{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T18:59:57Z","timestamp":1772218797757,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T00:00:00Z","timestamp":1645228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T00:00:00Z","timestamp":1645228800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Neurol"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Proper evaluation of ocular fundi is an integral part of neurological examination. Unfortunately, neurology residents are increasingly uncomfortable performing fundoscopy and interpreting findings because of diminishing skills and lack of experience. This became more prominent during the COVID-19 pandemic as fundoscopy requires proximity to the patient.<\/jats:p>\n                    <jats:p>With the recent dramatic improvement of smartphone cameras, fundus photography using the PanOptic Ophthalmoscope (Welch Allyn, Skaneateles Falls, NY) with a smartphone adapter offered an alternative to direct fundoscopic examination. We present the first experience with our own design of a universal smartphone adapter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This is a single-center case series, consecutive for a single user and certain presenting neurological symptoms, which is aimed to evaluate the feasibility and practicality of a new, universal PanOptic smartphone adapter. Presenting symptoms included headache, ocular symptoms, seizure, or encephalopathy. We used 3D modeling and printing techniques to create the adapter.<\/jats:p>\n                    <jats:p>We also developed a methodology of capturing stereoscopic images of the optic disc using a single smartphone camera, but the method was not systematically evaluated in this paper.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Here we present our initial experience of fundus video\/photography in patients, who presented with encephalopathy, headache, seizure, vision loss, and other ocular symptoms. Fundoscopic abnormalities were discovered in 11 out of 100 patients. Some were incidental findings and were unrelated to the presentation. In one case, fundoscopy played a critical role in establishing the correct diagnosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our custom-designed smartphone adapter allowed obtaining high-quality video and photo recordings using PanOptic Ophthalmoscope. The acquisition of high-quality photos enables a high-yield diagnostic tool and allows revisiting the image in the patient\u2019s chart. Improvement of smartphone cameras opens vast horizons for stereo-fundoscopy and 3D reconstruction of the ocular fundus without using sophisticated and costly equipment. Microscopic eye movements allow taking snapshots of two side-by-side photos for 3D reconstruction and stereoscopic image viewing, which is the next level of optic disc assessment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12883-022-02578-5","type":"journal-article","created":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T07:04:26Z","timestamp":1645254266000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Utility of video-fundoscopy and prospects of portable stereo-photography of the ocular fundus in neurological patients"],"prefix":"10.1186","volume":"22","author":[{"given":"Tigran","family":"Khachatryan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tahseen","family":"Mozaffar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lilit","family":"Mnatsakanyan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,2,19]]},"reference":[{"key":"2578_CR1","doi-asserted-by":"crossref","unstructured":"Golombievski E, Doerrler MW, Ruland SD, McCoyd MA, Biller J. Frequency of direct funduscopy upon initial encounters for patients with headaches, altered mental status, and visual changes: A pilot study. Front Neurol. 2015:10\u20132","DOI":"10.3389\/fneur.2015.00233"},{"key":"2578_CR2","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1212\/CPJ.0000000000000017","volume":"4","author":"K Shubhakaran","year":"2014","unstructured":"Shubhakaran K, Bidot S, Bruce BB, Newman NJ, Biousse V. Nonmydriatic retinal photography in the evaluation of acute neurologic conditions. Neurol Clin Pract. 2014;4:94\u20135.","journal-title":"Neurol Clin Pract."},{"key":"2578_CR3","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1097\/WNO.0000000000001038","volume":"40","author":"MW Ko","year":"2020","unstructured":"Ko MW, Busis NA. Tele-Neuro-Ophthalmology: Vision for 20\/20 and Beyond. J Neuroophthalmol. 2020;40:378\u201384.","journal-title":"J Neuroophthalmol."},{"key":"2578_CR4","doi-asserted-by":"crossref","unstructured":"Emanuele N, Klein R, Moritz T, Davis MD, Glander K, Anderson R, et al. Comparison of dilated fundus examinations with seven-field stereo fundus photographs in the Veterans Affairs Diabetes Trial. J Diabetes Complications. 2009;23:323\u20139","DOI":"10.1016\/j.jdiacomp.2008.02.010"},{"key":"2578_CR5","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1097\/IJG.0b013e318264be18","volume":"22","author":"K Asakawa","year":"2013","unstructured":"Asakawa K, Kato S, Shoji N, Morita T, Shimizu K. Evaluation of optic nerve head using a newly developed stereo retinal imaging technique by glaucoma specialist and non-expert-certified orthoptist. J Glaucoma. 2013;22:698\u2013706.","journal-title":"J Glaucoma."},{"key":"2578_CR6","doi-asserted-by":"crossref","unstructured":"Yokoyama Y, Tanito M, Nitta K, Katai M, Kitaoka Y, Omodaka K, et al. Stereoscopic analysis of optic nerve head parameters in primary open angle glaucoma: The glaucoma stereo analysis study. PLoS One. 2014;9:e99138.","DOI":"10.1371\/journal.pone.0099138"},{"key":"2578_CR7","doi-asserted-by":"crossref","unstructured":"Nakagawa T, Suzuki T, Hayashi Y, Mizukusa Y, Hatanaka Y, Ishida K, et al. Quantitative depth analysis of optic nerve head using stereo retinal fundus image pair. J Biomed Opt. 2008;13.","DOI":"10.1117\/1.3041711"},{"key":"2578_CR8","doi-asserted-by":"publisher","unstructured":"von Elm E, Altman DG, Egger M, Pocock SJ, G\u00f8tzsche PC, Vandenbroucke JP. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: Guidelines for reporting observational studies. Int J Surg. 2014;12:1495\u20139. https:\/\/doi.org\/10.1016\/j.ijsu.2014.07.013.","DOI":"10.1016\/j.ijsu.2014.07.013"},{"key":"2578_CR9","doi-asserted-by":"crossref","unstructured":"MacKay DD, Garza PS, Bruce BB, Newman NJ, Biousse V. The demise of direct ophthalmoscopy: A modern clinical challenge. Neurol Clin Pract. 2015;5:150\u20137","DOI":"10.1212\/CPJ.0000000000000115"},{"key":"2578_CR10","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1097\/NRL.0b013e318272f7d7","volume":"18","author":"MA P\u00e9rez","year":"2012","unstructured":"P\u00e9rez MA, Bruce BB, Newman NJ, Biousse V. The use of retinal photography in nonophthalmic settings and its potential for neurology. Neurologist. 2012;18:350\u20135.","journal-title":"Neurologist."},{"key":"2578_CR11","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1097\/NRL.0000000000000259","volume":"25","author":"NK Irani","year":"2020","unstructured":"Irani NK, Bidot S, Peragallo JH, Esper GJ, Newman NJ, Biousse V. Feasibility of a Nonmydriatic Ocular Fundus Camera in an Outpatient Neurology Clinic. Neurologist. 2020;25:19\u201323.","journal-title":"Neurologist."},{"key":"2578_CR12","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1001\/jamaneurol.2014.4053","volume":"72","author":"BB Bruce","year":"2015","unstructured":"Bruce BB, Biousse V, Newman NJ. Nonmydriatic ocular fundus photography in neurologic emergencies. JAMA Neurol. 2015;72:455\u20139.","journal-title":"JAMA Neurol."},{"key":"2578_CR13","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1055\/s-0035-1563572","volume":"35","author":"DD Mackay","year":"2015","unstructured":"Mackay DD, Garza PS. Ocular Fundus Photography as an Educational Tool. Semin Neurol. 2015;35:496\u2013505.","journal-title":"Semin Neurol."},{"key":"2578_CR14","doi-asserted-by":"publisher","first-page":"51","DOI":"10.3109\/01658107.2013.773451","volume":"37","author":"BB Bruce","year":"2013","unstructured":"Bruce BB, Newman NJ, P\u00e9rez MA, Biousse V. Non-mydriatic ocular fundus photography and telemedicine: Past, present, and future. Neuro-Ophthalmology. 2013;37:51\u20137.","journal-title":"Neuro-Ophthalmology."},{"key":"2578_CR15","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1212\/WNL.0000000000004868","volume":"90","author":"V Biousse","year":"2018","unstructured":"Biousse V, Bruce BB, Newman NJ. Ophthalmoscopy in the 21st century: The 2017 H.\u00a0Houston Merritt Lecture. Neurology. 2018;90:167\u201375.","journal-title":"Neurology."},{"key":"2578_CR16","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1111\/ane.13167","volume":"140","author":"M Alm","year":"2019","unstructured":"Alm M, Hautala N, Bloigu R, Huhtakangas J. Comparison of optic disc evaluation methods in neurology emergency patients. Acta Neurol Scand. 2019;140:449\u201351.","journal-title":"Acta Neurol Scand."},{"key":"2578_CR17","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1212\/WNL.0b013e31827f0f20","volume":"80","author":"P Thulasi","year":"2013","unstructured":"Thulasi P, Fraser CL, Biousse V, Wright DW, Newman NJ, Bruce BB. Nonmydriatic ocular fundus photography among headache patients in an emergency department. Neurology. 2013;80:432\u20137.","journal-title":"Neurology."},{"key":"2578_CR18","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1111\/1742-6723.13619","volume":"33","author":"HP Dunn","year":"2021","unstructured":"Dunn HP, Teo KZ, Smyth JWP, Weerasinghe LS, Costello J, Pampapathi P, et al. Using non-mydriatic fundusphotography to detect fundus pathology in Australian metropolitan emergency departments: A prospective prevalence and diagnostic accuracy study. EMA -Emerg Med Australas. 2021;33:302\u20139.","journal-title":"EMA -Emerg Med Australas."},{"key":"2578_CR19","doi-asserted-by":"crossref","unstructured":"Bruce BB, Lamirel C, Biousse V, Ward A, Heilpern KL, Newman NJ, et al. Feasibility of nonmydriatic ocular fundus photography in the emergency department: Phase i of the FOTO-ED study. Acad Emerg Med. 2011;18:928\u201333.","DOI":"10.1111\/j.1553-2712.2011.01147.x"},{"key":"2578_CR20","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1212\/WNL.0000000000005480","volume":"90","author":"S Zafar","year":"2018","unstructured":"Zafar S, Cardenas YM, Leishangthem L, Yaddanapudi S. Opinion and special articles: Amateur fundus photography with various new devices Our experience as neurology residents. Neurology. 2018;90:897\u2013901.","journal-title":"Neurology."},{"key":"2578_CR21","doi-asserted-by":"publisher","first-page":"331","DOI":"10.2147\/OPTH.S238897","volume":"14","author":"C Laurent","year":"2020","unstructured":"Laurent C, Hong SC, Cheyne KR, Ogbuehi KC. The detection of spontaneous venous pulsation with smartphone video ophthalmoscopy. Clin Ophthalmol. 2020;14:331\u20137.","journal-title":"Clin Ophthalmol."},{"key":"2578_CR22","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1097\/WCO.0000000000000637","volume":"32","author":"SJ Rodenbeck","year":"2019","unstructured":"Rodenbeck SJ, MacKay DD. Examiningthe ocular fundus in neurology. Curr Opin Neurol. 2019;32:105\u201310.","journal-title":"Curr Opin Neurol."},{"key":"2578_CR23","doi-asserted-by":"publisher","first-page":"1691","DOI":"10.1016\/j.cub.2013.07.007","volume":"23","author":"M Poletti","year":"2013","unstructured":"Poletti M, Listorti C, Rucci M. Microscopic eye movements compensate for nonhomogeneous vision within the fovea. Curr Biol. 2013;23:1691\u20135.","journal-title":"Curr Biol."},{"key":"2578_CR24","doi-asserted-by":"crossref","unstructured":"Dunn HP, Kang CJ, Marks S, Witherow JL, Dunn SM, Healey PR, et al. Perceived usefulness and ease of use of fundoscopy by medical students: a randomised crossover trial of six technologies (eFOCUS 1). BMC Med Educ. 2021;21:1\u20139.","DOI":"10.1186\/s12909-020-02469-8"},{"key":"2578_CR25","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1111\/ceo.13977","volume":"49","author":"HP Dunn","year":"2021","unstructured":"Dunn HP, Marks S, Teo KZ, Dunn SM, Healey PR, White AJ. eFOCUS 2: A randomised crossover trial of smartphone fundoscopy and direct ophthalmoscopy aiming to improve optic disc interpretation by medical students with e-learning support. Clin ExpOphthalmol. 2021;49:704\u201313. https:\/\/doi.org\/10.1111\/ceo.13977.","journal-title":"Clin ExpOphthalmol."}],"container-title":["BMC Neurology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12883-022-02578-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12883-022-02578-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12883-022-02578-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,19]],"date-time":"2022-02-19T07:05:03Z","timestamp":1645254303000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcneurol.biomedcentral.com\/articles\/10.1186\/s12883-022-02578-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,19]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["2578"],"URL":"https:\/\/doi.org\/10.1186\/s12883-022-02578-5","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-881801\/v1","asserted-by":"object"}]},"ISSN":["1471-2377"],"issn-type":[{"value":"1471-2377","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,19]]},"assertion":[{"value":"6 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 February 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All methods were performed in accordance with the relevant guidelines and regulations. According to Policy Number 16 outlined in \u201cStandard Operating Policies and Procedures\u201d of IRB Committee of the University of California, Irvine, \u201cQuality Improvement activities designed to continuously improve the quality or performance of a department or program or health care\u201d do not require prior IRB approval. Since the above data was collected as part of the resident quality improvement project, IRB approval was waived.Upon admission to the hospital all patients or their legal representatives signed general Terms and Conditions agreement, which reads: \u201cUse of medical information and specimens: I understand that my medical information, photographs and\/or video in any form may be used for other UC Irvine Health purposes, such as quality improvement, patient safety and education. I also understand that my medical information and tissue, fluids, cells and other specimens (collectively, \u201cSpecimens\u201d) that UC Irvine Health may collect during the course of my treatment and care may be used and shared with researchers.\u201d Signed terms and conditions forms for all patients are available upon reasonable request. Furthermore, fundoscopy is a part of neurological exam and does not require separate written consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"61"}}