{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T05:27:12Z","timestamp":1789018032119,"version":"build-2803163510"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,17]],"date-time":"2025-07-17T00:00:00Z","timestamp":1752710400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,17]],"date-time":"2025-07-17T00:00:00Z","timestamp":1752710400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Nephrol"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Establishing and maintaining a functional vascular access is essential for patients with end-stage kidney disease on home hemodialysis. Due to patient safety concerns about vascular access complications, particularly needle dislodgement causing bleeding, various technologies have emerged. The purpose of this study was to investigate whether a novel device (developed by Redsense Medical AB) consisting of a sensor placed at the venous puncture site and linked to a base unit with wireless connection to a clamp on the venous line is acceptable from a patient perspective and feasible for implementation in a home hemodialysis program. This was a prospective cohort study of patients undergoing home hemodialysis at the University Health Network in Toronto, Ontario, Canada. We conducted a mixed methods study with a convergent parallel design, collecting both quantitative and qualitative data through two patient questionnaires whereby patients rated their experience with the Redsense system after their first 1\u20133 treatments and after their last treatment with the system. Thematic analysis was performed with use of open coding and axial coding. Quantitative data was presented as a heat map depicting participants\u2019 scoring of the Redsense system. Differences between the two questionnaires were assessed by Wilcoxon matched-pairs signed rank tests, and the response to select questions were depicted graphically. 21 patients consented to participate in this study, completing a total of 218 dialysis treatments with the Redsense system. Over these treatments, the system was shown to be safe and feasible for patients to use independently at home. The alarm had a relatively elevated false positive rate for both alarm triggering and clamp closure, with this sentiment well described in the qualitative data, as the nuisance of false alarms was a frequent concern described in the post-treatment questionnaire. Patients had other negative comments related to the practicality of the alarm system, the additional burden created, and concern about technical issues relating to wireless technology. Taken together, the data from this study suggest that most patients performing home hemodialysis independently feel that the potential benefits of the Redsense alarm system are outweighed by the additional burden and other negatives associated with the system.<\/jats:p>","DOI":"10.1186\/s12882-025-04332-8","type":"journal-article","created":{"date-parts":[[2025,7,17]],"date-time":"2025-07-17T18:22:06Z","timestamp":1752776526000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["An integrated alarm with clamp system to mitigate vascular access bleeding in hemodialysis: a prospective cohort mixed methods study"],"prefix":"10.1186","volume":"26","author":[{"given":"Ryan J.","family":"Chan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Margaret","family":"McGrath-Chong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher T. M.","family":"Chan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,17]]},"reference":[{"issue":"11","key":"4332_CR1","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.1001\/jama.298.11.1291","volume":"298","author":"BF Culleton","year":"2007","unstructured":"Culleton BF, Walsh M, Klarenbach SW, Mortis G, Scott-Douglas N, Quinn RR, et al. Effect of frequent nocturnal hemodialysis vs conventional hemodialysis on left ventricular mass and quality of life: A randomized controlled trial. JAMA. 2007;298(11):1291.","journal-title":"JAMA"},{"issue":"6","key":"4332_CR2","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1053\/j.ajkd.2021.01.025","volume":"78","author":"SD Bieber","year":"2021","unstructured":"Bieber SD, Young BA. Home hemodialysis: core curriculum 2021. Am J Kidney Dis. 2021;78(6):876\u201385.","journal-title":"Am J Kidney Dis"},{"key":"4332_CR3","doi-asserted-by":"crossref","unstructured":"Rioux J, Marshall MR, Faratro R, Hakim R, Simmonds R, Chan CT. Patient selection and training for home hemodialysis. Hemodial Int [Internet]. 2015 Apr [cited 2024 Jan 27];19(S1). Available from: https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/hdi.12254","DOI":"10.1111\/hdi.12254"},{"issue":"1","key":"4332_CR4","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1053\/j.ajkd.2014.08.013","volume":"65","author":"KK Tennankore","year":"2015","unstructured":"Tennankore KK, d\u2019Gama C, Faratro R, Fung S, Wong E, Chan CT. Adverse technical events in home Hemodialysis. Am J Kidney Dis. 2015;65(1):116\u201321.","journal-title":"Am J Kidney Dis"},{"issue":"2","key":"4332_CR5","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1111\/j.1542-4758.2008.00263.x","volume":"12","author":"J Ahlm\u00e9n","year":"2008","unstructured":"Ahlm\u00e9n J, Gydell K, Hadimeri H, Hernandez I, Rogland B, Str\u00f6mbom U. A new safety device for Hemodialysis. Hemodial Int. 2008;12(2):264\u20137.","journal-title":"Hemodial Int"},{"issue":"4","key":"4332_CR6","doi-asserted-by":"publisher","first-page":"e476","DOI":"10.34067\/KID.0000000000000093","volume":"4","author":"S Frinak","year":"2023","unstructured":"Frinak S, Kennedy J, Zasuwa G, Passalacqua KD, Yee J. Detection of Hemodialysis venous needle dislodgment using venous access pressure measurements: A simulation study. Kidney360. 2023;4(4):e476\u201385.","journal-title":"Kidney360"},{"issue":"2","key":"4332_CR7","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1111\/hdi.12737","volume":"23","author":"C Kennedy","year":"2019","unstructured":"Kennedy C, McGrath-Chong M, Arustei D, d\u2019Gama C, Faratro R, Fung S, et al. A prototype line clamp for venous access bleeding in hemodialysis: A prospective cohort study. Hemodial Int. 2019;23(2):151\u20137.","journal-title":"Hemodial Int"},{"key":"4332_CR8","unstructured":"Redsense Medical AB. Redsense Instructions for Use [Internet]. Available from: https:\/\/redsensemedical.com\/wp-content\/uploads\/IFU_CVC_RM_1_RM248.pdf"},{"issue":"6pt2","key":"4332_CR9","doi-asserted-by":"publisher","first-page":"2134","DOI":"10.1111\/1475-6773.12117","volume":"48","author":"MD Fetters","year":"2013","unstructured":"Fetters MD, Curry LA, Creswell JW. Achieving integration in mixed methods Designs\u2014Principles and practices. Health Serv Res. 2013;48(6pt2):2134\u201356.","journal-title":"Health Serv Res"},{"issue":"10","key":"4332_CR10","doi-asserted-by":"publisher","first-page":"1080","DOI":"10.1038\/ki.2011.213","volume":"80","author":"MV Rocco","year":"2011","unstructured":"Rocco MV, Lockridge RS, Beck GJ, Eggers PW, Gassman JJ, Greene T, et al. The effects of frequent nocturnal home hemodialysis: the frequent Hemodialysis network nocturnal trial. Kidney Int. 2011;80(10):1080\u201391.","journal-title":"Kidney Int"},{"issue":"4","key":"4332_CR11","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1053\/j.ajkd.2019.12.001","volume":"75","author":"CE Lok","year":"2020","unstructured":"Lok CE, Huber TS, Lee T, Shenoy S, Yevzlin AS, Abreo K, et al. KDOQI clinical practice guideline for vascular access: 2019 update. Am J Kidney Dis. 2020;75(4):S1\u2013164.","journal-title":"Am J Kidney Dis"},{"issue":"8","key":"4332_CR12","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.2215\/CJN.0000000000000499","volume":"19","author":"RJ Chan","year":"2024","unstructured":"Chan RJ, Chan CT. Vascular access considerations in home Hemodialysis. Clin J Am Soc Nephrol. 2024;19(8):1036\u201344.","journal-title":"Clin J Am Soc Nephrol"},{"issue":"5","key":"4332_CR13","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1186\/cc2851","volume":"8","author":"G Gutierrez","year":"2004","unstructured":"Gutierrez G, Reines HD, Wulf-Gutierrez ME. Hemorrhagic shock. Crit Care. 2004;8(5):373.","journal-title":"Crit Care"},{"issue":"5","key":"4332_CR14","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1111\/sdi.12169","volume":"27","author":"W Ribitsch","year":"2014","unstructured":"Ribitsch W, Schilcher G, Hafner-Giessauf H, Krisper P, Horina JH, Rosenkranz AR, et al. Prevalence of detectable venous pressure drops expected with venous needle dislodgement. Semin Dial. 2014;27(5):507\u201311.","journal-title":"Semin Dial"},{"issue":"4","key":"4332_CR15","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1053\/ajkd.2002.35687","volume":"40","author":"S Frinak","year":"2002","unstructured":"Frinak S, Zasuwa G, Dunfee T, Besarab A, Yee J. Dynamic venous access pressure ratio test for hemodialysis access monitoring. Am J Kidney Dis. 2002;40(4):760\u20138.","journal-title":"Am J Kidney Dis"},{"issue":"2","key":"4332_CR16","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1053\/j.ajkd.2013.07.009","volume":"63","author":"B Wong","year":"2014","unstructured":"Wong B, Zimmerman D, Reintjes F, Courtney M, Klarenbach S, Dowling G, et al. Procedure-Related serious adverse events among home Hemodialysis patients: A quality assurance perspective. Am J Kidney Dis. 2014;63(2):251\u20138.","journal-title":"Am J Kidney Dis"},{"key":"4332_CR17","doi-asserted-by":"crossref","unstructured":"Faratro R, Jeffries J, Nesrallah GE, MacRae JM. The care and keeping of vascular access for home hemodialysis patients. Hemodial Int [Internet]. 2015 Apr [cited 2024 Jan 20];19(S1). Available from: https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/hdi.12242","DOI":"10.1111\/hdi.12242"},{"key":"4332_CR18","unstructured":"El Shamy O, Abra G, Chan C. Patient-centered home hemodialysis: approaches and prescription. Clin J Am Soc Nephrol [Internet]. 2023 Aug 28 [cited 2023 Nov 14]; Available from: https:\/\/journals.lww.com\/10.2215\/CJN.0000000000000292"},{"issue":"3","key":"4332_CR19","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1053\/j.ajkd.2014.10.020","volume":"65","author":"RC Walker","year":"2015","unstructured":"Walker RC, Hanson CS, Palmer SC, Howard K, Morton RL, Marshall MR, et al. Patient and caregiver perspectives on home hemodialysis: a systematic review. Am J Kidney Dis Off J Natl Kidney Found. 2015;65(3):451\u201363.","journal-title":"Am J Kidney Dis Off J Natl Kidney Found"},{"issue":"sp","key":"4332_CR20","doi-asserted-by":"publisher","first-page":"24","DOI":"10.12927\/hcq.2012.22845","volume":"15","author":"J Cafazzo","year":"2012","unstructured":"Cafazzo J, St-Cyr O. From discovery to design: the evolution of human factors in healthcare. Healthc Q. 2012;15(sp):24\u20139.","journal-title":"Healthc Q"}],"container-title":["BMC Nephrology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12882-025-04332-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12882-025-04332-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12882-025-04332-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,7]],"date-time":"2025-09-07T13:11:58Z","timestamp":1757250718000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcnephrol.biomedcentral.com\/articles\/10.1186\/s12882-025-04332-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,17]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4332"],"URL":"https:\/\/doi.org\/10.1186\/s12882-025-04332-8","relation":{},"ISSN":["1471-2369"],"issn-type":[{"value":"1471-2369","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,17]]},"assertion":[{"value":"1 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval is provided by University Health Network Research Ethics Board (17-5571) in accordance with the Declaration of Helsinki. Informed consent was obtained from all participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"398"}}