with intercostal artery ischemia that was relieved on the 3rd and 5th postoperative day, respectively. Postoperative mean follow-up was 16.15\u2009\u00b1\u20093.99\u00a0months. No paraplegia or other complications occurred. And stenting did not induce new tears. No migration, deformation, or fracture of the stents occurred. There was a significant difference in the remolding of the true lumen preoperatively and at 12\u00a0months postoperatively (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Talos stent has achieved satisfactory clinical treatment results in short term.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12872-021-02270-5","type":"journal-article","created":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T13:03:09Z","timestamp":1632229389000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["The short-term safety and effectiveness of a new distal perforating stent graft in Type B aortic dissection: a retrospective study"],"prefix":"10.1186","volume":"21","author":[{"given":"Xunqiang","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenkai","family":"Ji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanjun","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cuihong","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liqiong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jifeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Ji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunxin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enshuai","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Cong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xili","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaona","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hailong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaping","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Tan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jinhui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,9,21]]},"reference":[{"key":"2270_CR1","first-page":"251","volume":"20","author":"W Mo","year":"2014","unstructured":"Mo W, Wang W, Zhou X. Clinical observation of endovascular exclusion in the treatment of elderly patients with acute Stanford type B aortic dissection. J Intern Intensive Med. 2014;20:251\u20132.","journal-title":"J Intern Intensive Med"},{"key":"2270_CR2","first-page":"147","volume":"16","author":"J Ge","year":"2019","unstructured":"Ge J, Zhang Q, Zhang Y. A case of paraplegia after Stanford type B aortic dissection thoracic endovascular aortic repair and literature review. China Med Herald. 2019;16:147\u201350.","journal-title":"China Med Herald"},{"key":"2270_CR3","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/j.ejvs.2007.11.005","volume":"35","author":"P Amabile","year":"2008","unstructured":"Amabile P, Grisoli D, Giorgi R, Bartoli JM, Piquet P. Incidence and determinants of spinal cord ischaemia in stent-graft repair of the thoracic aorta. Eur J Vasc Endovasc Surg. 2008;35:455\u201361. https:\/\/doi.org\/10.1016\/j.ejvs.2007.11.005.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2270_CR4","first-page":"471","volume":"57","author":"YM Li","year":"2019","unstructured":"Li YM, Zhang L, Zhou J, Jing ZP. Advances in the effects on false lumen thrombosis after the endovascular treatment of aortic dissection and its intervention strategies. Chin J Surg. 2019;57:471\u20135.","journal-title":"Chin J Surg"},{"key":"2270_CR5","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1024\/0301-1526\/a000704","volume":"47","author":"D Siti","year":"2018","unstructured":"Siti D, Abudesimu A, Ma X, Yang L, Ma X, Ma YT. Incidence and risk factors of recurrent pain in acute aortic dissection and in-hospital mortality. Vasa. 2018;47:301\u201310. https:\/\/doi.org\/10.1024\/0301-1526\/a000704.","journal-title":"Vasa"},{"key":"2270_CR6","doi-asserted-by":"publisher","unstructured":"Hiratzka LF, Bakris GL, Beckman JA, Bersin RM, Carr VF, Casey DE, Jr., et al. ACCF\/AHA\/AATS\/ACR\/ASA\/SCA\/SCAI\/SIR\/STS\/SVM Guidelines for the diagnosis and management of patients with thoracic aortic disease. A Report of the American College of Cardiology Foundation\/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology,American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons,and Society for Vascular Medicine. J Am Coll Cardiol. 2010;55:e27-e129; https:\/\/doi.org\/10.1016\/j.jacc.2010.02.015.","DOI":"10.1016\/j.jacc.2010.02.015"},{"key":"2270_CR7","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1016\/j.ejvs.2013.08.017","volume":"46","author":"N Diehm","year":"2013","unstructured":"Diehm N, Vermassen F, van Sambeek MR. Standardized definitions and clinical endpoints in trials investigating endovascular repair of aortic dissections. Eur J Vasc Endovasc Surg. 2013;46:645\u201350. https:\/\/doi.org\/10.1016\/j.ejvs.2013.08.017.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2270_CR8","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1016\/j.jvs.2016.09.033","volume":"65","author":"AV Kamman","year":"2017","unstructured":"Kamman AV, Brunkwall J, Verhoeven EL, Heijmen RH, Trimarchi S. Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database. J Vasc Surg. 2017;65:964-71.e3. https:\/\/doi.org\/10.1016\/j.jvs.2016.09.033.","journal-title":"J Vasc Surg"},{"key":"2270_CR9","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1177\/1526602817712511","volume":"24","author":"M Piazza","year":"2017","unstructured":"Piazza M, Squizzato F, Miccoli T, Lepidi S, Menegolo M, Grego F, et al. Definition of type II endoleak risk based on preoperative anatomical characteristics. J Endovasc Ther. 2017;24:566\u201372. https:\/\/doi.org\/10.1177\/1526602817712511.","journal-title":"J Endovasc Ther"},{"key":"2270_CR10","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1016\/j.jtcvs.2017.11.088","volume":"155","author":"RD Qi","year":"2018","unstructured":"Qi RD, Zhu JM, Liu YM, Chen L, Li CN, Xing XY, et al. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure. J Thorac Cardiovasc Surg. 2018;155:1391\u20136. https:\/\/doi.org\/10.1016\/j.jtcvs.2017.11.088.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2270_CR11","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1016\/j.ejvs.2015.04.035","volume":"50","author":"H He","year":"2015","unstructured":"He H, Yao K, Nie WP, Wang Z, Liang Q, Shu C, et al. Modified petticoat technique with pre-placement of a distal bare stent improves early aortic remodeling after complicated acute stanford type B aortic dissection. Eur J Vasc Endovasc Surg. 2015;50:450\u20139. https:\/\/doi.org\/10.1016\/j.ejvs.2015.04.035.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"2270_CR12","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.jvs.2011.10.025","volume":"55","author":"G Melissano","year":"2012","unstructured":"Melissano G, Bertoglio L, Rinaldi E, Civilini E, Tshomba Y, Kahlberg A, et al. Volume changes in aortic true and false lumen after the \u201cPETTICOAT\u201d procedure for type B aortic dissection. J Vasc Surg. 2012;55:641\u201351. https:\/\/doi.org\/10.1016\/j.jvs.2011.10.025.","journal-title":"J Vasc Surg"},{"key":"2270_CR13","first-page":"114","volume":"22","author":"F Yang","year":"2014","unstructured":"Yang F, Luo J. A systematic evaluation of the efficacy of a coated stent combined with the bare-metal stent in the treatment of B-type aortic dissection. Chin J Interv Cardiol. 2014;22:114\u20136.","journal-title":"Chin J Interv Cardiol"},{"key":"2270_CR14","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.athoracsur.2011.06.106","volume":"93","author":"SC Hofferberth","year":"2012","unstructured":"Hofferberth SC, Foley PT, Newcomb AE, Yap KK, Yii MY, Nixon IK, et al. Combined proximal endografting with distal bare-metal stenting for management of aortic dissection. Ann Thorac Surg. 2012;93:95\u2013102. https:\/\/doi.org\/10.1016\/j.athoracsur.2011.06.106.","journal-title":"Ann Thorac Surg"},{"key":"2270_CR15","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1016\/j.jtcvs.2008.06.021","volume":"136","author":"G Melissano","year":"2008","unstructured":"Melissano G, Bertoglio L, Kahlberg A, Baccellieri D, Marrocco-Trischitta MM, Calliari F, et al. Evaluation of a new disease-specific endovascular device for type B aortic dissection. J Thorac Cardiovasc Surg. 2008;136:1012\u20138. https:\/\/doi.org\/10.1016\/j.jtcvs.2008.06.021.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2270_CR16","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1007\/s00595-017-1588-5","volume":"48","author":"T Sueda","year":"2018","unstructured":"Sueda T, Takahashi S. Spinal cord injury as a complication of thoracic endovascular aneurysm repair. Surg Today. 2018;48:473\u20137. https:\/\/doi.org\/10.1007\/s00595-017-1588-5.","journal-title":"Surg Today"},{"key":"2270_CR17","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1016\/j.jvs.2017.05.082","volume":"66","author":"M Alsawas","year":"2017","unstructured":"Alsawas M, Zaiem F, Larrea-Mantilla L, Almasri J, Erwin PJ, Upchurch GR Jr, et al. Effectiveness of surgical interventions for thoracic aortic aneurysms: a systematic review and meta-analysis. J Vasc Surg. 2017;66:1258-68.e8. https:\/\/doi.org\/10.1016\/j.jvs.2017.05.082.","journal-title":"J Vasc Surg"},{"key":"2270_CR18","first-page":"641","volume":"93","author":"W Fu","year":"2013","unstructured":"Fu W, Yue J. Strategy of spinal cord ischemia after thoracic aortic endovascular repair. Natl Med J China. 2013;93:641\u20133.","journal-title":"Natl Med J China"},{"key":"2270_CR19","doi-asserted-by":"crossref","unstructured":"Feezor RJ, Martin TD, Hess PJ, Daniels MJ, Beaver TM, Klodell CT et al. Extent of aortic coverage and incidence of spinal cord ischemia after thoracic endovascular aneurysm repair. Ann Thorac Surg. 2008;86:1809\u201314.","DOI":"10.1016\/j.athoracsur.2008.09.022"},{"key":"2270_CR20","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1148\/rg.235025031","volume":"23","author":"K Yoshioka","year":"2003","unstructured":"Yoshioka K, Niinuma H, Ohira A, Nasu K, Kawakami T, Sasaki M, et al. MR angiography and CT angiography of the artery of Adamkiewicz: noninvasive preoperative assessment of thoracoabdominal aortic aneurysm. Radiographics. 2003;23:1215\u201325. https:\/\/doi.org\/10.1148\/rg.235025031.","journal-title":"Radiographics"},{"key":"2270_CR21","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1016\/j.jvs.2010.05.121","volume":"52","author":"Z Dong","year":"2010","unstructured":"Dong Z, Fu W, Wang Y, Wang C, Yan Z, Guo D, et al. Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection. J Vasc Surg. 2010;52:1450\u20137. https:\/\/doi.org\/10.1016\/j.jvs.2010.05.121.","journal-title":"J Vasc Surg"},{"key":"2270_CR22","first-page":"599","volume":"30","author":"S Zhang","year":"2015","unstructured":"Zhang S, Feng J, Lu Q. Restrictive bare stent for thoracic endovascular aortic repair in type B aortic dissection. Chin J Gen Surg. 2015;30:599\u2013603.","journal-title":"Chin J Gen Surg"},{"key":"2270_CR23","first-page":"926","volume":"28","author":"J Feng","year":"2013","unstructured":"Feng J, Lu Q, Zhao Z, Bao J, Feng X, Feng R, et al. Restrictive bare stent prevents stent-graft induced distal re-dissection after TEVAR for type B aortic dissection. Chin J Gen Surg. 2013;28:926\u201330.","journal-title":"Chin J Gen Surg"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-021-02270-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-021-02270-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-021-02270-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,21]],"date-time":"2021-09-21T13:04:38Z","timestamp":1632229478000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-021-02270-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,21]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2270"],"URL":"https:\/\/doi.org\/10.1186\/s12872-021-02270-5","relation":{},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,21]]},"assertion":[{"value":"29 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors are accountable for all aspects of the work in ensuring that questions related to the accuracy or integrity of any part of the work are appropriately investigated and resolved. This retrospective analysis was approved by the Ethics Committee of Drug Clinical Trial in Yan'an Hospital, Kunming Medical University (IRB-PJ-2017-003). Informed consent for the use of a novel stent during treatment (Talos stent) and for the analysis of data published in the study was obtained from all the patients. All methods were performed in accordance with the relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"457"}}