{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:36:52Z","timestamp":1787758612947,"version":"build-2784847793"},"reference-count":62,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T00:00:00Z","timestamp":1747872000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T00:00:00Z","timestamp":1747872000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82170517"],"award-info":[{"award-number":["82170517"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Basic Research Program from Department of Education of Liaoning Province","award":["JC2019004"],"award-info":[{"award-number":["JC2019004"]}]},{"name":"345 Talent Project of Shengjing Hospital, China Medical University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Nephrol"],"DOI":"10.1186\/s12882-025-04182-4","type":"journal-article","created":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T10:02:46Z","timestamp":1747908166000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Prevailing insights into anastomotic angles of surgically created arteriovenous fistulas: a literature review"],"prefix":"10.1186","volume":"26","author":[{"given":"Xinyang","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haidi","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,5,22]]},"reference":[{"issue":"3","key":"4182_CR1","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1016\/j.semnephrol.2019.02.009","volume":"39","author":"GT Obrador","year":"2019","unstructured":"Obrador GT, Levin A. CKD hotspots: challenges and areas of opportunity. Semin Nephrol. 2019;39(3):308\u201314.","journal-title":"Semin Nephrol"},{"issue":"4","key":"4182_CR2","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.ejvs.2017.06.024","volume":"54","author":"LC Bylsma","year":"2017","unstructured":"Bylsma LC, Gage SM, Reichert H, Dahl SLM, Lawson JH. Arteriovenous fistulae for haemodialysis: A systematic review and Meta-analysis of efficacy and safety outcomes. Eur J Vasc Endovasc Surg. 2017;54(4):513\u201322.","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"9818","key":"4182_CR3","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/S0140-6736(12)60033-6","volume":"379","author":"L Zhang","year":"2012","unstructured":"Zhang L, Wang F, Wang L, Wang W, Liu B, Liu J, et al. Prevalence of chronic kidney disease in China: a cross-sectional survey. Lancet (London England). 2012;379(9818):815\u201322.","journal-title":"Lancet (London England)"},{"issue":"Suppl 1","key":"4182_CR4","doi-asserted-by":"publisher","first-page":"19","DOI":"10.5301\/jva.5000665","volume":"18","author":"A Masengu","year":"2017","unstructured":"Masengu A, Hanko J. Patient factors and haemodialysis arteriovenous fistula outcomes. J Vasc Access. 2017;18(Suppl 1):19\u201323.","journal-title":"J Vasc Access"},{"issue":"18","key":"4182_CR5","doi-asserted-by":"publisher","first-page":"2164","DOI":"10.1001\/jama.299.18.2164","volume":"299","author":"LM Dember","year":"2008","unstructured":"Dember LM, Beck GJ, Allon M, Delmez JA, Dixon BS, Greenberg A, et al. Effect of clopidogrel on early failure of arteriovenous fistulas for hemodialysis: a randomized controlled trial. JAMA. 2008;299(18):2164\u201371.","journal-title":"JAMA"},{"issue":"5","key":"4182_CR6","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.surge.2016.02.001","volume":"14","author":"K Bashar","year":"2016","unstructured":"Bashar K, Conlon PJ, Kheirelseid EA, Aherne T, Walsh SR, Leahy A. Arteriovenous fistula in dialysis patients: factors implicated in early and late AVF maturation failure. Surgeon. 2016;14(5):294\u2013300.","journal-title":"Surgeon"},{"issue":"4","key":"4182_CR7","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1053\/j.semvascsurg.2021.10.010","volume":"34","author":"PR Nelson","year":"2021","unstructured":"Nelson PR, Mallios A, Randel M, Jennings WC. Percutaneous arteriovenous fistula creation. Semin Vasc Surg. 2021;34(4):195\u2013204.","journal-title":"Semin Vasc Surg"},{"issue":"2","key":"4182_CR8","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1053\/j.ajkd.2019.09.014","volume":"75","author":"TS Huber","year":"2020","unstructured":"Huber TS. Surgeon characteristics and arteriovenous fistula maturation success. Am J Kidney Dis. 2020;75(2):151\u20132.","journal-title":"Am J Kidney Dis"},{"issue":"12","key":"4182_CR9","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1001\/jamasurg.2021.4527","volume":"156","author":"TS Huber","year":"2021","unstructured":"Huber TS, Berceli SA, Scali ST, Neal D, Anderson EM, Allon M, et al. Arteriovenous fistula maturation, functional patency, and intervention rates. JAMA Surg. 2021;156(12):1111\u20138.","journal-title":"JAMA Surg"},{"issue":"6","key":"4182_CR10","doi-asserted-by":"publisher","first-page":"1583","DOI":"10.1016\/j.jvs.2015.07.074","volume":"62","author":"N Sadaghianloo","year":"2015","unstructured":"Sadaghianloo N, Jean-Baptiste E, Rajhi K, Fran\u00e7ois E, Declemy S, Dardik A, et al. Increased reintervention in radial-cephalic arteriovenous fistulas with anastomotic angles of less than 30 degrees. J Vasc Surg. 2015;62(6):1583\u20139.","journal-title":"J Vasc Surg"},{"issue":"4","key":"4182_CR11","doi-asserted-by":"publisher","first-page":"284","DOI":"10.5301\/jva.5000721","volume":"18","author":"I Fiorina","year":"2017","unstructured":"Fiorina I, Raciti MV, Goddi A, Cantisani V, Bortolotto C, Chu S, et al. Ultrasound vector flow Imaging - could be a new tool in evaluation of arteriovenous fistulas for hemodialysis? J Vasc Access. 2017;18(4):284\u20139.","journal-title":"J Vasc Access"},{"key":"4182_CR12","doi-asserted-by":"publisher","first-page":"62","DOI":"10.14196\/mjiri.32.62","volume":"32","author":"M Rezapour","year":"2018","unstructured":"Rezapour M, Sepehri MM, Khavanin Zadeh M, Alborzi M. A new method to determine anastomosis angle configuration for arteriovenous fistula maturation. Med J Islam Repub Iran. 2018;32:62.","journal-title":"Med J Islam Repub Iran"},{"issue":"1","key":"4182_CR13","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.jbiomech.2012.09.005","volume":"46","author":"Y He","year":"2013","unstructured":"He Y, Terry CM, Nguyen C, Berceli SA, Shiu YT, Cheung AK. Serial analysis of lumen geometry and hemodynamics in human arteriovenous fistula for Hemodialysis using magnetic resonance imaging and computational fluid dynamics. J Biomech. 2013;46(1):165\u20139.","journal-title":"J Biomech"},{"key":"4182_CR14","doi-asserted-by":"publisher","first-page":"855791","DOI":"10.3389\/fbioe.2022.855791","volume":"10","author":"Y He","year":"2022","unstructured":"He Y, Northrup H, Le H, Cheung AK, Berceli SA, Shiu YT. Medical Image-Based computational fluid dynamics and fluid-Structure interaction analysis in vascular diseases. Front Bioeng Biotechnol. 2022;10:855791.","journal-title":"Front Bioeng Biotechnol"},{"issue":"5","key":"4182_CR15","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1016\/j.jjcc.2022.05.007","volume":"80","author":"H Kamada","year":"2022","unstructured":"Kamada H, Nakamura M, Ota H, Higuchi S, Takase K. Blood flow analysis with computational fluid dynamics and 4D-flow MRI for vascular diseases. J Cardiol. 2022;80(5):386\u201396.","journal-title":"J Cardiol"},{"key":"4182_CR16","doi-asserted-by":"crossref","unstructured":"Soliveri L, Bozzetto M, Brambilla P, Caroli A, Remuzzi A. Hemodynamics in AVF over time: A protective role of vascular remodeling toward flow stabilization. Int J Artif Organs. 2023;46(10\u201311):547\u201354:3913988231191960.","DOI":"10.1177\/03913988231191960"},{"issue":"11","key":"4182_CR17","doi-asserted-by":"publisher","first-page":"714","DOI":"10.1177\/0391398818784207","volume":"41","author":"M Bozzetto","year":"2018","unstructured":"Bozzetto M, Brambilla P, Rota S, Ene-Iordache B, Sironi S, Remuzzi G, et al. Toward longitudinal studies of hemodynamically induced vessel wall remodeling. Int J Artif Organs. 2018;41(11):714\u201322.","journal-title":"Int J Artif Organs"},{"key":"4182_CR18","doi-asserted-by":"publisher","first-page":"846","DOI":"10.3389\/fbioe.2020.00846","volume":"8","author":"CY Yang","year":"2020","unstructured":"Yang CY, Li MC, Lan CW, Lee WJ, Lee CJ, Wu CH, et al. The anastomotic angle of Hemodialysis arteriovenous fistula is associated with flow disturbance at the venous stenosis location on angiography. Front Bioeng Biotechnol. 2020;8:846.","journal-title":"Front Bioeng Biotechnol"},{"issue":"1","key":"4182_CR19","first-page":"109","volume":"32","author":"G Gali\u0107","year":"2008","unstructured":"Gali\u0107 G, Kvesi\u0107 A, Tomi\u0107 M, Rebac Z, Brekalo Z, Martinovi\u0107 V, et al. The advantages of end-to-side arteriovenous anastomosis over the other two types of arteriovenous anastomosis in dialysis patients. Coll Antropol. 2008;32(1):109\u201314.","journal-title":"Coll Antropol"},{"issue":"6","key":"4182_CR20","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.ejvs.2018.02.001","volume":"55","author":"J Schmidli","year":"2018","unstructured":"Schmidli J, Widmer MK, Basile C, de Donato G, Gallieni M, Gibbons CP et al. Editor\u2019s Choice 2018 Vascular access: 2018 clinical practice guidelines of the European society for vascular surgery (ESVS). Eur J Vasc Endovasc Surg 55 6 757\u2013818.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"4182_CR21","doi-asserted-by":"crossref","unstructured":"Xu W, Lu G, Tang W, Gong L, Lu J. Comparison of different anastomosis angles in radiocephalic fistula with modified functional end-to-side anastomosis. Int Urol Nephrol. 2023;55(12):3237\u201343.","DOI":"10.1007\/s11255-023-03608-y"},{"issue":"1","key":"4182_CR22","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1093\/ndt\/14.1.118","volume":"14","author":"S Sivanesan","year":"1999","unstructured":"Sivanesan S, How TV, Bakran A. Sites of stenosis in AV fistulae for haemodialysis access. Nephrol Dial Transpl. 1999;14(1):118\u201320.","journal-title":"Nephrol Dial Transpl"},{"issue":"6","key":"4182_CR23","doi-asserted-by":"publisher","first-page":"512","DOI":"10.5301\/jva.5000607","volume":"17","author":"J Lee","year":"2016","unstructured":"Lee J, Kim S, Kim SM, Song R, Kim HK, Park JS, et al. Assessing radiocephalic wrist arteriovenous fistulas of obtuse anastomosis using computational fluid dynamics and clinical application. J Vasc Access. 2016;17(6):512\u201320.","journal-title":"J Vasc Access"},{"issue":"5","key":"4182_CR24","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1016\/j.jvs.2020.09.033","volume":"73","author":"Y He","year":"2021","unstructured":"He Y, Northrup H, Roy-Chaudhury P, Cheung AK, Berceli SA, Shiu YT. Analyses of Hemodialysis arteriovenous fistula geometric configuration and its associations with maturation and reintervention. J Vasc Surg. 2021;73(5):1778\u2013e861.","journal-title":"J Vasc Surg"},{"issue":"Suppl 1","key":"4182_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.5301\/jva.5000698","volume":"18","author":"S Shenoy","year":"2017","unstructured":"Shenoy S. Surgical technique determines the outcome of the Brescia\/Cimino AVF. J Vasc Access. 2017;18(Suppl 1):1\u20134.","journal-title":"J Vasc Access"},{"issue":"1","key":"4182_CR26","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1016\/j.jvs.2011.07.090","volume":"55","author":"A Bharat","year":"2012","unstructured":"Bharat A, Jaenicke M, Shenoy S. A novel technique of vascular anastomosis to prevent juxta-anastomotic stenosis following arteriovenous fistula creation. J Vasc Surg. 2012;55(1):274\u201380.","journal-title":"J Vasc Surg"},{"issue":"6","key":"4182_CR27","doi-asserted-by":"publisher","first-page":"515","DOI":"10.5301\/jva.5000764","volume":"18","author":"M Darcy","year":"2017","unstructured":"Darcy M, Vachharajani N, Zhang T, Mani N, Kim SK, Matson S, et al. Long-term outcome of upper extremity arteriovenous fistula using pSLOT: single-center longitudinal follow-up using a protocol-based approach. J Vasc Access. 2017;18(6):515\u201321.","journal-title":"J Vasc Access"},{"key":"4182_CR28","doi-asserted-by":"crossref","unstructured":"LoBue A, Heuser SK, Lindemann M, Li J, Rahman M, Kelm M et al. Red blood cell endothelial nitric oxide synthase: A major player in regulating cardiovascular health. Br J Pharmacol. 2023.","DOI":"10.1111\/bph.16230"},{"issue":"13\u201315","key":"4182_CR29","doi-asserted-by":"publisher","first-page":"1001","DOI":"10.1089\/ars.2023.0006","volume":"38","author":"T M\u00fcnzel","year":"2023","unstructured":"M\u00fcnzel T, Daiber A. Vascular redox signaling, endothelial nitric oxide synthase uncoupling, and endothelial dysfunction in the setting of transportation noise exposure or chronic treatment with organic nitrates. Antioxid Redox Signal. 2023;38(13\u201315):1001\u201321.","journal-title":"Antioxid Redox Signal"},{"key":"4182_CR30","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.jvssci.2020.03.001","volume":"1","author":"T Kudze","year":"2020","unstructured":"Kudze T, Ono S, Fereydooni A, Gonzalez L, Isaji T, Hu H, et al. Altered hemodynamics during arteriovenous fistula remodeling leads to reduced fistula patency in female mice. JVS Vasc Sci. 2020;1:42\u201356.","journal-title":"JVS Vasc Sci"},{"issue":"7","key":"4182_CR31","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1161\/ATVBAHA.120.314172","volume":"40","author":"J Huang","year":"2020","unstructured":"Huang J, Cai C, Zheng T, Wu X, Wang D, Zhang K, et al. Endothelial scaffolding protein ENH (Enigma homolog protein) promotes PHLPP2 (Pleckstrin homology domain and Leucine-Rich repeat protein phosphatase 2)-Mediated dephosphorylation of AKT1 and eNOS (Endothelial NO Synthase) promoting vascular remodeling. Arterioscler Thromb Vasc Biol. 2020;40(7):1705\u201321.","journal-title":"Arterioscler Thromb Vasc Biol"},{"issue":"3","key":"4182_CR32","doi-asserted-by":"publisher","first-page":"732","DOI":"10.14336\/AD.2020.0523","volume":"12","author":"L An","year":"2021","unstructured":"An L, Shen Y, Chopp M, Zacharek A, Venkat P, Chen Z, et al. Deficiency of endothelial nitric oxide synthase (eNOS) exacerbates brain damage and cognitive deficit in A mouse model of vascular dementia. Aging Dis. 2021;12(3):732\u201346.","journal-title":"Aging Dis"},{"issue":"18","key":"4182_CR33","doi-asserted-by":"publisher","first-page":"e016471","DOI":"10.1161\/JAHA.120.016471","volume":"9","author":"S Gauer","year":"2020","unstructured":"Gauer S, Balint B, Kollmann C, Federspiel JM, Henn D, Bandner-Risch D, et al. Dysregulation of endothelial nitric oxide synthase does not depend on hemodynamic alterations in bicuspid aortic valve aortopathy. J Am Heart Assoc. 2020;9(18):e016471.","journal-title":"J Am Heart Assoc"},{"issue":"3","key":"4182_CR34","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1177\/1129729821996537","volume":"23","author":"H Bai","year":"2022","unstructured":"Bai H, Wei S, Xie B, Wang Z, Li M, Qiao Z, et al. Endothelial nitric oxide synthase (eNOS) mediates neointimal thickness in arteriovenous fistulae with different anastomotic angles in rats. J Vasc Access. 2022;23(3):403\u201311.","journal-title":"J Vasc Access"},{"issue":"9","key":"4182_CR35","doi-asserted-by":"publisher","first-page":"925","DOI":"10.34067\/KID.0001832020","volume":"1","author":"I Falzon","year":"2020","unstructured":"Falzon I, Northrup H, Guo L, Totenhagen J, Lee T, Shiu YT. The geometry of arteriovenous fistulas using endothelial nitric oxide synthase mouse models. Kidney360. 2020;1(9):925\u201335.","journal-title":"Kidney360"},{"key":"4182_CR36","doi-asserted-by":"publisher","first-page":"779043","DOI":"10.3389\/fbioe.2021.779043","volume":"9","author":"H Northrup","year":"2021","unstructured":"Northrup H, Somarathna M, Corless S, Falzon I, Totenhagen J, Lee T, et al. Analysis of geometric and hemodynamic profiles in rat arteriovenous fistula following PDE5A Inhibition. Front Bioeng Biotechnol. 2021;9:779043.","journal-title":"Front Bioeng Biotechnol"},{"issue":"20","key":"4182_CR37","doi-asserted-by":"publisher","first-page":"2049","DOI":"10.1016\/j.jcin.2022.08.046","volume":"15","author":"H Samady","year":"2022","unstructured":"Samady H, Jaber W. Harnessing vascular biology and fluid dynamics to risk stratify patients with acute coronary syndromes. JACC Cardiovasc Interv. 2022;15(20):2049\u201351.","journal-title":"JACC Cardiovasc Interv"},{"key":"4182_CR38","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/978-3-030-63453-7_4","volume":"132","author":"F Ishida","year":"2021","unstructured":"Ishida F, Tsuji M, Tanioka S, Tanaka K, Yoshimura S, Suzuki H. Computational fluid dynamics for cerebral aneurysms in clinical settings. Acta Neurochir Suppl. 2021;132:27\u201332.","journal-title":"Acta Neurochir Suppl"},{"key":"4182_CR39","doi-asserted-by":"crossref","unstructured":"Fulker D, Ene-Iordache B, Barber T. High-Resolution computational fluid dynamic simulation of haemodialysis cannulation in a Patient-Specific arteriovenous fistula. J Biomech Eng. 2018;140(3).","DOI":"10.1115\/1.4038289"},{"issue":"3","key":"4182_CR40","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1177\/1129729820944069","volume":"22","author":"J Krampf","year":"2021","unstructured":"Krampf J, Agarwal R, Shenoy S. Contribution of inflow artery to observed flow in a vascular access: A computational fluid dynamic modeling study of an arteriovenous fistula circuit. J Vasc Access. 2021;22(3):417\u201323.","journal-title":"J Vasc Access"},{"issue":"Suppl 1","key":"4182_CR41","doi-asserted-by":"publisher","first-page":"10","DOI":"10.5301\/jva.5000686","volume":"18","author":"A Remuzzi","year":"2017","unstructured":"Remuzzi A, Bozzetto M, Brambilla P. Is shear stress the key factor for AVF maturation? J Vasc Access. 2017;18(Suppl 1):10\u20134.","journal-title":"J Vasc Access"},{"key":"4182_CR42","doi-asserted-by":"crossref","unstructured":"Lancellotti RM, Vergara C, Valdettaro L, Bose S, Quarteroni A. Large eddy simulations for blood dynamics in realistic stenotic carotids. Int J Numer Method Biomed Eng. 2017;33(11).","DOI":"10.1002\/cnm.2868"},{"key":"4182_CR43","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.avsg.2020.04.004","volume":"68","author":"G Prouse","year":"2020","unstructured":"Prouse G, Stella S, Vergara C, Quarteroni A, Engelberger S, Canevascini R, et al. Computational analysis of turbulent hemodynamics in radiocephalic arteriovenous fistulas to determine the best anastomotic angles. Ann Vasc Surg. 2020;68:451\u20139.","journal-title":"Ann Vasc Surg"},{"key":"4182_CR44","doi-asserted-by":"crossref","unstructured":"Stella S, Vergara C, Giovannacci L, Quarteroni A, Prouse G. Assessing the disturbed flow and the transition to turbulence in the arteriovenous fistula. J Biomech Eng. 2019;141(10).","DOI":"10.1115\/1.4043448"},{"issue":"12","key":"4182_CR45","doi-asserted-by":"publisher","first-page":"e3259","DOI":"10.1002\/cnm.3259","volume":"35","author":"CV Cunnane","year":"2019","unstructured":"Cunnane CV, Cunnane EM, Moran DT, Walsh MT. The presence of helical flow can suppress areas of disturbed shear in parameterised models of an arteriovenous fistula. Int J Numer Method Biomed Eng. 2019;35(12):e3259.","journal-title":"Int J Numer Method Biomed Eng"},{"issue":"4","key":"4182_CR46","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1093\/ndt\/gfs298","volume":"28","author":"B Ene-Iordache","year":"2013","unstructured":"Ene-Iordache B, Cattaneo L, Dubini G, Remuzzi A. Effect of anastomosis angle on the localization of disturbed flow in \u2018side-to-end\u2019 fistulae for haemodialysis access. Nephrol Dial Transpl. 2013;28(4):997\u20131005.","journal-title":"Nephrol Dial Transpl"},{"issue":"1","key":"4182_CR47","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1177\/112972981001100111","volume":"11","author":"K Van Canneyt","year":"2010","unstructured":"Van Canneyt K, Pourchez T, Eloot S, Guillame C, Bonnet A, Segers P, et al. Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: a computer analysis. J Vasc Access. 2010;11(1):52\u20138.","journal-title":"J Vasc Access"},{"issue":"1","key":"4182_CR48","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.jvs.2012.10.070","volume":"58","author":"JE Hull","year":"2013","unstructured":"Hull JE, Balakin BV, Kellerman BM, Wrolstad DK. Computational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula. J Vasc Surg. 2013;58(1):187\u2013e931.","journal-title":"J Vasc Surg"},{"issue":"3","key":"4182_CR49","doi-asserted-by":"publisher","first-page":"131","DOI":"10.4236\/jbise.2015.83013","volume":"08","author":"J Silva JdA, Karam-Filho","year":"2015","unstructured":"Silva JdA, Karam-Filho J, Borges CCH. Computational analysis of anastomotic angles by blood flow conditions in Side-to-End Radio-Cephalic fistulae used in Hemodialysis. J Biomedical Sci Eng. 2015;08(3):131\u201341.","journal-title":"J Biomedical Sci Eng"},{"issue":"2","key":"4182_CR50","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1111\/nep.13219","volume":"24","author":"J Carroll","year":"2019","unstructured":"Carroll J, Varcoe RL, Barber T, Simmons A. Reduction in anastomotic flow disturbance within a modified end-to-side arteriovenous fistula configuration: results of a computational flow dynamic model. Nephrol (Carlton). 2019;24(2):245\u201351.","journal-title":"Nephrol (Carlton)"},{"issue":"4","key":"4182_CR51","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1111\/sdi.12045","volume":"26","author":"E Rajabi-Jagahrgh","year":"2013","unstructured":"Rajabi-Jagahrgh E, Krishnamoorthy MK, Wang Y, Choe A, Roy-Chaudhury P, Banerjee RK. Influence of Temporal variation in wall shear stress on intima-media thickening in arteriovenous fistulae. Semin Dial. 2013;26(4):511\u20139.","journal-title":"Semin Dial"},{"issue":"12","key":"4182_CR52","doi-asserted-by":"publisher","first-page":"e0145795","DOI":"10.1371\/journal.pone.0145795","volume":"10","author":"LD Browne","year":"2015","unstructured":"Browne LD, Bashar K, Griffin P, Kavanagh EG, Walsh SR, Walsh MT. The role of shear stress in arteriovenous fistula maturation and failure: A systematic review. PLoS ONE. 2015;10(12):e0145795.","journal-title":"PLoS ONE"},{"issue":"3","key":"4182_CR53","doi-asserted-by":"publisher","first-page":"243","DOI":"10.5301\/jva.5000527","volume":"17","author":"E Chemla","year":"2016","unstructured":"Chemla E, Velazquez CC, D\u2019Abate F, Ramachandran V, Maytham G. Arteriovenous fistula construction with the VasQ\u2122 external support device: a pilot study. J Vasc Access. 2016;17(3):243\u20138.","journal-title":"J Vasc Access"},{"issue":"5","key":"4182_CR54","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1016\/j.jvs.2023.07.054","volume":"78","author":"ED Dillavou","year":"2023","unstructured":"Dillavou ED, Lucas JF, Woodside K, Burgess J, Farber A, Hentschel D, et al. VasQ U.S. Pivotal study demonstrates the safety and effectiveness of an external vascular support for arteriovenous fistula creation. J Vasc Surg. 2023;78(5):1302\u2013e123.","journal-title":"J Vasc Surg"},{"issue":"4","key":"4182_CR55","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1177\/11297298211002570","volume":"23","author":"F Benedetto","year":"2022","unstructured":"Benedetto F, Spinelli D, Derone G, Cutrupi A, Barill\u00e0 D, Pipit\u00f2 N. Initial single-center experience with a new external support device for the creation of the forearm native arteriovenous fistula for Hemodialysis. J Vasc Access. 2022;23(4):524\u201331.","journal-title":"J Vasc Access"},{"issue":"1","key":"4182_CR56","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1016\/j.jvs.2021.07.120","volume":"75","author":"R Shahverdyan","year":"2022","unstructured":"Shahverdyan R, Tabbi P, Mestres G. Multicenter European real-world utilization of VasQ anastomotic external support device for arteriovenous fistulae. J Vasc Surg. 2022;75(1):248\u201354.","journal-title":"J Vasc Surg"},{"issue":"2","key":"4182_CR57","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1177\/1129729820904599","volume":"22","author":"R Shahverdyan","year":"2021","unstructured":"Shahverdyan R, Meyer T, Matoussevitch V. Patency and functionality of radiocephalic arteriovenous fistulas with an external support device (VasQ\u2122): Real-world single-center experience. J Vasc Access. 2021;22(2):166\u201372.","journal-title":"J Vasc Access"},{"issue":"4","key":"4182_CR58","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1177\/1129729820971533","volume":"22","author":"G Leonardi","year":"2021","unstructured":"Leonardi G, Campagna M, Pellican\u00f2 V, Guarena C, Bergamo D, Lavacca A, et al. Implanted blood vessel external support device (VasQ\u2122) for creation of Hemodialysis arteriovenous fistula: A single-center experience. J Vasc Access. 2021;22(4):658\u201365.","journal-title":"J Vasc Access"},{"issue":"2","key":"4182_CR59","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1111\/sdi.13065","volume":"36","author":"R Shahverdyan","year":"2023","unstructured":"Shahverdyan R, Hentschel DM. Achieving high maturation and cannulation rates of radial-cephalic arteriovenous fistulas with VasQ\u2122 device. Semin Dial. 2023;36(2):147\u201354.","journal-title":"Semin Dial"},{"key":"4182_CR60","doi-asserted-by":"crossref","unstructured":"Bozzetto M, Soliveri L, Poloni S, Brambilla P, Curt\u00f2 D, Condemi GC et al. Arteriovenous fistula creation with VasQ(TM) device: A feasibility study to reveal hemodynamic implications. J Vasc Access. 2022:11297298221087160.","DOI":"10.1177\/11297298221087160"},{"issue":"1","key":"4182_CR61","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1177\/1129729820983153","volume":"23","author":"R Palumbo","year":"2022","unstructured":"Palumbo R, Dominijanni S, Centi A, D\u2019Urso G, Tatangelo P, Floccari F, et al. Hemodynamic impact of VASQ device in vascular access creation. J Vasc Access. 2022;23(1):105\u20138.","journal-title":"J Vasc Access"},{"issue":"1","key":"4182_CR62","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1053\/j.ajkd.2019.05.023","volume":"75","author":"N Karydis","year":"2020","unstructured":"Karydis N, Bevis P, Beckitt T, Silverberg D, Halak M, Calder F. An implanted blood vessel support device for arteriovenous fistulas: A randomized controlled trial. Am J Kidney Dis. 2020;75(1):45\u201353.","journal-title":"Am J Kidney Dis"}],"container-title":["BMC Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12882-025-04182-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12882-025-04182-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12882-025-04182-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T11:04:41Z","timestamp":1747911881000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcnephrol.biomedcentral.com\/articles\/10.1186\/s12882-025-04182-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,22]]},"references-count":62,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4182"],"URL":"https:\/\/doi.org\/10.1186\/s12882-025-04182-4","relation":{},"ISSN":["1471-2369"],"issn-type":[{"value":"1471-2369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,22]]},"assertion":[{"value":"6 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This paper is a review study and does not involve this content.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This paper is a review study and does not involve this content.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent to participate"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"252"}}