{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T13:18:39Z","timestamp":1788268719598,"version":"build-2803163510"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,8,22]],"date-time":"2024-08-22T00:00:00Z","timestamp":1724284800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,8,22]],"date-time":"2024-08-22T00:00:00Z","timestamp":1724284800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"National High Level Hospital Clinical Research Funding","award":["No. 2022-PUMCH-B-052"],"award-info":[{"award-number":["No. 2022-PUMCH-B-052"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Cancer"],"DOI":"10.1186\/s12885-024-12814-5","type":"journal-article","created":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T11:33:13Z","timestamp":1724412793000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A dosimetric comparison of brachytherapy sources for endometrial cancer: an electronic brachytherapy and an iridium-192 source with multichannel cylinders and a three-dimensional technique"],"prefix":"10.1186","volume":"24","author":[{"given":"Wenhui","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lang","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongnan","family":"Zhen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siqi","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhou","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fuquan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ke","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,22]]},"reference":[{"issue":"1","key":"12814_CR1","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1136\/ijgc-2020-002230","volume":"31","author":"N Concin","year":"2021","unstructured":"Concin N, Matias-Guiu X, Vergote I, Cibula D, Mirza MR, Marnitz S, et al. ESGO\/ESTRO\/ESP guidelines for the management of patients with endometrial carcinoma. Int J Gynecol cancer: Official J Int Gynecol Cancer Soc. 2021;31(1):12\u201339.","journal-title":"Int J Gynecol cancer: Official J Int Gynecol Cancer Soc"},{"issue":"4","key":"12814_CR2","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.brachy.2008.05.003","volume":"7","author":"A Dickler","year":"2008","unstructured":"Dickler A, Kirk MC, Coon A, Bernard D, Zusag T, Rotmensch J, et al. A dosimetric comparison of Xoft Axxent Electronic Brachytherapy and iridium-192 high-dose-rate brachytherapy in the treatment of endometrial cancer. Brachytherapy. 2008;7(4):351\u20134.","journal-title":"Brachytherapy"},{"issue":"1059","key":"12814_CR3","doi-asserted-by":"publisher","first-page":"20150449","DOI":"10.1259\/bjr.20150449","volume":"89","author":"PN Mobit","year":"2016","unstructured":"Mobit PN, Nguyen A, Packianathan S, He R, Yang CC. Dosimetric comparison of brachytherapy sources for high-dose-rate treatment of endometrial cancer: (192)ir, (60)Co and an electronic brachytherapy source. Br J Radiol. 2016;89(1059):20150449.","journal-title":"Br J Radiol"},{"key":"12814_CR4","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/1748-717X-5-67","volume":"5","author":"A Dickler","year":"2010","unstructured":"Dickler A, Puthawala MY, Thropay JP, Bhatnagar A, Schreiber G. Prospective multicenter trial utilizing electronic brachytherapy for the treatment of endometrial cancer. Radiation Oncol (London England). 2010;5:67.","journal-title":"Radiation Oncol (London England)"},{"key":"12814_CR5","doi-asserted-by":"publisher","first-page":"197","DOI":"10.2147\/OTT.S13593","volume":"3","author":"WC Dooley","year":"2010","unstructured":"Dooley WC, Thropay JP, Schreiber GJ, Puthawala MY, Lane SC, Wurzer JC, et al. Use of electronic brachytherapy to deliver postsurgical adjuvant radiation therapy for endometrial cancer: a retrospective multicenter study. OncoTargets Therapy. 2010;3:197\u2013203.","journal-title":"OncoTargets Therapy"},{"issue":"2","key":"12814_CR6","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.brachy.2012.04.003","volume":"12","author":"M Kamrava","year":"2013","unstructured":"Kamrava M, Chung MP, Demarco J, Kayode O, Park SJ, Borja L, et al. Electronic brachytherapy for postsurgical adjuvant vaginal cuff irradiation therapy in endometrial and cervical cancer: a retrospective study. Brachytherapy. 2013;12(2):141\u20137.","journal-title":"Brachytherapy"},{"issue":"4","key":"12814_CR7","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/j.ijrobp.2013.08.008","volume":"87","author":"SJ Park","year":"2013","unstructured":"Park SJ, Chung M, Demanes DJ, Banerjee R, Steinberg M, Kamrava M. Dosimetric comparison of 3-dimensional planning techniques using an intravaginal multichannel balloon applicator for high-dose-rate gynecologic brachytherapy. Int J Radiat Oncol Biol Phys. 2013;87(4):840\u20136.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"4","key":"12814_CR8","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.brachy.2016.03.002","volume":"15","author":"X Hou","year":"2016","unstructured":"Hou X, Liu A, Zhang F, Wong J, Chen YJ. Dosimetric advantages of using multichannel balloons compared to single-channel cylinders for high-dose-rate vaginal cuff brachytherapy. Brachytherapy. 2016;15(4):471\u20136.","journal-title":"Brachytherapy"},{"issue":"9717","key":"12814_CR9","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1016\/S0140-6736(09)62163-2","volume":"375","author":"RA Nout","year":"2010","unstructured":"Nout RA, Smit VT, Putter H, J\u00fcrgenliemk-Schulz IM, Jobsen JJ, Lutgens LC, et al. Vaginal brachytherapy versus pelvic external beam radiotherapy for patients with endometrial cancer of high-intermediate risk (PORTEC-2): an open-label, noninferiority, randomized trial. Lancet (London England). 2010;375(9717):816\u201323.","journal-title":"Lancet (London England)"},{"issue":"1","key":"12814_CR10","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1093\/annonc\/mdv484","volume":"27","author":"N Colombo","year":"2016","unstructured":"Colombo N, Creutzberg C, Amant F, Bosse T, Gonz\u00e1lez-Mart\u00edn A, Ledermann J, et al. ESMO-ESGO-ESTRO Consensus Conference on Endometrial Cancer: diagnosis, treatment and follow-up. Annals Oncology: Official J Eur Soc Med Oncol. 2016;27(1):16\u201341.","journal-title":"Annals Oncology: Official J Eur Soc Med Oncol"},{"issue":"9","key":"12814_CR11","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1038\/s41416-018-0310-8","volume":"119","author":"BG Wortman","year":"2018","unstructured":"Wortman BG, Creutzberg CL, Putter H, J\u00fcrgenliemk-Schulz IM, Jobsen JJ, Lutgens L, et al. Ten-year results of the PORTEC-2 trial for high-intermediate risk endometrial carcinoma: improving patient selection for adjuvant therapy. Br J Cancer. 2018;119(9):1067\u201374.","journal-title":"Br J Cancer"},{"issue":"5","key":"12814_CR12","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.brachy.2011.08.004","volume":"11","author":"P Rava","year":"2012","unstructured":"Rava P, Dvorak T, Markelewicz RJ Jr., Hiatt JR, Sternick ES, MacAusland SG, et al. A comparison of the biological effective dose of 50-kV electronic brachytherapy with (192)ir high-dose-rate brachytherapy for vaginal cuff irradiation. Brachytherapy. 2012;11(5):402\u20137.","journal-title":"Brachytherapy"},{"issue":"4","key":"12814_CR13","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1080\/09553008814552021","volume":"54","author":"M Hoshi","year":"1988","unstructured":"Hoshi M, Antoku S, Nakamura N, Russell WJ, Miller RC, Sawada S, et al. Soft X-ray dosimetry and RBE for survival of Chinese hamster V79 cells. Int J Radiat Biol. 1988;54(4):577\u201391.","journal-title":"Int J Radiat Biol"},{"issue":"1","key":"12814_CR14","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/s00411-003-0177-8","volume":"42","author":"D S\u0142onina","year":"2003","unstructured":"S\u0142onina D, Spekl K, Panteleeva A, Brankovic K, Hoinkis C, D\u00f6rr W. Induction of micronuclei in human fibroblasts and keratinocytes by 25\u00a0kV X-rays. Radiat Environ Biophys. 2003;42(1):55\u201361.","journal-title":"Radiat Environ Biophys"},{"issue":"2","key":"12814_CR15","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1088\/0031-9155\/44\/2\/002","volume":"44","author":"DJ Brenner","year":"1999","unstructured":"Brenner DJ, Leu CS, Beatty JF, Shefer RE. Clinical relative biological effectiveness of low-energy X-rays emitted by miniature X-ray devices. Phys Med Biol. 1999;44(2):323\u201333.","journal-title":"Phys Med Biol"},{"issue":"5","key":"12814_CR16","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1016\/j.brachy.2020.06.002","volume":"19","author":"GR Sarria","year":"2020","unstructured":"Sarria GR, Sperk E, Wenz F, Schneider F, Abo-Madyan Y, Giordano FA, et al. Adjuvant electronic brachytherapy for endometrial carcinoma: a 4-year outcomes report. Brachytherapy. 2020;19(5):635\u201341.","journal-title":"Brachytherapy"},{"issue":"1","key":"12814_CR17","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1017\/S1460396918000353","volume":"18","author":"S Lozares-Cordero","year":"2019","unstructured":"Lozares-Cordero S, Font-G\u00f3mez JA, Gand\u00eda-Mart\u00ednez A, M\u00e9ndez-Villam\u00f3n A, Villa-Gazulla D, Miranda-Burgos A, et al. Postoperative endometrial cancer treatments with electronic brachytherapy source. I Radiother Pract. 2019;18(1):16\u201320.","journal-title":"I Radiother Pract"},{"issue":"1\u20132","key":"12814_CR18","first-page":"Np","volume":"13","author":"Prescribing","year":"2013","unstructured":"Prescribing. Recording, and reporting brachytherapy for Cancer of the Cervix. J ICRU. 2013;13(1\u20132):Np.","journal-title":"J ICRU"},{"issue":"1","key":"12814_CR19","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.ijrobp.2021.09.027","volume":"112","author":"R Timmerman","year":"2022","unstructured":"Timmerman R. A story of Hypofractionation and the table on the Wall. Int J Radiat Oncol Biol Phys. 2022;112(1):4\u201321.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"1","key":"12814_CR20","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1186\/s12885-022-09343-4","volume":"22","author":"W Wang","year":"2022","unstructured":"Wang W, Wang T, Liu Z, He J, Sun X, Zhong W, et al. Overview of adjuvant radiotherapy on survival, failure pattern and toxicity in stage I to II endometrial carcinoma: a long-term multi-institutional analysis in China. BMC Cancer. 2022;22(1):266.","journal-title":"BMC Cancer"},{"issue":"3","key":"12814_CR21","doi-asserted-by":"publisher","first-page":"253","DOI":"10.5114\/jcb.2022.117729","volume":"14","author":"G Kaur","year":"2022","unstructured":"Kaur G, Garg P, Srivastava AK, Gaur G, Sheetal, Grover R, et al. Dosimetric and radiobiological evaluation of treatment plan for cervical cancer high-dose-rate intracavitary brachytherapy. J Contemp Brachytherapy. 2022;14(3):253\u20139.","journal-title":"J Contemp Brachytherapy"},{"issue":"4","key":"12814_CR22","doi-asserted-by":"publisher","first-page":"207","DOI":"10.4103\/0971-6203.103606","volume":"37","author":"T Kataria","year":"2012","unstructured":"Kataria T, Sharma K, Subramani V, Karrthick KP, Bisht SS. Homogeneity Index: an objective tool for assessment of conformal radiation treatments. J Med Phys. 2012;37(4):207\u201313.","journal-title":"J Med Phys"},{"issue":"3","key":"12814_CR23","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.brachy.2018.10.006","volume":"18","author":"MC Tom","year":"2019","unstructured":"Tom MC, Hepel JT, Patel R, Kamrava M, Badiyan SN, Cohen GN, et al. The American Brachytherapy Society consensus statement for electronic brachytherapy. Brachytherapy. 2019;18(3):292\u20138.","journal-title":"Brachytherapy"}],"container-title":["BMC Cancer"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12885-024-12814-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12885-024-12814-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12885-024-12814-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,23]],"date-time":"2024-08-23T11:36:23Z","timestamp":1724412983000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmccancer.biomedcentral.com\/articles\/10.1186\/s12885-024-12814-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,22]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["12814"],"URL":"https:\/\/doi.org\/10.1186\/s12885-024-12814-5","relation":{},"ISSN":["1471-2407"],"issn-type":[{"value":"1471-2407","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,22]]},"assertion":[{"value":"15 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Institutional Review Board of Peking Union Medical College Hospital (N0. I-23PJ1425). As a retrospective and observational study, this study received a waiver for informed consent from the ethics committee of Peking Union Medical College Hospital.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"1041"}}