{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:30:41Z","timestamp":1787020241208,"version":"build-2736575974"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,11,16]],"date-time":"2020-11-16T00:00:00Z","timestamp":1605484800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,11,16]],"date-time":"2020-11-16T00:00:00Z","timestamp":1605484800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013318","name":"ShanXi Science and Technology Department","doi-asserted-by":"publisher","award":["201601D021142"],"award-info":[{"award-number":["201601D021142"]}],"id":[{"id":"10.13039\/501100013318","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Currently, there is no standard technique for determining corneal astigmatism. The iTrace wavefront aberrometry of cornea calculated steep power and axis based on the best Zernike mathematical fit from all topo data within 4\u2009mm circle. It was supposed to be more accurate than iTrace simulated keratometry which was calculated based on only 4 points on the circle of 3\u2009mm. This aim of this study was to evaluate visual outcomes and rotational stability after toric intraocular lens (IOL) implantation using the wavefront aberrometry of the cornea with iTrace.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>Setting:<\/jats:bold>\n                      Single site in China, Shanxi Eye Hospital, Shanxi, China.\n                    <\/jats:p>\n                    <jats:p>\n                      <jats:bold>Design:<\/jats:bold>\n                      Prospective case series.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The study included 85 eyes of 63 patients undergoing phacoemulsification and toric IOL implantation. The IOL power and cylinders were chosen with the help of the iTrace toric planning program using wavefront keratometric astigmatism. Astigmatic changes were assessed using Alpins vector method over a 3-month follow-up period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Preoperative mean corneal topographic astigmatism was 1.91 diopters (D)\u2009\u00b1\u20090.69 (standard deviation). Postoperative mean refractive astigmatism decreased significantly to 0.48 D\u2009\u00b1\u20090.34. Surgical induced astigmatism was 1.73 D\u2009\u00b1\u20090.77 and the mean correction index was 0.89\u2009\u00b1\u20090.22, showing a slight undercorrection. The proportion of astigmatism \u22640.50 D increased from 0 to 71.8% postoperatively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This is the first study on evaluation of clinical outcomes of toric IOL implantation in corneal astigmatism patients using iTrace wavefront keratometric readings. The findings show that use of iTrace built-in toric calculator is safe and effective for planning toric IOL surgery for wavefront keratometric astigmatism.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Trial registration<\/jats:title>\n                    <jats:p>\n                      Current Controlled Trials\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"http:\/\/www.isrctn.com\/ISRCTN94956424\">ISRCTN94956424<\/jats:ext-link>\n                      , Retrospectively registered (Date of registration: 05 February 2020).\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-020-01726-0","type":"journal-article","created":{"date-parts":[[2020,11,16]],"date-time":"2020-11-16T08:19:15Z","timestamp":1605514755000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Clinical evaluation of toric intraocular lens implantation based on iTrace wavefront keratometric astigmatism"],"prefix":"10.1186","volume":"20","author":[{"given":"Zhe","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jing","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaqin","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suhua","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,11,16]]},"reference":[{"key":"1726_CR1","doi-asserted-by":"publisher","first-page":"1700","DOI":"10.1016\/j.jcrs.2010.04.043","volume":"36","author":"D Mingo-Botin","year":"2010","unstructured":"Mingo-Botin D, Munoz-Negrete FJ, Won Kim HR, Morcillo-Laiz R, Rebolleda G, Oblanca N. Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery. J Cataract Refract Surg. 2010;36:1700\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR2","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1016\/j.jcrs.2012.07.025","volume":"38","author":"Z Guan","year":"2012","unstructured":"Guan Z, Yuan F, Yuan YZ, Niu WR. Analysis of corneal astigmatism in cataract surgery candidates at a teaching hospital in Shanghai, China. J Cataract Refract Surg. 2012;38:1970\u20137.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR3","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1016\/j.jcrs.2011.04.026","volume":"37","author":"MI Khan","year":"2011","unstructured":"Khan MI, Muhtaseb M. Prevalence of corneal astigmatism in patients having routine cataract surgery at a teaching hospital in the United Kingdom. J Cataract Refract Surg. 2011;37:1751\u20135.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR4","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.jcrs.2012.08.060","volume":"39","author":"W Chen","year":"2013","unstructured":"Chen W, Zuo C, Chen C, Su J, Luo L, Congdon N, Liu Y. Prevalence of corneal astigmatism before cataract surgery in Chinese patients. J Cataract Refract Surg. 2013;39:188\u201392.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR5","first-page":"536412","volume":"2014","author":"X Yuan","year":"2014","unstructured":"Yuan X, Song H, Peng G, Hua X, Tang X. Prevalence of corneal astigmatism in patients before cataract surgery in Northern China. J Ophthalmol. 2014;2014:536412.","journal-title":"J Ophthalmol"},{"key":"1726_CR6","doi-asserted-by":"publisher","first-page":"913","DOI":"10.2147\/OPTH.S205352","volume":"13","author":"JA Davison","year":"2019","unstructured":"Davison JA, Makari S, Potvin R. Clinically relevant differences in the selection of toric intraocular lens power in normal eyes: preoperative measurement vs intraoperative aberrometry. Clin Ophthalmol. 2019;13:913\u201320.","journal-title":"Clin Ophthalmol"},{"issue":"3","key":"1726_CR7","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/j.jcrs.2015.10.069","volume":"42","author":"F Faria-Correia","year":"2016","unstructured":"Faria-Correia F, Lopes B, Monteiro T, Franqueira N, Ambr\u00f3sio R Jr. Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract. J Cataract Refract Surg. 2016;42(3):405\u201311.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR8","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1167\/iovs.14-15903","volume":"56","author":"G Savini","year":"2015","unstructured":"Savini G, N\u00e6ser K. An analysis of the factors influencing the residual refractive astigmatism after cataract surgery with toric intraocular lenses. Invest Ophthalmol Vis Sci. 2015;56:827\u201335.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1726_CR9","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1016\/j.jcrs.2018.04.035","volume":"44","author":"MP Weikert","year":"2018","unstructured":"Weikert MP, Golla A, Wang L. Astigmatism induced by intraocular lens tilt evaluated via ray tracing. J Cataract Refract Surg. 2018;44:745\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR10","doi-asserted-by":"publisher","first-page":"311","DOI":"10.2147\/OPTH.S178277","volume":"13","author":"MX N\u00fa\u00f1ez","year":"2019","unstructured":"N\u00fa\u00f1ez MX, Henriquez MA, Escaf LJ, Ventura BV, Srur M, Newball L, Espaillat A, Centurion VA. Consensus on the management of astigmatism in cataract surgery. Clin Ophthalmol. 2019;13:311\u201324.","journal-title":"Clin Ophthalmol"},{"key":"1726_CR11","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.3109\/02713683.2014.898376","volume":"39","author":"PC Hoffmann","year":"2014","unstructured":"Hoffmann PC, Abraham M, Hirnschall N, Findl O. Prediction of residual astigmatism after cataract surgery using swept source Fourier domain optical coherence tomography. Curr Eye Res. 2014;39:1178\u201386.","journal-title":"Curr Eye Res"},{"key":"1726_CR12","doi-asserted-by":"publisher","first-page":"2242","DOI":"10.1016\/j.jcrs.2015.11.003","volume":"41","author":"BV Ventura","year":"2015","unstructured":"Ventura BV, Al-Mohtaseb Z, Wang L, Koch DD, Weikert MP. Repeatability and comparability of corneal power and corneal astigmatism obtained from a point-source color light-emitting diode topographer, a Placido-based corneal topographer, and a low-coherence reflectometer. J Cataract Refract Surg. 2015;41:2242\u201350.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR13","doi-asserted-by":"publisher","first-page":"923","DOI":"10.2147\/OPTH.S135659","volume":"11","author":"JA Davison","year":"2017","unstructured":"Davison JA, Potvin R. Preoperative measurement vs intraoperative aberrometry for the selection of intraocular lens sphere power in normal eyes. Clin Ophthalmol. 2017;11:923\u20139.","journal-title":"Clin Ophthalmol"},{"key":"1726_CR14","doi-asserted-by":"publisher","first-page":"804","DOI":"10.3928\/1081597X-20131115-03","volume":"29","author":"R Potvin","year":"2013","unstructured":"Potvin R, Gundersen KG, Masket S, Osher RH, Snyder ME, Vann R, Solomon KD, Hill WE. Prospective multicenter study of toric IOL outcomes when dual zone automated keratometry is used for astigmatism planning. J Refract Surg. 2013;29:804\u20139.","journal-title":"J Refract Surg"},{"key":"1726_CR15","doi-asserted-by":"publisher","first-page":"794","DOI":"10.3928\/1081597X-20171004-03","volume":"33","author":"TB Ferreira","year":"2017","unstructured":"Ferreira TB, Ribeiro P, Ribeiro FJ, O\u2019Neill JG. Comparison of methodologies using estimated or measured values of total corneal astigmatism for toric intraocular lens power calculation. J Refract Surg. 2017;33:794\u2013800.","journal-title":"J Refract Surg"},{"key":"1726_CR16","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.jcrs.2016.02.038","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Koch DD, Wang L, Hill WE, Assia EI, Franchina M, Barrett GD. New regression formula for toric intraocular lens calculations. J Cataract Refract Surg. 2016;42:663\u201371.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR17","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.3349\/ymj.2015.56.4.1097","volume":"56","author":"HJ Park","year":"2015","unstructured":"Park HJ, Lee H, Woo YJ, Kim EK, Seo KY, Kim HY, Kim TI. Comparison of the astigmatic power of toric intraocular lenses using three toric calculators. Yonsei Med J. 2015;56:1097\u2013105.","journal-title":"Yonsei Med J"},{"key":"1726_CR18","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.jcrs.2017.07.030","volume":"43","author":"WJ Mayer","year":"2017","unstructured":"Mayer WJ, Kreutzer T, Dirisamer M, Kern C, Kortuem K, Vounotrypidis E, Priglinger S, Kook D. Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation. J Cataract Refract Surg. 2017;43:1281\u20136.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR19","doi-asserted-by":"publisher","first-page":"559","DOI":"10.4103\/0301-4738.191486","volume":"64","author":"S Bhandari","year":"2016","unstructured":"Bhandari S, Nath M. Anterior stromal puncture with staining: a modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses. Indian J Ophthalmol. 2016;64:559\u201362.","journal-title":"Indian J Ophthalmol"},{"key":"1726_CR20","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1016\/j.ophtha.2017.05.025","volume":"124","author":"Y Inoue","year":"2017","unstructured":"Inoue Y, Takehara H, Oshika T. Axis misalignment of toric intraocular lens: placement error and postoperative rotation. Ophthalmology. 2017;124:1424\u20135.","journal-title":"Ophthalmology."},{"key":"1726_CR21","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.jcrs.2017.01.012","volume":"43","author":"JD Solomon","year":"2017","unstructured":"Solomon JD, Ladas J. Toric outcomes: computer-assisted registration versus intraoperative aberrometry. J Cataract Refract Surg. 2017;43:498\u2013504.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR22","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1016\/j.jcrs.2017.03.041","volume":"43","author":"VSC Webers","year":"2017","unstructured":"Webers VSC, Bauer NJC, Visser N, Berendschot TTJM, van den Biggelaar FJHM, Nuijts RMMA. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery. J Cataract Refract Surg. 2017;43:781\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"1726_CR23","doi-asserted-by":"publisher","first-page":"150","DOI":"10.3928\/1081597X-20180115-03","volume":"34","author":"A Pallas","year":"2018","unstructured":"Pallas A, Yeo TK, Trevenen M, Barrett G. Evaluation of the accuracy of two marking methods and the novel toricam application for toric intraocular lens alignment. J Refract Surg. 2018;34:150\u20135.","journal-title":"J Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01726-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-020-01726-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01726-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,16]],"date-time":"2020-11-16T08:40:30Z","timestamp":1605516030000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-020-01726-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,16]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1726"],"URL":"https:\/\/doi.org\/10.1186\/s12886-020-01726-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.24137\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.24137\/v2","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,11,16]]},"assertion":[{"value":"12 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 November 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethics approval and consent to participate This study was approved by the institutional review board at Shanxi Eye Hospital (N20170309); All patients signed an informed consent form prior to enrollment and the study followed the tenets of the Declaration of Helsinki. The consent to participate was given in written format.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"None of the authors received any personal or financial support.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"450"}}