{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T23:14:45Z","timestamp":1785798885449,"version":"3.56.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,9]],"date-time":"2021-04-09T00:00:00Z","timestamp":1617926400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,4,9]],"date-time":"2021-04-09T00:00:00Z","timestamp":1617926400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Showa University"},{"name":"All Japan Labor Welfare Foundation"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cancer"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Definitive diagnosis of peripheral pulmonary lesions (PPLs) depends on the histological analysis of the pleural biopsy sample. Ultrasound (US)-guided sampling is now standard practice in the clinical setting. However, determining a suitable needle size and sampling times to improve the efficacy and safety of the biopsy remains challenging. Here, we compared the efficacy between 16- and 18-gauge core biopsy needles in US-guided percutaneous transthoracic biopsy for PPLs on histological diagnosis and procedure-related complications.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>In total, 1169 patients (767 men, 402 women; mean age, 59.4\u2009\u00b1\u200913.2\u2009years) who received biopsy for PPLs between September 2011 and February 2019 were included. The propensity score matching (PSM) analysis was performed to adjust the baseline differences, and the rate of successful specimen assessment and complications were compared between the 16-gauge (249 patients) and 18-gauge (920 patients) groups. The number of pleural surfaces crossed (NOPSC) was defined as the number of times the visceral pleural surface was transgressed. Stratified analysis was performed based on NOPSC.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The overall success rate was 92.0% (1076\/1169). The overall complication rate was 9.6%, including pneumothorax, hemorrhage, and vasovagal reaction, which occurred in 2.5% (29\/1169), 6.6% (77\/1169), and 0.5% (6\/1169) of the patients, respectively. When NOPSC was 1 or\u2009&gt;\u20092, the success and complication rates in the 16-gauge group were comparable to those of the 18-gauge group (all\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&gt;\u20090.05). When the NOPSC was 2, the success rate in the 16-gauge group was significantly higher than that in the 18-gauge group (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.017), whereas the complication rate was comparable (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&gt;\u20090.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Higher success rate could be achieved using a 16-gauge than an 18-gauge core biopsy needle in the US-guided percutaneous transthoracic biopsy for PPLs when the NOPSC was 2. We recommend using 16-gauge needles with 2 times of needle passes in biopsy for PPLs in clinical practice.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12885-021-08126-7","type":"journal-article","created":{"date-parts":[[2021,4,9]],"date-time":"2021-04-09T07:03:31Z","timestamp":1617951811000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Propensity-score-matching analysis to compare efficacy and safety between 16-gauge and 18-gauge needle in ultrasound-guided biopsy for peripheral pulmonary lesions"],"prefix":"10.1186","volume":"21","author":[{"given":"Weijun","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jieyi","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yide","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiwei","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ninghui","family":"Lan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weizhen","family":"Cui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yinghui","family":"Ou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingjia","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,9]]},"reference":[{"key":"8126_CR1","doi-asserted-by":"publisher","unstructured":"Yamamoto N, Watanabe T, Yamada K, Nakai T, Suzumura T, Sakagami K, et al. Efficacy and safety of ultrasound (US) guided percutaneous needle biopsy for peripheral lung or pleural lesion: comparison with computed tomography (CT) guided needle biopsy. J Thorac Dis. 2019;11(3):936\u201343. https:\/\/doi.org\/10.21037\/jtd.2019.01.88.","DOI":"10.21037\/jtd.2019.01.88"},{"issue":"5","key":"8126_CR2","doi-asserted-by":"publisher","first-page":"e142S","DOI":"10.1378\/chest.12-2353","volume":"143","author":"MP Rivera","year":"2013","unstructured":"Rivera MP, Mehta AC, Wahidi MM. Establishing the diagnosis of lung cancer: diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines. Chest. 2013;143(5):e142S\u201365S. https:\/\/doi.org\/10.1378\/chest.12-2353.","journal-title":"Chest"},{"issue":"4","key":"8126_CR3","doi-asserted-by":"publisher","first-page":"226","DOI":"10.4103\/atm.ATM_110_19","volume":"14","author":"K Loverdos","year":"2019","unstructured":"Loverdos K, Fotiadis A, Kontogianni C, Iliopoulou M, Gaga M. Lung nodules: a comprehensive review on current approach and management. Ann Thorac Med. 2019;14(4):226\u201338. https:\/\/doi.org\/10.4103\/atm.ATM_110_19.","journal-title":"Ann Thorac Med"},{"issue":"15","key":"8126_CR4","doi-asserted-by":"publisher","first-page":"348","DOI":"10.21037\/atm.2019.03.59","volume":"7","author":"T Khan","year":"2019","unstructured":"Khan T, Usman Y, Abdo T, Chaudry F, Keddissi JI, Youness HA. Diagnosis and management of peripheral lung nodule. Ann Transl Med. 2019;7(15):348. https:\/\/doi.org\/10.21037\/atm.2019.03.59.","journal-title":"Ann Transl Med"},{"issue":"2","key":"8126_CR5","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.chest.2019.08.2187","volume":"157","author":"SPE Nishi","year":"2020","unstructured":"Nishi SPE, Zhou J, Okereke I, Kuo Y-F, Goodwin J. Use of imaging and diagnostic procedures after low-dose CT screening for lung cancer. Chest. 2020;157(2):427\u201334. https:\/\/doi.org\/10.1016\/j.chest.2019.08.2187.","journal-title":"Chest"},{"issue":"5","key":"8126_CR6","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1097\/01.mcp.0000239549.70573.d9","volume":"12","author":"DJ Riley","year":"2006","unstructured":"Riley DJ, Costanzo EJ. Surgical biopsy: its appropriateness in diagnosing interstitial lung disease. Curr Opin Pulm Med. 2006;12(5):331\u20136. https:\/\/doi.org\/10.1097\/01.mcp.0000239549.70573.d9.","journal-title":"Curr Opin Pulm Med"},{"issue":"4","key":"8126_CR7","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1378\/chest.127.4.1178","volume":"127","author":"JG Parambil","year":"2005","unstructured":"Parambil JG, Savci CD, Tazelaar HD, Ryu JH. Causes and presenting features of pulmonary infarctions in 43 cases identified by surgical lung biopsy. Chest. 2005;127(4):1178\u201383. https:\/\/doi.org\/10.1378\/chest.127.4.1178.","journal-title":"Chest"},{"key":"8126_CR8","doi-asserted-by":"publisher","unstructured":"Chavez C, Sasada S, Izumo T, Watanabe J, Katsurada M, Matsumoto Y, et al. Endobronchial ultrasound with a guide sheath for small malignant pulmonary nodules: a retrospective comparison between central and peripheral locations. J Thorac Dis. 2015;7(4):596\u2013602. https:\/\/doi.org\/10.3978\/j.issn.2072-1439.2015.03.04.","DOI":"10.3978\/j.issn.2072-1439.2015.03.04"},{"issue":"1","key":"8126_CR9","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1164\/rccm.200612-1866OC","volume":"176","author":"R Eberhardt","year":"2007","unstructured":"Eberhardt R, Anantham D, Ernst A, Feller-Kopman D, Herth F. Multimodality bronchoscopic diagnosis of peripheral lung lesions: a randomized controlled trial. Am J Respir Crit Care Med. 2007;176(1):36\u201341. https:\/\/doi.org\/10.1164\/rccm.200612-1866OC.","journal-title":"Am J Respir Crit Care Med"},{"key":"8126_CR10","doi-asserted-by":"publisher","unstructured":"Silvestri GA, Bevill BT, Huang J, Brooks M, Choi Y, Kennedy G, et al. An evaluation of diagnostic yield from bronchoscopy: the impact of clinical\/radiographic factors, procedure type, and degree of suspicion for cancer. Chest. 2020;157(6):1656\u201364. https:\/\/doi.org\/10.1016\/j.chest.2019.12.024.","DOI":"10.1016\/j.chest.2019.12.024"},{"key":"8126_CR11","doi-asserted-by":"publisher","unstructured":"Capalbo E, Peli M, Lovisatti M, Cosentino M, Mariani P, Berti E, et al. Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature. Radiol Med. 2014;119(8):572\u201394. https:\/\/doi.org\/10.1007\/s11547-013-0360-1.","DOI":"10.1007\/s11547-013-0360-1"},{"key":"8126_CR12","doi-asserted-by":"publisher","first-page":"960","DOI":"10.3389\/fphar.2019.00960","volume":"10","author":"Y Fu","year":"2019","unstructured":"Fu Y, Zhang YY, Cui LG, Tan S, Sun Y. Ultrasound-guided biopsy of pleural-based pulmonary lesions by injection of contrast-enhancing drugs. Front Pharmacol. 2019;10:960. https:\/\/doi.org\/10.3389\/fphar.2019.00960.","journal-title":"Front Pharmacol"},{"issue":"3","key":"8126_CR13","doi-asserted-by":"publisher","first-page":"1584","DOI":"10.1007\/s00330-019-06464-6","volume":"30","author":"YF Fu","year":"2020","unstructured":"Fu YF, Li GC, Xu QS, Shi YB, Wang C, Wang T. Computed tomography-guided lung biopsy: a randomized controlled trial of low-dose versus standard-dose protocol. Eur Radiol. 2020;30(3):1584\u201392. https:\/\/doi.org\/10.1007\/s00330-019-06464-6.","journal-title":"Eur Radiol"},{"issue":"1108","key":"8126_CR14","doi-asserted-by":"publisher","first-page":"20190866","DOI":"10.1259\/bjr.20190866","volume":"93","author":"YR Huo","year":"2020","unstructured":"Huo YR, Chan MV, Habib AR, Lui I, Ridley L. Pneumothorax rates in CT-guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors. Br J Radiol. 2020;93(1108):20190866.","journal-title":"Br J Radiol"},{"key":"8126_CR15","doi-asserted-by":"publisher","first-page":"79.e19","DOI":"10.1016\/j.crad.2019.10.003","volume":"75","author":"Y Wang","year":"2020","unstructured":"Wang Y, Xu Z, Huang H, Zhou X, Xian M. Application of quantitative contrast-enhanced ultrasound for evaluation and guiding biopsy of peripheral pulmonary lesions: a preliminary study. Clin Radiol. 2020;75:79.e19\u201324.","journal-title":"Clin Radiol"},{"key":"8126_CR16","doi-asserted-by":"publisher","unstructured":"Huang W, Chen L, Xu N, Wang L, Liu F, He S, et al. Diagnostic value and safety of color doppler ultrasound-guided transthoracic core needle biopsy of thoracic disease. Biosci Rep. 2019;39(6). https:\/\/doi.org\/10.1042\/BSR20190104.","DOI":"10.1042\/BSR20190104"},{"key":"8126_CR17","first-page":"e4802","volume":"11","author":"RA Khan","year":"2019","unstructured":"Khan RA, Kumar V, Taimur M, Khan MA, Arshad MM, Amjad MA. Diagnostic yield of ultrasound-guided trucut biopsy in diagnosis of peripheral lung malignancies. Cureus. 2019;11:e4802.","journal-title":"Cureus"},{"issue":"1","key":"8126_CR18","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1097\/RUQ.0000000000000435","volume":"36","author":"AF Tekin","year":"2020","unstructured":"Tekin AF, Turgut B, \u00d6nc\u00fc F. Should we perform transthoracic trucut lung biopsies of pleural-based lung masses under ultrasound guidance or computed tomography guidance? Ultrasound Q. 2020;36(1):49\u201353. https:\/\/doi.org\/10.1097\/RUQ.0000000000000435.","journal-title":"Ultrasound Q"},{"issue":"3","key":"8126_CR19","doi-asserted-by":"publisher","first-page":"W110","DOI":"10.2214\/AJR.17.18014","volume":"210","author":"MH Lee","year":"2018","unstructured":"Lee MH, Lubner MG, Hinshaw JL, Pickhardt PJ. Ultrasound guidance versus CT guidance for peripheral lung biopsy: performance according to lesion size and pleural contact. AJR Am J Roentgenol. 2018;210(3):W110\u2013w117. https:\/\/doi.org\/10.2214\/AJR.17.18014.","journal-title":"AJR Am J Roentgenol"},{"key":"8126_CR20","doi-asserted-by":"publisher","unstructured":"Kuban JD, Tam AL, Huang SY, Ensor JE, Philip AS, Chen GJ, et al. The effect of needle gauge on the risk of pneumothorax and chest tube placement after percutaneous computed tomographic (CT)-guided lung biopsy. Cardiovasc Intervent Radiol. 2015;38(6):1595\u2013602. https:\/\/doi.org\/10.1007\/s00270-015-1097-0.","DOI":"10.1007\/s00270-015-1097-0"},{"key":"8126_CR21","doi-asserted-by":"publisher","unstructured":"Kane LT, Fang T, Galetta MS, Goyal DKC, Nicholson KJ, Kepler CK, et al. Propensity score matching: a statistical method. Clin Spine Surg. 2020;33(3):120\u20132. https:\/\/doi.org\/10.1097\/BSD.0000000000000932.","DOI":"10.1097\/BSD.0000000000000932"},{"key":"8126_CR22","doi-asserted-by":"publisher","unstructured":"Manhire A, Charig M, Clelland C, Gleeson F, Miller R, Moss H, et al. Guidelines for radiologically guided lung biopsy. Thorax. 2003;58(11):920\u201336. https:\/\/doi.org\/10.1136\/thorax.58.11.920.","DOI":"10.1136\/thorax.58.11.920"},{"issue":"5","key":"8126_CR23","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.2214\/ajr.146.5.1049","volume":"146","author":"LM Perlmutt","year":"1986","unstructured":"Perlmutt LM, Braun SD, Newman GE, Oke EJ, Dunnick NR. Timing of chest film follow-up after transthoracic needle aspiration. AJR Am J Roentgenol. 1986;146(5):1049\u201350. https:\/\/doi.org\/10.2214\/ajr.146.5.1049.","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"8126_CR24","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1378\/chest.123.2.418","volume":"123","author":"PW Jones","year":"2003","unstructured":"Jones PW, Moyers JP, Rogers JT, Rodriguez RM, Lee YC, Light RW. Ultrasound-guided thoracentesis: is it a safer method? Chest. 2003;123(2):418\u201323. https:\/\/doi.org\/10.1378\/chest.123.2.418.","journal-title":"Chest"},{"key":"8126_CR25","doi-asserted-by":"publisher","unstructured":"Pereyra MF, San-Jos\u00e9 E, Ferreiro L, Golpe A, Ant\u00fanez J, Gonz\u00e1lez-Barcala F-J, et al. Role of blind closed pleural biopsy in the managment of pleural exudates. Can Respir J. 2013;20(5):362\u20136. https:\/\/doi.org\/10.1155\/2013\/731352.","DOI":"10.1155\/2013\/731352"},{"key":"8126_CR26","doi-asserted-by":"publisher","unstructured":"Christiansen IS, Clementsen PF, Bodtger U, Naur TMH, Pietersen PI, Laursen CB. Transthoracic ultrasound-guided biopsy in the hands of chest physicians - a stepwise approach. Eur Clin Respir J. 2019;6(1):1579632. https:\/\/doi.org\/10.1080\/20018525.2019.1579632.","DOI":"10.1080\/20018525.2019.1579632"},{"key":"8126_CR27","doi-asserted-by":"publisher","unstructured":"Guo YQ, Liao XH, Li ZX, Chen YY, Wang SD, Wang JH, et al. Ultrasound-guided percutaneous needle biopsy for peripheral pulmonary lesions: diagnostic accuracy and influencing factors. Ultrasound Med Biol. 2018;44(5):1003\u201311. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2018.01.016.","DOI":"10.1016\/j.ultrasmedbio.2018.01.016"},{"key":"8126_CR28","doi-asserted-by":"publisher","unstructured":"Jeon KN, Bae K, Park MJ, Choi HC, Shin HS, Shin S, et al. US-guided transthoracic biopsy of peripheral lung lesions: pleural contact length influences diagnostic yield. Acta Radiol. 2014;55(3):295\u2013301. https:\/\/doi.org\/10.1177\/0284185113494984.","DOI":"10.1177\/0284185113494984"},{"issue":"7","key":"8126_CR29","doi-asserted-by":"publisher","first-page":"1556","DOI":"10.1016\/j.ultrasmedbio.2018.03.003","volume":"44","author":"TG Lesser","year":"2018","unstructured":"Lesser TG, Petersen I, Polzing F, Wolfram F. One-lung flooding enables ultrasound-guided transthoracic needle biopsy of pulmonary nodules with high sensitivity. Ultrasound Med Biol. 2018;44(7):1556\u201362. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2018.03.003.","journal-title":"Ultrasound Med Biol"},{"key":"8126_CR30","doi-asserted-by":"publisher","unstructured":"Portela de Oliveira E, Souza CA, Inacio JR, Abdelzarek M, Dennie C, Gupta A, et al. Imaging-guided percutaneous biopsy of nodules \u22641 cm: study of diagnostic performance and risk factors associated with biopsy failure. J Thorac Imaging. 2020;35(2):123\u20138. https:\/\/doi.org\/10.1097\/RTI.0000000000000427.","DOI":"10.1097\/RTI.0000000000000427"}],"container-title":["BMC Cancer"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12885-021-08126-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12885-021-08126-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12885-021-08126-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,9]],"date-time":"2021-04-09T07:05:53Z","timestamp":1617951953000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccancer.biomedcentral.com\/articles\/10.1186\/s12885-021-08126-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,9]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["8126"],"URL":"https:\/\/doi.org\/10.1186\/s12885-021-08126-7","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-110059\/v1","asserted-by":"object"}]},"ISSN":["1471-2407"],"issn-type":[{"value":"1471-2407","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,9]]},"assertion":[{"value":"17 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board of First people\u2019s Hospital of Foshan, and informed consent was obtained from all human subjects. All procedures were performed in accordance with institutional and national standards on human experimentation, which complied with the Declaration of Helsinki of 1964 and its later amendments.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"390"}}