{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T18:08:35Z","timestamp":1755799715664,"version":"3.44.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T00:00:00Z","timestamp":1755648000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007102","name":"Zagazig University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100007102","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>Prior studies have assessed in-stent diameter restenosis (ISDR) in coronary arteries using 64-slice multidetector computed tomography coronary angiography (MDCT-CA) compared to invasive coronary angiography (ICA), which is the gold standard. This study aimed to compare the diagnostic accuracy of monoenergetic reconstruction using third-generation dual-source dual-energy CT (DSDECT) to that of ICA reconstruction via adjunctive intravascular ultrasonography (IVUS) for evaluating the ISDR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A total of 95 patients with previously stented coronary arteries (involving 110 stents) underwent DSDECT followed by ICA and IVUS within a 24-h timeframe. The specificities, sensitivities, negative predictive values (NPVs), and positive predictive values (PPVs) of the DSDECT and ICA were compared for confirming or excluding the ISDR using in-stent area restenosis (ISAR) and a minimal luminal area (MLA)\u2009\u2264\u20094.0 mm<jats:sup>2<\/jats:sup> on IVUS as the reference standard.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Compared with IVUS, the latest DSDECT demonstrated good sensitivity (100%), specificity (92.4%), and accuracy (96.1%) in detecting the ISDR. Our study highlights a limitation in assessability for stents with diameters\u2009&lt;\u20093\u00a0mm, emphasizing the importance of careful patient selection. When employing an IVUS MLA of 4.0 mm<jats:sup>2<\/jats:sup> as a reference for identifying the ISDR, no significant difference was observed between DSDECT and ICA in the identification of the ISDR. However, it is important to note that the use of absolute cut-offs, such as\u2009&lt;\u20096.0 mm<jats:sup>2<\/jats:sup> in the left main or\u2009&lt;\u20094.0 mm<jats:sup>2<\/jats:sup>, may not universally apply across varying ethnicities and between sexes. The interpretation of the minimal luminal area (MLA) should be considered in the context of individual patient characteristics, and caution is advised to avoid potential misleading conclusions based solely on absolute thresholds.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>In summary, when assessing stent patency, the latest DSDECT exhibits similar performance to coronary angiography and IVUS. Moreover, it offers noninvasiveness, cost-effectiveness, and ease of operation, which are advantageous characteristics. However, it is essential to consider limitations in patient eligibility, including factors such as prior cardiac devices, arrhythmias, and any degree of chronic renal insufficiency, which may impact CT imaging analysis. The 100% negative predictive value (NPV) of third-generation DSDECT reliably excludes in-stent restenosis (ISDR), potentially obviating invasive angiography in stable patients with patent stents.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration<\/jats:title>\n            <jats:p>ZU-IRB#3915\/13-8-2017 Registered 13 August 2017, email: IRB_123@medicine.zu.edu.eg.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12872-025-04836-z","type":"journal-article","created":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T04:00:49Z","timestamp":1755662449000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative analysis of third-generation dual-energy CT and IVUS for in-stent restenosis detection"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2543-7674","authenticated-orcid":false,"given":"Mohey E. A.","family":"Eldeeb","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5989-0779","authenticated-orcid":false,"given":"Mohamed A.","family":"Mostafa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1702-9363","authenticated-orcid":false,"given":"Tarek A.","family":"Nagiub","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7755-3493","authenticated-orcid":false,"given":"Mohammed H. E.","family":"Alshair","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3850-9027","authenticated-orcid":false,"given":"Islam E.","family":"Shehata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,8,20]]},"reference":[{"issue":"3","key":"4836_CR1","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1093\/eurheartj\/ehz425","volume":"41","author":"J Knuuti","year":"2020","unstructured":"Knuuti J, Wijns W, Saraste A, et al. 2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J. 2020;41(3):407\u201377. https:\/\/doi.org\/10.1093\/eurheartj\/ehz425.","journal-title":"Eur Heart J"},{"key":"4836_CR2","doi-asserted-by":"publisher","first-page":"1919","DOI":"10.1016\/j.jacc.2006.08.025","volume":"48","author":"S Achenbach","year":"2006","unstructured":"Achenbach S. Computed tomography coronary angiography. J Am Coll Cardiol. 2006;48:1919\u201328. https:\/\/doi.org\/10.1016\/j.jacc.2006.08.025.","journal-title":"J Am Coll Cardiol"},{"key":"4836_CR3","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.amjcard.2004.05.045","volume":"94","author":"JD Schuijf","year":"2004","unstructured":"Schuijf JD, Bax JJ, Jukema JW. Feasibility of assessment of coronary stent patency using 16-slice computed tomography. Am J Cardiol. 2004;94:427\u201330. https:\/\/doi.org\/10.1016\/j.amjcard.2004.05.045.","journal-title":"Am J Cardiol"},{"key":"4836_CR4","doi-asserted-by":"publisher","first-page":"2663","DOI":"10.1016\/j.jacc.2010.02.013","volume":"55","author":"DB Mark","year":"2010","unstructured":"Mark DB, Berman DS, Budoff MJ, et al. ACCF\/ACR\/AHA\/NASCI\/SAIP\/SCAI\/SCCT 2010 expert consensus document on coronary computed tomographic angiography: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents. J Am Coll Cardiol. 2010;55:2663\u201399. https:\/\/doi.org\/10.1016\/j.jacc.2010.02.013.","journal-title":"J Am Coll Cardiol"},{"key":"4836_CR5","doi-asserted-by":"publisher","first-page":"2567","DOI":"10.1093\/eurheartj\/ehl296","volume":"27","author":"J Rixe","year":"2006","unstructured":"Rixe J, Achenbach S, Ropers D, et al. Assessment of coronary artery stent restenosis by 64-slice multidetector computed tomography. Eur Heart J. 2006;27:2567\u201372. https:\/\/doi.org\/10.1093\/eurheartj\/ehl296.","journal-title":"Eur Heart J"},{"key":"4836_CR6","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/j.jacc.2006.10.065","volume":"49","author":"M Ehara","year":"2007","unstructured":"Ehara M, Kawai M, Surmely JF, et al. Diagnostic accuracy of coronary in-stent restenosis using 64-slice computed tomography: comparison with invasive coronary angiography. J Am Coll Cardiol. 2007;49:951\u20139. https:\/\/doi.org\/10.1016\/j.jacc.2006.10.065.","journal-title":"J Am Coll Cardiol"},{"key":"4836_CR7","doi-asserted-by":"publisher","first-page":"2204","DOI":"10.1016\/j.jacc.2007.02.037","volume":"49","author":"F Cademartiri","year":"2007","unstructured":"Cademartiri F, Schuijf JD, Pugliese F, et al. Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis. J Am Coll Cardiol. 2007;49:2204\u201310. https:\/\/doi.org\/10.1016\/j.jacc.2007.02.037.","journal-title":"J Am Coll Cardiol"},{"key":"4836_CR8","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1016\/j.acra.2006.08.015","volume":"13","author":"C Rist","year":"2006","unstructured":"Rist C, Von Ziegler F, Nikolaou K, et al. Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography. Acad Radiol. 2006;13:1465\u201373. https:\/\/doi.org\/10.1016\/j.acra.2006.08.015.","journal-title":"Acad Radiol"},{"key":"4836_CR9","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1016\/j.amjcard.2009.01.341","volume":"103","author":"D Andreini","year":"2009","unstructured":"Andreini D, Pontone G, Bartorelli AL, et al. Comparison of feasibility and diagnostic accuracy of 64-slice multidetector computed tomographic coronary angiography versus invasive coronary angiography versus intravascular ultrasound for evaluation of in-stent restenosis. Am J Cardiol. 2009;103:1349\u201358. https:\/\/doi.org\/10.1016\/j.amjcard.2009.01.341.","journal-title":"Am J Cardiol"},{"key":"4836_CR10","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1097\/RTI.0b013e3181c4f7f7","volume":"25","author":"SH Chung","year":"2010","unstructured":"Chung SH, Kim YJ, Hur J, et al. Evaluation of coronary artery in-stent restenosis by 64-section computed tomography: factors affecting assessment and accurate diagnosis. J Thorac Imaging. 2010;25:57\u201363. https:\/\/doi.org\/10.1097\/RTI.0b013e3181c4f7f7.","journal-title":"J Thorac Imaging"},{"key":"4836_CR11","doi-asserted-by":"publisher","first-page":"85","DOI":"10.2214\/AJR.09.3231","volume":"194","author":"JJ Wykrzykowska","year":"2010","unstructured":"Wykrzykowska JJ, Arbab-Zadeh A, Godoy G, et al. Assessment of in-stent restenosis using 64-MDCT: analysis of the CORE-64 Multicenter International Trial. Am J Roentgenol. 2010;194:85\u201392. https:\/\/doi.org\/10.2214\/AJR.09.3231.","journal-title":"Am J Roentgenol"},{"key":"4836_CR12","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1016\/j.amjcard.2007.06.046","volume":"100","author":"N Carrabba","year":"2007","unstructured":"Carrabba N, Bamoshmoosh M, Carusi LM, et al. Usefulness of 64-slice multidetector computed tomography for detecting drug eluting in-stent restenosis. Am J Cardiol. 2007;100:1754\u20138. https:\/\/doi.org\/10.1016\/j.amjcard.2007.06.046.","journal-title":"Am J Cardiol"},{"key":"4836_CR13","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1148\/radiol.2452062067","volume":"245","author":"JD Schuijf","year":"2007","unstructured":"Schuijf JD, Pundziute G, Jukema JW, et al. Evaluation of patients with previous coronary stent implantation with 64-section CT. Radiology. 2007;245:416\u201323. https:\/\/doi.org\/10.1148\/radiol.2452062067.","journal-title":"Radiology"},{"key":"4836_CR14","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.1016\/j.jacc.2003.11.035","volume":"43","author":"AW Leber","year":"2004","unstructured":"Leber AW, Knez A, Becker A, et al. Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol. 2004;43:1241\u20137. https:\/\/doi.org\/10.1016\/j.jacc.2003.11.035.","journal-title":"J Am Coll Cardiol"},{"key":"4836_CR15","doi-asserted-by":"publisher","first-page":"1276","DOI":"10.1253\/circj.CJ-07-1061","volume":"72","author":"A Tanaka","year":"2008","unstructured":"Tanaka A, Shimada K, Yoshida K, et al. Noninvasive assessment of plaque rupture by 64-slice multidetector computed tomography: Comparison with intravascular ultrasound. Circ J. 2008;72:1276\u201381. https:\/\/doi.org\/10.1253\/circj.CJ-07-1061.","journal-title":"Circ J"},{"key":"4836_CR16","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.ijcard.2011.03.047","volume":"160","author":"H Takaoka","year":"2012","unstructured":"Takaoka H, Ishibashi I, Uehara M, et al. Comparison of image characteristics of plaques in culprit coronary arteries by 64 slice CT and intravascular ultrasound in acute coronary syndromes. Int J Cardiol. 2012;160:119\u201326. https:\/\/doi.org\/10.1016\/j.ijcard.2011.03.047.","journal-title":"Int J Cardiol"},{"key":"4836_CR17","doi-asserted-by":"publisher","first-page":"1871","DOI":"10.1007\/s00330-015-4011-3","volume":"26","author":"S Mangold","year":"2016","unstructured":"Mangold S, Canna\u00f3 PM, Schoepf UJ, et al. Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study. Eur Radiol. 2016;26:1871\u20138. https:\/\/doi.org\/10.1007\/s00330-015-4011-3.","journal-title":"Eur Radiol"},{"key":"4836_CR18","unstructured":"World Health Organization. Prevention of diabetes mellitus. Report of a WHO study group. World Health Organ Tech Rep Ser. 1994;844:1\u2013100."},{"issue":"3","key":"4836_CR19","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/j.jcmg.2021.08.022","volume":"15","author":"D Andreini","year":"2022","unstructured":"Andreini D, Pontone G, Bartorelli AL, et al. CMR versus ICA for cardiovascular evaluation before aortic valve replacement: a multicenter prospective study. JACC Cardiovasc Imaging. 2022;15(3):472\u201385. https:\/\/doi.org\/10.1016\/j.jcmg.2021.08.022.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"5","key":"4836_CR20","doi-asserted-by":"publisher","first-page":"3055","DOI":"10.1007\/s00330-021-08484-7","volume":"32","author":"AJ van der Molen","year":"2022","unstructured":"van der Molen AJ, Reimer P, Dekkers IA, et al. Post-contrast acute kidney injury - Part 2: risk stratification, role of hydration and other prophylactic measures, patients taking metformin and chronic dialysis patients. Eur Radiol. 2022;32(5):3055\u201365. https:\/\/doi.org\/10.1007\/s00330-021-08484-7.","journal-title":"Eur Radiol"},{"key":"4836_CR21","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1016\/j.ijcard.2007.07.046","volume":"130","author":"K Nakamura","year":"2008","unstructured":"Nakamura K, Funabashi N, Uehara M, et al. Impairment factors for evaluating the patency of drug-eluting stents and bare metal stents in coronary arteries by 64-slice computed tomography versus conventional coronary angiography. Int J Cardiol. 2008;130:349\u201356. https:\/\/doi.org\/10.1016\/j.ijcard.2007.07.046.","journal-title":"Int J Cardiol"},{"key":"4836_CR22","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1253\/circj.CJ-08-0750","volume":"73","author":"E Matsunaga","year":"2009","unstructured":"Matsunaga E, Takaya N, Yokoyama T, et al. Relationship between coronary artery wall thickness measured by 64-slice multidetector computed tomography and cardiovascular risk factors. Circ J. 2009;73:681\u20135. https:\/\/doi.org\/10.1253\/circj.CJ-08-0750.","journal-title":"Circ J"},{"key":"4836_CR23","doi-asserted-by":"publisher","unstructured":"Motoyama S, Kondo T, Anno H, et al. Atherosclerotic plaque characterization by 0.5-mm-slice multislice computed tomographic imaging. Circ J. 2007;71:363\u20136. https:\/\/doi.org\/10.1253\/circj.71.363","DOI":"10.1253\/circj.71.363"},{"key":"4836_CR24","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1097\/RCT.0b013e31817eb47a","volume":"33","author":"J Hur","year":"2009","unstructured":"Hur J, Kim YJ, Lee HJ, et al. Quantification and characterization of obstructive coronary plaques using 64-slice computed tomography: a comparison with intravascular ultrasound. J Comput Assist Tomogr. 2009;33:186\u201392. https:\/\/doi.org\/10.1097\/RCT.0b013e31817eb47a.","journal-title":"J Comput Assist Tomogr"},{"key":"4836_CR25","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1253\/circj.CJ-08-1234","volume":"73","author":"E Kunita","year":"2009","unstructured":"Kunita E, Fujii T, Urabe Y, et al. Coronary plaque stabilization followed by color code plaqueTM analysis with 64-slice multidetector row computed tomography. Circ J. 2009;73:772\u20135. https:\/\/doi.org\/10.1253\/circj.CJ-08-1234.","journal-title":"Circ J"},{"key":"4836_CR26","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.ijcard.2010.01.012","volume":"149","author":"K Harada","year":"2011","unstructured":"Harada K, Amano T, Uetani T, et al. Accuracy of 64-slice multidetector computed tomography for classification and quantitation of coronary plaque: comparison with integrated backscatter intravascular ultrasound. Int J Cardiol. 2011;149:95\u2013101. https:\/\/doi.org\/10.1016\/j.ijcard.2010.01.012.","journal-title":"Int J Cardiol"},{"issue":"10076","key":"4836_CR27","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1016\/S0140-6736(17)30057-0","volume":"389","author":"EC Nijssen","year":"2017","unstructured":"Nijssen EC, Rennenberg RJ, Nelemans PJ, et al. Prophylactic hydration to protect renal function from intravascular iodinated contrast material in patients at high risk of contrast-induced nephropathy (AMACING): a prospective, randomised, phase 3, controlled, open-label, non-inferiority trial. Lancet. 2017;389(10076):1312\u201322. https:\/\/doi.org\/10.1016\/S0140-6736(17)30057-0.","journal-title":"Lancet"},{"issue":"5","key":"4836_CR28","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1001\/jamainternmed.2021.0116","volume":"181","author":"JS McDonald","year":"2021","unstructured":"McDonald JS, McDonald RJ, Williamson EE, et al. Comparative risk of acute kidney injury following contrast-enhanced CT versus conventional angiography in patients with chronic kidney disease: a cohort study. JAMA Intern Med. 2021;181(5):649\u201357. https:\/\/doi.org\/10.1001\/jamainternmed.2021.0116.","journal-title":"JAMA Intern Med"},{"key":"4836_CR29","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.1016\/j.amjcard.2009.05.065","volume":"104","author":"SB Joshi","year":"2009","unstructured":"Joshi SB, Okabe T, Roswell RO, et al. Accuracy of computed tomographic angiography for stenosis quantification using quantitative coronary angiography or intravascular ultrasound as the gold standard. Am J Cardiol. 2009;104:1047\u201351. https:\/\/doi.org\/10.1016\/j.amjcard.2009.05.065.","journal-title":"Am J Cardiol"},{"key":"4836_CR30","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1097\/RLI.0b013e3181e39d22","volume":"45","author":"FR de Graaf","year":"2010","unstructured":"de Graaf FR, Schuijf JD, van Velzen JE, et al. Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography to noninvasively assess in-stent restenosis. Investig Radiol. 2010;45:331\u201340. https:\/\/doi.org\/10.1097\/RLI.0b013e3181e39d22.","journal-title":"Investig Radiol"},{"key":"4836_CR31","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.amjcard.2008.11.039","volume":"103","author":"T Pflederer","year":"2009","unstructured":"Pflederer T, Marwan M, Renz A, et al. Noninvasive assessment of coronary in-stent restenosis by dual-source computed tomography. Am J Cardiol. 2009;103:812\u20137. https:\/\/doi.org\/10.1016\/j.amjcard.2008.11.039.","journal-title":"Am J Cardiol"},{"key":"4836_CR32","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1016\/j.zumed.2023.07.003","volume":"29","author":"ME Eldeeb","year":"2023","unstructured":"Eldeeb ME, Mostafa MA, Nagiub TA, Alshair MH, Shehata IE. Accuracy of Newer Generation Dual Source Multi-Detector Computerized Tomography for Detection of Coronary In-stent restenosis in Comparison with Invasive Coronary Angiography and Intravascular Ultrasound: A Comparative Cross-Sectional Study. Zag Uni Med J. 2023;29:547\u201358. https:\/\/doi.org\/10.1016\/j.zumed.2023.07.003.","journal-title":"Zag Uni Med J"},{"issue":"8 Pt 1","key":"4836_CR33","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1016\/j.jcmg.2018.10.020","volume":"12","author":"D Andreini","year":"2019","unstructured":"Andreini D, Pontone G, Mushtaq S, et al. Impact of coronary calcium on diagnostic accuracy of computed tomography angiography for stenosis detection in diabetic patients. JACC Cardiovasc Imaging. 2019;12(8 Pt 1):1485\u201393. https:\/\/doi.org\/10.1016\/j.jcmg.2018.10.020.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"7","key":"4836_CR34","doi-asserted-by":"publisher","first-page":"4112","DOI":"10.1007\/s00330-020-06758-0","volume":"30","author":"SB Joshi","year":"2020","unstructured":"Joshi SB, Okabe T, Roswell RO, et al. Diabetes mellitus predicts higher artifact burden in coronary stent evaluation by CT angiography: A IVUS-CT registry study. Eur Radiol. 2020;30(7):4112\u201320. https:\/\/doi.org\/10.1007\/s00330-020-06758-0.","journal-title":"Eur Radiol"},{"issue":"12","key":"4836_CR35","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1016\/j.acra.2006.08.015","volume":"13","author":"C Rist","year":"2006","unstructured":"Rist C, von Ziegler F, Nikolaou K, et al. Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography. Acad Radiol. 2006;13(12):1465\u201373. https:\/\/doi.org\/10.1016\/j.acra.2006.08.015.","journal-title":"Acad Radiol"},{"key":"4836_CR36","doi-asserted-by":"publisher","first-page":"S36","DOI":"10.1016\/j.jacc.2022.04.055","volume":"79","author":"ME Eldeeb","year":"2022","unstructured":"Eldeeb ME, Mostafa M, Naguib TA, Alshair MH, Shehata IE. TCTAP A-058 The Diagnostic Precision of Monoenergetic Reconstructions Using Dual-Source Dual-Energy CT Compared to Invasive Coronary Angiography With Add on Intravascular Ultrasound to Evaluate In-Stent Restenosis: Cross-Sectional Study. J Am Coll Cardiol. 2022;79:S36. https:\/\/doi.org\/10.1016\/j.jacc.2022.04.055.","journal-title":"J Am Coll Cardiol"},{"key":"4836_CR37","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1161\/CIRCULATIONAHA.108.814382","volume":"120","author":"M Dewey","year":"2009","unstructured":"Dewey M, Zimmermann E, Deissenrieder F, et al. Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation. 2009;120:867\u201375. https:\/\/doi.org\/10.1161\/CIRCULATIONAHA.108.814382.","journal-title":"Circulation"},{"key":"4836_CR38","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1148\/radiol.2421080634","volume":"242","author":"D Oncel","year":"2009","unstructured":"Oncel D, Oncel G, Karaca M. Coronary stent patency and in-stent restenosis: determination with 64-section multidetector CT coronary angiography-initial experience. Radiology. 2009;242:403\u20139. https:\/\/doi.org\/10.1148\/radiol.2421080634.","journal-title":"Radiology"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-025-04836-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-025-04836-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-025-04836-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T04:00:51Z","timestamp":1755662451000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccardiovascdisord.biomedcentral.com\/articles\/10.1186\/s12872-025-04836-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,20]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4836"],"URL":"https:\/\/doi.org\/10.1186\/s12872-025-04836-z","relation":{},"ISSN":["1471-2261"],"issn-type":[{"type":"electronic","value":"1471-2261"}],"subject":[],"published":{"date-parts":[[2025,8,20]]},"assertion":[{"value":"18 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The protocol was approved by the Institutional Review Board (IRB), Faculty of Medicine, Zagazig University (ZU-IRB#3915\/13\u20138-2017), which confirmed that all procedures were performed in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"We confirm that informed consent was obtained from all study participants or their legal guardians for the publication of identifying information or images in this online open-access publication. All efforts were made to ensure the privacy and confidentiality of the participants involved in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"<!--Emphasis Type='Bold' removed-->Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"614"}}