{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:13:07Z","timestamp":1772165587705,"version":"3.50.1"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T00:00:00Z","timestamp":1696896000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T00:00:00Z","timestamp":1696896000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Aim<\/jats:title>\n                    <jats:p>To study effect of change in position (supine and standing) on pulmonary artery pressure (PAP) in ambulatory heart failure (HF) patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Seventeen patients with CardioMEMS\u00ae sensor and stable heart failure were consented and included in this single center study. Supine and standing measurements were obtained with at least 5\u00a0min interval between the two positions. These measurements included PAP readings utilizing the manufacturer handheld interrogator obtaining 10\u00a0s data in addition to the systemic blood pressure and heart rate recordings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Mean supine and standing readings and their difference (\u0394) were as follows respectively: Systolic PAP were 33.4 (\u00b1\u200911.19), 23.6 (\u00b1\u200910) and \u0394 was 9.9 mmHg (p\u2009=\u20090.0001), diastolic PAP were 14.2 (\u00b1\u20095.6), 7.9 (\u00b1\u20095.7) and \u0394 was 6.3 mmHg (p\u2009=\u20090.0001) and mean PAP were 21.8 (\u00b1\u20097.8), 14 (\u00b1\u20097.2) and \u0394 was 7.4 mmHg (p\u2009=\u20090.0001) while the systemic blood pressure did not vary significantly.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>There is orthostatic variation of PAP in ambulatory HF patients demonstrating a mean decline with standing in diastolic PAP by 6.3 mmHg, systolic PAP by 9.9 mmHg and mean PAP by 7.4 mmHg in absence of significant orthostatic variation in systemic blood pressure or heart rate. These findings have significant clinical implications and inform that PAP in each patient should always be measured in the same position. Since initial readings at the time of implant were taken in supine position, it may be best to use supine position or to obtain a baseline standing PAP reading if standing PAP is planned on being used.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12872-023-03534-y","type":"journal-article","created":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T16:31:03Z","timestamp":1696955463000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Orthostatic variation of pulmonary artery pressure in ambulatory heart failure patients"],"prefix":"10.1186","volume":"23","author":[{"given":"Prince","family":"Sethi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prakash","family":"Acharya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Payton","family":"Lancaster","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brianna","family":"Stack","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kartik","family":"Munshi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sagar","family":"Ranka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zubair","family":"Shah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew J.","family":"Sauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kamal","family":"Gupta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,10,10]]},"reference":[{"issue":"16","key":"3534_CR1","doi-asserted-by":"publisher","first-page":"1518","DOI":"10.1161\/CIRCULATIONAHA.117.027668","volume":"135","author":"TM Gorter","year":"2017","unstructured":"Gorter TM, Rienstra M, van Veldhuisen DJ. Measuring Pulmonary Artery Pressures in Heart failure: a new useful Diagnostic Tool? Circulation. 2017;135(16):1518\u201321.","journal-title":"Circulation"},{"issue":"17","key":"3534_CR2","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1161\/CIRCULATIONAHA.106.632208","volume":"114","author":"NF Voelkel","year":"2006","unstructured":"Voelkel NF, Quaife RA, Leinwand LA, Barst RJ, McGoon MD, Meldrum DR, Dupuis J, Long CS, Rubin LJ, Smart FW, Suzuki YJ, Gladwin M, Denholm EM, Gail DB. Right ventricular function and failure: report of a National Heart, Lung, and Blood Institute working group on cellular and molecular mechanisms of right heart failure. Circulation. 2006;114(17):1883\u201391.","journal-title":"Circulation"},{"issue":"24","key":"3534_CR3","doi-asserted-by":"publisher","first-page":"2859","DOI":"10.1001\/jama.295.24.2859","volume":"295","author":"E Ingelsson","year":"2006","unstructured":"Ingelsson E, Bj\u00f6rklund-Bodeg\u00e5rd K, Lind L, Arnl\u00f6v J, Sundstr\u00f6m J. Diurnal blood pressure pattern and risk of congestive heart failure. JAMA. 2006;295(24):2859\u201366.","journal-title":"JAMA"},{"issue":"5","key":"3534_CR4","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1038\/hr.2010.26","volume":"33","author":"G Grassi","year":"2010","unstructured":"Grassi G, Bombelli M, Seravalle G, Dell\u2019Oro R, Quarti-Trevano F. Diurnal blood pressure variation and sympathetic activity. Hypertens Res. 2010;33(5):381\u20135.","journal-title":"Hypertens Res"},{"issue":"5","key":"3534_CR5","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1161\/HYPERTENSIONAHA.120.14340","volume":"75","author":"J Jordan","year":"2020","unstructured":"Jordan J, Ricci F, Hoffmann F, Hamrefors V, Fedorowski A. Orthostatic Hypertension: critical Appraisal of an overlooked Condition. Hypertension. 2020;75(5):1151\u20138.","journal-title":"Hypertension"},{"issue":"7","key":"3534_CR6","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1038\/hr.2012.26","volume":"35","author":"Y Yano","year":"2012","unstructured":"Yano Y, Kario K. Nocturnal blood pressure and cardiovascular disease: a review of recent advances. Hypertens Res. 2012;35(7):695\u2013701.","journal-title":"Hypertens Res"},{"issue":"6","key":"3534_CR7","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1001\/jamacardio.2019.1384","volume":"4","author":"J Abraham","year":"2019","unstructured":"Abraham J, Bharmi R, Jonsson O, Oliveira GH, Artis A, Valika A, Capodilupo R, Adamson PB, Roberts G, Dalal N, Desai AS, Benza RL. Association of ambulatory hemodynamic monitoring of heart failure with clinical outcomes in a concurrent matched cohort analysis. JAMA Cardiol. 2019;4(6):556\u201363.","journal-title":"JAMA Cardiol"},{"issue":"17","key":"3534_CR8","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1161\/CIRCULATIONAHA.120.052503","volume":"143","author":"ME Nassif","year":"2021","unstructured":"Nassif ME, Qintar M, Windsor SL, Jermyn R, Shavelle DM, Tang F, Lamba S, Bhatt K, Brush J, Civitello A, Gordon R, Jonsson O, Lampert B, Pelzel J, Kosiborod MN. Empagliflozin Effects on Pulmonary Artery pressure in patients with heart failure: results from the EMBRACE-HF trial. Circulation. 2021;143(17):1673\u201386.","journal-title":"Circulation"},{"issue":"5","key":"3534_CR9","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1002\/ehf2.12850","volume":"7","author":"W Mullens","year":"2020","unstructured":"Mullens W, Martens P, Forouzan O, Dauw J, Vercammen J, Luwel E, Ceyssens W, Kockaerts V, Ameloot K, Dupont M. Effects of dapagliflozin on congestion assessed by remote pulmonary artery pressure monitoring. ESC Heart Fail. 2020;7(5):2071\u20133.","journal-title":"ESC Heart Fail"},{"issue":"2","key":"3534_CR10","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1080\/00015385.2022.2101777","volume":"78","author":"P Sethi","year":"2023","unstructured":"Sethi P, Lancaster P, Stack B, Steinkamp L, Acharya P, Munshi K, Hockstad E, Shah Z, Sauer AJ, Gupta K. Diurnal variation of pulmonary artery pressure in ambulatory heart failure patients. Acta Cardiol. 2023;78(2):256\u20139.","journal-title":"Acta Cardiol"},{"issue":"10","key":"3534_CR11","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1136\/thx.53.10.857","volume":"53","author":"DA Raeside","year":"1998","unstructured":"Raeside DA, Chalmers G, Clelland J, Madhok R, Peacock AJ. Pulmonary artery pressure variation in patients with connective tissue disease: 24 hour ambulatory pulmonary artery pressure monitoring. Thorax. 1998;53(10):857\u201362.","journal-title":"Thorax"},{"issue":"4","key":"3534_CR12","doi-asserted-by":"publisher","first-page":"e023839","DOI":"10.1161\/JAHA.121.023839","volume":"11","author":"C Berlier","year":"2022","unstructured":"Berlier C, Saxer S, Lichtblau M, Schneider SR, Schwarz EI, Furian M, Bloch KE, Carta AF, Ulrich S. Influence of Upright Versus Supine position on resting and Exercise Hemodynamics in Patients assessed for pulmonary hypertension. J Am Heart Assoc. 2022;11(4):e023839.","journal-title":"J Am Heart Assoc"},{"issue":"23","key":"3534_CR13","doi-asserted-by":"publisher","first-page":"e13945","DOI":"10.14814\/phy2.13945","volume":"6","author":"S Mizumi","year":"2018","unstructured":"Mizumi S, Goda A, Takeuchi K, Kikuchi H, Inami T, Soejima K, Satoh T. Effects of body position during cardiopulmonary exercise testing with right heart catheterization. Physiol Rep. 2018;6(23):e13945.","journal-title":"Physiol Rep"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-023-03534-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-023-03534-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-023-03534-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T01:09:10Z","timestamp":1700442550000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-023-03534-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,10]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["3534"],"URL":"https:\/\/doi.org\/10.1186\/s12872-023-03534-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2996327\/v1","asserted-by":"object"}]},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,10]]},"assertion":[{"value":"29 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 October 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dr. Andrew J. Sauer discloses consulting and speaking for Abbott, Boston Scientific, Impulse Dynamics, General Prognostics, Acorai, Heart Kinetics. Other authors do not have any conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The Institutional Review Board of University of Kansas Medical Center approved the study and informed consent was obtained from the participants. All authors using human data confirm that all studies were performed in accordance with relevant guidelines and regulations of the human subjects committee and conform to Declaration of Helsinki.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}}],"article-number":"503"}}