{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:38:35Z","timestamp":1792787915491,"version":"4.5.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T00:00:00Z","timestamp":1790121600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:00:00Z","timestamp":1790294400000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum D\u00fcsseldorf. Anstalt \u00f6ffentlichen Rechts","id":[{"id":"https:\/\/ror.org\/006k2kk72","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cardiovasc Disord"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Quantitative myocardial T1 mapping is an established technique in cardiovascular magnetic resonance (CMR). However, conventional T1 mapping requires relatively long breath-holds (BH), which may lead to breathing artifacts and reduced image quality in patients with limited BH capacity. The T1 fast low angle shot (T1FLASH) sequence enables myocardial T1 mapping with shorter BH durations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      In this prospective study, 14 healthy adult volunteers (8 female; mean age 27\u2009\u00b1\u20094 years) underwent myocardial T1 mapping at 1.5 T using modified Look-Locker inversion recovery with motion correction (T1 MOLLI MOCO) and rapid T1FLASH. Both sequences were acquired during BH and free breathing (FB). Global and segmental myocardial T1 values and image quality were assessed. Interrater, intrarater, and interstudy reproducibility were evaluated. Comfort was assessed using a questionnaire. Statistical analysis included the Shapiro-Wilk test, paired t-test, Pearson correlation, Bland-Altman analysis, intraclass correlation coefficient, Wilcoxon signed-rank test, and Spearman rank correlation (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      BH duration was significantly shorter with rapid T1FLASH compared with T1 MOLLI MOCO (3\u20134\u00a0s vs. 12\u201314\u00a0s), and participant comfort was higher with rapid T1FLASH (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). During BH, global myocardial T1 values were significantly higher with rapid T1FLASH (1030\u2009\u00b1\u200935 ms) than with T1 MOLLI MOCO (1000\u2009\u00b1\u200926 ms;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.01). The slightly increased variability observed with rapid T1FLASH remained below diagnostically relevant thresholds (4% error margin). Both techniques showed moderate-to-good correlation for global T1 values (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.63;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.01). Rapid T1FLASH demonstrated good image quality that was comparable for clinical interpretation during BH, although T1 MOLLI MOCO received slightly higher qualitative image scores. During FB, variability of global and segmental T1 measurements increased significantly, with apical segments being more and AHA segments 2 (basal anteroseptal), 5 (basal inferolateral), 8 (mid anteroseptal), 11 (mid inferolateral) less affected by respiratory artifacts. Interrater, intrarater, and interstudy reproducibility were good to excellent.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Rapid T1FLASH demonstrated good agreement with conventional T1 MOLLI MOCO and reproducible myocardial T1 measurements, with substantially reduced BH duration while maintaining good image quality. These findings support further evaluation of rapid T1FLASH as an alternative T1 mapping approach in patients with limited BH capacity. Conventional T1 MOLLI MOCO remains the preferred technique when adequate BH can be achieved.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12872-026-06687-8","type":"journal-article","created":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T12:03:58Z","timestamp":1790165038000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Native myocardial T1 mapping using rapid 1.5T T1FLASH and T1 MOLLI during breath-hold and free-breathing"],"prefix":"10.1186","volume":"26","author":[{"given":"Lena Maria","family":"R\u00f6wer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yara","family":"Hussen-Demir","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pablo Emilio","family":"Verde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Voit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Frahm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerald","family":"Antoch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dirk","family":"Klee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Pillekamp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,23]]},"reference":[{"issue":"2","key":"6687_CR1","doi-asserted-by":"publisher","first-page":"e002504","DOI":"10.1161\/CIRCIMAGING.114.002504","volume":"8","author":"E Riesenkampff","year":"2015","unstructured":"Riesenkampff E, Messroghli DR, Redington AN, Grosse-Wortmann L. Myocardial T1 mapping in pediatric and congenital heart disease. Circ Cardiovasc Imaging. 2015;8(2):e002504. https:\/\/doi.org\/10.1161\/CIRCIMAGING.114.002504.","journal-title":"Circ Cardiovasc Imaging"},{"issue":"17","key":"6687_CR2","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1016\/j.jacc.2013.11.066","volume":"63","author":"SM Dusenbery","year":"2014","unstructured":"Dusenbery SM, Jerosch-Herold M, Rickers C, Colan SD, Geva T, Newburger JW, et al. Myocardial extracellular remodeling is associated with ventricular diastolic dysfunction in children and young adults with congenital aortic stenosis. J Am Coll Cardiol. 2014;63(17):1778\u201385. https:\/\/doi.org\/10.1016\/j.jacc.2013.11.066.","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"6687_CR3","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1002\/jmri.26866","volume":"51","author":"E Aherne","year":"2020","unstructured":"Aherne E, Chow K, Carr J. Cardiac T1 mapping: Techniques and applications. J Magn Reson Imaging. 2020;51(5):1336\u201356. https:\/\/doi.org\/10.1002\/jmri.26866.","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"6687_CR4","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jcmg.2015.11.005","volume":"9","author":"AJ Taylor","year":"2016","unstructured":"Taylor AJ, Salerno M, Dharmakumar R, Jerosch-Herold M. T1 Mapping: Basic Techniques and Clinical Applications. JACC Cardiovasc Imaging. 2016;9(1):67\u201381. https:\/\/doi.org\/10.1016\/j.jcmg.2015.11.005.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"1","key":"6687_CR5","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1186\/s12968-020-00632-0","volume":"22","author":"SJ Backhaus","year":"2020","unstructured":"Backhaus SJ, Lange T, Beuthner BE, Topci R, Wang X, Kowallick JT, et al. Real-time cardiovascular magnetic resonance T1 and extracellular volume fraction mapping for tissue characterisation in aortic stenosis. J Cardiovasc Magn Reson. 2020;22(1):46. https:\/\/doi.org\/10.1186\/s12968-020-00632-0.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"6687_CR6","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1186\/1532-429X-14-15","volume":"14","author":"E Dall\u2019Armellina","year":"2012","unstructured":"Dall\u2019Armellina E, Piechnik SK, Ferreira VM, Si QL, Robson MD, Francis JM, et al. Cardiovascular magnetic resonance by non contrast T1-mapping allows assessment of severity of injury in acute myocardial infarction. J Cardiovasc Magn Reson. 2012;14(1):15. https:\/\/doi.org\/10.1186\/1532-429X-14-15.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"6687_CR7","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/1532-429X-16-2","volume":"16","author":"P Kellman","year":"2014","unstructured":"Kellman P, Hansen MS. T1-mapping in the heart: accuracy and precision. J Cardiovasc Magn Reson. 2014;16(1):2. https:\/\/doi.org\/10.1186\/1532-429X-16-2.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"6687_CR8","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/mrm.20110","volume":"52","author":"DR Messroghli","year":"2004","unstructured":"Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP. Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med. 2004;52(1):141\u20136. https:\/\/doi.org\/10.1002\/mrm.20110.","journal-title":"Magn Reson Med"},{"issue":"6","key":"6687_CR9","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1002\/mrm.23153","volume":"67","author":"H Xue","year":"2012","unstructured":"Xue H, Shah S, Greiser A, Guetter C, Littmann A, Jolly MP, et al. Motion correction for myocardial T1 mapping using image registration with synthetic image estimation. Magn Reson Med. 2012;67(6):1644\u201355. https:\/\/doi.org\/10.1002\/mrm.23153.","journal-title":"Magn Reson Med"},{"issue":"3","key":"6687_CR10","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1148\/radiol.14140296","volume":"272","author":"S Roujol","year":"2014","unstructured":"Roujol S, Weing\u00e4rtner S, Foppa M, et al. Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE. Radiology. 2014;272(3):683\u20139. https:\/\/doi.org\/10.1148\/radiol.14140296.","journal-title":"Radiology"},{"key":"6687_CR11","doi-asserted-by":"publisher","first-page":"1160183","DOI":"10.3389\/fcvm.2023.1160183","volume":"10","author":"CD Sheagren","year":"2023","unstructured":"Sheagren CD, Cao T, Patel JH, Chen Z, Lee HL, Wang N, et al. Motion-compensated T1 mapping in cardiovascular magnetic resonance imaging: a technical review. Front Cardiovasc Med. 2023;10:1160183. https:\/\/doi.org\/10.3389\/fcvm.2023.1160183.","journal-title":"Front Cardiovasc Med"},{"issue":"1","key":"6687_CR12","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1002\/jmri.29373","volume":"61","author":"NY Pan","year":"2025","unstructured":"Pan NY, Huang TY, Yu JJ, Peng HH, Chuang TC, Lin YR, et al. Virtual MOLLI Target: Generative Adversarial Networks Toward Improved Motion Correction in MRI Myocardial T1 Mapping. J Magn Reson Imaging. 2025;61(1):209\u201319. https:\/\/doi.org\/10.1002\/jmri.29373.","journal-title":"J Magn Reson Imaging"},{"issue":"1068","key":"6687_CR13","doi-asserted-by":"publisher","first-page":"20160255","DOI":"10.1259\/bjr.20160255","volume":"89","author":"X Wang","year":"2016","unstructured":"Wang X, Joseph AA, Kalentev O, Merboldt KD, Voit D, Roeloffs VB, et al. High-resolution myocardial T1 mapping using single-shot inversion recovery fast low-angle shot MRI with radial undersampling and iterative reconstruction. Br J Radiol. 2016;89(1068):20160255. https:\/\/doi.org\/10.1259\/bjr.20160255.","journal-title":"Br J Radiol"},{"issue":"5","key":"6687_CR14","doi-asserted-by":"publisher","first-page":"2692","DOI":"10.1002\/mrm.28892","volume":"86","author":"LM R\u00f6wer","year":"2021","unstructured":"R\u00f6wer LM, Uelwer T, Hu\u00dfmann J, Malik H, Eichinger M, Voit D, et al. Spirometry-based reconstruction of real-time cardiac MRI: Motion control and quantification of heart-lung interactions. Magn Reson Med. 2021;86(5):2692\u2013702. https:\/\/doi.org\/10.1002\/mrm.28892.","journal-title":"Magn Reson Med"},{"issue":"8","key":"6687_CR15","doi-asserted-by":"publisher","first-page":"e18019","DOI":"10.1002\/mp.18019","volume":"52","author":"H Malik","year":"2025","unstructured":"Malik H, Uelwer T, R\u00f6wer LM, Hu\u00dfmann J, Verde PE, Harmeling S, et al. Machine-learning-based prediction of respiratory flow and lung volume from real-time cardiac MRI using MR-compatible spirometry. Med Phys. 2025;52(8):e18019. https:\/\/doi.org\/10.1002\/mp.18019.","journal-title":"Med Phys"},{"issue":"1","key":"6687_CR16","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/1532-429X-14-63","volume":"14","author":"P Kellman","year":"2012","unstructured":"Kellman P, Wilson JR, Xue H, Ugander M, Arai AE. Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method. J Cardiovasc Magn Reson. 2012;14(1):63. https:\/\/doi.org\/10.1186\/1532-429X-14-63.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"3","key":"6687_CR17","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1002\/cmr.a.21339","volume":"44","author":"R Ahmad","year":"2015","unstructured":"Ahmad R, Ding Y, Simonetti OP. Edge Sharpness Assessment by Parametric Modeling: Application to Magnetic Resonance Imaging. Concepts Magn Reson Part A Bridg. Educ Res. 2015;44(3):138\u201349. https:\/\/doi.org\/10.1002\/cmr.a.21339.","journal-title":"Educ Res"},{"issue":"1","key":"6687_CR18","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1186\/s12968-019-0570-3","volume":"21","author":"X Wang","year":"2019","unstructured":"Wang X, Kohler F, Unterberg-Buchwald C, Lotz J, Frahm J, Uecker M. Model-based myocardial T1 mapping with sparsity constraints using single-shot inversion-recovery radial FLASH cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2019;21(1):60. https:\/\/doi.org\/10.1186\/s12968-019-0570-3.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"7","key":"6687_CR19","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1002\/acm2.12664","volume":"20","author":"S Chen","year":"2019","unstructured":"Chen S, Hu P, Gu Y, Pang L, Zhang Z, Zhang Y, et al. Impact of patient comfort on diagnostic image quality during PET\/MR exam: A quantitative survey study for clinical workflow management. J Appl Clin Med Phys. 2019;20(7):184\u201392. https:\/\/doi.org\/10.1002\/acm2.12664.","journal-title":"J Appl Clin Med Phys"},{"issue":"Suppl 1","key":"6687_CR20","doi-asserted-by":"publisher","first-page":"P2","DOI":"10.1186\/1532-429X-18-S1-P2","volume":"18","author":"AN Bhuva","year":"2016","unstructured":"Bhuva AN, Nordin S, Bulluck H, Treibel TA, Abdel-Gadir A, Rosmini S, et al. Reproducibility of native T1 mapping using ShMOLLI and MOLLI - implications for sample size calculation. J Cardiovasc Magn Reson. 2016;18(Suppl 1):P2. https:\/\/doi.org\/10.1186\/1532-429X-18-S1-P2.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"6","key":"6687_CR21","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1002\/jmri.27755","volume":"54","author":"B B\u00f6ttcher","year":"2021","unstructured":"B\u00f6ttcher B, Lorbeer R, St\u00f6cklein S, Beller E, Lang CI, Weber MA, et al. Global and Regional Test-Retest Reproducibility of Native T1 and T2 Mapping in Cardiac Magnetic Resonance Imaging. J Magn Reson Imaging. 2021;54(6):1763\u201372. https:\/\/doi.org\/10.1002\/jmri.27755.","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"6687_CR22","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1186\/s12968-014-0069-x","volume":"16","author":"D Dabir","year":"2014","unstructured":"Dabir D, Child N, Kalra A, Rogers T, Gebker R, Jabbour A, et al. Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study. J Cardiovasc Magn Reson. 2014;16(1):69. https:\/\/doi.org\/10.1186\/s12968-014-0069-x.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"6687_CR23","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/1532-429X-16-36","volume":"16","author":"VM Ferreira","year":"2014","unstructured":"Ferreira VM, Piechnik SK, Dall\u2019Armellina E, Karamitsos TD, Francis JM, Ntusi N, et al. Native T1-mapping detects the location, extent and patterns of acute myocarditis without the need for gadolinium contrast agents. J Cardiovasc Magn Reson. 2014;16(1):36. https:\/\/doi.org\/10.1186\/1532-429X-16-36.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"4","key":"6687_CR24","doi-asserted-by":"publisher","first-page":"e190234","DOI":"10.1148\/ryct.2020190234","volume":"2","author":"JJ Pagano","year":"2020","unstructured":"Pagano JJ, Yim D, Lam CZ, Yoo SJ, Seed M, Grosse-Wortmann L. Normative Data for Myocardial Native T1 and Extracellular Volume Fraction in Children. Radiol Cardiothorac Imaging. 2020;2(4):e190234. https:\/\/doi.org\/10.1148\/ryct.2020190234.","journal-title":"Radiol Cardiothorac Imaging"},{"issue":"1","key":"6687_CR25","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/1532-429X-15-13","volume":"15","author":"SK Piechnik","year":"2013","unstructured":"Piechnik SK, Ferreira VM, Lewandowski AJ, Ntusi NA, Banerjee R, Holloway C, et al. Normal variation of magnetic resonance T1 relaxation times in the human population at 1.5 T using ShMOLLI. J Cardiovasc Magn Reson. 2013;15(1):13. https:\/\/doi.org\/10.1186\/1532-429X-15-13.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"10","key":"6687_CR26","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1007\/s10554-018-1371-8","volume":"34","author":"K Lin","year":"2018","unstructured":"Lin K, Suwa K, Ma H, Collins JD, Markl M, Carr JC. Variability of native T1 values: implication for defining regional myocardial changes using MRI. Int J Cardiovasc Imaging. 2018;34(10):1637\u201345. https:\/\/doi.org\/10.1007\/s10554-018-1371-8.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"8476","key":"6687_CR27","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307\u201310.","journal-title":"Lancet"},{"issue":"2","key":"6687_CR28","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Li MY. A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. J Chiropr Med. 2016;15(2):155\u201363. https:\/\/doi.org\/10.1016\/j.jcm.2016.02.012.","journal-title":"J Chiropr Med"},{"key":"6687_CR29","unstructured":"Cohen J. Statistical Power Analysis for the Behavioral Sciences. Rev. ed., Lawrence Erlbaum Associates, 2nd edition, Taylor and Francis; 1988."},{"issue":"1","key":"6687_CR30","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1002\/mrm.20126","volume":"52","author":"SB Reeder","year":"2004","unstructured":"Reeder SB, Herzka DA, McVeigh ER. Signal-to-noise ratio behavior of steady-state free precession. Magn Reson Med. 2004;52(1):123\u201330. https:\/\/doi.org\/10.1002\/mrm.20126.","journal-title":"Magn Reson Med"},{"issue":"3","key":"6687_CR31","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1002\/mrm.26795","volume":"79","author":"B Marty","year":"2018","unstructured":"Marty B, Coppa B, Carlier PG. Fast, precise, and accurate myocardial T1 mapping using a radial MOLLI sequence with FLASH readout. Magn Reson Med. 2018;79(3):1387\u201398. https:\/\/doi.org\/10.1002\/mrm.26795.","journal-title":"Magn Reson Med"},{"issue":"2","key":"6687_CR32","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1002\/jmri.24999","volume":"43","author":"J Shao","year":"2016","unstructured":"Shao J, Rapacchi S, Nguyen KL, Hu P. Myocardial T1 mapping at 3.0 tesla using an inversion recovery spoiled gradient echo readout and bloch equation simulation with slice profile correction (BLESSPC) T1 estimation algorithm. J Magn Reson Imaging. 2016;43(2):414\u201325. https:\/\/doi.org\/10.1002\/jmri.24999.","journal-title":"J Magn Reson Imaging"},{"issue":"1","key":"6687_CR33","doi-asserted-by":"publisher","first-page":"20","DOI":"10.21037\/qims-23-943","volume":"14","author":"A Dalmer","year":"2024","unstructured":"Dalmer A, Meinel FG, B\u00f6ttcher B, Manzke M, Lorbeer R, Weber MA, Bae\u00dfler B, Klemenz AC. Native myocardial T1 mapping: influence of spatial resolution on quantitative results and reproducibility. Quant Imaging Med Surg. 2024;14(1):20\u201330. https:\/\/doi.org\/10.21037\/qims-23-943.","journal-title":"Quant Imaging Med Surg"},{"issue":"1","key":"6687_CR34","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1186\/1532-429X-15-53","volume":"15","author":"F von Knobelsdorff-Brenkenhoff","year":"2013","unstructured":"von Knobelsdorff-Brenkenhoff F, Prothmann M, Dieringer MA, Wassmuth R, Greiser A, Schwenke C, Niendorf T, Schulz-Menger J. Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications. J Cardiovasc Magn Reson. 2013;15(1):53. https:\/\/doi.org\/10.1186\/1532-429X-15-53.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"3","key":"6687_CR35","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1016\/j.jcmg.2019.05.019","volume":"13","author":"S Nakamori","year":"2020","unstructured":"Nakamori S, Fahmy A, Jang J, El-Rewaidy H, Neisius U, Berg S, et al. Changes in Myocardial Native T1 and T2 After Exercise Stress: A Noncontrast CMR Pilot Study. JACC Cardiovasc Imaging. 2020;13(3):667\u201380. https:\/\/doi.org\/10.1016\/j.jcmg.2019.05.019.","journal-title":"JACC Cardiovasc Imaging"},{"issue":"4","key":"6687_CR36","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1161\/hc0402.102975","volume":"105","author":"MD Cerqueira","year":"2002","unstructured":"Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK, American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105(4):539\u201342. https:\/\/doi.org\/10.1161\/hc0402.102975.","journal-title":"Circulation"},{"issue":"6","key":"6687_CR37","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1017\/S1047951121003292","volume":"32","author":"H Oka","year":"2022","unstructured":"Oka H, Nakau K, Nakagawa S, Kobayashi Y, Imanishi R, Iwata K, et al. Comparison of myocardial T1 mapping during breath-holding and free-breathing. Cardiol Young. 2022;32(6):925\u20139. https:\/\/doi.org\/10.1017\/S1047951121003292.","journal-title":"Cardiol Young"},{"issue":"1","key":"6687_CR38","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1007\/s10334-022-01032-4","volume":"36","author":"J Ludwig","year":"2023","unstructured":"Ludwig J, Kerkering KM, Speier P, Schaeffter T, Kolbitsch C. Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping. MAGMA. 2023;36(1):135\u201350. https:\/\/doi.org\/10.1007\/s10334-022-01032-4.","journal-title":"MAGMA"},{"key":"6687_CR39","unstructured":"Hallett Reid S, Toro F, Ashurst JV. Physiology, Tidal Volume. In: StatPearls. Treasure Island (FL): StatPearls Publishing; 2023. https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK482502\/."},{"issue":"5","key":"6687_CR40","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1002\/mrm.1910330517","volume":"33","author":"Y Wang","year":"1995","unstructured":"Wang Y, Riederer SJ, Ehman RL. Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging. Magn Reson Med. 1995;33(5):713\u20139. https:\/\/doi.org\/10.1002\/mrm.1910330517.","journal-title":"Magn Reson Med"},{"issue":"3","key":"6687_CR41","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1002\/mrm.28506","volume":"85","author":"R Guo","year":"2021","unstructured":"Guo R, Cai X, Kucukseymen S, Rodriguez J, Paskavitz A, Pierce P, et al. Free-breathing simultaneous myocardial T1 and T2 mapping with whole left ventricle coverage. Magn Reson Med. 2021;85(3):1308\u201321. https:\/\/doi.org\/10.1002\/mrm.28506.","journal-title":"Magn Reson Med"},{"issue":"4","key":"6687_CR42","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1002\/mrm.27811","volume":"82","author":"H Qi","year":"2019","unstructured":"Qi H, Jaubert O, Bustin A, Cruz G, Chen H, Botnar R, Prieto C. Free-running 3D whole heart myocardial T1 mapping with isotropic spatial resolution. Magn Reson Med. 2019;82(4):1331\u201342. https:\/\/doi.org\/10.1002\/mrm.27811.","journal-title":"Magn Reson Med"},{"issue":"4","key":"6687_CR43","doi-asserted-by":"publisher","first-page":"2450","DOI":"10.1002\/mrm.27574","volume":"81","author":"JL Shaw","year":"2019","unstructured":"Shaw JL, Yang Q, Zhou Z, Deng Z, Nguyen C, Li D, et al. Free-breathing, non-ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking. Magn Reson Med. 2019;81(4):2450\u201363. https:\/\/doi.org\/10.1002\/mrm.27574.","journal-title":"Magn Reson Med"},{"issue":"4","key":"6687_CR44","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1002\/mrm.29521","volume":"89","author":"X Wang","year":"2023","unstructured":"Wang X, Rosenzweig S, Roeloffs V, Blumenthal M, Scholand N, Tan Z, et al. Free-breathing myocardial T1 mapping using inversion-recovery radial FLASH and motion-resolved model-based reconstruction. Magn Reson Med. 2023;89(4):1368\u201384. https:\/\/doi.org\/10.1002\/mrm.29521.","journal-title":"Magn Reson Med"},{"issue":"4","key":"6687_CR45","doi-asserted-by":"publisher","first-page":"1748","DOI":"10.1002\/mrm.29351","volume":"88","author":"T Cao","year":"2022","unstructured":"Cao T, Wang N, Kwan AC, Lee HL, Mao X, Xie Y, et al. Free-breathing, non-ECG, simultaneous myocardial T1, T2, T2 *, and fat-fraction mapping with motion-resolved cardiovascular MR multitasking. Magn Reson Med. 2022;88(4):1748\u201363. https:\/\/doi.org\/10.1002\/mrm.29351.","journal-title":"Magn Reson Med"},{"key":"6687_CR46","doi-asserted-by":"publisher","first-page":"833257","DOI":"10.3389\/fcvm.2022.833257","volume":"4","author":"X Mao","year":"2022","unstructured":"Mao X, Lee HL, Hu Z, Cao T, Han F, Ma S, et al. Simultaneous Multi-Slice Cardiac MR Multitasking for Motion-Resolved, Non-ECG, Free-Breathing T1-T2 Mapping. Front Cardiovasc Med. 2022;4:9:833257. https:\/\/doi.org\/10.3389\/fcvm.2022.833257.","journal-title":"Front Cardiovasc Med"},{"issue":"1","key":"6687_CR47","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/1532-429X-15-63","volume":"15","author":"P Kellman","year":"2013","unstructured":"Kellman P, Herzka DA, Arai AE, Hansen MS. Influence of Off-resonance in myocardial T1-mapping using SSFP based MOLLI method. J Cardiovasc Magn Reson. 2013;15(1):63. https:\/\/doi.org\/10.1186\/1532-429X-15-63.","journal-title":"J Cardiovasc Magn Reson"},{"issue":"1","key":"6687_CR48","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1007\/s10334-017-0631-2","volume":"31","author":"D Cameron","year":"2018","unstructured":"Cameron D, Vassiliou VS, Higgins DM, Gatehouse PD. Towards accurate and precise T 1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions. MAGMA. 2018;31(1):143\u201363. https:\/\/doi.org\/10.1007\/s10334-017-0631-2.","journal-title":"MAGMA"},{"issue":"4","key":"6687_CR49","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1002\/mrm.26223","volume":"77","author":"J Shao","year":"2017","unstructured":"Shao J, Rashid S, Renella P, Nguyen KL, Hu P. Myocardial T1 mapping for patients with implanted cardiac devices using wideband inversion recovery spoiled gradient echo readout. Magn Reson Med. 2017;77(4):1495\u2013504. https:\/\/doi.org\/10.1002\/mrm.26223.","journal-title":"Magn Reson Med"},{"issue":"9","key":"6687_CR50","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1177\/02841851251332461","volume":"66","author":"NC Garster","year":"2025","unstructured":"Garster NC, Koch K, Ibrahim EH, Rubenstein JC. Comparison of GRE versus SSFP-based cardiac T1-mapping in device patients. Acta Radiol. 2025;66(9):929\u201334. https:\/\/doi.org\/10.1177\/02841851251332461.","journal-title":"Acta Radiol"}],"container-title":["BMC Cardiovascular Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12872-026-06687-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-026-06687-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12872-026-06687-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T23:02:47Z","timestamp":1790377367000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12872-026-06687-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,23]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6687"],"URL":"https:\/\/doi.org\/10.1186\/s12872-026-06687-8","relation":{},"ISSN":["1471-2261"],"issn-type":[{"value":"1471-2261","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,23]]},"assertion":[{"value":"10 June 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the local ethics committee (Ethics Committee of the Medical Faculty, University hospital D\u00fcsseldorf, study number 2023\u20132336) and conducted in accordance with the principles of the Declaration of Helsinki. Informed consent was obtained from all subjects included in the study.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dirk Voit and Jens Frahm are co-inventors of a patent including the rapid T1FLASH technique. All other authors declare that they have no conflict of interest.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"842"}}