{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,8,11]],"date-time":"2023-08-11T10:53:08Z","timestamp":1691751188476},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T00:00:00Z","timestamp":1638835200000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5\u00b0 change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13\/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48\/77) of BAV patients needed less than 5\u00b0 change to achieve optimal projection and only in 8 patients, the angular change was larger than 10\u00b0 in either left\/right anterior oblique or cranial\/caudal direction.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12872-021-02387-7","type":"journal-article","created":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T12:03:26Z","timestamp":1638878606000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A CT-based technique to predict optimal projection for self-expanding TAVI in patients with different aortic valve anatomies"],"prefix":"10.1186","volume":"21","author":[{"given":"Xi","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tian-Yuan","family":"Xiong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi-Jian","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan-Weixiang","family":"Ou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiao","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia-Fu","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sen","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan","family":"Feng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,7]]},"reference":[{"key":"2387_CR1","doi-asserted-by":"publisher","first-page":"e009407","DOI":"10.1161\/CIRCINTERVENTIONS.120.009407","volume":"14","author":"Y Sammour","year":"2021","unstructured":"Sammour Y, Banerjee K, Kumar A, Lak H, Chawla S, Incognito C, et al. Systematic approach to high implantation of SAPIEN-3 valve achieves a lower rate of conduction abnormalities including pacemaker implantation. Circ Cardiovasc Interv. 2021;14:e009407.","journal-title":"Circ Cardiovasc Interv"},{"key":"2387_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jcct.2018.11.008","volume":"13","author":"P Blanke","year":"2019","unstructured":"Blanke P, Weir-McCall JR, Achenbach S, Delgado V, Hausleiter J, Jilaihawi H, et al. Computed tomography imaging in the context of transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR): an expert consensus document of the Society of Cardiovascular Computed Tomography. J Cardiovasc Comput Tomogr. 2019;13:1\u201320.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2387_CR3","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1016\/j.jcin.2010.09.010","volume":"3","author":"R Gurvitch","year":"2010","unstructured":"Gurvitch R, Wood DA, Leipsic J, Tay E, Johnson M, Ye J, et al. Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2010;3:1157\u201365.","journal-title":"JACC Cardiovasc Interv"},{"key":"2387_CR4","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.jcct.2012.10.008","volume":"6","author":"M Arnold","year":"2012","unstructured":"Arnold M, Achenbach S, Pfeiffer I, Ensminger S, Marwan M, Einhaus F, et al. A method to determine suitable fluoroscopic projections for transcatheter aortic valve implantation by computed tomography. J Cardiovasc Comput Tomogr. 2012;6:422\u20138.","journal-title":"J Cardiovasc Comput Tomogr"},{"key":"2387_CR5","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1093\/ehjci\/jex183","volume":"18","author":"MM Hell","year":"2017","unstructured":"Hell MM, Biburger L, Marwan M, Schuhbaeck A, Achenbach S, Lell M, et al. Prediction of fluoroscopic angulations for transcatheter aortic valve implantation by CT angiography: influence on procedural parameters. Eur Heart J Cardiovasc Imaging. 2017;18:906\u201314.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"key":"2387_CR6","doi-asserted-by":"publisher","first-page":"2079","DOI":"10.1093\/eurheartj\/ehp260","volume":"30","author":"P Schoenhagen","year":"2009","unstructured":"Schoenhagen P, Tuzcu EM, Kapadia SR, Desai MY, Svensson LG. Three-dimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair\/implantation. Eur Heart J. 2009;30:2079\u201386.","journal-title":"Eur Heart J"},{"key":"2387_CR7","doi-asserted-by":"publisher","first-page":"1663","DOI":"10.1016\/j.jcin.2018.03.018","volume":"11","author":"GHL Tang","year":"2018","unstructured":"Tang GHL, Zaid S, Michev I, Ahmad H, Kaple R, Undemir C, et al. \u201cCusp-Overlap\u201d view simplifies fluoroscopy-guided implantation of self-expanding valve in transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2018;11:1663\u20135.","journal-title":"JACC Cardiovasc Interv"},{"key":"2387_CR8","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.jcin.2020.10.022","volume":"14","author":"I Wong","year":"2021","unstructured":"Wong I, Bieliauskas G, De Backer O, S\u00f8ndergaard L. Technical considerations for transcatheter aortic valve replacement with ACURATE neo2. JACC Cardiovasc Interv. 2021;14:224\u20136.","journal-title":"JACC Cardiovasc Interv"},{"key":"2387_CR9","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1016\/j.jcin.2020.10.033","volume":"14","author":"J Ben-Shoshan","year":"2021","unstructured":"Ben-Shoshan J, Alosaimi H, Lauzier PT, Pighi M, Talmor-Barkan Y, Overtchouk P, et al. Double S-curve versus cusp-overlap technique: defining the optimal fluoroscopic projection for TAVR with a self-expanding device. JACC Cardiovasc Interv. 2021;14:185\u201394.","journal-title":"JACC Cardiovasc Interv"},{"key":"2387_CR10","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1161\/CIRCULATIONAHA.120.048048","volume":"143","author":"F Vincent","year":"2021","unstructured":"Vincent F, Ternacle J, Denimal T, Shen M, Redfors B, Delhaye C, et al. Transcatheter aortic valve replacement in bicuspid aortic valve stenosis. Circulation. 2021;143:1043\u201361.","journal-title":"Circulation"},{"key":"2387_CR11","doi-asserted-by":"publisher","first-page":"S45","DOI":"10.1093\/ejcts\/ezs533","volume":"42","author":"AP Kappetein","year":"2012","unstructured":"Kappetein AP, Head SJ, G\u00e9n\u00e9reux P, Piazza N, van Mieghem NM, Blackstone EH, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012;42:S45-60.","journal-title":"Eur J Cardiothorac Surg"},{"key":"2387_CR12","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1016\/j.jtcvs.2007.01.039","volume":"133","author":"H-H Sievers","year":"2007","unstructured":"Sievers H-H, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg. 2007;133:1226\u201333.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2387_CR13","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1016\/j.cpcardiol.2010.01.002","volume":"35","author":"SR Kapadia","year":"2010","unstructured":"Kapadia SR, Schoenhagen P, Stewart W, Tuzcu EM. Imaging for transcatheter valve procedures. Curr Probl Cardiol. 2010;35:228\u201376.","journal-title":"Curr Probl Cardiol"},{"key":"2387_CR14","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1016\/j.jcin.2015.05.010","volume":"8","author":"A Hamdan","year":"2015","unstructured":"Hamdan A, Guetta V, Klempfner R, Konen E, Raanani E, Glikson M, et al. Inverse relationship between membranous septal length and the risk of atrioventricular block in patients undergoing transcatheter aortic valve implantation. JACC Cardiovasc Interv. 2015;8:1218\u201328.","journal-title":"JACC Cardiovasc Interv"},{"key":"2387_CR15","doi-asserted-by":"publisher","first-page":"1796","DOI":"10.1016\/j.jcin.2019.05.056","volume":"12","author":"H Jilaihawi","year":"2019","unstructured":"Jilaihawi H, Zhao Z, Du R, Staniloae C, Saric M, Neuburger PJ, et al. Minimizing permanent pacemaker following repositionable self-expanding transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2019;12:1796\u2013807.","journal-title":"JACC Cardiovasc Interv"},{"issue":"10 Pt A","key":"2387_CR16","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1016\/j.jcmg.2016.09.032","volume":"10","author":"SR Kapadia","year":"2017","unstructured":"Kapadia SR, Wazni O, Krishnaswamy A. Pacemaker implantation after TAVR. JACC Cardiovasc Imaging. 2017;10(10 Pt A):1148\u201350.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2387_CR17","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1016\/j.jcmg.2015.12.022","volume":"9","author":"H Jilaihawi","year":"2016","unstructured":"Jilaihawi H, Chen M, Webb J, Himbert D, Ruiz CE, Rod\u00e9s-Cabau J, et al. A bicuspid aortic valve imaging classification for the TAVR Era. JACC Cardiovasc Imaging. 2016;9:1145\u201358.","journal-title":"JACC Cardiovasc Imaging"},{"key":"2387_CR18","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1007\/s13239-020-00469-9","volume":"11","author":"DMC de Oliveira","year":"2020","unstructured":"de Oliveira DMC, Abdullah N, Green NC, Espino DM. Biomechanical assessment of bicuspid aortic valve phenotypes: a fluid\u2013structure interaction modelling approach. Cardiovasc Eng Technol. 2020;11:431\u201347.","journal-title":"Cardiovasc Eng Technol"},{"key":"2387_CR19","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1093\/eurheartj\/ehx785","volume":"39","author":"PJ van Rosendael","year":"2018","unstructured":"van Rosendael PJ, Delgado V, Bax JJ. Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J. 2018;39:2003\u201313.","journal-title":"Eur Heart J"},{"key":"2387_CR20","doi-asserted-by":"publisher","first-page":"1706","DOI":"10.1056\/NEJMoa1816885","volume":"380","author":"JJ Popma","year":"2019","unstructured":"Popma JJ, Deeb GM, Yakubov SJ, Mumtaz M, Gada H, O\u2019Hair D, et al. Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med. 2019;380:1706\u201315.","journal-title":"N Engl J Med"},{"key":"2387_CR21","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1016\/j.ijcard.2020.02.070","volume":"310","author":"K Kalogeras","year":"2020","unstructured":"Kalogeras K, Ruparelia N, Kabir T, Jabbour R, Naganuma T, Vavuranakis M, et al. Comparison of the self-expanding Evolut-PRO transcatheter aortic valve to its predecessor Evolut-R in the real world multicenter ATLAS registry. Int J Cardiol. 2020;310:120\u20135.","journal-title":"Int J Cardiol"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-021-02387-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-021-02387-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-021-02387-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,7]],"date-time":"2021-12-07T12:06:26Z","timestamp":1638878786000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-021-02387-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2387"],"URL":"https:\/\/doi.org\/10.1186\/s12872-021-02387-7","relation":{},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"22 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 November 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Ethical Committee of West China Hospital, Sichuan University with the reference number as 2019-1031.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All patients gave written informed consent for the study and following publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Y Feng and M. Chen are consultants for CardioFlow, Venus MedTech and Peijia Medical. The other authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"590"}}