{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T11:24:52Z","timestamp":1781090692340,"version":"3.54.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,8,5]],"date-time":"2020-08-05T00:00:00Z","timestamp":1596585600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,5]],"date-time":"2020-08-05T00:00:00Z","timestamp":1596585600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Non-Profit Central Research Institute Fund of Chinese Academy of Medical Sciences","award":["2018PT32029"],"award-info":[{"award-number":["2018PT32029"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>To investigate swept-source optical coherence tomography angiography (SS-OCTA) for deep choroid visualization and choroidal vascular density (CVD) measurement.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Healthy subjects and central serous chorioretinopathy (CSC) patients were recruited for macular SS-OCTA scans. We evaluated OCTA images at various depths to determine an optimal depth for visualizing choroidal vasculatures. We measured CVD with binarized OCTA images at the optimal depth. In healthy subjects, CVD was studied for its correlation with age, axial length (AL), and subfoveal choroidal thickness (SCT). In CSC eyes, CVD was compared with matched controls.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>Ninety-one healthy eyes and 22 CSC eyes were included. SS-OCTA could display deep choroidal vasculatures as dark signals, with 100\u2009\u03bcm beneath BM as the optimal depth. In healthy subjects, the CVD at 100\u2009\u03bcm beneath BM (56.5\u2009\u00b1\u200910.9%) was significantly correlated with SCT (<jats:italic>P<\/jats:italic>\u2009=\u20090.004) but not with age (<jats:italic>P<\/jats:italic>\u2009=\u20090.49) or AL (<jats:italic>P<\/jats:italic>\u2009=\u20090.72). In CSC eyes, the CVD at 100\u2009\u03bcm beneath BM (62.3\u2009\u00b1\u20096.6%) was larger than that in 22 matched controls (54.1\u2009\u00b1\u20098.0%) (<jats:italic>P<\/jats:italic>\u2009=\u20090.001). The difference remained statistically significant after adjusting for SCT (<jats:italic>P<\/jats:italic>\u2009=\u20090.02).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>SS-OCTA can be used for visualizing deep choroidal vasculatures. CVD measured by OCTA at 100\u2009\u03bcm beneath BM is a useful parameter for quantifying choroidal vascular status.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12886-020-01591-x","type":"journal-article","created":{"date-parts":[[2020,8,5]],"date-time":"2020-08-05T11:02:58Z","timestamp":1596625378000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Visualization of deep choroidal vasculatures and measurement of choroidal vascular density: a swept-source optical coherence tomography angiography approach"],"prefix":"10.1186","volume":"20","author":[{"given":"Erqian","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinyu","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jingyuan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7231-5058","authenticated-orcid":false,"given":"Youxin","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,5]]},"reference":[{"key":"1591_CR1","doi-asserted-by":"publisher","first-page":"2337","DOI":"10.1167\/iovs.11-7823","volume":"53","author":"R Motaghiannezam","year":"2012","unstructured":"Motaghiannezam R, Schwartz DM, Fraser SE. In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm. Invest Ophthalmol Vis Sci. 2012;53:2337\u201348.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1591_CR2","doi-asserted-by":"publisher","first-page":"e0133080","DOI":"10.1371\/journal.pone.0133080","volume":"10","author":"M Adhi","year":"2015","unstructured":"Adhi M, Ferrara D, Mullins RF, et al. Characterization of choroidal layers in normal aging eyes using enface swept-source optical coherence tomography. PLoS One. 2015;10:e0133080.","journal-title":"PLoS One"},{"key":"1591_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ajo.2016.07.006","volume":"170","author":"A Fujiwara","year":"2016","unstructured":"Fujiwara A, Morizane Y, Hosokawa M, et al. Factors affecting Choroidal vascular density in Normal eyes: quantification using en face swept-source optical coherence tomography. Am J Ophthalmol. 2016;170:1\u20139.","journal-title":"Am J Ophthalmol"},{"key":"1591_CR4","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.ajo.2017.09.030","volume":"184","author":"JC Wang","year":"2017","unstructured":"Wang JC, Lains I, Providencia J, et al. Diabetic Choroidopathy: Choroidal vascular density and volume in diabetic retinopathy with swept-source optical coherence tomography. Am J Ophthalmol. 2017;184:75\u201383.","journal-title":"Am J Ophthalmol"},{"key":"1591_CR5","doi-asserted-by":"publisher","first-page":"2309","DOI":"10.1007\/s00417-018-4143-1","volume":"256","author":"J Baek","year":"2018","unstructured":"Baek J, Lee JH, Jung BJ, et al. Morphologic features of large choroidal vessel layer: age-related macular degeneration, polypoidal choroidal vasculopathy, and central serous chorioretinopathy. Graefes Arch Clin Exp Ophthalmol. 2018;256:2309\u201317.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1591_CR6","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1007\/s00417-017-3896-2","volume":"256","author":"M Ang","year":"2018","unstructured":"Ang M, Tan ACS, Cheung CMG, et al. Optical coherence tomography angiography: a review of current and future clinical applications. Graefes Arch Clin Exp Ophthalmol. 2018;256:237\u201345.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1591_CR7","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1016\/j.survophthal.2017.05.006","volume":"62","author":"K Sambhav","year":"2017","unstructured":"Sambhav K, Grover S, Chalam KV. The application of optical coherence tomography angiography in retinal diseases. Surv Ophthalmol. 2017;62:838\u201366.","journal-title":"Surv Ophthalmol"},{"key":"1591_CR8","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1177\/2474126418771805","volume":"2","author":"JD Diaz","year":"2018","unstructured":"Diaz JD, Wang JC, Oellers P, et al. Imaging the deep Choroidal vasculature using spectral domain and swept source optical coherence tomography angiography. J Vitreoretin Dis. 2018;2:146\u201354.","journal-title":"J Vitreoretin Dis"},{"key":"1591_CR9","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.1007\/s00417-019-04318-x","volume":"257","author":"SY Chan","year":"2019","unstructured":"Chan SY, Pan CT, Wang Q, et al. Optical coherent tomographic angiographic pattern of the deep choroidal layer and choriocapillaris after photodynamic therapy for central serous chorioretinopathy. Graefes Arch Clin Exp Ophthalmol. 2019;257:1365\u201372.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1591_CR10","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0081499","volume":"8","author":"W Choi","year":"2013","unstructured":"Choi W, Mohler KJ, Potsaid B, et al. Choriocapillaris and choroidal microvasculature imaging with ultrahigh speed OCT angiography. PLoS One. 2013;8:e81499.","journal-title":"PLoS One"},{"key":"1591_CR11","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1167\/tvst.7.6.25","volume":"7","author":"JC Wang","year":"2018","unstructured":"Wang JC, La\u00edns I, Silverman RF, et al. Visualization of choriocapillaris and choroidal vasculature in healthy eyes with en face swept-source optical coherence tomography versus angiography. Trans VisSci Tech. 2018;7:25.","journal-title":"Trans VisSci Tech"},{"key":"1591_CR12","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1016\/j.ajo.2016.06.043","volume":"169","author":"Y Kuroda","year":"2016","unstructured":"Kuroda Y, Ooto S, Yamashiro K, et al. Increased choroidal vascularity in central serous chorioretinopathy quantified using swept-source optical coherence tomography. Am J Ophthalmol. 2016;169:199\u2013207.","journal-title":"Am J Ophthalmol"},{"key":"1591_CR13","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1111\/ceo.12683","volume":"44","author":"FK Chen","year":"2016","unstructured":"Chen FK, Viljoen RD, Bukowska DM. Classification of image artefacts in optical coherence tomography angiography of the choroid in macular diseases. Clin Exp Ophthalmol. 2016;44:388\u201399.","journal-title":"Clin Exp Ophthalmol"},{"key":"1591_CR14","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1136\/bjophthalmol-2016-309104","volume":"101","author":"K Ghasemi Falavarjani","year":"2017","unstructured":"Ghasemi Falavarjani K, Al-Sheikh M, Akil H, Sadda SR. Image artefacts in swept-source optical coherence tomography angiography. Br J Ophthalmol. 2017;101:564\u20138.","journal-title":"Br J Ophthalmol"},{"key":"1591_CR15","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","volume":"9","author":"N Otsu","year":"1979","unstructured":"Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Syst, Man, Cybern. 1979;9:62\u20136.","journal-title":"IEEE Trans Syst, Man, Cybern"},{"key":"1591_CR16","doi-asserted-by":"publisher","first-page":"E2395","DOI":"10.1073\/pnas.1500185112","volume":"112","author":"Y Jia","year":"2015","unstructured":"Jia Y, Bailey ST, Hwang TS, et al. Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye. Proc Natl Acad Sci U S A. 2015;112:E2395\u2013402.","journal-title":"Proc Natl Acad Sci U S A"},{"key":"1591_CR17","doi-asserted-by":"publisher","first-page":"2175","DOI":"10.1364\/BOE.2.002175","volume":"2","author":"HC Hendargo","year":"2011","unstructured":"Hendargo HC, McNabb RP, Dhalla AH, et al. Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography. Biomed Opt Express. 2011;2:2175\u201388.","journal-title":"Biomed Opt Express"},{"key":"1591_CR18","doi-asserted-by":"publisher","first-page":"5498125","DOI":"10.1155\/2017\/5498125","volume":"2017","author":"R Hua","year":"2017","unstructured":"Hua R, Wang H. Dark signals in the choroidal vasculature on optical coherence tomography angiography: an artefact or not? J Ophthalmol. 2017;2017:5498125.","journal-title":"J Ophthalmol"},{"key":"1591_CR19","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1097\/IAE.0000000000000765","volume":"35","author":"RF Spaide","year":"2015","unstructured":"Spaide RF, Fujimoto JG, Waheed NK. Image artifacts in optical coherence tomography angiography. Retina. 2015;35:2163\u201380.","journal-title":"Retina."},{"key":"1591_CR20","first-page":"2857","volume":"35","author":"RS Ramrattan","year":"1994","unstructured":"Ramrattan RS, van der Schaft TL, Mooy CM, et al. Morphometric analysis of Bruch\u2019s membrane, the choriocapillaris, and the choroid in aging. Invest Ophthalmol Vis Sci. 1994;35:2857\u201364.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1591_CR21","doi-asserted-by":"publisher","first-page":"e99690","DOI":"10.1371\/journal.pone.0099690","volume":"9","author":"M Esmaeelpour","year":"2014","unstructured":"Esmaeelpour M, Kajic V, Zabihian B, et al. Choroidal Haller's and Sattler's layer thickness measurement using 3-dimensional 1060-nm optical coherence tomography. PLoS One. 2014;9:e99690.","journal-title":"PLoS One"},{"key":"1591_CR22","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1007\/s00417-018-04226-6","volume":"257","author":"S Demirel","year":"2019","unstructured":"Demirel S, Ozcan G, Yanik O, et al. Vascular and structural alterations of the choroid evaluated by optical coherence tomography angiography and optical coherence tomography after half-fluence photodynamic therapy in chronic central serous chorioretinopathy. Graefes Arch Clin Exp Ophthalmol. 2019;257:905\u201312.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1591_CR23","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1136\/bjophthalmol-2016-308921","volume":"101","author":"T Izumi","year":"2017","unstructured":"Izumi T, Koizumi H, Maruko I, et al. Structural analyses of choroid after half-dose verteporfin photodynamic therapy for central serous chorioretinopathy. Br J Ophthalmol. 2017;101:433\u20137.","journal-title":"Br J Ophthalmol"},{"key":"1591_CR24","doi-asserted-by":"publisher","first-page":"25","DOI":"10.3928\/23258160-20181212-04","volume":"50","author":"PH Tang","year":"2019","unstructured":"Tang PH, Shields R, Silva RA. Optical coherence tomography angiography findings in chronic central serous Chorioretinopathy after photodynamic therapy. Ophthalmic Surg Lasers Imaging Retina. 2019;50:25\u201332.","journal-title":"Ophthalmic Surg Lasers Imaging Retina"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01591-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-020-01591-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01591-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,4]],"date-time":"2021-08-04T23:41:05Z","timestamp":1628120465000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-020-01591-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,5]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1591"],"URL":"https:\/\/doi.org\/10.1186\/s12886-020-01591-x","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,5]]},"assertion":[{"value":"18 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was in compliance with the tenets of the Declaration of Helsinki. The Ethics Committee of Peking Union Medical College Hospital approved the study protocol. All participants gave written informed consent.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"321"}}