{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T14:43:57Z","timestamp":1783694637644,"version":"3.55.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,2,18]],"date-time":"2019-02-18T00:00:00Z","timestamp":1550448000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Ministry of Health & Welfare, Republic of Korea","award":["HI17C0659"],"award-info":[{"award-number":["HI17C0659"]}]},{"DOI":"10.13039\/501100002701","name":"Ministry of Education","doi-asserted-by":"publisher","award":["2017R1A1A2A10000681"],"award-info":[{"award-number":["2017R1A1A2A10000681"]}],"id":[{"id":"10.13039\/501100002701","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12886-019-1064-7","type":"journal-article","created":{"date-parts":[[2019,2,18]],"date-time":"2019-02-18T08:02:56Z","timestamp":1550476976000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["A novel method for quantifying the biomechanical parameters of orbital soft tissue using a corneal dynamic scheimpflug analyser: a retrospective study"],"prefix":"10.1186","volume":"19","author":[{"given":"Ho Sik","family":"Hwang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eun Chul","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Man Soo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suk-Woo","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,18]]},"reference":[{"key":"1064_CR1","unstructured":"Asaoka R, Nakakura S, Tabuchi H, Murata H, Nakao Y, Ihara N, Rimayanti U, Aihara M, Kiuchi Y: The relationship between Corvis ST tonometry measured corneal parameters and intraocular pressure Corneal Thickness and Corneal Curvature, PLoS One 2015, 10(10):e0140385. doi: 10.0141371\/journal.pone.0140385. eCollection 0142015."},{"issue":"1","key":"1064_CR2","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1097\/OPX.1090b1013e318279eb318287","volume":"90","author":"Y Hon","year":"2013","unstructured":"Hon Y, Lam AK. Corneal deformation measurement using Scheimpflug noncontact tonometry. Optom Vis Sci. 2013;90(1):e1\u20138. \n                    https:\/\/doi.org\/10.1097\/OPX.1090b1013e318279eb318287\n                    \n                  .","journal-title":"Optom Vis Sci"},{"issue":"1","key":"1064_CR3","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1167\/iovs.1112\u201310984","volume":"54","author":"J Hong","year":"2013","unstructured":"Hong J, Xu J, Wei A, Deng SX, Cui X, Yu X, Sun X. A new tonometer--the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest Ophthalmol Vis Sci. 2013;54(1):659\u201365. \n                    https:\/\/doi.org\/10.1167\/iovs.1112-10984\n                    \n                  .","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"1064_CR4","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1016\/j.ajo.2013.12.024","volume":"157","author":"T Huseynova","year":"2014","unstructured":"Huseynova T, GOt W, Roberts C, Krueger RR, Tomita M. Corneal biomechanics as a function of intraocular pressure and pachymetry by dynamic infrared signal and Scheimpflug imaging analysis in normal eyes. Am J Ophthalmol. 2014;157(4):885\u201393.","journal-title":"Am J Ophthalmol"},{"issue":"8","key":"1064_CR5","doi-asserted-by":"publisher","first-page":"558","DOI":"10.3928\/1081597X-20130719-20130706","volume":"29","author":"G Nemeth","year":"2013","unstructured":"Nemeth G, Hassan Z, Csutak A, Szalai E, Berta A, Modis L Jr. Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas. J Refract Surg. 2013;29(8):558\u201363. \n                    https:\/\/doi.org\/10.3928\/1081597X-20130719-20130706\n                    \n                  .","journal-title":"J Refract Surg"},{"issue":"6","key":"1064_CR6","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1016\/j.jcrs.2014.1003.1021","volume":"40","author":"DP Pinero","year":"2014","unstructured":"Pinero DP, Alcon N. In vivo characterization of corneal biomechanics. J Cataract Refract Surg. 2014;40(6):870\u201387. \n                    https:\/\/doi.org\/10.1016\/j.jcrs.2014.1003.1021\n                    \n                  .","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"1064_CR7","doi-asserted-by":"publisher","first-page":"3651","DOI":"10.1167\/iovs.3613-13715","volume":"55","author":"NQ Ali","year":"2014","unstructured":"Ali NQ, Patel DV, McGhee CN. Biomechanical responses of healthy and keratoconic corneas measured using a noncontact scheimpflug-based tonometer. Invest Ophthalmol Vis Sci. 2014;55(6):3651\u20139. \n                    https:\/\/doi.org\/10.1167\/iovs.3613-13715\n                    \n                  .","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"6","key":"1064_CR8","doi-asserted-by":"publisher","first-page":"408","DOI":"10.3928\/1081597X-20140513-20140502","volume":"30","author":"S Bak-Nielsen","year":"2014","unstructured":"Bak-Nielsen S, Pedersen IB, Ivarsen A, Hjortdal J. Dynamic Scheimpflug-based assessment of keratoconus and the effects of corneal cross-linking. J Refract Surg. 2014;30(6):408\u201314. \n                    https:\/\/doi.org\/10.3928\/1081597X-20140513-20140502\n                    \n                  .","journal-title":"J Refract Surg"},{"issue":"11","key":"1064_CR9","doi-asserted-by":"publisher","first-page":"1404","DOI":"10.1097\/ICO.0000000000000598","volume":"34","author":"J Steinberg","year":"2015","unstructured":"Steinberg J, Katz T, Lucke K, Frings A, Druchkiv V, Linke SJ. Screening for keratoconus with new dynamic biomechanical in vivo Scheimpflug analyses. Cornea. 2015;34(11):1404\u201312. \n                    https:\/\/doi.org\/10.1097\/ICO.0000000000000598\n                    \n                  .","journal-title":"Cornea"},{"key":"1064_CR10","doi-asserted-by":"publisher","unstructured":"Tian L, Ko MW, Wang LK, Zhang JY, Li TJ, Huang YF, Zheng YP: Assessment of ocular biomechanics using dynamic ultra high-speed Scheimpflug imaging in keratoconic and normal eyes. J Refract Surg 2014, 30(11):785\u2013791. doi: \n                    https:\/\/doi.org\/10.3928\/1081597X-20140930-20140901\n                    \n                  . Epub 20142014 Oct 20140937.","DOI":"10.3928\/1081597X-20140930-20140901"},{"key":"1064_CR11","unstructured":"Chen X, Stojanovic A, Hua Y, Eidet JR, Hu D, Wang J, Utheim TP: Reliability of corneal dynamic scheimpflug analyser measurements in virgin and post-PRK eyes. PLoS One 2014, 9(10):e109577. doi: 10.101371\/journal.pone.0109577. eCollection 0102014."},{"key":"1064_CR12","doi-asserted-by":"publisher","unstructured":"Pedersen IB, Bak-Nielsen S, Vestergaard AH, Ivarsen A, Hjortdal J: Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry. Graefes Arch Clin Exp Ophthalmol 2014, 252(8):1329\u20131335. doi: 13\n                    https:\/\/doi.org\/10.1007\/s00417-00014-02667-00416\n                    \n                  . Epub 02014 May 00427.","DOI":"10.1007\/s00417-00014-02667-00416"},{"key":"1064_CR13","first-page":"1","volume":"10","author":"SM Sefat","year":"2015","unstructured":"Sefat SM, Wiltfang R, Bechmann M, Mayer WJ, Kampik A, Kook D. Evaluation of changes in human corneas after femtosecond laser-assisted LASIK and small-incision Lenticule extraction (SMILE) using non-contact tonometry and ultra-high-speed camera (Corvis ST). Curr Eye Res. 2015;10:1\u20136.","journal-title":"Curr Eye Res"},{"issue":"5","key":"1064_CR14","doi-asserted-by":"publisher","first-page":"310","DOI":"10.3928\/1081597X-20140422-01","volume":"30","author":"Y Shen","year":"2014","unstructured":"Shen Y, Chen Z, Knorz MC, Li M, Zhao J, Zhou X. Comparison of corneal deformation parameters after SMILE, LASEK, and femtosecond laser-assisted LASIK. J Refract Surg. 2014;30(5):310\u20138.","journal-title":"J Refract Surg"},{"key":"1064_CR15","unstructured":"Shen Y, Zhao J, Yao P, Miao H, Niu L, Wang X, Zhou X: Changes in corneal deformation parameters after lenticule creation and extraction during small incision lenticule extraction (SMILE) procedure. PLoS One 2014, 9(8):e103893. doi: 10.101371\/journal.pone.0103893. eCollection 0102014."},{"key":"1064_CR16","first-page":"16","volume":"16","author":"R Lee","year":"2015","unstructured":"Lee R, Chang RT, Wong IY, Lai JS, Lee JW, Singh K. Novel parameter of corneal biomechanics that differentiate Normals from Glaucoma. J Glaucoma. 2015;16:16.","journal-title":"J Glaucoma"},{"key":"1064_CR17","doi-asserted-by":"publisher","unstructured":"Reznicek L, Muth D, Kampik A, Neubauer AS, Hirneiss C: Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma. Br J Ophthalmol 2013, 97(11):1410\u20131414. doi: \n                    https:\/\/doi.org\/10.1136\/bjophthalmol-2013-303400\n                    \n                  . Epub 302013 Aug 303422.","DOI":"10.1136\/bjophthalmol-2013-303400"},{"issue":"8","key":"1064_CR18","doi-asserted-by":"publisher","first-page":"568","DOI":"10.1097\/IJG.0000000000000133","volume":"24","author":"ML Salvetat","year":"2015","unstructured":"Salvetat ML, Zeppieri M, Tosoni C, Felletti M, Grasso L, Brusini P. Corneal deformation parameters provided by the Corvis-ST Pachy-tonometer in healthy subjects and Glaucoma patients. J Glaucoma. 2015;24(8):568\u201374. \n                    https:\/\/doi.org\/10.1097\/IJG.0000000000000133\n                    \n                  .","journal-title":"J Glaucoma"},{"issue":"10","key":"1064_CR19","first-page":"12672","volume":"1","author":"L Tian","year":"2015","unstructured":"Tian L, Wang D, Wu Y, Meng X, Chen B, Ge M, Huang Y. Corneal biomechanical characteristics measured by the CorVis Scheimpflug technology in eyes with primary open-angle glaucoma and normal eyes. Acta Ophthalmol. 2015;1(10):12672.","journal-title":"Acta Ophthalmol"},{"issue":"9","key":"1064_CR20","doi-asserted-by":"publisher","first-page":"5557","DOI":"10.1167\/iovs.5515-16926","volume":"56","author":"W Wang","year":"2015","unstructured":"Wang W, Du S, Zhang X. Corneal deformation response in patients with primary open-angle Glaucoma and in healthy subjects analyzed by Corvis ST. Invest Ophthalmol Vis Sci. 2015;56(9):5557\u201365. \n                    https:\/\/doi.org\/10.1167\/iovs.5515-16926\n                    \n                  .","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1064_CR21","doi-asserted-by":"crossref","unstructured":"Vinciguerra R, Elsheikh A, Roberts CJ, Ambrosio R, Jr., Kang DS, Lopes BT, Morenghi E, Azzolini C, Vinciguerra P: Influence of Pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients, J Refract Surg 2016, 32(8):550\u2013561.","DOI":"10.3928\/1081597X-20160524-01"},{"issue":"3","key":"1064_CR22","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1530\/EJE-07-0666","volume":"158","author":"L Bartalena","year":"2008","unstructured":"Bartalena L, Baldeschi L, Dickinson A, Eckstein A, Kendall-Taylor P, Marcocci C, Mourits M, Perros P, Boboridis K, Boschi A, et al. Consensus statement of the European group on Graves' orbitopathy (EUGOGO) on management of GO. Eur J Endocrinol. 2008;158(3):273\u201385.","journal-title":"Eur J Endocrinol"},{"issue":"4","key":"1064_CR23","doi-asserted-by":"publisher","first-page":"266","DOI":"10.3928\/1081597X-20161221-03","volume":"33","author":"CJ Roberts","year":"2017","unstructured":"Roberts CJ, Mahmoud AM, Bons JP, Hossain A, Elsheikh A, Vinciguerra R, Vinciguerra P, Ambrosio R Jr. Introduction of two novel stiffness parameters and interpretation of air puff-induced biomechanical deformation parameters with a dynamic Scheimpflug analyzer. J Refract Surg. 2017;33(4):266\u201373.","journal-title":"J Refract Surg"},{"issue":"8","key":"1064_CR24","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1136\/bjo.73.8.639","volume":"73","author":"MP Mourits","year":"1989","unstructured":"Mourits MP, Koornneef L, Wiersinga WM, Prummel MF, Berghout A, van der Gaag R. Clinical criteria for the assessment of disease activity in Graves' ophthalmopathy: a novel approach. Br J Ophthalmol. 1989;73(8):639\u201344.","journal-title":"Br J Ophthalmol"},{"issue":"1053","key":"1064_CR25","doi-asserted-by":"publisher","first-page":"20150164","DOI":"10.1259\/bjr.20150164","volume":"88","author":"HC Kim","year":"2015","unstructured":"Kim HC, Yoon SW, Lew H. Usefulness of the ratio of orbital fat to total orbit area in mild-to-moderate thyroid-associated ophthalmopathy. Br J Radiol. 2015;88(1053):20150164.","journal-title":"Br J Radiol"},{"issue":"12","key":"1064_CR26","doi-asserted-by":"publisher","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","volume":"32","author":"R Vinciguerra","year":"2016","unstructured":"Vinciguerra R, Ambrosio R Jr, Elsheikh A, Roberts CJ, Lopes B, Morenghi E, Azzolini C, Vinciguerra P. Detection of keratoconus with a new biomechanical index. J Refract Surg. 2016;32(12):803\u201310.","journal-title":"J Refract Surg"},{"issue":"10","key":"1064_CR27","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1016\/j.jcrs.2017.10.012","volume":"43","author":"M Francis","year":"2017","unstructured":"Francis M, Pahuja N, Shroff R, Gowda R, Matalia H, Shetty R, Remington Nelson EJ, Sinha Roy A. Waveform analysis of deformation amplitude and deflection amplitude in normal, suspect, and keratoconic eyes. J Cataract Refract Surg. 2017;43(10):1271\u201380.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"1064_CR28","doi-asserted-by":"publisher","first-page":"e556","DOI":"10.1111\/aos.13466","volume":"95","author":"Y Jung","year":"2017","unstructured":"Jung Y, Park HL, Yang HJ, Park CK. Characteristics of corneal biomechanical responses detected by a non-contact scheimpflug-based tonometer in eyes with glaucoma. Acta Ophthalmol. 2017;95(7):e556\u201363.","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"1064_CR29","doi-asserted-by":"publisher","first-page":"2969","DOI":"10.1038\/s41598-018-21424-8","volume":"8","author":"S Aoki","year":"2018","unstructured":"Aoki S, Murata H, Matsuura M, Fujino Y, Nakakura S, Nakao Y, Kiuchi Y, Asaoka R. The effect of air pulse-driven whole eye motion on the association between corneal hysteresis and glaucomatous visual field progression. Sci Rep. 2018;8(1):2969.","journal-title":"Sci Rep"},{"key":"1064_CR30","first-page":"492","volume":"82","author":"BR Frueh","year":"1984","unstructured":"Frueh BR. Graves\u2019 eye disease: orbital compliance and other physical measurements. Trans Am Ophthalmol Soc. 1984;82:492\u2013598.","journal-title":"Trans Am Ophthalmol Soc"},{"key":"1064_CR31","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.exer.2015.02.007","volume":"142","author":"WA Dik","year":"2016","unstructured":"Dik WA, Virakul S, van Steensel L. Current perspectives on the role of orbital fibroblasts in the pathogenesis of Graves\u2019 ophthalmopathy. Exp Eye Res. 2016;142:83\u201391.","journal-title":"Exp Eye Res"},{"issue":"8","key":"1064_CR32","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1136\/bjophthalmol-2016-309532","volume":"101","author":"HR Vellara","year":"2017","unstructured":"Vellara HR, Hart R, Gokul A, McGhee CNJ, Patel DV. In vivo ocular biomechanical compliance in thyroid eye disease. Br J Ophthalmol. 2017;101(8):1076\u20139.","journal-title":"Br J Ophthalmol"},{"issue":"3","key":"1064_CR33","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1080\/02713683.2017.1405044","volume":"43","author":"A Leszczynska","year":"2018","unstructured":"Leszczynska A, Moehler K, Spoerl E, Ramm L, Herber R, Pillunat LE, Terai N. Measurement of orbital biomechanical properties in patients with thyroid Orbitopathy using the dynamic Scheimpflug analyzer (Corvis ST). Curr Eye Res. 2018;43(3):289\u201392.","journal-title":"Curr Eye Res"},{"issue":"11","key":"1064_CR34","doi-asserted-by":"publisher","first-page":"6941","DOI":"10.1167\/iovs.15-17396","volume":"56","author":"HR Vellara","year":"2015","unstructured":"Vellara HR, Ali NQ, Gokul A, Turuwhenua J, Patel DV, McGhee CN. Quantitative analysis of corneal energy dissipation and corneal and orbital deformation in response to an air-pulse in healthy eyes. Invest Ophthalmol Vis Sci. 2015;56(11):6941\u20137.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1064_CR35","volume-title":"Duane\u2019s Clinical Ophthalmology","author":"D Deborah","year":"2012","unstructured":"Deborah D, Sherman CNB, Bradley N, Lemke. In: TDJ D, Edward A, editors. Duane\u2019s Clinical Ophthalmology, vol. 2. Philadelphia: Lippincott Williams & Wilkins; 2012."},{"issue":"11","key":"1064_CR36","doi-asserted-by":"publisher","first-page":"6941","DOI":"10.1167\/iovs.6915-17396","volume":"56","author":"HR Vellara","year":"2015","unstructured":"Vellara HR, Ali NQ, Gokul A, Turuwhenua J, Patel DV, McGhee CN. Quantitative analysis of corneal energy dissipation and corneal and orbital deformation in response to an air-pulse in healthy eyes. Invest Ophthalmol Vis Sci. 2015;56(11):6941\u20137. \n                    https:\/\/doi.org\/10.1167\/iovs.6915-17396\n                    \n                  .","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-019-1064-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-019-1064-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-019-1064-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T10:30:25Z","timestamp":1582021825000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-019-1064-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,18]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1064"],"URL":"https:\/\/doi.org\/10.1186\/s12886-019-1064-7","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,18]]},"assertion":[{"value":"26 April 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 February 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study adhered to the tenets of the Declaration of Helsinki and received institutional review board (IRB) approval from Seoul St. Mary\u2019s Hospital for the analysis of their medical records. The need for consent was waived by IRB (name of IRB: CMC IRB).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"HHS is a member of the editorial board (Associate Editor) of BMC ophthalmology. The other authors declare that they have no competing interests. The authors declare that they have no financial competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"53"}}