{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T01:46:20Z","timestamp":1787535980819,"version":"build-2736575974"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,20]],"date-time":"2020-10-20T00:00:00Z","timestamp":1603152000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,20]],"date-time":"2020-10-20T00:00:00Z","timestamp":1603152000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Infect Dis"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A cost effective and efficient diagnostic tool for COVID-19 as near to the point of care (PoC) as possible would be a game changer in the current pandemic. We tested reverse transcription loop mediated isothermal amplification (RT-LAMP), a method which can produce results in under 30\u2009min, alongside standard methods in a real-life clinical setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective service improvement project piloted an RT-LAMP method on nasal and pharyngeal swabs on 21 residents of a high dependency care home, with two index COVID-19 cases, and compared it to multiplex tandem reverse transcription polymerase chain reaction (RT-PCR). We recorded vital signs of patients to correlate clinical and laboratory information and calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of a single swab using RT-LAMP compared with the current standard, RT-PCR, as per Standards for Reporting Diagnostic Accuracy Studies (STARD) guidelines.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The novel method accurately detected 8\/10 RT-PCR positive cases and identified a further 3 positive cases. Eight further cases were negative using both methods. Using repeated RT-PCR as a \u201cgold standard\u201d, the sensitivity and specificity of a single novel test were 80 and 73% respectively. PPV was 73% and NPV was 83%. Incorporating retesting of low signal RT-LAMP positives improved the specificity to 100%. We also speculate that hypothermia may be a significant early clinical sign of COVID-19.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>RT-LAMP testing for SARS-CoV-2 was found to be promising, fast and to work equivalently to RT-PCR methods. RT-LAMP has the potential to transform COVID-19 detection, bringing rapid and accurate testing to the PoC. RT-LAMP could be deployed in mobile community testing units, care homes and hospitals to detect disease early and prevent spread.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12879-020-05484-8","type":"journal-article","created":{"date-parts":[[2020,10,20]],"date-time":"2020-10-20T09:02:56Z","timestamp":1603184576000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Detecting SARS-CoV-2 at point of care: preliminary data comparing loop-mediated isothermal amplification (LAMP) to polymerase chain reaction (PCR)"],"prefix":"10.1186","volume":"20","author":[{"given":"Marc F.","family":"\u00d6sterdahl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karla A.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary Ni","family":"Lochlainn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stuart","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sam","family":"Douthwaite","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel","family":"Horsfall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alyce","family":"Sheedy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon D.","family":"Goldenberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Stanley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim D.","family":"Spector","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4910-0489","authenticated-orcid":false,"given":"Claire J.","family":"Steves","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,20]]},"reference":[{"key":"5484_CR1","doi-asserted-by":"publisher","first-page":"m1403","DOI":"10.1136\/bmj.m1403","volume":"369","author":"NJ Beeching","year":"2020","unstructured":"Beeching NJ, Fletcher TE, Beadsworth MBJ. Covid-19: testing times. BMJ. 2020;369:m1403. https:\/\/doi.org\/10.1136\/bmj.m1403 published Online First: 2020\/04\/10.","journal-title":"BMJ"},{"key":"5484_CR2","doi-asserted-by":"publisher","unstructured":"El-Tholoth M, Bau HH, Song J. A single and two-stage, closed-tube, molecular test for the 2019 novel coronavirus (COVID-19) at home, clinic, and points of entry. ChemRxiv. 2020. https:\/\/doi.org\/10.26434\/chemrxiv.11860137.v1.","DOI":"10.26434\/chemrxiv.11860137.v1"},{"issue":"6","key":"5484_CR3","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0234682","volume":"15","author":"LE Lamb","year":"2020","unstructured":"Lamb LE, Bartolone SN, Ward E, et al. Rapid detection of novel coronavirus\/severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by reverse transcription-loop-mediated isothermal amplification. PLoS One. 2020;15(6):e0234682. https:\/\/doi.org\/10.1371\/journal.pone.0234682.","journal-title":"PLoS One"},{"key":"5484_CR4","doi-asserted-by":"publisher","unstructured":"Zhang Y, Odiwuor N, Xiong J, et al. Rapid molecular detection of SARS-CoV-2 (COVID-19) virus RNA using colorimetric LAMP. medRxiv. 2020:2020.02.26.20028373. https:\/\/doi.org\/10.1101\/2020.02.26.20028373.","DOI":"10.1101\/2020.02.26.20028373"},{"issue":"7","key":"5484_CR5","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1093\/clinchem\/hvaa102","volume":"66","author":"L Yu","year":"2020","unstructured":"Yu L, Wu S, Hao X, et al. Rapid detection of COVID-19 coronavirus using a reverse transcriptional loop-mediated isothermal amplification (RT-LAMP) diagnostic platform. Clin Chem. 2020;66(7):975\u20137. https:\/\/doi.org\/10.1093\/clinchem\/hvaa102.","journal-title":"Clin Chem"},{"key":"5484_CR6","doi-asserted-by":"publisher","unstructured":"Yang W, Dang X, Wang Q, et al. Rapid detection of SARS-CoV-2 using reverse transcription RT-LAMP method. medRxiv. 2020:2020.03.02.20030130. https:\/\/doi.org\/10.1101\/2020.03.02.20030130.","DOI":"10.1101\/2020.03.02.20030130"},{"issue":"6","key":"5484_CR7","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/j.cmi.2020.04.001","volume":"26","author":"C Yan","year":"2020","unstructured":"Yan C, Cui J, Huang L, et al. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay. Clin Microbiol Infect. 2020;26(6):773\u20139. https:\/\/doi.org\/10.1016\/j.cmi.2020.04.001.","journal-title":"Clin Microbiol Infect"},{"issue":"1","key":"5484_CR8","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1186\/s12906-016-1479-0","volume":"16","author":"JK Woo","year":"2016","unstructured":"Woo JK, Choi S, Kang JH, et al. Fermented barley and soybean (BS) mixture enhances intestinal barrier function in dextran sulfate sodium (DSS)-induced colitis mouse model. BMC Complement Altern Med. 2016;16(1):498. https:\/\/doi.org\/10.1186\/s12906-016-1479-0 published Online First: 2016\/12\/04.","journal-title":"BMC Complement Altern Med"},{"issue":"13","key":"5484_CR9","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1001\/jama.2020.2648","volume":"323","author":"Z Wu","year":"2020","unstructured":"Wu Z, McGoogan JM. Characteristics of and important lessons from the coronavirus disease 2019 (COVID-19) outbreak in China: summary of a report of 72 314 cases from the Chinese Center for Disease Control and Prevention. JAMA. 2020;323(13):1239\u201342. https:\/\/doi.org\/10.1001\/jama.2020.2648.","journal-title":"JAMA"},{"issue":"1","key":"5484_CR10","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1039\/c5fo00853k","volume":"7","author":"A Cuervo","year":"2016","unstructured":"Cuervo A, Hevia A, Lopez P, et al. Phenolic compounds from red wine and coffee are associated with specific intestinal microorganisms in allergic subjects. Food Funct. 2016;7(1):104\u20139. https:\/\/doi.org\/10.1039\/c5fo00853k published Online First: 2015\/10\/06.","journal-title":"Food Funct"},{"issue":"1","key":"5484_CR11","doi-asserted-by":"publisher","first-page":"62","DOI":"10.3945\/ajcn.110.000075","volume":"93","author":"X Tzounis","year":"2011","unstructured":"Tzounis X, Rodriguez-Mateos A, Vulevic J, et al. Prebiotic evaluation of cocoa-derived flavanols in healthy humans by using a randomized, controlled, double-blind, crossover intervention study. Am J Clin Nutr. 2011;93(1):62\u201372. https:\/\/doi.org\/10.3945\/ajcn.110.000075 published Online First: 2010\/11\/12.","journal-title":"Am J Clin Nutr"},{"issue":"12","key":"5484_CR12","doi-asserted-by":"publisher","first-page":"7577","DOI":"10.1007\/s13197-015-1921-1","volume":"52","author":"KR Pandey","year":"2015","unstructured":"Pandey KR, Naik SR, Vakil BV. Probiotics, prebiotics and synbiotics- a review. J Food Sci Technol. 2015;52(12):7577\u201387. https:\/\/doi.org\/10.1007\/s13197-015-1921-1 published Online First: 2015\/11\/26.","journal-title":"J Food Sci Technol"},{"key":"5484_CR13","doi-asserted-by":"publisher","unstructured":"Jiang M, Pan W, Arasthfer A, et al. Development and validation of a rapid, single-step reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) system potentially to be used for reliable and high-throughput screening of COVID-19. Front Cell Infect Microbiol. 2020:10(331). https:\/\/doi.org\/10.3389\/fcimb.2020.00331.","DOI":"10.3389\/fcimb.2020.00331"},{"key":"5484_CR14","doi-asserted-by":"publisher","unstructured":"Buck MD, Poirier EZ, Cardoso A, et al. Standard operating procedures for SARS-CoV-2 detection by a clinical diagnostic RT-LAMP assay. medRxiv. 2020:2020.06.29.20142430. https:\/\/doi.org\/10.1101\/2020.06.29.20142430.","DOI":"10.1101\/2020.06.29.20142430"},{"issue":"6","key":"5484_CR15","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1016\/j.jmoldx.2020.03.006","volume":"22","author":"G-S Park","year":"2020","unstructured":"Park G-S, Ku K, Baek S-H, et al. Development of reverse transcription loop-mediated isothermal amplification assays targeting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). J Mol Diagn. 2020;22(6):729\u201335. https:\/\/doi.org\/10.1016\/j.jmoldx.2020.03.006.","journal-title":"J Mol Diagn"},{"issue":"11","key":"5484_CR16","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2016-012799","volume":"6","author":"JF Cohen","year":"2016","unstructured":"Cohen JF, Korevaar DA, Altman DG, et al. STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration. BMJ Open. 2016;6(11):e012799. https:\/\/doi.org\/10.1136\/bmjopen-2016-012799.","journal-title":"BMJ Open"},{"key":"5484_CR17","doi-asserted-by":"publisher","unstructured":"Sivamaruthi BS, Kesika P, Chaiyasut C. Impact of fermented foods on human cognitive function-a review of outcome of clinical trials. Sci Pharm. 2018;86(2). https:\/\/doi.org\/10.3390\/scipharm86020022 published Online First: 2018\/06\/03.","DOI":"10.3390\/scipharm86020022"},{"key":"5484_CR18","doi-asserted-by":"publisher","unstructured":"Ai T, Yang Z, Hou H, et al. Correlation of chest CT and RT-PCR testing in coronavirus disease 2019 (COVID-19) in China: a report of 1014 cases. Radiology. 2020:200642. https:\/\/doi.org\/10.1148\/radiol.2020200642 published Online First: 2020\/02\/27.","DOI":"10.1148\/radiol.2020200642"},{"key":"5484_CR19","doi-asserted-by":"publisher","unstructured":"Yang Y, Yang M, Shen C, et al. Evaluating the accuracy of different respiratory specimens in the laboratory diagnosis and monitoring the viral shedding of 2019-nCoV infections. medRxiv. 2020:2020.02.11.20021493. https:\/\/doi.org\/10.1101\/2020.02.11.20021493.","DOI":"10.1101\/2020.02.11.20021493"},{"issue":"6","key":"5484_CR20","doi-asserted-by":"publisher","first-page":"R271-R71","DOI":"10.1186\/cc13106","volume":"17","author":"S Kushimoto","year":"2013","unstructured":"Kushimoto S, Gando S, Saitoh D, et al. The impact of body temperature abnormalities on the disease severity and outcome in patients with severe sepsis: an analysis from a multicenter, prospective survey of severe sepsis. Crit Care. 2013;17(6):R271-R71. https:\/\/doi.org\/10.1186\/cc13106.","journal-title":"Crit Care"},{"issue":"12","key":"5484_CR21","doi-asserted-by":"publisher","first-page":"E63","DOI":"10.1093\/nar\/28.12.e63","volume":"28","author":"T Notomi","year":"2000","unstructured":"Notomi T, Okayama H, Masubuchi H, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28(12):E63. https:\/\/doi.org\/10.1093\/nar\/28.12.e63 published Online First: 2000\/06\/28.","journal-title":"Nucleic Acids Res"},{"key":"5484_CR22","doi-asserted-by":"publisher","first-page":"m2066","DOI":"10.1136\/bmj.m2066","volume":"369","author":"E Mahase","year":"2020","unstructured":"Mahase E. Covid-19: two antibody tests are \u201chighly specific\u201d but vary in sensitivity, evaluations find. BMJ. 2020;369:m2066. https:\/\/doi.org\/10.1136\/bmj.m2066.","journal-title":"BMJ"}],"container-title":["BMC Infectious Diseases"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12879-020-05484-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12879-020-05484-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12879-020-05484-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T19:46:03Z","timestamp":1634672763000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcinfectdis.biomedcentral.com\/articles\/10.1186\/s12879-020-05484-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,20]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["5484"],"URL":"https:\/\/doi.org\/10.1186\/s12879-020-05484-8","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2020.04.01.20047357","asserted-by":"object"}]},"ISSN":["1471-2334"],"issn-type":[{"value":"1471-2334","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,20]]},"assertion":[{"value":"11 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This project was a clinical service improvement and the requirement for research ethics committee (REC) approval was therefore waived in line with NHS Health Research Authority guidance (\n                      \n                      ). This decision to waive REC approval had oversight of two institutional review bodies: The office of the Integrated Care Medical Director and Research and Development, Guy\u2019s & St Thomas\u2019 NHS Trust, and the Clinical Academic Group for Medicine and Therapies, King\u2019s Health Partners. In line with procedures relating to a clinical service improvement, all capacitous participants, and relatives in case of non-capacitous participants, were verbally appraised of the project and given the opportunity to not take part. Written appraisal was not practical due to visiting restrictions. This approach was approved by the institutional review bodies.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"CJS is supported by HEFCE funding. CS and SW are employees of MicrosensDX Ltd. Testing was provided free of charge by MicrosensDx. Other authors report no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"783"}}