{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T16:55:01Z","timestamp":1781628901175,"version":"3.54.5"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,2]],"date-time":"2026-01-02T00:00:00Z","timestamp":1767312000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T00:00:00Z","timestamp":1769472000000},"content-version":"vor","delay-in-days":25,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100012940","name":"Universit\u00e4tsklinikum T\u00fcbingen","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100012940","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Med Imaging"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Noise and artifacts often compromise image quality and diagnostic accuracy in liver Volume Perfusion CT (VPCT), which can impact clinical decision-making in the diagnosis of hepatocellular carcinoma (HCC). AI-based denoising can potentially improve image quality in computed tomography imaging. Therefore, we aimed to evaluate the effects of AI denoising (AID) on image quality and Milan classification in VPCT compared to standard methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>VPCT examinations from 100 patients acquired between 2017 and 2021 were retrospectively included in the analysis. Perfusion maps were reconstructed using original data (Origin), vendor-specific median filtration (Vendor), and AID. Two radiologists independently scored subjective image quality (image quality, diagnostic confidence, contrast, and sharpness). Objective image quality parameters (CT numbers, noise, contrast-to-noise ratios) and diameters of all HCC lesions were measured across all datasets. Additionally, the Milan classification was determined for each patient.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      AID enhanced subjective image quality (0.48\u2009\u00b1\u20090.29) compared to Origin (-0.31\u2009\u00b1\u20090.29, p-value\u2009&lt;\u20090.001) and Vendor (-0.17\u2009\u00b1\u20090.24, p-value\u2009&lt;\u20090.001). CNR was higher in AID (27.40\u2009\u00b1\u20092.98) compared to Origin (16.98\u2009\u00b1\u20091.54,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001) and Vendor (19.43\u2009\u00b1\u20091.79,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). No significant differences were found regarding lesion diameter between Origin, Vendor, and AID (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&gt;\u20090.999). The number and localization of HCC lesions were equal between Origin, Vendor, and AID. The different reconstruction methods did not affect Milan classification.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>AID enhances the image quality of HCC liver VPCT without compromising diagnostic capabilities and may support the evaluation of VPCT in the diagnosis of HCC.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12880-025-02138-6","type":"journal-article","created":{"date-parts":[[2026,1,3]],"date-time":"2026-01-03T06:21:34Z","timestamp":1767421294000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["AI-based denoising improves image quality in HCC volume perfusion CT without affecting Milan classification"],"prefix":"10.1186","volume":"26","author":[{"given":"Patrick","family":"Ghibes","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reza","family":"Dehdab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Michael","family":"Brendel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saif","family":"Afat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arne","family":"Estler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christoph","family":"Artzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantin","family":"Nikolaou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"Brendlin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,2]]},"reference":[{"issue":"2","key":"2138_CR1","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.cgh.2021.05.002","volume":"20","author":"LA Orci","year":"2022","unstructured":"Orci LA, Sanduzzi-Zamparelli M, Caballol B, Sapena V, Colucci N, Torres F, et al. Incidence of hepatocellular carcinoma in patients with nonalcoholic fatty liver disease: A systematic Review, Meta-analysis, and Meta-regression. Clin Gastroenterol Hepatology: Official Clin Pract J Am Gastroenterological Association. 2022;20(2):283\u2013e9210.","journal-title":"Clin Gastroenterol Hepatology: Official Clin Pract J Am Gastroenterological Association"},{"issue":"10127","key":"2138_CR2","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1016\/S0140-6736(18)30010-2","volume":"391","author":"A Forner","year":"2018","unstructured":"Forner A, Reig M, Bruix J. Hepatocellular carcinoma. Lancet (London England). 2018;391(10127):1301\u201314.","journal-title":"Lancet (London England)"},{"key":"2138_CR3","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.ejrad.2018.01.025","volume":"101","author":"C Ayuso","year":"2018","unstructured":"Ayuso C, Rimola J, Vilana R, Burrel M, Darnell A, Garc\u00eda-Criado \u00c1, et al. Diagnosis and staging of hepatocellular carcinoma (HCC): current guidelines. Eur J Radiol. 2018;101:72\u201381.","journal-title":"Eur J Radiol"},{"issue":"2","key":"2138_CR4","doi-asserted-by":"publisher","first-page":"723","DOI":"10.1002\/hep.29913","volume":"68","author":"JA Marrero","year":"2018","unstructured":"Marrero JA, Kulik LM, Sirlin CB, Zhu AX, Finn RS, Abecassis MM, et al. Diagnosis, Staging, and management of hepatocellular carcinoma: 2018 practice guidance by the American association for the study of liver diseases. Hepatology (Baltimore MD). 2018;68(2):723\u201350.","journal-title":"Hepatology (Baltimore MD)"},{"issue":"1","key":"2138_CR5","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1102\/1470-7330.2010.0001","volume":"10","author":"G Petralia","year":"2010","unstructured":"Petralia G, Bonello L, Viotti S, Preda L, D\u2019Andrea G, Bellomi M. CT perfusion in oncology: how to do it. Cancer Imaging: Official Publication Int Cancer Imaging Soc. 2010;10(1):8\u201319.","journal-title":"Cancer Imaging: Official Publication Int Cancer Imaging Soc"},{"issue":"7","key":"2138_CR6","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.1016\/j.ejrad.2011.04.010","volume":"81","author":"D Spira","year":"2012","unstructured":"Spira D, Schulze M, Sauter A, Brodoefel H, Brechtel K, Claussen C, et al. Volume perfusion-CT of the liver: insights and applications. Eur J Radiol. 2012;81(7):1471\u20138.","journal-title":"Eur J Radiol"},{"issue":"3","key":"2138_CR7","doi-asserted-by":"publisher","first-page":"1410","DOI":"10.1007\/s00330-020-07206-9","volume":"31","author":"G Kalarakis","year":"2021","unstructured":"Kalarakis G, Perisinakis K, Akoumianakis E, Karageorgiou I, Hatzidakis A. CT liver perfusion in patients with hepatocellular carcinoma: can we modify acquisition protocol to reduce patient exposure? Eur Radiol. 2021;31(3):1410\u20139.","journal-title":"Eur Radiol"},{"issue":"12","key":"2138_CR8","doi-asserted-by":"publisher","first-page":"6550","DOI":"10.1007\/s00330-019-06259-9","volume":"29","author":"A Bevilacqua","year":"2019","unstructured":"Bevilacqua A, Malavasi S, Vilgrain V. Liver CT perfusion: which is the relevant delay that reduces radiation dose and maintains diagnostic accuracy? Eur Radiol. 2019;29(12):6550\u20138.","journal-title":"Eur Radiol"},{"issue":"7","key":"2138_CR9","doi-asserted-by":"publisher","first-page":"3951","DOI":"10.1007\/s00330-020-06724-w","volume":"30","author":"J Greffier","year":"2020","unstructured":"Greffier J, Hamard A, Pereira F, Barrau C, Pasquier H, Beregi JP, et al. Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a Phantom study. Eur Radiol. 2020;30(7):3951\u20139.","journal-title":"Eur Radiol"},{"issue":"3","key":"2138_CR10","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1148\/radiol.2019191422","volume":"293","author":"A Mileto","year":"2019","unstructured":"Mileto A, Guimaraes LS, McCollough CH, Fletcher JG, Yu L. State of the Art in abdominal CT: the limits of iterative reconstruction algorithms. Radiology. 2019;293(3):491\u2013503.","journal-title":"Radiology"},{"issue":"8","key":"2138_CR11","doi-asserted-by":"publisher","first-page":"4016","DOI":"10.1007\/s00330-018-5988-8","volume":"29","author":"G Laurent","year":"2019","unstructured":"Laurent G, Villani N, Hossu G, Rauch A, Noel A, Blum A, et al. Full model-based iterative reconstruction (MBIR) in abdominal CT increases objective image quality, but decreases subjective acceptance. Eur Radiol. 2019;29(8):4016\u201325.","journal-title":"Eur Radiol"},{"issue":"2","key":"2138_CR12","doi-asserted-by":"publisher","first-page":"e230153","DOI":"10.1148\/ryai.230153","volume":"6","author":"V Sandfort","year":"2024","unstructured":"Sandfort V, Willemink MJ, Codari M, Mastrodicasa D, Fleischmann D. Denoising multiphase functional cardiac CT angiography using deep learning and synthetic data. Radiol Artif Intell. 2024;6(2):e230153.","journal-title":"Radiol Artif Intell"},{"issue":"4","key":"2138_CR13","doi-asserted-by":"publisher","first-page":"1578","DOI":"10.1007\/s10278-023-00808-x","volume":"36","author":"M Nagata","year":"2023","unstructured":"Nagata M, Ichikawa Y, Domae K, Yoshikawa K, Kanii Y, Yamazaki A, et al. Application of deep Learning-Based denoising technique for radiation dose reduction in dynamic abdominal CT: comparison with Standard-Dose CT using hybrid iterative reconstruction method. J Digit Imaging. 2023;36(4):1578\u201387.","journal-title":"J Digit Imaging"},{"issue":"2","key":"2138_CR14","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1097\/RCT.0000000000001665","volume":"49","author":"M Park","year":"2025","unstructured":"Park M, Hwang M, Lee JW, Kim KI, Ahn C, Suh YJ, et al. Application of a deep Learning-Based Contrast-Boosting algorithm to Low-Dose computed tomography pulmonary angiography with reduced iodine load. J Comput Assist Tomogr. 2025;49(2):288\u201396.","journal-title":"J Comput Assist Tomogr"},{"key":"2138_CR15","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.bspc.2018.01.010","volume":"42","author":"M Diwakar","year":"2018","unstructured":"Diwakar M, Kumar M. A review on CT image noise and its denoising. Biomed Signal Process Control. 2018;42:73\u201388.","journal-title":"Biomed Signal Process Control"},{"issue":"5","key":"2138_CR16","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.1148\/rg.2021200196","volume":"41","author":"P Mohammadinejad","year":"2021","unstructured":"Mohammadinejad P, Mileto A, Yu L, Leng S, Guimaraes LS, Missert AD, et al. CT noise-reduction methods for lower-dose scanning: strengths and weaknesses of iterative reconstruction algorithms and new techniques. Radiographics. 2021;41(5):1493\u2013508.","journal-title":"Radiographics"},{"issue":"8","key":"2138_CR17","doi-asserted-by":"publisher","first-page":"7006","DOI":"10.21037\/qims-2025-365","volume":"15","author":"P Hou","year":"2025","unstructured":"Hou P, Feng X, Chen Y, Wang X, Jiang Y, Liu J, et al. Ultra-low-dose hepatic computed tomography with a novel real-time deep learning-based noise reduction algorithm: a prospective cross-sectional analysis of image quality and lesion detection. Quant Imaging Med Surg. 2025;15(8):7006\u201318.","journal-title":"Quant Imaging Med Surg"},{"issue":"6","key":"2138_CR18","doi-asserted-by":"publisher","first-page":"4344","DOI":"10.1007\/s00330-022-09298-x","volume":"33","author":"JS Bae","year":"2023","unstructured":"Bae JS, Lee JM, Kim SW, Park S, Han S, Yoon JH, et al. Low-contrast-dose liver CT using low monoenergetic images with deep learning-based denoising for assessing hepatocellular carcinoma: a randomized controlled noninferiority trial. Eur Radiol. 2023;33(6):4344\u201354.","journal-title":"Eur Radiol"},{"issue":"5","key":"2138_CR19","doi-asserted-by":"publisher","first-page":"2865","DOI":"10.1007\/s00330-021-08380-0","volume":"32","author":"S Park","year":"2022","unstructured":"Park S, Yoon JH, Joo I, Yu MH, Kim JH, Park J, et al. Image quality in liver CT: low-dose deep learning vs standard-dose model-based iterative reconstructions. Eur Radiol. 2022;32(5):2865\u201374.","journal-title":"Eur Radiol"},{"issue":"1","key":"2138_CR20","doi-asserted-by":"publisher","first-page":"73","DOI":"10.2214\/AJR.22.27806","volume":"220","author":"A Inoue","year":"2023","unstructured":"Inoue A, Voss BA, Lee NJ, Takahashi H, Kozaka K, Heiken JP, et al. Diagnostic performance in Low- and High-Contrast tasks of an Image-Based denoising algorithm applied to radiation Dose-Reduced multiphase abdominal CT examinations. AJR Am J Roentgenol. 2023;220(1):73\u201385.","journal-title":"AJR Am J Roentgenol"},{"issue":"10","key":"2138_CR21","doi-asserted-by":"publisher","first-page":"1903","DOI":"10.1007\/s11548-023-02862-w","volume":"18","author":"G Azarfar","year":"2023","unstructured":"Azarfar G, Ko SB, Adams SJ, Babyn PS. Applications of deep learning to reduce the need for iodinated contrast media for CT imaging: a systematic review. Int J Comput Assist Radiol Surg. 2023;18(10):1903\u201314.","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"10","key":"2138_CR22","doi-asserted-by":"publisher","first-page":"1468","DOI":"10.3174\/ajnr.A8367","volume":"45","author":"M Mossa-Basha","year":"2024","unstructured":"Mossa-Basha M, Zhu C, Pandhi T, Mendoza S, Azadbakht J, Safwat A, et al. Deep learning denoising improves CT perfusion image quality in the setting of lower contrast dosing: A feasibility study. AJNR Am J Neuroradiol. 2024;45(10):1468\u201374.","journal-title":"AJNR Am J Neuroradiol"},{"key":"2138_CR23","doi-asserted-by":"publisher","first-page":"1415859","DOI":"10.3389\/fonc.2024.1415859","volume":"14","author":"L Wang","year":"2024","unstructured":"Wang L, Fatemi M, Alizad A. Artificial intelligence techniques in liver cancer. Front Oncol. 2024;14:1415859.","journal-title":"Front Oncol"},{"issue":"9","key":"2138_CR24","first-page":"779","volume":"157","author":"P Tabrizian","year":"2022","unstructured":"Tabrizian P, Holzner ML, Mehta N, Halazun K, Agopian VG, Yao F, et al. Ten-Year outcomes of liver transplant and downstaging for hepatocellular carcinoma. JAMA Surg. 2022;157(9):779\u201388.","journal-title":"JAMA Surg"},{"issue":"4","key":"2138_CR25","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","volume":"41","author":"F Faul","year":"2009","unstructured":"Faul F, Erdfelder E, Buchner A, Lang AG. Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149\u201360.","journal-title":"Behav Res Methods"},{"issue":"3\u20134","key":"2138_CR26","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1093\/rpd\/ncab014","volume":"195","author":"A Svalkvist","year":"2021","unstructured":"Svalkvist A, Svensson S, Hagberg T, B\u00e5th M. Viewdex 3.0\u2014recent development of a software application facilitating assessment of image quality and observer performance. Radiat Prot Dosimetry. 2021;195(3\u20134):372\u20137.","journal-title":"Radiat Prot Dosimetry"},{"issue":"7","key":"2138_CR27","doi-asserted-by":"publisher","first-page":"4494","DOI":"10.1007\/s00330-023-10493-7","volume":"34","author":"EJI Hoeijmakers","year":"2024","unstructured":"Hoeijmakers EJI, Martens B, Hendriks BMF, Mihl C, Miclea RL, Backes WH, et al. How subjective CT image quality assessment becomes surprisingly reliable: pairwise comparisons instead of likert scale. Eur Radiol. 2024;34(7):4494\u2013503.","journal-title":"Eur Radiol"},{"issue":"10","key":"2138_CR28","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.3348\/kjr.2020.0020","volume":"21","author":"JH Hong","year":"2020","unstructured":"Hong JH, Park EA, Lee W, Ahn C, Kim JH. Incremental image noise reduction in coronary CT angiography using a deep Learning-Based technique with iterative reconstruction. Korean J Radiol. 2020;21(10):1165\u201377.","journal-title":"Korean J Radiol"},{"issue":"7","key":"2138_CR29","doi-asserted-by":"publisher","first-page":"5139","DOI":"10.1007\/s00330-020-07537-7","volume":"31","author":"JG Nam","year":"2021","unstructured":"Nam JG, Ahn C, Choi H, Hong W, Park J, Kim JH, et al. Image quality of ultralow-dose chest CT using deep learning techniques: potential superiority of vendor-agnostic post-processing over vendor-specific techniques. Eur Radiol. 2021;31(7):5139\u201347.","journal-title":"Eur Radiol"},{"issue":"4","key":"2138_CR30","doi-asserted-by":"publisher","first-page":"2218","DOI":"10.1007\/s00330-020-07349-9","volume":"31","author":"S Lee","year":"2021","unstructured":"Lee S, Choi YH, Cho YJ, Lee SB, Cheon J-E, Kim WS, et al. Noise reduction approach in pediatric abdominal CT combining deep learning and dual-energy technique. Eur Radiol. 2021;31(4):2218\u201326.","journal-title":"Eur Radiol"},{"issue":"11","key":"2138_CR31","doi-asserted-by":"publisher","first-page":"2588","DOI":"10.1016\/j.acra.2023.02.019","volume":"30","author":"L Gorenstein","year":"2023","unstructured":"Gorenstein L, Onn A, Green M, Mayer A, Segev S, Marom EM. A novel artificial intelligence based denoising method for Ultra-Low dose CT used for lung cancer screening. Acad Radiol. 2023;30(11):2588\u201397.","journal-title":"Acad Radiol"},{"issue":"11","key":"2138_CR32","doi-asserted-by":"publisher","first-page":"6163","DOI":"10.1007\/s00330-019-06170-3","volume":"29","author":"M Akagi","year":"2019","unstructured":"Akagi M, Nakamura Y, Higaki T, Narita K, Honda Y, Zhou J, et al. Deep learning reconstruction improves image quality of abdominal ultra-high-resolution CT. Eur Radiol. 2019;29(11):6163\u201371.","journal-title":"Eur Radiol"},{"issue":"6","key":"2138_CR33","doi-asserted-by":"publisher","first-page":"e180011","DOI":"10.1148\/ryai.2019180011","volume":"1","author":"Y Nakamura","year":"2019","unstructured":"Nakamura Y, Higaki T, Tatsugami F, Zhou J, Yu Z, Akino N, et al. Deep Learning-based CT image reconstruction: initial evaluation targeting hypovascular hepatic metastases. Radiol Artif Intell. 2019;1(6):e180011.","journal-title":"Radiol Artif Intell"},{"issue":"11","key":"2138_CR34","doi-asserted-by":"publisher","first-page":"3496","DOI":"10.1007\/s00261-019-02338-z","volume":"45","author":"M Ronot","year":"2020","unstructured":"Ronot M, Leporq B, van Beers BE, Vilgrain V. CT and MR perfusion techniques to assess diffuse liver disease. Abdom Radiol (New York). 2020;45(11):3496\u2013506.","journal-title":"Abdom Radiol (New York)"},{"issue":"6","key":"2138_CR35","doi-asserted-by":"publisher","first-page":"495","DOI":"10.5152\/dir.2016.16612","volume":"22","author":"OM Topcuo\u011flu","year":"2016","unstructured":"Topcuo\u011flu OM, Kar\u00e7aalt\u0131ncaba M, Akata D, \u00d6zmen MN. Reproducibility and variability of very low dose hepatic perfusion CT in metastatic liver disease. Diagn Interv Radiol (Ankara Turkey). 2016;22(6):495\u2013500.","journal-title":"Diagn Interv Radiol (Ankara Turkey)"},{"issue":"1","key":"2138_CR36","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1148\/radiol.14140141","volume":"274","author":"DH Lee","year":"2015","unstructured":"Lee DH, Lee JM, Baek JH, Shin CI, Han JK, Choi BI. Diagnostic performance of Gadoxetic acid-enhanced liver MR imaging in the detection of HCCs and allocation of transplant recipients on the basis of the Milan criteria and UNOS guidelines: correlation with histopathologic findings. Radiology. 2015;274(1):149\u201360.","journal-title":"Radiology"},{"issue":"4","key":"2138_CR37","doi-asserted-by":"publisher","first-page":"726","DOI":"10.2214\/AJR.15.14642","volume":"206","author":"N Rostambeigi","year":"2016","unstructured":"Rostambeigi N, Taylor AJ, Golzarian J, Jensen EH, Pruett TL, Dudeja V, et al. Effect of MRI versus MDCT on Milan criteria scores and liver transplantation eligibility. AJR Am J Roentgenol. 2016;206(4):726\u201333.","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"2138_CR38","doi-asserted-by":"publisher","first-page":"1029","DOI":"10.1016\/j.ejrad.2015.02.020","volume":"84","author":"S Kaufmann","year":"2015","unstructured":"Kaufmann S, Horger T, Oelker A, Kloth C, Nikolaou K, Schulze M, et al. Characterization of hepatocellular carcinoma (HCC) lesions using a novel CT-based volume perfusion (VPCT) technique. Eur J Radiol. 2015;84(6):1029\u201335.","journal-title":"Eur J Radiol"},{"issue":"1","key":"2138_CR39","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40644-017-0121-9","volume":"17","author":"M Kurucay","year":"2017","unstructured":"Kurucay M, Kloth C, Kaufmann S, Nikolaou K, Bosmuller H, Horger M, et al. Multiparametric imaging for detection and characterization of hepatocellular carcinoma using Gadoxetic acid-enhanced MRI and perfusion-CT: which parameters work best? Cancer Imaging. 2017;17(1):18.","journal-title":"Cancer Imaging"},{"issue":"11","key":"2138_CR40","doi-asserted-by":"publisher","first-page":"3123","DOI":"10.1007\/s00330-015-3732-1","volume":"25","author":"MA Fischer","year":"2015","unstructured":"Fischer MA, Kartalis N, Grigoriadis A, Loizou L, Stal P, Leidner B, et al. Perfusion computed tomography for detection of hepatocellular carcinoma in patients with liver cirrhosis. Eur Radiol. 2015;25(11):3123\u201332.","journal-title":"Eur Radiol"},{"issue":"1","key":"2138_CR41","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1148\/radiol.2015151560","volume":"280","author":"S Gordic","year":"2016","unstructured":"Gordic S, Puippe GD, Krauss B, Klotz E, Desbiolles L, Lesurtel M, et al. Correlation between Dual-Energy and perfusion CT in patients with hepatocellular carcinoma. Radiology. 2016;280(1):78\u201387.","journal-title":"Radiology"},{"issue":"2","key":"2138_CR42","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1007\/s00330-021-08199-9","volume":"32","author":"H Choi","year":"2022","unstructured":"Choi H, Chang W, Kim JH, Ahn C, Lee H, Kim HY, et al. Dose reduction potential of vendor-agnostic deep learning model in comparison with deep learning-based image reconstruction algorithm on CT: a Phantom study. Eur Radiol. 2022;32(2):1247\u201355.","journal-title":"Eur Radiol"},{"issue":"6","key":"2138_CR43","doi-asserted-by":"publisher","first-page":"3519","DOI":"10.1016\/j.acra.2024.12.052","volume":"32","author":"R Dehdab","year":"2025","unstructured":"Dehdab R, Brendel JM, Streich S, Ladurner R, Stenzl B, Mueck J, et al. Evaluation of a deep learning denoising algorithm for dose reduction in Whole-Body Photon-Counting CT imaging: A cadaveric study. Acad Radiol. 2025;32(6):3519\u201331.","journal-title":"Acad Radiol"}],"container-title":["BMC Medical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12880-025-02138-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-02138-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12880-025-02138-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T16:02:17Z","timestamp":1781625737000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12880-025-02138-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,2]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2138"],"URL":"https:\/\/doi.org\/10.1186\/s12880-025-02138-6","relation":{},"ISSN":["1471-2342"],"issn-type":[{"value":"1471-2342","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,2]]},"assertion":[{"value":"5 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This monocentric retrospective study was approved by the institutional review board of the university of Tuebingen (study #167\/2022BO2) with a waiver for the need for informed consent in accordance with the ethical standards outlined in the Declaration of Helsinki, as revised in 2013.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"53"}}