{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,12]],"date-time":"2025-11-12T03:27:14Z","timestamp":1762918034431,"version":"3.37.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T00:00:00Z","timestamp":1565136000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T00:00:00Z","timestamp":1565136000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12886-019-1186-y","type":"journal-article","created":{"date-parts":[[2019,8,7]],"date-time":"2019-08-07T12:02:53Z","timestamp":1565179373000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Corneal biomechanics and intraocular pressure assessment after penetrating keratoplasty for non keratoconic patients, long term results"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8120-0674","authenticated-orcid":false,"given":"Mohamed Samy","family":"Abd Elaziz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hoda Mohamed","family":"Elsobky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adel Galal","family":"Zaky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eslam Ahmed Maher","family":"Hassan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahmoud Tawfik","family":"KhalafAllah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,8,7]]},"reference":[{"key":"1186_CR1","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1097\/00003226-199209000-00012","volume":"11","author":"CM Kirkness","year":"1992","unstructured":"Kirkness CM, Ficker LA. Risk factors for the development of postkeratoplasty glaucoma. Cornea. 1992;11:427\u201332.","journal-title":"Cornea"},{"key":"1186_CR2","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1016\/S0161-6420(87)33542-0","volume":"94","author":"GN Foulks","year":"1987","unstructured":"Foulks GN. Glaucoma associated with penetrating Keratoplasty. Ophthalmology. 1987;94:871\u20134.","journal-title":"Ophthalmology"},{"key":"1186_CR3","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","volume":"31","author":"DA Luce","year":"2005","unstructured":"Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31:156\u201362.","journal-title":"J Cataract Refract Surg"},{"key":"1186_CR4","doi-asserted-by":"publisher","first-page":"3026","DOI":"10.1167\/iovs.04-0694","volume":"48","author":"S Shah","year":"2007","unstructured":"Shah S, Laiquzzaman M, Bhojwani R, et al. Assessment of the biomechanical properties of the cornea with the ocular response analyzer in Normal and Keratoconic eyes. Investig Opthalmology Vis Sci. 2007;48:3026.","journal-title":"Investig Opthalmology Vis Sci"},{"key":"1186_CR5","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1016\/j.jcrs.2007.04.021","volume":"33","author":"D Ortiz","year":"2007","unstructured":"Ortiz D, Pi\u00f1ero D, Shabayek MH, et al. Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg. 2007;33:1371\u20135.","journal-title":"J Cataract Refract Surg"},{"key":"1186_CR6","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1111\/j.1600-0420.2007.01023.x","volume":"86","author":"C Kirwan","year":"2008","unstructured":"Kirwan C, O\u2019Keefe M. Corneal hysteresis using the Reichert ocular response analyser: findings pre- and post-LASIK and LASEK. Acta Ophthalmol. 2008;86:215\u20138.","journal-title":"Acta Ophthalmol"},{"key":"1186_CR7","doi-asserted-by":"publisher","first-page":"2096","DOI":"10.1016\/j.jcrs.2008.08.017","volume":"34","author":"RB Kucumen","year":"2008","unstructured":"Kucumen RB, Yenerel NM, Gorgun E, et al. Corneal biomechanical properties and intraocular pressure changes after phacoemulsification and intraocular lens implantation. J Cataract Refract Surg. 2008;34:2096\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"1186_CR8","doi-asserted-by":"publisher","first-page":"4597","DOI":"10.1167\/iovs.08-2763","volume":"50","author":"A Sahin","year":"2009","unstructured":"Sahin A, Bayer A, Ozge G, Mumcuoglu T. Corneal biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements. Invest Ophthalmol Vis Sci. 2009;50:4597\u2013604.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1186_CR9","doi-asserted-by":"publisher","first-page":"3199","DOI":"10.1167\/iovs.08-3312","volume":"50","author":"MA del Buey","year":"2009","unstructured":"del Buey MA, JA C\u2019b, Ascaso FJ, et al. Biomechanical properties of the cornea in Fuchs\u2019 corneal dystrophy. Investig Opthalmology Vis Sci. 2009;50:3199.","journal-title":"Investig Opthalmology Vis Sci"},{"key":"1186_CR10","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1097\/ICO.0b013e3181967082","volume":"28","author":"K Kamiya","year":"2009","unstructured":"Kamiya K, Shimizu K, Ohmoto F. Comparison of the changes in corneal biomechanical properties after photorefractive keratectomy and laser in situ Keratomileusis. Cornea. 2009;28:765\u20139.","journal-title":"Cornea"},{"key":"1186_CR11","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.clae.2008.12.009","volume":"32","author":"S Shah","year":"2009","unstructured":"Shah S, Laiquzzaman M. Comparison of corneal biomechanics in pre and post-refractive surgery and keratoconic eyes by ocular response Analyser. Contact Lens Anterior Eye. 2009;32:129\u201332.","journal-title":"Contact Lens Anterior Eye"},{"key":"1186_CR12","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1016\/j.survophthal.2018.05.004","volume":"63","author":"J Ma","year":"2018","unstructured":"Ma J, Wang Y, Wei P, Jhanji V. Biomechanics and structure of the cornea: implications and association with corneal disorders. Surv Ophthalmol. 2018;63:851\u201361.","journal-title":"Surv Ophthalmol"},{"key":"1186_CR13","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1111\/opo.12345","volume":"37","author":"S Kling","year":"2017","unstructured":"Kling S, Hafezi F. Corneal biomechanics \u2013 a review. Ophthalmic Physiol Opt. 2017;37:240\u201352.","journal-title":"Ophthalmic Physiol Opt"},{"key":"1186_CR14","doi-asserted-by":"publisher","first-page":"454","DOI":"10.4103\/0301-4738.119317","volume":"62","author":"M Kumar","year":"2014","unstructured":"Kumar M, Murugesan V, Bypareddy R, et al. Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer. Indian J Ophthalmol. 2014;62:454.","journal-title":"Indian J Ophthalmol"},{"key":"1186_CR15","doi-asserted-by":"publisher","first-page":"171","DOI":"10.4274\/tjo.79664","volume":"48","author":"H Gobeka","year":"2018","unstructured":"Gobeka H, E\u011frilmez S, Barut Selver \u00d6, et al. Corneal biomechanical properties of Keratoconic eyes following penetrating Keratoplasty. Turkish J Ophthalmol. 2018;48:171\u20137.","journal-title":"Turkish J Ophthalmol"},{"key":"1186_CR16","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1097\/ICO.0000000000001113","volume":"36","author":"MS Jiang","year":"2017","unstructured":"Jiang MS, Zhu JY, Li X, et al. Corneal biomechanical properties after penetrating Keratoplasty or deep anterior lamellar Keratoplasty using the ocular response analyzer: a meta-analysis. Cornea. 2017;36:310\u20136.","journal-title":"Cornea"},{"key":"1186_CR17","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.survophthal.2007.08.004","volume":"52","author":"A Kotecha","year":"2007","unstructured":"Kotecha A. What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol. 2007;52:109\u201314.","journal-title":"Surv Ophthalmol"},{"key":"1186_CR18","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1159\/000145333","volume":"222","author":"C Kirwan","year":"2008","unstructured":"Kirwan C, O\u2019Malley D, O\u2019Keefe M. Corneal hysteresis and corneal resistance factor in Keratoectasia: findings using the Reichert ocular response analyzer. Ophthalmologica. 2008;222:334\u20137.","journal-title":"Ophthalmologica"},{"key":"1186_CR19","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1016\/j.ophtha.2009.09.023","volume":"117","author":"BM Fontes","year":"2010","unstructured":"Fontes BM, Ambr\u00f3sio R, Jardim D, et al. Corneal biomechanical metrics and anterior segment parameters in mild keratoconus. Ophthalmology. 2010;117:673\u20139.","journal-title":"Ophthalmology"},{"key":"1186_CR20","doi-asserted-by":"publisher","first-page":"2912","DOI":"10.1167\/iovs.09-4304","volume":"51","author":"A Saad","year":"2010","unstructured":"Saad A, Lteif Y, Azan E, Gatinel D. Biomechanical properties of keratoconus suspect eyes. Investig Opthalmology Vis Sci. 2010;51:2912.","journal-title":"Investig Opthalmology Vis Sci"},{"key":"1186_CR21","doi-asserted-by":"publisher","first-page":"774","DOI":"10.1016\/j.ajo.2010.11.007","volume":"151","author":"ID Fabian","year":"2011","unstructured":"Fabian ID, Barequet IS, Skaat A, et al. Intraocular pressure measurements and biomechanical properties of the cornea in eyes after penetrating keratoplasty. Am J Ophthalmol. 2011;151:774\u201381.","journal-title":"Am J Ophthalmol"},{"key":"1186_CR22","first-page":"855","volume":"31","author":"S Feizi","year":"2012","unstructured":"Feizi S, Einollahi B, Yazdani S, Hashemloo A. Graft biomechanical properties after penetrating Keratoplasty in keratoconus. Clin Sci. 2012;31:855\u20138.","journal-title":"Clin Sci"},{"key":"1186_CR23","doi-asserted-by":"publisher","first-page":"139","DOI":"10.3341\/kjo.2010.24.3.139","volume":"24","author":"JY Shin","year":"2010","unstructured":"Shin JY, Choi JS, Oh JY, et al. Evaluation of corneal biomechanical properties following penetrating Keratoplasty using the ocular response analyzer. Korean J Ophthalmol. 2010;24:139.","journal-title":"Korean J Ophthalmol"},{"key":"1186_CR24","doi-asserted-by":"crossref","unstructured":"de Padua Soares Bezerra B, Chan E, Chakrabarti R, Vajpayee RB. Intraocular pressure measurement following corneal transplantation. Surv Ophthalmol. 2019.","DOI":"10.1016\/j.survophthal.2019.02.011"},{"key":"1186_CR25","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1111\/aos.12137","volume":"92","author":"K Clemmensen","year":"2014","unstructured":"Clemmensen K, Hjortdal J. Intraocular pressure and corneal biomechanics in Fuchs\u2019 endothelial dystrophy and after posterior lamellar keratoplasty. Acta Ophthalmol. 2014;92:350\u20134.","journal-title":"Acta Ophthalmol"},{"key":"1186_CR26","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.jfo.2017.06.006","volume":"41","author":"J Hugo","year":"2018","unstructured":"Hugo J, Granget E, Ho Wang Yin G, et al. Intraocular pressure measurements and corneal biomechanical properties using a dynamic Scheimpflug analyzer, after several keratoplasty techniques, versus normal eyes. J Fr Ophtalmol. 2018;41:30\u20138.","journal-title":"J Fr Ophtalmol"},{"key":"1186_CR27","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1016\/j.ajo.2011.08.020","volume":"153","author":"CY Chou","year":"2012","unstructured":"Chou CY, Jordan CA, McGhee CN, et al. Comparison of intraocular pressure measurement using 4 different instruments following penetrating keratoplasty. Am J Ophthalmol. 2012;153:412\u20138.","journal-title":"Am J Ophthalmol"},{"key":"1186_CR28","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1097\/ICO.0b013e3181ca6383","volume":"29","author":"NM Yenerel","year":"2010","unstructured":"Yenerel NM, Kucumen RB, Gorgun E. Changes in corneal biomechanics in patients with keratoconus after penetrating keratoplasty. Cornea. 2010;29:1247\u201351.","journal-title":"Cornea"},{"key":"1186_CR29","doi-asserted-by":"publisher","first-page":"767","DOI":"10.2147\/OPTH.S21297","volume":"5","author":"M Hosny","year":"2011","unstructured":"Hosny M, Hassaballa MAM, Shalaby A. Changes in corneal biomechanics following different keratoplasty techniques. Clin Ophthalmol. 2011;5:767\u201370.","journal-title":"Clin Ophthalmol"},{"key":"1186_CR30","doi-asserted-by":"publisher","first-page":"1644","DOI":"10.1016\/j.ophtha.2009.05.034","volume":"116","author":"TS Vajaranant","year":"2009","unstructured":"Vajaranant TS, Price MO, Price FW, et al. Visual acuity and intraocular pressure after Descemet\u2019s stripping endothelial Keratoplasty in eyes with and without preexisting Glaucoma. Ophthalmology. 2009;116:1644\u201350.","journal-title":"Ophthalmology"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-019-1186-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-019-1186-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-019-1186-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,8,5]],"date-time":"2020-08-05T23:20:59Z","timestamp":1596669659000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-019-1186-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,7]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1186"],"URL":"https:\/\/doi.org\/10.1186\/s12886-019-1186-y","relation":{},"ISSN":["1471-2415"],"issn-type":[{"type":"electronic","value":"1471-2415"}],"subject":[],"published":{"date-parts":[[2019,8,7]]},"assertion":[{"value":"14 December 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by Ethical Committee of the Menoufia University Hospital, all patients received a thorough explanation of the study design and aims followed by a signed informed consent; the study was conducted in compliance with the tenets of the Declaration of Helsinki.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"172"}}