{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T15:33:01Z","timestamp":1775489581083,"version":"3.50.1"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T00:00:00Z","timestamp":1684540800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T00:00:00Z","timestamp":1684540800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Clinical Research Plan for Shanghai Hospital Development Center","award":["SHD2020CR4096"],"award-info":[{"award-number":["SHD2020CR4096"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Dextrocardia with situs inversus (DSI) is a very rare congenital anomaly. Catheter manipulation and ablation of atrial fibrillation (AF) in patients with this anatomical variant is challenging for the operators. This case report presents a safe and effective AF ablation guided by the robotic magnetic navigation (RMN) system in combination with intracardiac echocardiograhy (ICE) in a patient with DSI.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 64-year-old male with DSI was referred for catheter ablation of symptomatic, drug-refractory paroxysmal AF. One transseptal access was achieved via the left femoral vein under the guidance of ICE. The three-dimensional reconstruction of the left atrium and the pulmonary veins (PVs) were performed by the magnetic catheter using the CARTO and the RMN system. Then, the electroanatomic map and pre-acquired CT images were merged. Finally, bilateral circumferential ablation lines were delivered around the ipsilateral PV ostia to achieve complete PV isolation (PVI).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This case demonstrates that AF catheter ablation under the guidance of the RMN system using ICE is feasible and safe in a patient with DSI. Moreover, the combination of these technologies broadly facilitates treatment of patients with complex anatomy, while reducing the risk of complications.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12872-023-03308-6","type":"journal-article","created":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T14:01:36Z","timestamp":1684591296000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Robotic magnetic navigation-guided pulmonary vein isolation in an atrial fibrillation patient with dextrocardia situs inversus: techniques and potential advantages"],"prefix":"10.1186","volume":"23","author":[{"given":"Qingzhi","family":"Luo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yun","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liqun","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7683-072X","authenticated-orcid":false,"given":"Qi","family":"Jin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,5,20]]},"reference":[{"issue":"2","key":"3308_CR1","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.amjcard.2007.02.095","volume":"100","author":"CM Bohun","year":"2007","unstructured":"Bohun CM, Potts JE, Casey BM, Sandor GG. A population-based study of cardiac malformations and outcomes associated with dextrocardia. Am J Cardiol. 2007;100(2):305\u20139.","journal-title":"Am J Cardiol"},{"issue":"2","key":"3308_CR2","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1111\/pace.14144","volume":"44","author":"X Zhao","year":"2021","unstructured":"Zhao X, Su X, Long DY, et al. Catheter ablation of atrial fibrillation in situs inversus dextrocardia: Challenge, improved procedure, outcomes, and literature review. Pacing Clin Electrophysiol. 2021;44(2):293\u2013305.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"8","key":"3308_CR3","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1111\/j.1540-8159.2012.03382.x","volume":"35","author":"J Bradfield","year":"2012","unstructured":"Bradfield J, Tung R, Mandapati R, Boyle NG, Shivkumar K. Catheter ablation utilizing remote magnetic navigation: a review of applications and outcomes. Pacing Clin Electrophysiol. 2012;35(8):1021\u201334.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"3308_CR4","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.hjc.2018.04.002","volume":"60","author":"D Leftheriotis","year":"2019","unstructured":"Leftheriotis D, Ikonomidis I, Flevari P, Frogoudaki A, Katsaras D. Cryoballoon ablation under transesophageal echocardiographic guidance in dextrocardia. Hellenic J Cardiol Jan-Feb. 2019;60(1):61\u20133.","journal-title":"Hellenic J Cardiol Jan-Feb"},{"issue":"6","key":"3308_CR5","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1002\/joa3.12240","volume":"35","author":"S Miyauchi","year":"2019","unstructured":"Miyauchi S, Nakano Y, Ikeuchi Y, et al. HotBalloon ablation of atrial fibrillation in patients with dextrocardia and situs inversus by \u201cmirror image\u201d approach. J Arrhythm. 2019;35(6):855\u20137.","journal-title":"J Arrhythm"},{"issue":"4","key":"3308_CR6","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1536\/ihj.20-804","volume":"62","author":"Y Yokoyama","year":"2021","unstructured":"Yokoyama Y, Aiba T, Miyamoto K, et al. Pulmonary Vein Isolation and Pacemaker Implantation in a Patient with Dextrocardia Situs Inversus. Int Heart J. 2021;62(4):927\u201331.","journal-title":"Int Heart J"},{"issue":"4","key":"3308_CR7","first-page":"282","volume":"24","author":"T Ulus","year":"2020","unstructured":"Ulus T, Dural M, \u015eener E, Al A, Mert KU, G\u00f6renek B. Atrial fibrillation and atrial flutter ablation using mirror image in a patient with dextrocardia with situs inversus. Anatol J Cardiol. 2020;24(4):282\u20134.","journal-title":"Anatol J Cardiol"},{"issue":"1","key":"3308_CR8","doi-asserted-by":"publisher","first-page":"1609","DOI":"10.4022\/jafib.1609","volume":"10","author":"GA Gromyko","year":"2017","unstructured":"Gromyko GA, Mihaylichenko SU, Novichkov SA, Mangutov DA, Kranin DL, Krukov EV. Pulmonary Vein Isolation for Treatment of Paroxysmal Atrial Fibrillation on Patient with Situs Inversus Totalis. J Atr Fibrillation Jun-Jul. 2017;10(1):1609.","journal-title":"J Atr Fibrillation Jun-Jul"},{"issue":"2","key":"3308_CR9","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1093\/europace\/euu224","volume":"17","author":"E Koutalas","year":"2015","unstructured":"Koutalas E, Bertagnolli L, Sommer P, et al. Efficacy and safety of remote magnetic catheter navigation vs. manual steerable sheath-guided ablation for catheter ablation of atrial fibrillation: a case-control study. Europace. 2015;17(2):232\u20138.","journal-title":"Europace"},{"issue":"1","key":"3308_CR10","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1111\/pace.14392","volume":"45","author":"S Schl\u00f6gl","year":"2022","unstructured":"Schl\u00f6gl S, Schl\u00f6gl KS, Haarmann H, et al. Remote magnetic navigation versus manual catheter ablation of atrial fibrillation: A single center long-term comparison. Pacing Clin Electrophysiol. 2022;45(1):14\u201322.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"10","key":"3308_CR11","first-page":"23801","volume":"23","author":"Q Luo","year":"2022","unstructured":"Luo Q, Xie Y, Bao Y, et al. Utilization of steerable sheath improves the efficiency of atrial fibrillation ablation guided by robotic magnetic navigation compared with fixed-curve sheath. Clin Cardiol. 2022;23(10):23801.","journal-title":"Clin Cardiol"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-023-03308-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-023-03308-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-023-03308-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T14:01:44Z","timestamp":1684591304000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-023-03308-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,20]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3308"],"URL":"https:\/\/doi.org\/10.1186\/s12872-023-03308-6","relation":{},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,20]]},"assertion":[{"value":"24 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable. Study approval was not necessary as this is a case report and consent for publication was taken from the patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from the patient for the publication of this case report. A copy of the written consent is available for review by the Editor-in-Chief of this journal.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors\u2019 declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"265"}}