{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T06:57:04Z","timestamp":1793429824387,"version":"4.5.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,4,24]],"date-time":"2018-04-24T00:00:00Z","timestamp":1524528000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s12886-018-0758-6","type":"journal-article","created":{"date-parts":[[2018,4,24]],"date-time":"2018-04-24T11:23:18Z","timestamp":1524568998000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Comparison of two techniques for toric intraocular lens implantation: hydroimplantation versus ophthalmic viscosurgical devices"],"prefix":"10.1186","volume":"18","author":[{"given":"Yueqin","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qian","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunyan","family":"Xue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenping","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,4,24]]},"reference":[{"key":"758_CR1","first-page":"719","volume":"8","author":"P Leon","year":"2015","unstructured":"Leon P, Pastore MR, Zanei A, Umari I, Messai M, Negro C, et al. Correction of low corneal astigmatism in cataract surgery. Int J Ophthalmol. 2015;8:719\u201324.","journal-title":"Int J Ophthalmol"},{"key":"758_CR2","doi-asserted-by":"publisher","first-page":"513","DOI":"10.3928\/1081597X-20150727-01","volume":"31","author":"A Bachernegg","year":"2015","unstructured":"Bachernegg A, Ruckl T, Strohmaier C, Jell G, Grabner G, Dexl AK. Vector analysis, rotational stability, and visual outcome after implantation of a new aspheric Toric IOL. J Refract Surg. 2015;31:513\u201320.","journal-title":"J Refract Surg"},{"key":"758_CR3","doi-asserted-by":"publisher","first-page":"358","DOI":"10.3928\/1081597X-20150521-01","volume":"31","author":"H Bissen-Miyajima","year":"2015","unstructured":"Bissen-Miyajima H, Negishi K, Hieda O, Kinoshita S. Microincision hydrophobic acrylic aspheric Toric intraocular Lens for astigmatism and cataract correction. J Refract Surg. 2015;31:358\u201364.","journal-title":"J Refract Surg"},{"key":"758_CR4","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/j.sjopt.2015.07.002","volume":"29","author":"JH Farooqui","year":"2015","unstructured":"Farooqui JH, Koul A, Dutta R, Shroff NM. Management of moderate and severe corneal astigmatism with AcrySof(R) toric intraocular lens implantation - our experience. Saudi J Ophthalmol. 2015;29:264\u20139.","journal-title":"Saudi J Ophthalmol"},{"key":"758_CR5","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.ajo.2015.06.007","volume":"160","author":"R Nagpal","year":"2015","unstructured":"Nagpal R, Sharma N, Vasavada V, Maharana PK, Titiyal JS, Sinha R, et al. Toric intraocular lens versus monofocal intraocular lens implantation and photorefractive keratectomy: a randomized controlled trial. Am J Ophthalmol. 2015;160:479\u201386. e2","journal-title":"Am J Ophthalmol"},{"key":"758_CR6","doi-asserted-by":"publisher","first-page":"476","DOI":"10.3928\/1081597X-20130617-06","volume":"29","author":"L Toto","year":"2013","unstructured":"Toto L, Vecchiarino L, D'Ugo E, Cardone D, Mastropasqua A, Mastropasqua R, et al. Astigmatism correction with toric IOL: analysis of visual performance, position, and wavefront error. J Refract Surg. 2013;29:476\u201383.","journal-title":"J Refract Surg"},{"key":"758_CR7","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.jcrs.2009.10.042","volume":"36","author":"H Tak","year":"2010","unstructured":"Tak H. Hydroimplantation: foldable intraocular lens implantation without an ophthalmic viscosurgical device. J Cataract Refract Surg. 2010;36:377\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"758_CR8","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/j.jcrs.2010.06.015","volume":"36","author":"P Bohm","year":"2010","unstructured":"Bohm P. Usefulness of hydroimplantation technique for foldable IOL implantation. J Cataract Refract Surg. 2010;36:1623\u20134.","journal-title":"J Cataract Refract Surg"},{"key":"758_CR9","doi-asserted-by":"publisher","first-page":"1801","DOI":"10.1016\/j.jcrs.2010.07.012","volume":"36","author":"RJ Mackool","year":"2010","unstructured":"Mackool RJ. Hydroimplantation. J cataract refract Surg. 2010;36:1801. author reply 1801","journal-title":"J cataract refract Surg"},{"issue":"6","key":"758_CR10","doi-asserted-by":"publisher","first-page":"850","DOI":"10.5301\/ejo.5000491","volume":"24","author":"P Studeny","year":"2014","unstructured":"Studeny P, Hyndrak M, Kacerovsky M, Mojzis P, Sivekova D, Kuchynka P. Safety of hydroimplantation: a foldable intraocular lens implantation without the use of an ophthalmic viscosurgical device. Eur J Ophthalmol. 2014;24(6):850.","journal-title":"Eur J Ophthalmol"},{"key":"758_CR11","doi-asserted-by":"publisher","first-page":"15","DOI":"10.3341\/kjo.2011.25.1.15","volume":"25","author":"HY Lee","year":"2011","unstructured":"Lee HY, Choy YJ, Park JS. Comparison of OVD and BSS for maintaining the anterior chamber during IOL implantation. Korean J Ophthalmol. 2011;25:15\u201321.","journal-title":"Korean J Ophthalmol"},{"key":"758_CR12","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.jcrs.2013.05.018","volume":"39","author":"G Carifi","year":"2013","unstructured":"Carifi G, Pitsas C, Zygoura V, Kopsachilis N. Hydroimplantation of intraocular lenses. J Cataract Refract Surg. 2013;39:1281\u20132.","journal-title":"J Cataract Refract Surg"},{"key":"758_CR13","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1016\/j.jcrs.2013.02.001","volume":"39","author":"H Bayramlar","year":"2013","unstructured":"Bayramlar H, Dag Y, Sadigov F. Comments on corneal astigmatic marking methods. J Cataract Refract Surg. 2013;39:966.","journal-title":"J Cataract Refract Surg"},{"key":"758_CR14","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/1471-2415-8-8","volume":"8","author":"B Zuberbuhler","year":"2008","unstructured":"Zuberbuhler B, Signer T, Gale R, Haefliger E. Rotational stability of the AcrySof SA60TT toric intraocular lenses: a cohort study. BMC Ophthalmol. 2008;8:8.","journal-title":"BMC Ophthalmol"},{"key":"758_CR15","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/S0886-3350(00)00797-5","volume":"27","author":"LN Thibos","year":"2001","unstructured":"Thibos LN, Horner D. Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg. 2001;27:80\u20135.","journal-title":"J Cataract Refract Surg"},{"key":"758_CR16","doi-asserted-by":"publisher","first-page":"711","DOI":"10.1016\/S0886-3350(00)00697-0","volume":"27","author":"BJ Shingleton","year":"2001","unstructured":"Shingleton BJ, Mitrev PV. Anterior chamber maintainer versus viscoelastic material for intraocular lens implantation: case-control study. J Cataract Refract Surg. 2001;27:711\u20134.","journal-title":"J Cataract Refract Surg"},{"key":"758_CR17","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ophtha.2014.06.027","volume":"122","author":"KL Waltz","year":"2015","unstructured":"Waltz KL, Featherstone K, Tsai L, Trentacost D. Clinical outcomes of TECNIS toric intraocular lens implantation after cataract removal in patients with corneal astigmatism. Ophthalmology. 2015;122:39\u201347.","journal-title":"Ophthalmology"},{"key":"758_CR18","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.ajo.2013.09.032","volume":"157","author":"N Hirnschall","year":"2014","unstructured":"Hirnschall N, Maedel S, Weber M, Findl O. Rotational stability of a single-piece toric acrylic intraocular lens: a pilot study. Am J Ophthalmol. 2014;157:405\u201311.","journal-title":"Am J Ophthalmol"},{"key":"758_CR19","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1136\/bjophthalmol-2012-302455","volume":"97","author":"JY Lee","year":"2013","unstructured":"Lee JY, Kang KM, Shin JP, Kim IT, Kim SY, Park DH. Two-year results of AcrySof toric intraocular lens implantation in patients with combined microincision vitrectomy surgery and phacoemulsification. Br J Ophthalmol. 2013;97:444\u20139.","journal-title":"Br J Ophthalmol"},{"key":"758_CR20","doi-asserted-by":"publisher","first-page":"551","DOI":"10.3928\/1081597X-20120703-03","volume":"28","author":"TB Ferreira","year":"2012","unstructured":"Ferreira TB, Almeida A. Comparison of the visual outcomes and OPD-scan results of AMO Tecnis toric and Alcon Acrysof IQ toric intraocular lenses. J Refract Surg. 2012;28:551\u20135.","journal-title":"J Refract Surg"},{"key":"758_CR21","doi-asserted-by":"crossref","first-page":"182","DOI":"10.3928\/1542-8877-20030501-03","volume":"34","author":"A Grinbaum","year":"2003","unstructured":"Grinbaum A, Blumenthal M, Assia E. Comparison of intraocular pressure profiles during cataract surgery by phacoemulsification and extracapsular cataract extraction. Ophthalmic Surg Lasers Imaging. 2003;34:182\u20136.","journal-title":"Ophthalmic Surg Lasers Imaging"},{"key":"758_CR22","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1038\/eye.2014.162","volume":"28","author":"S Khokhar","year":"2014","unstructured":"Khokhar S, Sharma R, Patil B, Aron N, Gupta S. Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study. Eye (Lond). 2014;28:1174\u20138.","journal-title":"Eye (Lond)"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-018-0758-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-018-0758-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-018-0758-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,23]],"date-time":"2019-04-23T23:07:41Z","timestamp":1556060861000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-018-0758-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,24]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["758"],"URL":"https:\/\/doi.org\/10.1186\/s12886-018-0758-6","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,24]]},"assertion":[{"value":"3 November 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 April 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 April 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was approved by the Ethical Committee of Jinling Hospital. All patients were fully informed of the details and possible risks of the procedure, and written informed consents were obtained from all the patients. Described research adhered to the tenets of the Declaration of Helsinki.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare that they have no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"109"}}