{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T20:05:40Z","timestamp":1793649940133,"version":"4.5.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,8,9]],"date-time":"2019-08-09T00:00:00Z","timestamp":1565308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,8,9]],"date-time":"2019-08-09T00:00:00Z","timestamp":1565308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>This study is to evaluate the accuracy of machine learning for differentiation between optic neuropathies, pseudopapilledema (PPE) and normals.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Two hundred and ninety-five images of optic neuropathies, 295 images of PPE, and 779 control images were used. Pseudopapilledema was defined as follows: cases with elevated optic nerve head and blurred disc margin, with normal visual acuity (&gt;\u20090.8 Snellen visual acuity), visual field, color vision, and pupillary reflex. The optic neuropathy group included cases of ischemic optic neuropathy (177), optic neuritis (48), diabetic optic neuropathy (17), papilledema (22), and retinal disorders (31). We compared four machine learning classifiers (our model, GoogleNet Inception v3, 19-layer Very Deep Convolution Network from Visual Geometry group (VGG), and 50-layer Deep Residual Learning (ResNet)). Accuracy and area under receiver operating characteristic curve (AUROC) were analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The accuracy of machine learning classifiers ranged from 95.89 to 98.63% (our model: 95.89%, Inception V3: 96.45%, ResNet: 98.63%, and VGG: 96.80%). A high AUROC score was noted in both ResNet and VGG (0.999).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Machine learning techniques can be combined with fundus photography as an effective approach to distinguish between PPE and elevated optic disc associated with optic neuropathies.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-019-1184-0","type":"journal-article","created":{"date-parts":[[2019,8,9]],"date-time":"2019-08-09T07:02:36Z","timestamp":1565334156000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":57,"title":["Accuracy of machine learning for differentiation between optic neuropathies and pseudopapilledema"],"prefix":"10.1186","volume":"19","author":[{"given":"Jin Mo","family":"Ahn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sangsoo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kwang-Sung","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Hoon","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2373-6240","authenticated-orcid":false,"given":"Ungsoo S.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,8,9]]},"reference":[{"key":"1184_CR1","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1097\/00041327-200112000-00002","volume":"21","author":"GL Trick","year":"2001","unstructured":"Trick GL, Bhatt SS, Dahl D, Skarf B. Optic disc topography in pseudopapilledema: a comparison to pseudotumor cerebri. J Neuroophthalmol. 2001;21:240\u20134.","journal-title":"J Neuroophthalmol"},{"key":"1184_CR2","doi-asserted-by":"crossref","unstructured":"Aghsaei Fard M, Okhravi S, Moghimi S, Subramanian PS. Optic nerve head and macular optical coherence tomography measurements in papilledema compared with Pseudopapilledema. J Neuroophthalmol. 2018.","DOI":"10.1097\/WNO.0000000000000641"},{"key":"1184_CR3","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.jaapos.2017.09.003","volume":"22","author":"AC Thompson","year":"2018","unstructured":"Thompson AC, Bhatti MT, El-Dairi MA. Bruch's membrane opening on optical coherence tomography in pediatric papilledema and pseudopapilledema. J AAPOS. 2018;22:38\u201343 e3.","journal-title":"J AAPOS"},{"key":"1184_CR4","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1097\/OPX.0000000000001148","volume":"94","author":"R Saenz","year":"2017","unstructured":"Saenz R, Cheng H, Prager TC, Frishman LJ, Tang RA. Use of A-scan ultrasound and optical coherence tomography to differentiate papilledema from Pseudopapilledema. Optom Vis Sci. 2017;94:1081\u20139.","journal-title":"Optom Vis Sci"},{"key":"1184_CR5","doi-asserted-by":"publisher","first-page":"2402","DOI":"10.1001\/jama.2016.17216","volume":"316","author":"V Gulshan","year":"2016","unstructured":"Gulshan V, Peng L, Coram M, et al. Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs. JAMA. 2016;316:2402\u201310.","journal-title":"JAMA"},{"key":"1184_CR6","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0177726","volume":"12","author":"SJ Kim","year":"2017","unstructured":"Kim SJ, Cho KJ, Oh S. Development of machine learning models for diagnosis of glaucoma. PLoS One. 2017;12:e0177726.","journal-title":"PLoS One"},{"key":"1184_CR7","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1097\/ICU.0000000000000470","volume":"29","author":"E Rahimy","year":"2018","unstructured":"Rahimy E. Deep learning applications in ophthalmology. Curr Opin Ophthalmol. 2018;29:254\u201360.","journal-title":"Curr Opin Ophthalmol"},{"key":"1184_CR8","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0207982","volume":"13","author":"JM Ahn","year":"2018","unstructured":"Ahn JM, Kim S, Ahn KS, Cho SH, Lee KB, Kim US. A deep learning model for the detection of both advanced and early glaucoma using fundus photography. PLoS One. 2018;13:e0207982.","journal-title":"PLoS One"},{"key":"1184_CR9","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1007\/s00138-008-0126-2","volume":"20","author":"M Ebner","year":"2009","unstructured":"Ebner M. Color constancy based on local space average color. Mach Vis Appl. 2009;20:283\u2013301.","journal-title":"Mach Vis Appl"},{"key":"1184_CR10","doi-asserted-by":"crossref","unstructured":"Wong SC, Gatt A, Stamatescu V, McDonnell MD. Understanding data augmentation for classification: when to warp? arXiv preprint arXiv. 2016:160908764.","DOI":"10.1109\/DICTA.2016.7797091"},{"key":"1184_CR11","unstructured":"Girija SS. Tensorflow: large-scale machine learning on heterogeneous distributed systems. 2016."},{"key":"1184_CR12","first-page":"281","volume":"13","author":"J Bergstra","year":"2012","unstructured":"Bergstra J, Bengio Y. Random search for hyper-parameter optimization. J Mach Learn Res. 2012;13:281\u2013305.","journal-title":"J Mach Learn Res"},{"key":"1184_CR13","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1109\/41.538609","volume":"43","author":"K-F Man","year":"1996","unstructured":"Man K-F, Tang K-S, Kwong S. Genetic algorithms: concepts and applications [in engineering design]. IEEE Trans Ind Electron. 1996;43:519\u201334.","journal-title":"IEEE Trans Ind Electron"},{"key":"1184_CR14","unstructured":"Snoek J, Larochelle H, Adams RP. Practical bayesian optimization of machine learning algorithms. Adv Neural Inf Proces Syst. 2012:2951\u20139."},{"key":"1184_CR15","unstructured":"Kinga D, Adam JB. A method for stochastic optimization. International conference on learning representations (ICLR), 2015."},{"key":"1184_CR16","unstructured":"George D, Shen H, Huerta E. Deep transfer learning: a new deep learning glitch classification method for advanced LIGO. arXiv preprint arXiv. 2017:170607446."},{"key":"1184_CR17","doi-asserted-by":"crossref","unstructured":"Szegedy C, Vanhoucke V, Ioffe S, Shlens J, Wojna Z. Rethinking the inception architecture for computer vision. Proc IEEE Conf Comput Vis Pattern Recognit. 2016:2818\u201326.","DOI":"10.1109\/CVPR.2016.308"},{"key":"1184_CR18","unstructured":"Conneau A, Schwenk H, Barrault L, Lecun Y. Very deep convolutional networks for text classification. arXiv preprint arXiv. 2016:160601781."},{"key":"1184_CR19","doi-asserted-by":"publisher","first-page":"10437","DOI":"10.1007\/s11042-017-4440-4","volume":"77","author":"S Wu","year":"2018","unstructured":"Wu S, Zhong S, Liu Y. Deep residual learning for image steganalysis. Multimed Tools Appl. 2018;77:10437\u201353.","journal-title":"Multimed Tools Appl"},{"key":"1184_CR20","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1007\/s11263-015-0816-y","volume":"115","author":"O Russakovsky","year":"2015","unstructured":"Russakovsky O, Deng J, Su H, et al. Imagenet large scale visual recognition challenge. Int J Comput Vis. 2015;115:211\u201352.","journal-title":"Int J Comput Vis"},{"key":"1184_CR21","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1145\/212094.212114","volume":"27","author":"T Dietterich","year":"1995","unstructured":"Dietterich T. Overfitting and undercomputing in machine learning. ACM Comput Surv (CSUR). 1995;27:326\u20137.","journal-title":"ACM Comput Surv (CSUR)"},{"key":"1184_CR22","unstructured":"Krizhevsky A, Sutskever I, Hinton GE. Imagenet classification with deep convolutional neural networks. Adv Neural Inf Proces Syst. 2012:1097\u2013105."}],"updated-by":[{"DOI":"10.1186\/s12886-026-05503-3","type":"expression_of_concern","label":"Expression of concern","source":"publisher","updated":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T00:00:00Z","timestamp":1793577600000}}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-019-1184-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-019-1184-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-019-1184-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T08:22:29Z","timestamp":1793607749000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-019-1184-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,9]]},"references-count":22,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["1184"],"URL":"https:\/\/doi.org\/10.1186\/s12886-019-1184-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.318\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.318\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,8,9]]},"assertion":[{"value":"4 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 November 2026","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"ExpressionOfConcern","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An Editorial Expression of Concern to this paper has been published:","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12886-026-05503-3","URL":"https:\/\/doi.org\/10.1186\/s12886-026-05503-3","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study was approved by the institutional review board of Kim\u2019s Eye Hospital which waived the requirement for informed consent from participants. It was conducted in accordance with all relevant requirements of the Declaration of Helsinki.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Ethics"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Ethics"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"178"}}