{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T18:52:10Z","timestamp":1791226330391,"version":"4.1.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:00:00Z","timestamp":1783382400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T00:00:00Z","timestamp":1791158400000},"content-version":"vor","delay-in-days":90,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Emerg Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Emergency Department (ED) evaluation of patients presenting with mild head trauma or acute neurological symptoms is common and often requires rapid exclusion of intracranial pathology. Although computed tomography (CT) is the diagnostic reference standard, its widespread use raises concerns regarding radiation exposure, cost, and ED workflow efficiency. TES HT100 is a portable, non-invasive radiofrequency-based device intended to assist early triage decisions. We report the prespecified interim analysis of a prospective validation study conducted in an ED population.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Between December 2024 and January 2026, adult patients were enrolled at the Emergency Department of Pineta Grande Hospital, Castel Volturno, Italy. In this single-center, blinded diagnostic accuracy study, participants were included in two predefined cohorts: mild head trauma and non-traumatic acute neurological symptoms. TES HT100 provides a binary output and was compared with radiologist-interpreted head CT as the reference standard. Sensitivity, specificity, predictive values, likelihood ratios, accuracy, and balanced accuracy were calculated with 95% confidence intervals. Additional exploratory analyses stratified CT findings into acute clinically relevant abnormalities and chronic\/incidental intracranial abnormalities without changing the prespecified primary endpoint. Robustness analyses assessed the impact of excluded or non-evaluable cases. Trial registration: ClinicalTrials.gov Identifier NCT07490418, registered on 23 March 2026.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The interim analysis included 301 patients (151 trauma; 150 neurological symptoms). CT-positive prevalence was 52.2%, consistent with the CT-imaged Emergency Department population and the protocol-defined broad intracranial abnormality endpoint. Overall sensitivity was 96.2% (95% CI 91.9\u201398.2), specificity 82.6% (75.6\u201388.0), PPV 85.8%, NPV 95.2%, and accuracy 89.7%. The positive likelihood ratio was 5.54 and the negative likelihood ratio 0.05. Exploratory category-specific analyses showed sensitivity and NPV of 96.6% and 98.4%, respectively, for acute clinically relevant abnormalities, and 96.0% and 96.0%, respectively, for chronic\/incidental abnormalities. Specificity was lower in the acute-target analysis (50.6%), supporting interpretation of TES HT100 as a structural-abnormality triage signal rather than a lesion-specific acute-pathology classifier.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In this interim evaluation, TES HT100 demonstrated high sensitivity and a low negative likelihood ratio compared with CT in ED patients with head trauma or acute neurological symptoms. These findings support further evaluation of TES HT100 as a triage-support adjunct in CT-imaged ED populations. Exploratory acute\/chronic analyses provide additional clinical context but should not be interpreted as evidence of lesion-specific performance for acute abnormalities or as justification for replacing CT.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12873-026-01676-8","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T08:46:44Z","timestamp":1783414004000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Prospective blinded interim evaluation of a portable radiofrequency device TES HT to support triage in emergency department patients with mild head trauma or acute neurological symptoms"],"prefix":"10.1186","volume":"26","author":[{"given":"Adriana Modestina","family":"Conte","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrizio","family":"Alfieri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angelo","family":"Localzo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esa\u00f9","family":"Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iole","family":"Cucinotto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessandro","family":"Trovato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riccardo","family":"Gualtieri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ettore","family":"Laccetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonia","family":"Sorbo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,7]]},"reference":[{"issue":"4","key":"1676_CR1","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.3171\/2017.10.JNS17352","volume":"130","author":"MC Dewan","year":"2018","unstructured":"Dewan MC, Rattani A, Gupta S, Baticulon RE, Hung YC, Punchak M, et al. Estimating the global incidence of traumatic brain injury. J Neurosurg. 2018;130(4):1080\u201397.","journal-title":"J Neurosurg"},{"issue":"10","key":"1676_CR2","doi-asserted-by":"publisher","first-page":"1411","DOI":"10.1089\/neu.2015.4126","volume":"38","author":"A Brazinova","year":"2021","unstructured":"Brazinova A, Rehorcikova V, Taylor MS, Buckova V, Majdan M, Psota M, et al. Epidemiology of traumatic brain injury in Europe: a living systematic review. J Neurotrauma. 2021;38(10):1411\u201340.","journal-title":"J Neurotrauma"},{"issue":"20 Suppl 2","key":"1676_CR3","first-page":"S6","volume":"97","author":"V Saini","year":"2021","unstructured":"Saini V, Guada L, Yavagal DR. Global epidemiology of stroke and access to acute ischemic stroke interventions. Neurology. 2021;97(20 Suppl 2):S6\u201316.","journal-title":"Neurology"},{"issue":"1","key":"1676_CR4","doi-asserted-by":"publisher","first-page":"e0293558","DOI":"10.1371\/journal.pone.0293558","volume":"19","author":"M Saran","year":"2024","unstructured":"Saran M, Arab-Zozani M, Behzadifar M, Gholami M, Azari S, Bragazzi NL, et al. Overuse of computed tomography for mild head injury: a systematic review and meta-analysis. PLoS ONE. 2024;19(1):e0293558.","journal-title":"PLoS ONE"},{"issue":"22","key":"1676_CR5","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","volume":"357","author":"DJ Brenner","year":"2007","unstructured":"Brenner DJ, Hall EJ. Computed tomography\u2014an increasing source of radiation exposure. N Engl J Med. 2007;357(22):2277\u201384.","journal-title":"N Engl J Med"},{"issue":"2","key":"1676_CR6","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.annemergmed.2008.03.014","volume":"52","author":"NR Hoot","year":"2008","unstructured":"Hoot NR, Aronsky D. Systematic review of emergency department crowding: causes, effects, and solutions. Ann Emerg Med. 2008;52(2):126\u2013e361.","journal-title":"Ann Emerg Med"},{"issue":"9266","key":"1676_CR7","doi-asserted-by":"publisher","first-page":"1391","DOI":"10.1016\/S0140-6736(00)04561-X","volume":"357","author":"IG Stiell","year":"2001","unstructured":"Stiell IG, Wells GA, Vandemheen K, Clement C, Lesiuk H, Laupacis A, et al. The Canadian CT Head Rule for patients with minor head injury. Lancet. 2001;357(9266):1391\u20136.","journal-title":"Lancet"},{"issue":"2","key":"1676_CR8","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1056\/NEJM200007133430204","volume":"343","author":"MJ Haydel","year":"2000","unstructured":"Haydel MJ, Preston CA, Mills TJ, Luber S, Blaudeau E, DeBlieux PMC. Indications for computed tomography in patients with minor head injury. N Engl J Med. 2000;343(2):100\u20135.","journal-title":"N Engl J Med"},{"issue":"10","key":"1676_CR9","doi-asserted-by":"publisher","first-page":"191","DOI":"10.21474\/IJAR01\/17695","volume":"11","author":"S Vaia","year":"2023","unstructured":"Vaia S, Iavarone A, Caterino F, et al. HT temnography in the early diagnosis of brain lesions due to ischemic or hemorrhagic stroke. Int J Adv Res. 2023;11(10):191\u20135.","journal-title":"Int J Adv Res"},{"key":"1676_CR10","doi-asserted-by":"publisher","first-page":"313","DOI":"10.2147\/OAEM.S475328","volume":"16","author":"S Montemerani","year":"2024","unstructured":"Montemerani S, Fabrizi S, Alfieri F, et al. Reliability evaluation of temnography for early detection of intracranial lesions in mild traumatic brain injury patient: a preliminary report of a new portable, non-invasive device. Open Access Emerg Med. 2024;16:313\u201321.","journal-title":"Open Access Emerg Med"},{"key":"1676_CR11","unstructured":"National Institute for Health and Care Excellence. Head injury: assessment and early management. NICE guideline NG232. London: National Institute for Health and Care Excellence; 2023 May 18."},{"issue":"7458","key":"1676_CR12","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1136\/bmj.329.7458.168","volume":"329","author":"JJ Deeks","year":"2004","unstructured":"Deeks JJ, Altman DG. Diagnostic tests 4: likelihood ratios. BMJ. 2004;329(7458):168\u20139.","journal-title":"BMJ"},{"key":"1676_CR13","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1186\/s12873-023-00806-w","volume":"23","author":"S Pearce","year":"2023","unstructured":"Pearce S, et al. Emergency department crowding: an overview of reviews describing measures, causes, and harms. BMC Emerg Med. 2023;23:32.","journal-title":"BMC Emerg Med"}],"container-title":["BMC Emergency Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12873-026-01676-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12873-026-01676-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12873-026-01676-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T18:02:47Z","timestamp":1791223367000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12873-026-01676-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,7]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1676"],"URL":"https:\/\/doi.org\/10.1186\/s12873-026-01676-8","relation":{},"ISSN":["1471-227X"],"issn-type":[{"value":"1471-227X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,7]]},"assertion":[{"value":"25 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The TESCO study (CLV-01-TES HT, protocol version 1.1 for the interim phase) was approved by Comitato Etico Campania 3 (opinion CLV-01-TES HT; minutes no. 10\/24 dated 24 June 2024; Protocol No. 00026087 dated 23 July 2024). The study was conducted in accordance with the Declaration of Helsinki and applicable regulatory requirements. Written informed consent was obtained from all participants prior to enrollment. The study was registered on ClinicalTrials.gov (Identifier: NCT07490418; registered on 23 March 2026).","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"FA is an employee of B&B s.r.l. and is responsible for the clinical development and regulatory activities related to TES HT100. B&B s.r.l. sponsored the study and holds intellectual property rights, including patents, related to the investigated device\/technology. IC received consultancy fees from B&B s.r.l. for scientific support in the analysis and interpretation of the study data. All remaining authors declare that they have no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"259"}}