{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T05:14:32Z","timestamp":1793942072382,"version":"4.8.0"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,10,28]],"date-time":"2019-10-28T00:00:00Z","timestamp":1572220800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,10,28]],"date-time":"2019-10-28T00:00:00Z","timestamp":1572220800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Nephrol"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n              <jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Online hemodiafiltration (OL-HDF) is associated with better removal of both small and middle molecules and might improve survival compared to conventional hemodialysis (HD). Nevertheless, hemodiafiltration (HDF) can lead to an increase in albumin loss across the dialyzer, especially with high permeability membrane and high convective volume (CV). We present the case of a patient treated by OL-HDF who developed severe hypoalbuminemia resulting from massive albumin loss into dialysate.<\/jats:p>\n              <\/jats:sec>\n              <jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 71-year-old woman with ESRD started renal replacement therapy in December 2016. She was treated by high volume post-dilution OL-HDF, 4\u2009h, 3 times per week. The dialyzer was the Phylther HF20SD (a 2.0m<jats:sup>2<\/jats:sup> heat sterilized high flux\u00a0(HF) polyphenylene membrane from Bellco). At the initiation of dialysis, the serum albumin was 4.0\u2009g\/dl. During the following months, the patient developed severe hypoalbuminemia. The lowest value observed was 2.26 g\/dl in July 2017. Diagnostic workup excluded nephrotic syndrome, hepatic failure and malabsorption. The patient was shifted from OL-HDF to standard HF\u00a0HD, keeping the same dialyzer and dialysis schedule. During the following months, we observed a progressive correction of the hypoalbuminemia (3.82\u2009g\/dl at last follow-up). To precise the impact of the epuration technique on the albumin losses in this patient, we measured the amount of albumin in dialysate during one session with the Phylther HF20SD on OL-HDF and one session with the same filter but on standard HD. The CV was 29.0\u2009l for the HDF session. The total albumin losses were 23.6\u2009g on OL-HDF and 4.6\u2009g on HD.<\/jats:p>\n              <\/jats:sec>\n              <jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>OL-HDF can lead to significant albumin loss into the dialysate, especially with high permeability membrane and high CV. When prescribing post-dilutional OL-HDF, the choice of the dialyzer membrane should be made with caution. Users of the steam sterilized polyphenylene membrane, the Phylther SD, should be informed of the risk of large albumin loss with this membrane during post-dilution OL-HDF.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12882-019-1567-8","type":"journal-article","created":{"date-parts":[[2019,10,28]],"date-time":"2019-10-28T17:05:08Z","timestamp":1572282308000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Albumin losses during hemodiafiltration: all dialyzers are not created equal - a case report"],"prefix":"10.1186","volume":"20","author":[{"given":"Charles","family":"Cuvelier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michel","family":"Tintillier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabriela","family":"Migali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charlotte","family":"Van Ende","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Michel","family":"Pochet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,10,28]]},"reference":[{"key":"1567_CR1","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1093\/ndt\/gfs530","volume":"28","author":"JE Tattersall","year":"2013","unstructured":"Tattersall JE, Ward RA, EUDIAL group. Online haemodiafiltration: definition, dose quantification and safety revisited. Nephrol Dial Transplant. 2013;28:542\u201350. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfs530\n                    \n                  .","journal-title":"Nephrol Dial Transplant"},{"key":"1567_CR2","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1681\/ASN.2011121140","volume":"23","author":"MP Grooteman","year":"2012","unstructured":"Grooteman MP, van den Dorpel MA. Bots ML; penne ML, van der Weerd NC, Mazairac AH effect of online hemodiafiltration on all-cause mortality and cardiovascular outcomes. J Am Soc Nephrol. 2012;23:1087\u201396. \n                    https:\/\/doi.org\/10.1681\/ASN.2011121140\n                    \n                  .","journal-title":"J Am Soc Nephrol"},{"key":"1567_CR3","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1093\/ndt\/gfs407","volume":"28","author":"E Ok","year":"2013","unstructured":"Ok E, Asci G, Toz H, Ok ES, Kircelli F, Hur E, et al. Mortality and cardiovascular events in online haemodiafiltration (OL-HDF) compared with high-flux dialysis: results from the Turkish OL-HDF study. Nephrol Dial Transplant. 2013;28:192\u2013202. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfs407\n                    \n                  .","journal-title":"Nephrol Dial Transplant"},{"key":"1567_CR4","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1681\/ASN.2012080875","volume":"24","author":"F Maduell","year":"2013","unstructured":"Maduell F, Moreso F, Pons M, Ramos R, Mora-Marcia J, Carreras J, et al. High-efficiency postdilution online hemodiafiltration reduces all-cause mortality in hemodialysis patients. J Am Soc Nephrol. 2013;24:487\u201397. \n                    https:\/\/doi.org\/10.1681\/ASN.2012080875\n                    \n                  .","journal-title":"J Am Soc Nephrol"},{"issue":"1","key":"1567_CR5","doi-asserted-by":"publisher","first-page":"21","DOI":"10.5414\/CNP62021","volume":"62","author":"PG Ahrenholz","year":"2004","unstructured":"Ahrenholz PG, Winkler RE, Michelsen A, Lang DA, Bowry SK. Dialysis membrane-dependent removal of middle molecules during hemodiafiltration: the beta2-microglobulin\/albumin relationship. Clin Nephrol. 2004;62(1):21\u20138.","journal-title":"Clin Nephrol"},{"issue":"3","key":"1567_CR6","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1111\/1744-9987.12247","volume":"19","author":"A Vega","year":"2015","unstructured":"Vega A, Quiroga B, Abad S, Aragoncillo I, Arroyo D, Panizo N, et al. Albumin leakage in online hemodiafiltration, more convective transport, more loss? Ther Apher Dial. 2015 Jun;19(3):267\u201371. \n                    https:\/\/doi.org\/10.1111\/1744-9987.12247\n                    \n                  .","journal-title":"Ther Apher Dial"},{"key":"1567_CR7","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1093\/ndt\/gfx277","volume":"33","author":"F Locatelli","year":"2018","unstructured":"Locatelli F, Karaboyas A, Pisoni RL, Robinson BM, Fort J, Vanholder R, et al. Mortality risk in patients on hemodiafiltration versus hemodialysis: a \u2018real-world\u2019 comparison from the DOPPS. Nephrol Dial Transplant. 2018;33:683\u20139. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfx277\n                    \n                  .","journal-title":"Nephrol Dial Transplant"},{"key":"1567_CR8","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1159\/000450634","volume":"189","author":"B Canaud","year":"2017","unstructured":"Canaud B, Koehler K, Bowry S, Stuard S. What is the optimal target convective volume in on-line hemodiafiltration therapy? Contrib Nephrol. 2017;189:9\u201316. \n                    https:\/\/doi.org\/10.1159\/000450634\n                    \n                  .","journal-title":"Contrib Nephrol"},{"issue":"6","key":"1567_CR9","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1111\/sdi.12715","volume":"31","author":"F Maduell","year":"2018","unstructured":"Maduell F. Hemodiafiltration versus conventional hemodialysis: should \"conventional\" be redefined? Semin Dial. 2018;31(6):625\u201332. \n                    https:\/\/doi.org\/10.1111\/sdi.12715\n                    \n                  .","journal-title":"Semin Dial"},{"issue":"9","key":"1567_CR10","doi-asserted-by":"publisher","first-page":"460","DOI":"10.5301\/ijao.5000525","volume":"39","author":"J Potier","year":"2016","unstructured":"Potier J, Queffeulou G, Bouet J. Are all dialyzers compatible with the convective volumes suggested for postdilution online hemodiafiltration? Int J Artif Organs. 2016;39(9):460\u201370. \n                    https:\/\/doi.org\/10.5301\/ijao.5000525\n                    \n                  .","journal-title":"Int J Artif Organs"},{"key":"1567_CR11","doi-asserted-by":"publisher","unstructured":"Maduell F, Broseta JJ RL, Gomez M, et al. High-permeability alternatives to current dialyzers performing both high-flux hemodialysis and postdilution online hemodiafiltration. Artif Organs. 2019. \n                    https:\/\/doi.org\/10.1111\/aor.13480\n                    \n                  .","DOI":"10.1111\/aor.13480"},{"issue":"12","key":"1567_CR12","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1111\/aor.13278","volume":"42","author":"M Hulko","year":"2018","unstructured":"Hulko M, Haug U, Gauss J, Boschetti-de-Fierro A, Beck W, Krause B. Requirements and pitfalls of dialyzer sieving coefficients comparisons. Artif Organs. 2018;42(12):1164\u201373. \n                    https:\/\/doi.org\/10.1111\/aor.13278\n                    \n                  .","journal-title":"Artif Organs"},{"issue":"14","key":"1567_CR13","doi-asserted-by":"publisher","first-page":"1001","DOI":"10.1056\/NEJM199309303291404","volume":"329","author":"WF Owen Jr","year":"1993","unstructured":"Owen WF Jr, Lew NL, Liu Y, Lowrie EG, Lazarus JM. The urea reduction ratio and serum albumin concentration as predictors of mortality in patients undergoing hemodialysis. N Engl J Med. 1993;329(14):1001\u20136. \n                    https:\/\/doi.org\/10.1056\/NEJM199309303291404\n                    \n                  .","journal-title":"N Engl J Med"},{"key":"1567_CR14","doi-asserted-by":"publisher","unstructured":"van Gelder MK, Abrahams AC, Joles JA, Kaysen GA, Gerritsen KGF. Albumin handling in different hemodialysis modalities. Nephrol Dial Transplant. 2018;33. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfx191\n                    \n                  .","DOI":"10.1093\/ndt\/gfx191"},{"key":"1567_CR15","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1046\/j.1523-1755.1999.00422.x","volume":"55","author":"P Stenvinkel","year":"1999","unstructured":"Stenvinkel P, Heimburger O, Paultre F, Diczfalusy U, Wang T, Berglund L, Jogestrand T. Strong association between malnutrition, inflammation and atherosclerosis in chronic renal failure. Kidney Int. 1999;55:1899\u2013911. \n                    https:\/\/doi.org\/10.1046\/j.1523-1755.1999.00422.x\n                    \n                  .","journal-title":"Kidney Int"},{"issue":"8","key":"1567_CR16","doi-asserted-by":"publisher","first-page":"2421","DOI":"10.1681\/ASN.2005010070","volume":"16","author":"RA Ward","year":"2005","unstructured":"Ward RA. Protein-leaking membranes for hemodialysis: a new class of membranes in search of an application? J Am Soc Nephrol. 2005;16(8):2421\u201330. \n                    https:\/\/doi.org\/10.1681\/ASN.2005010070\n                    \n                  .","journal-title":"J Am Soc Nephrol"},{"key":"1567_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1159\/000328938","volume":"173","author":"A Saito","year":"2011","unstructured":"Saito A. Definition of high-performance membranes \u2013 from the clinical point of view. Contrib Nephrol. 2011;173:1\u201310. \n                    https:\/\/doi.org\/10.1159\/000328938\n                    \n                  .","journal-title":"Contrib Nephrol"},{"key":"1567_CR18","doi-asserted-by":"publisher","first-page":"2006","DOI":"10.1093\/ndt\/gfm065A","volume":"22","author":"R De Smedt","year":"2007","unstructured":"De Smedt R, Dhondt A, Eloot S, Galli F, Waterloos MA, Vanholder R. Effect of the super-flux cellulose triacetate membrane on the removal of non-protein-bound and protein-bound uraemic toxins. Nephrol Dial Transplant. 2007;22:2006\u201312. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfm065A\n                    \n                  .","journal-title":"Nephrol Dial Transplant"},{"key":"1567_CR19","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1111\/j.1523-1755.2005. 67138.x","volume":"67","author":"F Galli","year":"2005","unstructured":"Galli F, Benedetti S, Floridi A, Canestrari F, Piroddi M, Buoncristiani E, Buoncristani U. Glycoxidation and inflammatory markers in patients on treatment with PMMA-based protein-leaking dialyzers. Kidney Int. 2005;67:750\u20139. \n                    https:\/\/doi.org\/10.1111\/j.1523-1755.2005\n                    \n                  . 67138.x.","journal-title":"Kidney Int"},{"key":"1567_CR20","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1159\/000328957","volume":"173","author":"K Tsuchida","year":"2011","unstructured":"Tsuchida K, Minakuchi J. Albumin loss under the use of the high-performance membrane. Contrib Nephrol. 2011;173:76\u201383. \n                    https:\/\/doi.org\/10.1159\/000328957\n                    \n                  .","journal-title":"Contrib Nephrol"},{"issue":"suppl_3","key":"1567_CR21","doi-asserted-by":"publisher","first-page":"iii22","DOI":"10.1093\/ndt\/gfy228","volume":"33","author":"M Storr","year":"2018","unstructured":"Storr M, Ward RA. Membrane innovation: closer to native kidneys. Nephrol Dial Transplant. 2018;33(suppl_3):iii22\u20137. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfy228\n                    \n                  .","journal-title":"Nephrol Dial Transplant"},{"issue":"2","key":"1567_CR22","doi-asserted-by":"publisher","first-page":"76","DOI":"10.5301\/ijao.5000389","volume":"38","author":"A Fournier","year":"2015","unstructured":"Fournier A, Birmele B, Francois M, Prat L, Halimi JM. Factors associated with albumin loss in post-dilution hemodiafiltration. Int J Artif Organs. 2015;38(2):76\u201382. \n                    https:\/\/doi.org\/10.5301\/ijao.5000389\n                    \n                  .","journal-title":"Int J Artif Organs"},{"key":"1567_CR23","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1159\/000468959","volume":"190","author":"C Ronco","year":"2017","unstructured":"Ronco C, La Manna G. Expanded hemodialysis: a new therapy for a new class of membranes. Contrib Nephrol. 2017;190:124\u201333. \n                    https:\/\/doi.org\/10.1159\/000468959\n                    \n                  .","journal-title":"Contrib Nephrol"},{"issue":"1","key":"1567_CR24","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1093\/ndt\/gfw310","volume":"32","author":"AH Kirsch","year":"2017","unstructured":"Kirsch AH, Lyko R, Nilsson LG, Beck W, et al. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant. 2017;32(1):165\u201372. \n                    https:\/\/doi.org\/10.1093\/ndt\/gfw310\n                    \n                  .","journal-title":"Nephrol Dial Transplant"},{"key":"1567_CR25","unstructured":"Bove S, D\u2019Avanzo L, Terlizi V et al. FP458 Comparison of high flux hemodialyzers with medium cut-off dialyzer on the removal of middle high size uremic toxins. Nephrol Dial Transplant. 2018;33, Issue suppl_1, Pages i190. doi.\n                    10.1093, gfy104.FP458\n                    \n                  ."}],"container-title":["BMC Nephrology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12882-019-1567-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12882-019-1567-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12882-019-1567-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,10,27]],"date-time":"2020-10-27T00:05:47Z","timestamp":1603757147000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcnephrol.biomedcentral.com\/articles\/10.1186\/s12882-019-1567-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,28]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1567"],"URL":"https:\/\/doi.org\/10.1186\/s12882-019-1567-8","relation":{},"ISSN":["1471-2369"],"issn-type":[{"value":"1471-2369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,28]]},"assertion":[{"value":"14 May 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 October 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent was obtained from the patient presented in this case report. A signed BMC Nephrology Consent from is available on request.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"392"}}