{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,16]],"date-time":"2025-07-16T13:54:19Z","timestamp":1752674059407,"version":"3.37.3"},"reference-count":6,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T00:00:00Z","timestamp":1658361600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T00:00:00Z","timestamp":1658361600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Teaching Research Project of Air Force Medical Center","award":["2021JX001"],"award-info":[{"award-number":["2021JX001"]}]},{"name":"Millitary Logistical Special Project for Health Care","award":["18BJZ07"],"award-info":[{"award-number":["18BJZ07"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>X-ray fluoroscopy has been the primary cardiac imaging modality in permanent pacemaker implantation (PPI) operations, but it inevitably results in radiation exposure for both operators and patients. Fluoroscopy is considered a contraindication, especially in certain circumstances, such as gestation, during which the fetus is most sensitive to radiation exposure. Therefore, measures to avoid radiation exposure are necessary, and a more safe and feasible approach is needed for this procedure. Since the EnSite NavX mapping system (ENMS) can create the required geometric contours of those relevant cardiac structures and chambers, it can be used as an alternative to X-ray fluoroscopy in PPI. In addition, because the displacement of atrial leads is a common complication of PPI, lead displacement may occur more readily without fluoroscopic guidance. Therefore, reliable measures are required to prevent leads from displacement.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case introduction<\/jats:title>\n                <jats:p>A 41-year-old woman at the 15th week of gestation was referred to our department with recurrent episodes of syncope and amaurosis fugax for 2\u00a0years. Holter monitoring showed sinus rhythm, Mobitz Type II atrioventricular block and high-grade atrioventricular block with ventricular arrest up to 4945\u00a0ms. A dual-chamber PPI was performed successfully for the patient under the guidance of the ENMS instead of fluoroscopy. Displacement of atrial lead was effectively avoided by bending the top of atrial lead before implantation and making it a U-shape during operation, which left space for possible subsequent external pulling stress.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>For PPI, ENMS is a feasible and reliable alternative to traditional X-ray fluoroscopy, especially when performing operations on pregnant patients. By bending the top of the active-fixation atrial lead into a U-shape during operation, the displacement of atrial lead may be avoided.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12872-022-02764-w","type":"journal-article","created":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T18:02:50Z","timestamp":1658426570000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["EnSite NavX mapping system guided implantation of a dual-chamber permanent pacemaker in a 41-year-old pregnant woman with a 4-year follow-up"],"prefix":"10.1186","volume":"22","author":[{"given":"Peng","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guang-Sheng","family":"Wei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun-Hua","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9675-7037","authenticated-orcid":false,"given":"Yan-Jie","family":"Cao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Wei","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hang","family":"Shen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhi-Yue","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Ai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,7,21]]},"reference":[{"key":"2764_CR1","doi-asserted-by":"publisher","first-page":"1641","DOI":"10.1111\/pace.14283","volume":"44","author":"C Gianni","year":"2021","unstructured":"Gianni C, Domenico G, Della R, Natale A. Fluoroless 3D mapping-guided pacemaker implant in a pregnant patient. Pacing Clin Electrophysiol. 2021;44:1641\u20135.","journal-title":"Pacing Clin Electrophysiol"},{"key":"2764_CR2","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1111\/j.1540-8159.1999.tb00485.x","volume":"22","author":"D Antonelli","year":"1999","unstructured":"Antonelli D, Bloch L, Rosenfeld T. Implantation of permanent dual chamber pacemaker in a pregnant woman by transesophageal echocardiographic guidance. PACE. 1999;22:534\u20135.","journal-title":"PACE"},{"key":"2764_CR3","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1111\/pace.13248","volume":"41","author":"P Guo","year":"2018","unstructured":"Guo P, Qiu J, Wang Y, et al. Zero-fluoroscopy permanent pacemaker implantation using Ensite NavX system: clinical viability or fanciful technique. Pacing Clin Electrophysiol. 2018;41:122\u20137.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"2764_CR4","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1111\/jce.13120","volume":"28","author":"M Del Greco","year":"2017","unstructured":"Del Greco M, Maines M, Marini M, et al. Three-dimensional electroanatomic mapping system-enhanced cardiac resynchronization therapy device implantation: results from a multicenter registry. J Cardiovasc Electrophysiol. 2017;28(1):85\u201393.","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"1","key":"2764_CR5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s13256-020-02626-z","volume":"15","author":"Fu Guan","year":"2021","unstructured":"Guan Fu, et al. Delayed management of atrial lead displacement after pacemaker implantation: a case report. J Med Case Rep. 2021;15(1):9\u20139.","journal-title":"J Med Case Rep"},{"issue":"11","key":"2764_CR6","doi-asserted-by":"publisher","first-page":"2012","DOI":"10.1111\/j.1540-8159.1994.tb03791.x","volume":"17","author":"A Chauhan","year":"1994","unstructured":"Chauhan A, Grace AA, Newell SA, Stone DL, Shapiro LM, Schofeld PM, Petch MC. Early complications after dual chamber versus single chamber pacemaker implantation. Pacing Clin Electrophysiol. 1994;17(11):2012\u20135.","journal-title":"Pacing Clin Electrophysiol"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-022-02764-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-022-02764-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-022-02764-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,21]],"date-time":"2022-07-21T18:04:08Z","timestamp":1658426648000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-022-02764-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,21]]},"references-count":6,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["2764"],"URL":"https:\/\/doi.org\/10.1186\/s12872-022-02764-w","relation":{},"ISSN":["1471-2261"],"issn-type":[{"type":"electronic","value":"1471-2261"}],"subject":[],"published":{"date-parts":[[2022,7,21]]},"assertion":[{"value":"29 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Ethics Committee of the Air Force Medical Center, and written informed consent was also obtained from the participant. The study adhered to the tenets of the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors of this publication have no conflict of interest to declare. The current manuscript or part of it has not been published before.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"325"}}