{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T13:57:03Z","timestamp":1781272623384,"version":"3.54.1"},"reference-count":10,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,4]],"date-time":"2022-02-04T00:00:00Z","timestamp":1643932800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,4]],"date-time":"2022-02-04T00:00:00Z","timestamp":1643932800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Neurol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The aim of this study was to develop a screening score system of non-contrast transthoracic echocardiography (TTE) for patent foramen ovale (PFO) in patients with embolic stroke of undetermined source (ESUS).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We performed a retrospective analysis of 218 consecutive patients with a recent ESUS from 2015 to 2018, who received TTE and transcranial Doppler (TCD) as routine examinations. PFO was diagnosed by the bubble test of TCD. Significant differences of the non-contrast TTE findings and patient characteristics between PFO group and non-PFO group were selected into a score.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>PFO was diagnosed in 35.8% (78\/218) of the patients. Compared with non-PFO group, a larger median aortic root diameter (ARd) (34\u2009mm vs. 32\u2009mm, <jats:italic>p<\/jats:italic>\u2009=\u20090.005), a lower median peak E wave velocity (Em) (61.5\u2009cm\/s vs. 68\u2009cm\/s, <jats:italic>p<\/jats:italic>\u2009=\u20090.005) and a lower incidence rate of mitral regurgitation (34.6% vs. 50.7%, <jats:italic>p<\/jats:italic>\u2009=\u20090.022) were seen in PFO group. ARd&gt;33\u2009mm and Em\u2009&lt;\u200972\u2009cm\/s were the best thresholds to predict PFO in ROC analysis. A four-point score system (MEAD) including TTE criteria (including ARd&gt;33\u2009mm, Em\u2009&lt;\u200972\u2009cm\/s and without mitral regurgitation) and no history of diabetes predicted PFO with an area under curve of 0.67 (95%CI 0.57\u20130.72, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). MEAD score\u00a0\u2265\u00a03 was the best threshold to predict PFO with an accuracy of 0.64 (95% CI 0.57\u20130.7), a sensitivity of 0.65 (95% CI 0.53\u20130.75) and a specificity of 0.63 (95% CI 0.55\u20130.71).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The MEAD score measured with non-contrast TTE can be used to select patients for bubble test\u00a0of TCD to increase the diagnostic yield of PFO after ESUS.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12883-022-02565-w","type":"journal-article","created":{"date-parts":[[2022,2,4]],"date-time":"2022-02-04T16:13:28Z","timestamp":1643991208000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A score of non-contrast transthoracic echocardiography to screen patent foramen ovale in patients with embolic stroke of undetermined source"],"prefix":"10.1186","volume":"22","author":[{"given":"Hui","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haiyan","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjie","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,4]]},"reference":[{"key":"2565_CR1","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1016\/S1474-4422(13)70310-7","volume":"13","author":"RG Hart","year":"2014","unstructured":"Hart RG, Diener HC, Coutts SB, et al. Embolic strokes of undetermined source: the case for a new clinical construct. Lancet Neurol. 2014;13:429\u201338.","journal-title":"Lancet Neurol"},{"key":"2565_CR2","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/0735-1097(91)90705-E","volume":"17","author":"AC Pearson","year":"1991","unstructured":"Pearson AC, Labovitz AJ, Tatineni S, Gomez CR. Superiority of transesophageal echocardiography in detecting cardiac source of embolism in patients with cerebral ischemia of uncertain etiology. J Am Coll Cardiol. 1991;17:66\u201372.","journal-title":"J Am Coll Cardiol"},{"key":"2565_CR3","doi-asserted-by":"publisher","first-page":"2343","DOI":"10.1161\/STROKEAHA.109.549683","volume":"40","author":"JR Romero","year":"2009","unstructured":"Romero JR, Frey JL, Schwamm LH, et al. Cerebral ischemic events associated with 'bubble study' for identification of right to left shunts. Stroke. 2009;40:2343\u20138.","journal-title":"Stroke"},{"key":"2565_CR4","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1212\/WNL.0b013e3182a08d59","volume":"81","author":"DM Kent","year":"2013","unstructured":"Kent DM, Ruthazer R, Weimar C, et al. An index to identify stroke-related vs incidental patent foramen ovale in cryptogenic stroke. Neurology. 2013;81:619\u201325.","journal-title":"Neurology"},{"key":"2565_CR5","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1186\/1476-7120-12-16","volume":"12","author":"M Komar","year":"2014","unstructured":"Komar M, Olszowska M, Przewlocki T, et al. Transcranial Doppler ultrasonography should it be the first choice for persistent foramen ovale screening? Cardiovasc Ultrasound. 2014;12:16.","journal-title":"Cardiovasc Ultrasound"},{"key":"2565_CR6","doi-asserted-by":"publisher","first-page":"693","DOI":"10.1148\/radiol.2253011572","volume":"225","author":"WK Blersch","year":"2002","unstructured":"Blersch WK, Draganski BM, Holmer SR, et al. Transcranial duplex sonography in the detection of patent foramen ovale. Radiology. 2002;225:693\u20139.","journal-title":"Radiology"},{"key":"2565_CR7","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.acvd.2011.11.002","volume":"105","author":"NG Keenan","year":"2012","unstructured":"Keenan NG, Brochet E, Juliard JM, et al. Aortic root dilatation in young patients with cryptogenic stroke and patent foramen ovale. Arch Cardiovasc Dis. 2012;105:13\u20137.","journal-title":"Arch Cardiovasc Dis"},{"key":"2565_CR8","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.jns.2011.01.026","volume":"304","author":"J Aoki","year":"2011","unstructured":"Aoki J, Kimura K, Iguchi Y, et al. Higher LA pressure may prevent opening of patent foramen ovale in acute ischemic stroke patients with atrial fibrillation. J Neurol Sci. 2011;304:111\u20136.","journal-title":"J Neurol Sci"},{"key":"2565_CR9","doi-asserted-by":"publisher","first-page":"1696","DOI":"10.1136\/heartjnl-2016-310894","volume":"103","author":"P Andell","year":"2017","unstructured":"Andell P, Li X, Martinsson A, et al. Epidemiology of valvular heart disease in a Swedish nationwide hospital-based register study. Heart. 2017;103:1696\u2013703.","journal-title":"Heart"},{"key":"2565_CR10","doi-asserted-by":"publisher","first-page":"e1002404","DOI":"10.1371\/journal.pmed.1002404","volume":"14","author":"K Rahimi","year":"2017","unstructured":"Rahimi K, Mohseni H, Otto CM, et al. Elevated blood pressure and risk of mitral regurgitation: A longitudinal cohort study of 5.5 million United Kingdom adults. PLoS Med. 2017;14:e1002404.","journal-title":"PLoS Med"}],"container-title":["BMC Neurology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12883-022-02565-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12883-022-02565-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12883-022-02565-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,4]],"date-time":"2022-02-04T21:10:27Z","timestamp":1644009027000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcneurol.biomedcentral.com\/articles\/10.1186\/s12883-022-02565-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,4]]},"references-count":10,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["2565"],"URL":"https:\/\/doi.org\/10.1186\/s12883-022-02565-w","relation":{},"ISSN":["1471-2377"],"issn-type":[{"value":"1471-2377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,4]]},"assertion":[{"value":"22 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The institutional ethics committee of the Huashan Hospital, Fudan University approved this study and waived informed consent based on the study design. We confirm that all methods were performed in accordance with the relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"We declare that we have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"43"}}