{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T14:49:14Z","timestamp":1780411754862,"version":"3.54.1"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T00:00:00Z","timestamp":1573516800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T00:00:00Z","timestamp":1573516800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Gastroenterol"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Current magnet-controlled capsule endoscopy (MCE) for the stomach is not yet satisfactory with respect to navigation control, especially in the gastric fundus and cardia. A newly developed MCE system conducted in a standing rather than supine position may improve capsule maneuverability within the stomach. The aim of this phase 1 study was to assess the feasibility and safety of this system for examining the human stomach in healthy volunteers.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>A cohort of 31 healthy volunteers were enrolled. Each swallowed a capsule after drinking water and gas producing agents intended to produce distention. Under the newly developed standing MCE system, subjects were examined endoscopically while standing with external guide magnets placed on the abdominal wall and left lower chest. Safety, gastric preparation, maneuverability, visualization of anatomical landmarks and the gastric mucosa, and examination time were the primary parameters assessed. The gastric preparation and examination procedures were well accepted by the subjects and there were no adverse events.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>Gastric examination took 27.8\u2009\u00b1\u20098.3\u2009min (12\u201345\u2009min). Gastric cleanliness was good in 24 participants (77.4%) and moderate in 7 participants (22.6%). Gastric distention was good in all of 31 participants (100%). Capsule maneuverability was also graded as good in all 31 subjects (100%), and manipulation in the fundus and cardia regions was as easy as that in the antrum and body. Visualization of the gastric cardia, fundus, body, angulus, antrum and pylorus was assessed subjectively as complete in all 31 subjects (100%). Visualization of the gastric mucosa was also good (&gt;\u200975%) in all 31 subjects (100%). In areas where the mucosa could not be visualized, the low visibility was due to opaque fluid or foam. Polyps and erosive lesions were found in 25 subjects.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>MCE of the stomach conducted in a standing position is feasible and safe with satisfactory maneuverability.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12876-019-1101-2","type":"journal-article","created":{"date-parts":[[2019,11,12]],"date-time":"2019-11-12T16:03:06Z","timestamp":1573574586000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Human gastric magnet-controlled capsule endoscopy conducted in a standing position: the phase 1 study"],"prefix":"10.1186","volume":"19","author":[{"given":"Chun-sheng","family":"Cheng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting-ji","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8680-0073","authenticated-orcid":false,"given":"Hou-de","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,12]]},"reference":[{"issue":"6785","key":"1101_CR1","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1038\/35013140","volume":"405","author":"G Iddan","year":"2000","unstructured":"Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy. Nature. 2000;405(6785):417.","journal-title":"Nature."},{"key":"1101_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.giec.2003.10.022","volume":"14","author":"GJ Iddan","year":"2004","unstructured":"Iddan GJ, Swain CP. History and development of capsule endoscopy. Gastrointest Endosc Clin N Am. 2004;14:1\u20139.","journal-title":"Gastrointest Endosc Clin N Am"},{"key":"1101_CR3","volume-title":"Atlas of Video Capsule Endoscopy","author":"G Iddan","year":"2006","unstructured":"Iddan G. A short history of the gastrointetinal capsule. In: Heuchel M, Hagenm \u00dcller F, Fleisher D, editors. Atlas of Video Capsule Endoscopy. Heideberg: Springer: 2\u20133; 2006."},{"key":"1101_CR4","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1067\/mge.2000.105724","volume":"51","author":"F Gong","year":"2000","unstructured":"Gong F, Swain P, Mills T. Wireless endoscopy. Gastrointest Endosc. 2000;51:725\u20139.","journal-title":"Gastrointest Endosc"},{"key":"1101_CR5","doi-asserted-by":"publisher","first-page":"1290","DOI":"10.1016\/j.gie.2010.01.064","volume":"71","author":"P Swain","year":"2010","unstructured":"Swain P, Toor A, Volke F, Keller J, Gerber J, Rabinovitz E, Rothstein RI. Remote magnetic manipulation of a wireless capsule endoscope in the esophagus and stomach of humans (with videos). Gastrointest Endosc. 2010;71:1290\u20133.","journal-title":"Gastrointest Endosc"},{"key":"1101_CR6","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.gie.2010.08.053","volume":"73","author":"J Keller","year":"2011","unstructured":"Keller J, Fibbe C, Volke F, Gerber J, Mosse A, Reimann-Zawadzk M, Rabinovitz E, Layer P, Schmitt D. Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers (with videos). Gastrointest Endosc. 2011;73:22\u20138.","journal-title":"Gastrointest Endosc"},{"key":"1101_CR7","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1016\/j.gie.2015.09.015","volume":"83","author":"I Rahman","year":"2016","unstructured":"Rahman I, Pioche M, Shim C, Lee S, Sung I, Saurin J, Patel P. Magnet-assisted capsule endoscopy in the upper GI tract by using a novel navigation system (with video). Gastrointest Endosc. 2016;83:889\u201395.","journal-title":"Gastrointest Endosc"},{"key":"1101_CR8","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1097\/MEG.0000000000000312","volume":"27","author":"I Rahman","year":"2014","unstructured":"Rahman I, Kay M, Bryant T, Pelitari S, Salter S, Dimitrov B, Patel P. Optimizing the performance of magnetic-assisted capsule endoscopy of the upper GI tract using multiplanar CT modelling. Eur J Gastroenterol Hepatol. 2014;27:460\u20136.","journal-title":"Eur J Gastroenterol Hepatol"},{"key":"1101_CR9","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1055\/s-0030-1255521","volume":"42","author":"J Rey","year":"2010","unstructured":"Rey J, Ogata H, Hosoe N, Ohtsuka K, Ogata N, Ikeda K, Aihara H, Pangtay I, Hibi T, Kudo S. Feasibility of stomach exploration with a guided capsule endoscope. Endoscopy. 2010;42:541\u20135.","journal-title":"Endoscopy."},{"key":"1101_CR10","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1016\/j.gie.2011.09.030","volume":"75","author":"J Rey","year":"2012","unstructured":"Rey J, Ogata H, Hosoe N, Ohtsuka K, Ogata N, Ikeda K, Aihara H, Pangtay I, Hibi T, Kudo S. Blinded nonrandomized comparative study of gastric examination with a magnetically guided capsule endoscope and standard video endoscope. Gastrointest Endosc. 2012;75:373\u201381.","journal-title":"Gastrointest Endosc"},{"key":"1101_CR11","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1097\/MCG.0000000000000110","volume":"49","author":"U Denzer","year":"2015","unstructured":"Denzer U, R\u00f6ch T, Hoytat B, Abdel-Hamid M, Hebuterne X, Vanbiervielt G, Filippi J, Ogata H, Hosoe N, Ohtsuka K. Magnetically guided capsule versus conventional gastroscopy for upper abdominal complaints: a prospective blinded study. J Clin Gastroenterol. 2015;49:101\u20137.","journal-title":"J Clin Gastroenterol"},{"key":"1101_CR12","doi-asserted-by":"publisher","first-page":"155","DOI":"10.4161\/jig.23751","volume":"2","author":"Z Liao","year":"2012","unstructured":"Liao Z, Duan X, Xin L, Bo L, Wang X, Xiao G, Hu L, Zhuang S, Li Z. Feasibility and safety of magnetic controlled capsule endoscopy system in examination of human stomach: a pilot study in healthy volunteers. J Interv Gastroenterol. 2012;2:155\u201360.","journal-title":"J Interv Gastroenterol"},{"issue":"9","key":"1101_CR13","doi-asserted-by":"publisher","first-page":"1266","DOI":"10.1016\/j.cgh.2016.05.013","volume":"14","author":"Z Liao","year":"2016","unstructured":"Liao Z, Hou X, Lin-Hu EQ, Sheng JQ, Ge ZZ, Jiang B, Hou XH, Liu JY, Li Z, Huang QY. Accuracy of magnetically controlled capsule endoscopy, compared with conventional gastroscopy in detection of gastric diseases. Clin Gastroenterol Hepatol. 2016;14(9):1266\u201373.","journal-title":"Clin Gastroenterol Hepatol"},{"issue":"4","key":"1101_CR14","doi-asserted-by":"publisher","first-page":"1937","DOI":"10.1007\/s00464-017-5887-0","volume":"32","author":"GS Lien","year":"2018","unstructured":"Lien GS, Wu MS, Chen CN, Liu CW, Suk FM. Feasibility and safety of a novel magnetic-assisted capsule endoscope system in a preliminary examination for upper gastrointestinal tract. Surg Endosc. 2018;32(4):1937\u201344.","journal-title":"Surg Endosc"}],"container-title":["BMC Gastroenterology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12876-019-1101-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12876-019-1101-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12876-019-1101-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,11]],"date-time":"2020-11-11T00:16:29Z","timestamp":1605053789000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcgastroenterol.biomedcentral.com\/articles\/10.1186\/s12876-019-1101-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,12]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1101"],"URL":"https:\/\/doi.org\/10.1186\/s12876-019-1101-2","relation":{},"ISSN":["1471-230X"],"issn-type":[{"value":"1471-230X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,12]]},"assertion":[{"value":"18 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Ethics Committee of Shenzhen Sixth People\u2019s Hospital (2018\u2013043) and also registered on the website: .(CHiCTR1800018824). The first volunteer was recruited in Octorber 2018.The study wan performed in accordance with the Declaration of Helsinki. Written informed consent was obtained from all the participants.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent for publication of their clinical details was obtained from the participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"184"}}