{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T09:45:18Z","timestamp":1787996718879,"version":"build-2784847793"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T00:00:00Z","timestamp":1592524800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T00:00:00Z","timestamp":1592524800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The aim of this study was to investigate the changes in corneal epithelial thickness along the principle meridians of astigmatic corneas after six months of overnight spherical myopic orthokeratology (OK) lens wear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This is a prospective study. Fifty-seven subjects with up to 1.50 diopters (D) of corneal toricity wore spherical OK lenses for 6\u2009months. Evaluations of OK lens fit, visual acuity, refractions and corneal toricity (CT) were performed. Fourier-domain optical coherence tomography (FD-OCT) was conducted to measure the corneal epithelial thickness (ET) along the principle meridians of corneal toricity over a diameter of 6\u2009mm. The means of \u25b3ET of the same diameter at individual meridians (\u25b3ETSm and \u25b3ETFm) were calculated and compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Visual acuity and refraction improved significantly after OK lens wear. \u25b3ETFm thinned more than \u25b3ETSm (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.027) at 1.5\u2009mm in radius. \u25b3ETSm thickened more than \u25b3ETFm at 2.5\u2009mm (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.019) and 3.0\u2009mm (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.036).\u2223\u25b3ETSm - \u25b3ETFm\u2223 were significantly correlated with the baseline central CT at 2.0\u2009mm, 2.5\u2009mm and 3.0\u2009mm. \u2223\u25b3ETSm - \u25b3ETFm\u2223was significantly correlated with the baseline peripheral CT at 2.5\u2009mm.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Overnight wear of spherical OK lenses resulted in differential changes in the thickness profiles of the corneal epithelium between the steep and flat meridians in eyes with corneal toricity.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-020-01477-y","type":"journal-article","created":{"date-parts":[[2020,6,19]],"date-time":"2020-06-19T07:03:52Z","timestamp":1592550232000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Thickness profiles of the corneal epithelium along the steep and flat meridians of astigmatic corneas after orthokeratology"],"prefix":"10.1186","volume":"20","author":[{"given":"Jiaqi","family":"Zhou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feng","family":"Xue","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajeev Krishnan","family":"Naidu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8698-3316","authenticated-orcid":false,"given":"Yishan","family":"Qian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,6,19]]},"reference":[{"key":"1477_CR1","doi-asserted-by":"publisher","first-page":"7077","DOI":"10.1167\/iovs.12-10565","volume":"53","author":"P Cho","year":"2012","unstructured":"Cho P, Cheung SW. Retardation of myopia in Orthokeratology (ROMIO) study: a 2-year randomized clinical trial. Invest Ophthalmol Vis Sci. 2012;53:7077\u201385.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1477_CR2","doi-asserted-by":"publisher","first-page":"3913","DOI":"10.1167\/iovs.11-8453","volume":"53","author":"T Hiraoka","year":"2012","unstructured":"Hiraoka T, Kakita T, Okamoto F, Takahashi H, Oshika T. Long-term effect of overnight orthokeratology on axial length elongation in childhood myopia: a 5-year follow-up study. Invest Ophthalmol Vis Sci. 2012;53:3913\u20139.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1477_CR3","doi-asserted-by":"publisher","first-page":"E1006","DOI":"10.1097\/OPX.0b013e3181b18219","volume":"86","author":"DZ Reinstein","year":"2009","unstructured":"Reinstein DZ, Gobbe M, Archer TJ, Couch D, Bloom B. Epithelial, stromal, and corneal pachymetry changes during orthokeratology. Optom Vis Sci. 2009;86:E1006\u201314.","journal-title":"Optom Vis Sci"},{"key":"1477_CR4","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1167\/iovs.12-10263","volume":"54","author":"Y Lian","year":"2013","unstructured":"Lian Y, Shen M, Jiang J, Mao X, Lu P, Zhu D, Chen Q, Wang J, Lu F. Vertical and horizontal thickness profiles of the corneal epithelium and Bowman\u2019s layer after orthokeratology. Invest Ophthalmol Vis Sci. 2013;54:691\u20136.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"3","key":"1477_CR5","doi-asserted-by":"publisher","first-page":"263","DOI":"10.3109\/02713683.2013.841259","volume":"39","author":"Y Qian","year":"2014","unstructured":"Qian Y, Xue F, Huang J, Qu X, Zhou X, Lanen-Wanek DV. Pachymetry map of corneal epithelium in children wearing orthokeratology contact lenses. Curr Eye Res. 2014;39(3):263\u201370.","journal-title":"Curr Eye Res"},{"issue":"5","key":"1477_CR6","doi-asserted-by":"publisher","first-page":"e377","DOI":"10.1111\/aos.12644","volume":"93","author":"PG Sanfilippo","year":"2015","unstructured":"Sanfilippo PG, Yazar S, Kearns L, Sherwin JC, Hewitt AW, Mackey DA. Distribution of astigmatism as a function of age in an Australian population. Acta Ophthalmol. 2015;93(5):e377\u201385.","journal-title":"Acta Ophthalmol"},{"issue":"11","key":"1477_CR7","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1097\/OPX.0000000000000073","volume":"90","author":"TW Leung","year":"2013","unstructured":"Leung TW, Lam AK, Kee CS. Corneal shapes of Chinese emmetropes and myopic astigmats aged 10 to 45 years. Optom Vis Sci. 2013;90(11):1259\u201366.","journal-title":"Optom Vis Sci"},{"key":"1477_CR8","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1097\/OPX.0000000000000039","volume":"90","author":"V Maseedupally","year":"2013","unstructured":"Maseedupally V, Gifford P, Lum E, Swarbrick H. Central and paracentral corneal curvature changes during orthokeratology. Optom Vis Sci. 2013;90:1249\u201358.","journal-title":"Optom Vis Sci"},{"issue":"9","key":"1477_CR9","doi-asserted-by":"publisher","first-page":"903","DOI":"10.1097\/OPX.0000000000001109","volume":"94","author":"Z Chen","year":"2017","unstructured":"Chen Z, Xue F, Zhou J, Qu X. Zhou X; Shanghai Orthokeratology and study (SOS) group. Prediction of orthokeratology lens decentration with corneal elevation. Optom Vis Sci. 2017;94(9):903\u20137.","journal-title":"Optom Vis Sci"},{"issue":"6","key":"1477_CR10","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1097\/ICL.0b013e3181bdc41f","volume":"35","author":"R Wu","year":"2009","unstructured":"Wu R, Stapleton F, Swarbrick HA. Residual corneal flattening after discontinuation of long-term orthokeratology lens wear in asian children. Eye Contact Lens. 2009;35(6):333\u20137.","journal-title":"Eye Contact Lens."},{"issue":"2","key":"1477_CR11","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1097\/ICL.0000000000000014","volume":"40","author":"J Santodomingo-Rubido","year":"2014","unstructured":"Santodomingo-Rubido J, Villa-Collar C, Gilmartin B, Guti\u00e9rrez-Ortega R. Short-term changes in ocular biometry and refraction after discontinuation of long-term orthokeratology. Eye Contact Lens. 2014;40(2):84\u201390.","journal-title":"Eye Contact Lens."},{"key":"1477_CR12","first-page":"7106028","volume":"2018","author":"Z Chen","year":"2018","unstructured":"Chen Z, Zhou J, Xue F, Zhou X, Qu X. Increased corneal toricity after long-term orthokeratology lens wear. J Ophthamol. 2018;2018:7106028.","journal-title":"J Ophthamol"},{"key":"1477_CR13","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","volume":"119","author":"Y Li","year":"2012","unstructured":"Li Y, Tan O, Brass R, Weiss JL, Huang D. Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology. 2012;119:2425\u201333.","journal-title":"Ophthalmology."},{"key":"1477_CR14","doi-asserted-by":"publisher","first-page":"9659481","DOI":"10.1155\/2017\/9659481","volume":"2017","author":"Y Qian","year":"2017","unstructured":"Qian Y, Liu Y, Zhou X, Naidu RK. Comparison of corneal power and astigmatism between simulated Keratometry, true net power, and Total corneal refractive power before and after SMILE surgery. J Ophthalmol. 2017;2017:9659481.","journal-title":"J Ophthalmol"},{"key":"1477_CR15","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1111\/j.1444-0938.2012.00724.x","volume":"95","author":"E Kim","year":"2012","unstructured":"Kim E, Ehrmann K. Assessment of accuracy and repeatability of anterior segment optical coherence tomography and reproducibility of measurements using a customized software program. Clin Exp Optom. 2012;95:432\u201341.","journal-title":"Clin Exp Optom"},{"key":"1477_CR16","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1097\/ICO.0b013e318186e620","volume":"28","author":"X Zhong","year":"2009","unstructured":"Zhong X, Chen X, Xie RZ, Yang J, Li S, Yang X, Gong X. Differences between overnight and long-term wear of orthokeratology contact lenses in corneal contour, thickness, and cell density. Cornea. 2009;28:271\u20139.","journal-title":"Cornea"},{"key":"1477_CR17","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1097\/01.ICL.0000143635.74169.42","volume":"30","author":"M Matsubara","year":"2004","unstructured":"Matsubara M, Kamei Y, Takeda S, Mukai K, Ishii Y, Ito S. Histologic and histochemical changes in rabbit cornea produced by an orthokeratology lens. Eye Contact Lens. 2004;30:198\u2013204.","journal-title":"Eye Contact Lens."},{"key":"1477_CR18","doi-asserted-by":"crossref","unstructured":"Zhou W , Stojanovic A . Comparison of corneal epithelial and stromal thickness distributions between eyes with keratoconus and healthy eyes with corneal astigmatism \u2265 2.0 D. PLoS One. 2014;9(1):e85994.","DOI":"10.1371\/journal.pone.0085994"},{"issue":"3","key":"1477_CR19","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1097\/ICL.0000000000000031","volume":"40","author":"Y Lian","year":"2014","unstructured":"Lian Y, Shen M, Huang S, Yuan Y, Wang Y, Zhu D, Jiang J, Mao X, Wang J, Lu F. Corneal reshaping and wavefront aberrations during overnight orthokeratology. Eye Contact Lens. 2014;40(3):161\u20138.","journal-title":"Eye Contact Lens"},{"issue":"10 Suppl 1","key":"1477_CR20","doi-asserted-by":"publisher","first-page":"S59","DOI":"10.1097\/01.ico.0000247215.08886.46","volume":"25","author":"T Hiraoka","year":"2006","unstructured":"Hiraoka T, Okamoto F, Kaji Y, Oshika T. Optical quality of the cornea after overnight orthokeratology. Cornea. 2006;25(10 Suppl 1):S59\u201363.","journal-title":"Cornea."},{"key":"1477_CR21","doi-asserted-by":"crossref","unstructured":"Chen J, Huang W, Zhu R, Jiang J, Li Y. Influence of overnight orthokeratology lens fitting decentration on corneal topography reshaping. Eye Vis (Lond). 2018;5:5.","DOI":"10.1186\/s40662-018-0100-7"},{"key":"1477_CR22","doi-asserted-by":"publisher","first-page":"2518","DOI":"10.1167\/iovs.02-0680","volume":"44","author":"A Alharbi","year":"2003","unstructured":"Alharbi A, Swarbrick HA. The effects of overnight orthokeratology lens wear on corneal thickness. Invest Ophthalmol Vis Sci. 2003;44:2518\u201323.","journal-title":"Invest Ophthalmol Vis Sci"}],"updated-by":[{"DOI":"10.1186\/s12886-020-01607-6","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2020,8,18]],"date-time":"2020-08-18T00:00:00Z","timestamp":1597708800000}}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01477-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-020-01477-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01477-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,18]],"date-time":"2021-06-18T19:28:40Z","timestamp":1624044520000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-020-01477-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,19]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1477"],"URL":"https:\/\/doi.org\/10.1186\/s12886-020-01477-y","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.15658\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.15658\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.15658\/v3","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6,19]]},"assertion":[{"value":"24 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2020","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"An amendment to this paper has been published and can be accessed via the original article.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The research described in this study adhered to the tenets of the Declaration of Helsinki and was approved by the ethics committee of the Eye and ENT Hospital of Fudan University. Written consent was obtained from all the participants or their parents if the subjects were younger than 18\u2009years old.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"240"}}