{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T00:55:10Z","timestamp":1792803310979,"version":"4.5.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T00:00:00Z","timestamp":1732320000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T00:00:00Z","timestamp":1732320000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"DOI":"10.1186\/s12872-024-04355-3","type":"journal-article","created":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T06:16:17Z","timestamp":1732342577000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Comparing HeartModelAI and cardiac magnetic resonance imaging for left ventricular volume and function evaluation in patients with dilated cardiomyopathy"],"prefix":"10.1186","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6954-4490","authenticated-orcid":false,"given":"Mahboobeh","family":"Sheikh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8668-4540","authenticated-orcid":false,"given":"Sahar Asl","family":"Fallah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2349-9353","authenticated-orcid":false,"given":"Muhammadhosein","family":"Moradi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3225-8498","authenticated-orcid":false,"given":"Arash","family":"Jalali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3721-0434","authenticated-orcid":false,"given":"Ahmad","family":"Vakili-Basir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0907-9435","authenticated-orcid":false,"given":"Mohammad","family":"Sahebjam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6687-995X","authenticated-orcid":false,"given":"Haleh","family":"Ashraf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0095-1880","authenticated-orcid":false,"given":"Arezou","family":"Zoroufian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,23]]},"reference":[{"issue":"11","key":"4355_CR1","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1016\/j.echo.2017.06.026","volume":"30","author":"G Tamborini","year":"2017","unstructured":"Tamborini G, Piazzese C, Lang RM, Muratori M, Chiorino E, Mapelli M, et al. Feasibility and accuracy of Automated Software for Transthoracic three-Dimensional Left Ventricular volume and function analysis: comparisons with two-Dimensional Echocardiography, three-Dimensional Transthoracic Manual Method, and Cardiac magnetic resonance imaging. J Am Soc Echocardiogr. 2017;30(11):1049\u201358.","journal-title":"J Am Soc Echocardiogr"},{"issue":"11","key":"4355_CR2","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1016\/j.acvd.2016.12.015","volume":"110","author":"F Levy","year":"2017","unstructured":"Levy F, Dan Schouver E, Iacuzio L, Civaia F, Rusek S, Dommerc C, et al. Performance of new automated transthoracic three-dimensional echocardiographic software for left ventricular volumes and function assessment in routine clinical practice: comparison with 3 Tesla cardiac magnetic resonance. Arch Cardiovasc Dis. 2017;110(11):580\u20139.","journal-title":"Arch Cardiovasc Dis"},{"issue":"1","key":"4355_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s12947-017-0121-8","volume":"16","author":"L Sun","year":"2018","unstructured":"Sun L, Feng H, Ni L, Wang H, Gao D. Realization of fully automated quantification of left ventricular volumes and systolic function using transthoracic 3D echocardiography. Cardiovasc Ultrasound. 2018;16(1):2.","journal-title":"Cardiovasc Ultrasound"},{"key":"4355_CR4","doi-asserted-by":"crossref","unstructured":"Barbieri A, Bursi F, Camaioni G, Maisano A, Imberti JF, Albini A et al. Echocardiographic left ventricular Mass Assessment: correlation between 2D-Derived Linear dimensions and 3-Dimensional Automated, Machine Learning-based methods in unselected patients. J Clin Med. 2021;10(6).","DOI":"10.3390\/jcm10061279"},{"key":"4355_CR5","doi-asserted-by":"crossref","unstructured":"Volpato V, Mor-Avi V, Narang A, Prater D, Gon\u00e7alves A, Tamborini G, et al. Automated, machine learning-based, 3D echocardiographic quantification of left ventricular mass. Echocardiography. 2019;36(2):312\u20139.","DOI":"10.1111\/echo.14234"},{"issue":"13","key":"4355_CR6","doi-asserted-by":"publisher","first-page":"4050","DOI":"10.12998\/wjcc.v10.i13.4050","volume":"10","author":"CK Pan","year":"2022","unstructured":"Pan CK, Zhao BW, Zhang XX, Pan M, Mao YK, Yang Y. Three-dimensional echocardiographic assessment of left ventricular volume in different heart diseases using a fully automated quantification software. World J Clin Cases. 2022;10(13):4050\u201363.","journal-title":"World J Clin Cases"},{"issue":"1","key":"4355_CR7","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/j.jjcc.2022.08.007","volume":"81","author":"VC Wu","year":"2023","unstructured":"Wu VC, Kitano T, Chu PH, Takeuchi M. Left ventricular volume and ejection fraction measurements by fully automated 3D echocardiography left chamber quantification software versus CMR: a systematic review and meta-analysis. J Cardiol. 2023;81(1):19\u201325.","journal-title":"J Cardiol"},{"issue":"7","key":"4355_CR8","doi-asserted-by":"publisher","first-page":"654","DOI":"10.2174\/1573405614666180815115756","volume":"15","author":"N Benameur","year":"2019","unstructured":"Benameur N, Arous Y, Ben Abdallah N, Kraiem T. Comparison between 3D Echocardiography and Cardiac magnetic resonance imaging (CMRI) in the measurement of left ventricular volumes and ejection fraction. Curr Med Imaging Rev. 2019;15(7):654\u201360.","journal-title":"Curr Med Imaging Rev"},{"key":"4355_CR9","doi-asserted-by":"crossref","unstructured":"Pinamonti B, Abate E, De Luca A, Finocchiaro G, Korcova R. Role of cardiac imaging: Echocardiography. Dilated cardiomyopathy: from Genetics to Clinical Management. 2019:83\u2013111.","DOI":"10.1007\/978-3-030-13864-6_7"},{"issue":"7","key":"4355_CR10","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1161\/CIRCRESAHA.116.309396","volume":"121","author":"EM McNally","year":"2017","unstructured":"McNally EM, Mestroni L. Dilated cardiomyopathy: genetic determinants and mechanisms. Circul Res. 2017;121(7):731\u201348.","journal-title":"Circul Res"},{"issue":"3","key":"4355_CR11","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1093\/ehjci\/jev014","volume":"16","author":"RM Lang","year":"2015","unstructured":"Lang RM, Badano LP, Mor-Avi V, Afilalo J, Armstrong A, Ernande L, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart Journal-Cardiovascular Imaging. 2015;16(3):233\u201371.","journal-title":"Eur Heart Journal-Cardiovascular Imaging"},{"issue":"11","key":"4355_CR12","doi-asserted-by":"publisher","first-page":"2057","DOI":"10.1111\/echo.14502","volume":"36","author":"N D\u2019Elia","year":"2019","unstructured":"D\u2019Elia N, Appadurai V, Mallouhi M, Ng J, Marwick T, Wahi S. Comparison of 3D echocardiographic-derived indices using fully automatic left ventricular endocardial tracing (heart model) and semiautomatic tracing (3DQ-ADV). Echocardiography. 2019;36(11):2057\u201363.","journal-title":"Echocardiography"},{"issue":"4","key":"4355_CR13","doi-asserted-by":"publisher","first-page":"259","DOI":"10.5455\/medarh.2022.76.259-266","volume":"76","author":"N Naser","year":"2022","unstructured":"Naser N, Stankovic I, Neskovic A. The reliability of Automated three-Dimensional Echocardiography-HeartModel(A.I.) Versus 2D Echocardiography Simpson methods in evaluation of left ventricle volumes and ejection fraction in patients with left ventricular dysfunction. Med Arch. 2022;76(4):259\u201366.","journal-title":"Med Arch"},{"issue":"7","key":"4355_CR14","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1016\/j.jcmg.2015.12.020","volume":"9","author":"W Tsang","year":"2016","unstructured":"Tsang W, Salgo IS, Medvedofsky D, Takeuchi M, Prater D, Weinert L, et al. Transthoracic 3D echocardiographic Left Heart Chamber quantification using an automated adaptive analytics Algorithm. JACC Cardiovasc Imaging. 2016;9(7):769\u201382.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"2","key":"4355_CR15","first-page":"1","volume":"17","author":"M Jafari-Fesharaki","year":"2021","unstructured":"Jafari-Fesharaki M, Alizadehasl A, Mohammadi K. Left ventricle assessment by three-dimensional HeartModel software in different types of mitral valve prolapse (Barlow\u2019s disease and fibroelastic deficiency) with severe mitral regurgitation. ARYA Atheroscler. 2021;17(2):1\u20137.","journal-title":"ARYA Atheroscler"},{"issue":"9","key":"4355_CR16","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1016\/j.echo.2017.05.018","volume":"30","author":"D Medvedofsky","year":"2017","unstructured":"Medvedofsky D, Mor-Avi V, Byku I, Singh A, Weinert L, Yamat M, et al. Three-dimensional echocardiographic automated quantification of Left Heart Chamber volumes using an adaptive analytics Algorithm: feasibility and impact of Image Quality in Nonselected patients. J Am Soc Echocardiogr. 2017;30(9):879\u201385.","journal-title":"J Am Soc Echocardiogr"},{"issue":"9","key":"4355_CR17","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1002\/jcu.22764","volume":"47","author":"F Levy","year":"2019","unstructured":"Levy F, Iacuzio L, Schouver ED, Essayagh B, Civaia F, Dommerc C, et al. Performance of a new fully automated transthoracic three-dimensional echocardiographic software for quantification of left cardiac chamber size and function: comparison with 3 Tesla cardiac magnetic resonance. J Clin Ultrasound. 2019;47(9):546\u201354.","journal-title":"J Clin Ultrasound"},{"issue":"9","key":"4355_CR18","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1016\/j.echo.2019.04.417","volume":"32","author":"T Kitano","year":"2019","unstructured":"Kitano T, Nabeshima Y, Otsuji Y, Negishi K, Takeuchi M. Accuracy of left ventricular volumes and ejection fraction measurements by Contemporary three-Dimensional Echocardiography with Semi- and fully automated Software: systematic review and Meta-analysis of 1,881 subjects. J Am Soc Echocardiogr. 2019;32(9):1105\u2013e155.","journal-title":"J Am Soc Echocardiogr"},{"issue":"8","key":"4355_CR19","doi-asserted-by":"publisher","first-page":"1205","DOI":"10.1007\/s10554-018-1336-y","volume":"34","author":"V Barletta","year":"2018","unstructured":"Barletta V, Hinojar R, Carbonell A, Gonz\u00e1lez-G\u00f3mez A, Fabiani I, Di Bello V, et al. Three-dimensional full automated software in the evaluation of the left ventricle function: from theory to clinical practice. Int J Cardiovasc Imaging. 2018;34(8):1205\u201313.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"3","key":"4355_CR20","doi-asserted-by":"publisher","first-page":"200","DOI":"10.4250\/jcvi.2019.27.e26","volume":"27","author":"N Beitner","year":"2019","unstructured":"Beitner N, Jenner J, S\u00f6rensson P. Comparison of left ventricular volumes measured by 3DE, SPECT and CMR. J Cardiovasc Imaging. 2019;27(3):200\u201311.","journal-title":"J Cardiovasc Imaging"},{"issue":"5","key":"4355_CR21","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1111\/echo.15322","volume":"39","author":"Y Wang","year":"2022","unstructured":"Wang Y, Zhang L, Liu J, Yue X, Shi H, Li Y, et al. Automated three-dimensional echocardiographic quantification for left ventricular volume and function in patients with hypertrophic cardiomyopathy. Echocardiography. 2022;39(5):658\u201366.","journal-title":"Echocardiography"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-024-04355-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-024-04355-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-024-04355-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T23:18:01Z","timestamp":1732403881000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-024-04355-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,23]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4355"],"URL":"https:\/\/doi.org\/10.1186\/s12872-024-04355-3","relation":{},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,23]]},"assertion":[{"value":"12 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures were conducted by the 1964 Declaration of Helsinki and its later extensions. Written informed consent was obtained for participation and publication. The ethics committee of Tehran University of Medical Sciences (TUMS) reviewed and approved this study (IR.TUMS.THC.REC.1402.065).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained for participation and publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"670"}}