{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:38:43Z","timestamp":1792787923118,"version":"4.5.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,7,18]],"date-time":"2018-07-18T00:00:00Z","timestamp":1531872000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Bumsuk Academic Research Fund","award":["2017"],"award-info":[{"award-number":["2017"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s12886-018-0840-0","type":"journal-article","created":{"date-parts":[[2018,7,18]],"date-time":"2018-07-18T13:31:14Z","timestamp":1531920674000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Comparative evaluation of refractive outcomes after implantation of two types of intraocular lenses with different diopter intervals (0.25 diopter versus 0.50 diopter)"],"prefix":"10.1186","volume":"18","author":[{"given":"Minjung","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9475-4409","authenticated-orcid":false,"given":"Youngsub","family":"Eom","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong Suk","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyo Myung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,7,18]]},"reference":[{"issue":"5","key":"840_CR1","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol. 2007;85(5):472\u201385.","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"840_CR2","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1111\/j.1600-0420.2006.00774.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen T. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster. Acta Ophthalmol. 2007;85(1):84\u20137.","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"840_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0886-3350(02)02011-4","volume":"29","author":"N Mamalis","year":"2003","unstructured":"Mamalis N. Intraocular lens power accuracy: how are we doing? J Cataract Refract Surg. 2003;29(1):1\u20133.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"840_CR4","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","volume":"34","author":"S Norrby","year":"2008","unstructured":"Norrby S. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 2008;34(3):368\u201376.","journal-title":"J Cataract Refract Surg"},{"key":"840_CR5","unstructured":"International Organization for Standardization. Ophthalmic implants--intraocular lenses--part 2: Optical properties and test methods: (International Organization for Standardization). 2014. p. ISO 11979\u20132. \n                    https:\/\/www.iso.org\/standard\/55682.html\n                    \n                  ."},{"issue":"2","key":"840_CR6","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/S0886-3350(13)80917-0","volume":"18","author":"T Olsen","year":"1992","unstructured":"Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992;18(2):125\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"840_CR7","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1016\/S0886-3350(96)80204-5","volume":"22","author":"NS Norrby","year":"1996","unstructured":"Norrby NS, Grossman LW, Geraghty EP, Kreiner CF, Mihori M, Patel AS, Portney V, Silberman DM. Accuracy in determining intraocular lens dioptric power assessed by interlaboratory tests. J Cataract Refract Surg. 1996;22(7):983\u201393.","journal-title":"J Cataract Refract Surg"},{"key":"840_CR8","unstructured":"Lenstec. Products: Internationals: Softec series IOLs: Softec HD: Resources: Brochures: PKB07 Rev 10 Softec HD Flyer.pdf. Available at \n                    https:\/\/www.lenstec.com\/resources2.html\n                    \n                  . Accessed 11 Dec 2017."},{"issue":"3","key":"840_CR9","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1016\/j.ophtha.2012.09.008","volume":"120","author":"Y Eom","year":"2013","unstructured":"Eom Y, Kang SY, Song JS, Kim HM. Use of corneal power-specific constants to improve the accuracy of the SRK\/T formula. Ophthalmology. 2013;120(3):477\u201381.","journal-title":"Ophthalmology"},{"issue":"8","key":"840_CR10","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1016\/j.jcrs.2014.12.053","volume":"41","author":"Y Eom","year":"2015","unstructured":"Eom Y, Song JS, Kim YY, Kim HM. Comparison of SRK\/T and Haigis formulas for predicting corneal astigmatism correction with toric intraocular lenses. J Cataract Refract Surg. 2015;41(8):1650\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"840_CR11","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1016\/j.ajo.2013.12.017","volume":"157","author":"Y Eom","year":"2014","unstructured":"Eom Y, Kang SY, Song JS, Kim YY, Kim HM. Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes. Am J Ophthalmol. 2014;157(4):818\u201324. e812.","journal-title":"Am J Ophthalmol"},{"key":"840_CR12","unstructured":"East Valley Ophthalmology (\n                    doctor-hill.com\n                    \n                  ) Physician Downloads: Haigis Formula Optimization \u2013 Haigis-300.xls. Available at \n                    https:\/\/doctor-hill.com\/iol-power-calculations\/resources-downloads\n                    \n                  . Accessed 11 July 2018."},{"issue":"4","key":"840_CR13","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.clae.2011.04.003","volume":"34","author":"DC Brown","year":"2011","unstructured":"Brown DC, Gills JP, Trattler WB, Newsom TH, Weinstock RJ, Sanders DR. Prospective multicenter trial assessing effectiveness, refractive predictability and safety of a new aberration free, bi-aspheric intraocular lens. Cont Lens Anterior Eye. 2011;34(4):188\u201392.","journal-title":"Cont Lens Anterior Eye"},{"issue":"1","key":"840_CR14","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1186\/s12886-017-0664-3","volume":"17","author":"Y Choi","year":"2017","unstructured":"Choi Y, Eom Y, Song JS, Kim HM. Influence of corneal power on intraocular lens power of the second eye in the SRK\/T formula in bilateral cataract surgery. BMC Ophthalmol. 2017;17(1):261.","journal-title":"BMC Ophthalmol"},{"issue":"4","key":"840_CR15","doi-asserted-by":"publisher","first-page":"179","DOI":"10.3109\/03091902.2014.899401","volume":"38","author":"Y Li","year":"2014","unstructured":"Li Y, Bao FJ. Interocular symmetry analysis of bilateral eyes. J Med Eng Technol. 2014;38(4):179\u201387.","journal-title":"J Med Eng Technol."},{"issue":"1","key":"840_CR16","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/S0886-3350(03)00556-X","volume":"30","author":"V Petternel","year":"2004","unstructured":"Petternel V, Menapace R, Findl O, Kiss B, Wirtitsch M, Rainer G, Drexler W. Effect of optic edge design and haptic angulation on postoperative intraocular lens position change. J Cataract Refract Surg. 2004;30(1):52\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"840_CR17","doi-asserted-by":"publisher","first-page":"1528","DOI":"10.1016\/j.jcrs.2013.04.040","volume":"39","author":"Y Eom","year":"2013","unstructured":"Eom Y, Kang SY, Song JS, Kim HM. Comparison of the actual amount of axial movement of 3 aspheric intraocular lenses using anterior segment optical coherence tomography. J Cataract Refract Surg. 2013;39(10):1528\u201333.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"840_CR18","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1016\/S0886-3350(98)80330-1","volume":"24","author":"SJ Lim","year":"1998","unstructured":"Lim SJ, Kang SJ, Kim HB, Apple DJ. Ideal size of an intraocular lens for capsular bag fixation. J Cataract Refract Surg. 1998;24(3):397\u2013402.","journal-title":"J Cataract Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-018-0840-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-018-0840-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-018-0840-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,17]],"date-time":"2019-07-17T19:12:10Z","timestamp":1563390730000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-018-0840-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,18]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["840"],"URL":"https:\/\/doi.org\/10.1186\/s12886-018-0840-0","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,18]]},"assertion":[{"value":"16 April 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This prospective study was approved by the Institutional Review Board of Korea University Ansan Hospital, Gyeonggi-do, South Korea (\n                      Reference number:\n                      2016AS0020) and was registered as a clinical trial at\n                      \n                      (\n                      Identification number:\n                      KCT0002192). All patients provided signed informed consent to participate in a clinical research study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable (no identifying patient data).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Youngsub Eom is a member of the editorial board of this journal.The authors have no financial or proprietary interest in any product, method, or material described herein.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"176"}}