{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,10]],"date-time":"2026-10-10T02:03:11Z","timestamp":1791597791325,"version":"4.3.4"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,6,3]],"date-time":"2022-06-03T00:00:00Z","timestamp":1654214400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,3]],"date-time":"2022-06-03T00:00:00Z","timestamp":1654214400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Qingdao Health Science and Technology Development Plan project","award":["2020-WJZD133"],"award-info":[{"award-number":["2020-WJZD133"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To compare the effects of deep learning image reconstruction (DLIR) and adaptive statistical iterative reconstruction V (ASiR-V) on image quality in low-dose computed tomography (CT) of paranasal sinuses in children.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Low-dose CT scans of the paranasal sinuses in 25 pediatric patients were retrospectively evaluated. The raw data were reconstructed with three levels of DLIR (high, H; medium, M; and low, L), filtered back projection (FBP), and ASiR-V (30% and 50%). Image noise was measured in both soft tissue and bone windows, and the signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of the images were calculated. Subjective image quality at the ethmoid sinus and nasal cavity levels of the six groups of reconstructed images was assessed by two doctors using a five-point Likert scale in a double-blind manner.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The patients\u2019 mean dose-length product and effective dose were 36.65\u2009\u00b1\u20092.44\u00a0mGy\u00b7cm and 0.17\u2009\u00b1\u20090.03\u00a0mSv, respectively. (1) Objective evaluation: 1. Soft tissue window: The difference among groups in each parameter was significant (P\u2009&lt;\u20090.05). Pairwise comparisons showed that the H group\u2019 s parameters were significantly better (P\u2009&lt;\u20090.05) than those of the 50% post-ASiR-V group. 2. Bone window: No significant between-group differences were found in the noise of the petrous portion of the temporal bone or its SNR or in the noise of the pterygoid processes of the sphenoids or their SNRs (P\u2009&gt;\u20090.05). Significant differences were observed in the background noise and CNR (P\u2009&lt;\u20090.05). As the DLIR intensity increased, image noise decreased and the CNR improved. The H group exhibited the best image quality. (2) Subjective evaluation: Scores for images of the ethmoid sinuses were not significantly different among groups (P\u2009&gt;\u20090.05). Scores for images of the nasal cavity were significantly different among groups (P\u2009&lt;\u20090.05) and were ranked in descending order as follows: H, M, L, 50% post-ASiR-V, 30% post-ASiR-V, and FBP.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>DLIR was superior to FBP and post-ASiR-V in low-dose CT scans of pediatric paranasal sinuses. At high intensity (H), DLIR provided the best reconstruction effects.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12880-022-00834-1","type":"journal-article","created":{"date-parts":[[2022,6,3]],"date-time":"2022-06-03T04:12:53Z","timestamp":1654229573000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Assessment of low-dose paranasal sinus CT imaging using a new deep learning image reconstruction technique in children compared to adaptive statistical iterative reconstruction V (ASiR-V)"],"prefix":"10.1186","volume":"22","author":[{"given":"Yang","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xia","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xun-hui","family":"Zhuang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-jun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiu-feng","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,3]]},"reference":[{"issue":"11","key":"834_CR1","doi-asserted-by":"publisher","first-page":"4155","DOI":"10.1007\/s00330-016-4263-0","volume":"26","author":"W Wuest","year":"2016","unstructured":"Wuest W, May M, Saake M, Brand M, Uder M, Lell M. Low-dose CT of the paranasal sinuses: minimizing X-ray exposure with spectral shaping. Eur Radiol. 2016;26(11):4155\u201361.","journal-title":"Eur Radiol"},{"issue":"3","key":"834_CR2","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1148\/rg.2019180082","volume":"39","author":"RV Gottumukkala","year":"2019","unstructured":"Gottumukkala RV, Kalra MK, Tabari A, Otrakji A, Gee MS. Advanced CT techniques for decreasing radiation dose, reducing sedation requirements, and optimizing image quality in children. Radiographics. 2019;39(3):709\u201326.","journal-title":"Radiographics"},{"issue":"5","key":"834_CR3","doi-asserted-by":"publisher","first-page":"1421","DOI":"10.1148\/rg.2018180041","volume":"38","author":"Y Nagayama","year":"2018","unstructured":"Nagayama Y, Oda S, Nakaura T, Tsuji A, Urata J, Furusawa M, Utsunomiya D, Funama Y, Kidoh M, Yamashita Y. Radiation dose reduction at pediatric CT: use of low tube voltage and iterative reconstruction. Radiographics. 2018;38(5):1421\u201340.","journal-title":"Radiographics"},{"issue":"5","key":"834_CR4","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.3174\/ajnr.A3339","volume":"34","author":"B Schulz","year":"2013","unstructured":"Schulz B, Beeres M, Bodelle B, Bauer R, Al-Butmeh F, Thalhammer A, Vogl TJ, Kerl JM. Performance of iterative image reconstruction in CT of the paranasal sinuses: a phantom study. Am J Neuroradiol. 2013;34(5):1072\u20136.","journal-title":"Am J Neuroradiol"},{"issue":"3","key":"834_CR5","doi-asserted-by":"publisher","first-page":"713","DOI":"10.2214\/AJR.09.2989","volume":"195","author":"Y Sagara","year":"2010","unstructured":"Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q. Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. Am J Roentgenol. 2010;195(3):713\u20139.","journal-title":"Am J Roentgenol"},{"issue":"1","key":"834_CR6","doi-asserted-by":"publisher","first-page":"84","DOI":"10.2214\/AJR.17.19441","volume":"212","author":"T F\u00e4lt","year":"2019","unstructured":"F\u00e4lt T, S\u00f6derberg M, H\u00f6rberg L, et al. Simulated dose reduction for abdominal CT with filtered back projection technique: effect on liver lesion detection and characterization. Am J Roentgenol. 2019;212(1):84\u201393.","journal-title":"Am J Roentgenol"},{"issue":"2","key":"834_CR7","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1002\/acm2.12253","volume":"19","author":"P De Marco","year":"2018","unstructured":"De Marco P, Origgi D. New adaptive statistical iterative reconstruction ASiR-V: assessment of noise performance in comparison to ASiR. J Appl Clin Med Phys. 2018;19(2):275\u201386.","journal-title":"J Appl Clin Med Phys"},{"issue":"1103","key":"834_CR8","doi-asserted-by":"publisher","first-page":"20180909","DOI":"10.1259\/bjr.20180909","volume":"92","author":"H Tang","year":"2019","unstructured":"Tang H, Liu Z, Hu Z, et al. Clinical value of a new generation adaptive statistical iterative reconstruction (ASIR-V) in the diagnosis of pulmonary nodule in low-dose chest CT. Br J Radiol. 2019;92(1103):20180909.","journal-title":"Br J Radiol"},{"issue":"3","key":"834_CR9","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1148\/radiol.2019191422","volume":"293","author":"A Mileto","year":"2019","unstructured":"Mileto A, Guimaraes LS, McCollough CH, Fletcher JG, Yu L. State of the art in abdominal CT: the limits of iterative reconstruction algorithms. Radiology. 2019;293(3):491\u2013503.","journal-title":"Radiology"},{"issue":"1","key":"834_CR10","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1148\/radiol.10100047","volume":"257","author":"PD Deak","year":"2010","unstructured":"Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology. 2010;257(1):158\u201366.","journal-title":"Radiology"},{"issue":"10","key":"834_CR11","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1080\/09553002.2017.1304669","volume":"93","author":"LT Dauer","year":"2017","unstructured":"Dauer LT, Ainsbury EA, Dynlacht J, Hoel D, Klein BEK, Mayer D, et al. Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP Commentary No. 26. Int J Radiat Biol. 2017;93(10):1015\u201323.","journal-title":"Int J Radiat Biol"},{"issue":"7","key":"834_CR12","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1016\/j.crad.2015.03.002","volume":"70","author":"B Bodelle","year":"2015","unstructured":"Bodelle B, Wichmann JL, Klotz N, Lehnert T, Vogl TJ, Luboldt W, Schulz B. Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical results. Clin Radiol. 2015;70(7):711\u20135.","journal-title":"Clin Radiol"},{"key":"834_CR13","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/s00234-016-1780-0","volume":"59","author":"MS May","year":"2017","unstructured":"May MS, Brand M, Lell MM, Sedlmair M, Allmendinger T, Uder M, et al. Radiation dose reduction in parasinus CT by spectral shaping. Neuroradiology. 2017;59:169\u201376.","journal-title":"Neuroradiology"},{"issue":"5","key":"834_CR14","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0216295","volume":"14","author":"B Petritsch","year":"2019","unstructured":"Petritsch B, Kosmala A, Weng AM, Bley TA. Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results. PLoS ONE. 2019;14(5): e0216295.","journal-title":"PLoS ONE"},{"issue":"8","key":"834_CR15","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1016\/j.acra.2009.02.021","volume":"16","author":"ST Schindera","year":"2009","unstructured":"Schindera ST, Nelson RC, Yoshizumi T, et al. Effect of automatic tube current modulation on radiation dose and image quality for low tube voltage multidetector row CT angiography: phantom study. Acad Radiol. 2009;16(8):997\u20131002.","journal-title":"Acad Radiol"},{"issue":"Suppl 1","key":"834_CR16","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s10554-011-9960-9","volume":"27","author":"JF Paul","year":"2011","unstructured":"Paul JF. Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality. Int J Cardiovasc Imaging. 2011;27(Suppl 1):53\u20139.","journal-title":"Int J Cardiovasc Imaging"},{"issue":"4","key":"834_CR17","doi-asserted-by":"publisher","first-page":"731","DOI":"10.3233\/XST-180487","volume":"27","author":"Q Kong","year":"2019","unstructured":"Kong Q, Lu F, Gao Y, Qiao P, Shao M, Xie M. Wide-detector CT combined iterative reconstruction in pediatric low-dose scan of the paranasal sinus. J X-ray Sci Technol. 2019;27(4):731\u20138.","journal-title":"J X-ray Sci Technol"},{"issue":"2","key":"834_CR18","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s11547-017-0812-0","volume":"123","author":"J Sun","year":"2018","unstructured":"Sun J, Zhang Q, Duan X, Zhang C, Wang P, Jia C, Liu Y, Peng Y. Application of a full model-based iterative reconstruction (MBIR) in 80\u00a0kVp ultra-low-dose paranasal sinus CT imaging of pediatric patients. Radiol Med. 2018;123(2):117\u201324.","journal-title":"Radiol Med"},{"key":"834_CR19","doi-asserted-by":"crossref","unstructured":"Kwon H, Cho J, Oh J, et al. The adaptive statistical iterative reconstruction-V technique for radiation dose reduction in abdominal CT: comparison with the adaptive statistical iterative reconstruction technique. Br J Radiol. 2016;89(1058):20150463e. Br J Radiol. 2015;88(1054):20150463.","DOI":"10.1259\/bjr.20150463"},{"issue":"1","key":"834_CR20","doi-asserted-by":"publisher","first-page":"50","DOI":"10.2214\/AJR.19.22332","volume":"215","author":"CT Jensen","year":"2020","unstructured":"Jensen CT, Liu X, Tamm EP, et al. Image quality assessment of abdominal CT by use of new deep learning image reconstruction: initial experience. Am J Roentgenol. 2020;215(1):50\u20137.","journal-title":"Am J Roentgenol"},{"issue":"1","key":"834_CR21","doi-asserted-by":"publisher","first-page":"131","DOI":"10.3348\/kjr.2020.0116","volume":"22","author":"JH Kim","year":"2021","unstructured":"Kim JH, Yoon HJ, Lee E, Kim I, Cha YK, Bak SH. Validation of deep-learning image reconstruction for low-dose chest computed tomography scan: emphasis on image quality and noise. Korean J Radiol. 2021;22(1):131\u20138.","journal-title":"Korean J Radiol"},{"issue":"2","key":"834_CR22","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.oooo.2020.11.018","volume":"132","author":"R Rozema","year":"2021","unstructured":"Rozema R, Kruitbosch HT, van Minnen B, Dorgelo B, Kraeima J, van Ooijen PMA. Iterative reconstruction and deep learning algorithms for enabling low-dose computed tomography in midfacial trauma. Oral Surg Oral Med Oral Pathol Oral Radiol. 2021;132(2):247\u201354.","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-022-00834-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-022-00834-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-022-00834-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,3]],"date-time":"2022-06-03T04:14:48Z","timestamp":1654229688000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmedimaging.biomedcentral.com\/articles\/10.1186\/s12880-022-00834-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,3]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["834"],"URL":"https:\/\/doi.org\/10.1186\/s12880-022-00834-1","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,3]]},"assertion":[{"value":"21 December 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted in accordance with the principles of the Declaration of Helsinki. This retrospective study was approved by the Ethics Committees of Qingdao university affiliated Women and Children\u2019s Hospital for using the data, and the informed consent was waved. The research protocol was in compliance with relevant Chinese laws.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The author of this manuscript declares relationship with the following companies: GE Healthcare (MW). Authors with no financial ties to GE Healthcare (YL, XL, XZ, and XS).","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"106"}}