{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,26]],"date-time":"2026-04-26T04:55:27Z","timestamp":1777179327049,"version":"3.51.4"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T00:00:00Z","timestamp":1609977600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T00:00:00Z","timestamp":1609977600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81900854"],"award-info":[{"award-number":["81900854"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Zhejiang Provincial Natural Science Foundation of China","award":["LQ17H120003"],"award-info":[{"award-number":["LQ17H120003"]}]},{"name":"Health and Family Planning Commission of Zhejiang Province, China","award":["2016KYA089"],"award-info":[{"award-number":["2016KYA089"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Implantation of the posterior chamber phakic intraocular lens has been widely performed to correct high and extreme myopia. Chronic intraocular pressure (IOP) elevation may occur in its late postoperative period. For medically uncontrolled cases, surgical treatment is necessary, and benefits should be weighed against risks when determining whether to remove the lens.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 32-year-old man with extremely high myopia presented with progressive blurred vision and medically uncontrolled IOP in the right eye. His past ocular history was significant for bilateral implantable collamer lens (ICL) implantation ten years ago. On ophthalmic examination, the ICL was well placed with a vault height of 456\u00a0\u00b5m in the right eye. The anterior chamber angles were open but narrow, and mild to moderate trabecular pigmentation was noted. Ex-PRESS glaucoma filtration surgery without ICL removal was performed to control IOP. During surgery, an Ex-PRESS P50 shunt was inserted into the anterior chamber via the front edge of the blue-grey transition zone between the sclera and cornea. Transient hypotony and shallow anterior chamber occurred in the first week after surgery, along with an ICL tilt towards the cornea with reduced vault height. No other complications related to either the ICL or the Ex-PRESS shunt were noted. IOP remained stable at 12\u2009~\u200914\u00a0mmHg at the first 3-month follow-up.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Ex-PRESS glaucoma filtration surgery might be a safe and effective alternative treatment for intractable glaucoma with high myopia and ICL implantation. Careful assessment of the ICL position and anterior chamber angle is necessary to plan the appropriate surgical procedure. A postoperative shallow anterior chamber may result in ICL dislocation.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-020-01784-4","type":"journal-article","created":{"date-parts":[[2021,1,7]],"date-time":"2021-01-07T16:03:46Z","timestamp":1610035426000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Ex-PRESS shunt implantation for intractable glaucoma with posterior chamber phakic intraocular lens: a case report"],"prefix":"10.1186","volume":"21","author":[{"given":"Rongrong","family":"Hu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baishuang","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoyu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,7]]},"reference":[{"issue":"6","key":"1784_CR1","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1097\/APO.0000000000000235","volume":"5","author":"X Wang","year":"2016","unstructured":"Wang X, Zhou X. Update on Treating High Myopia With Implantable Collamer Lenses. Asia Pac J Ophthalmol (Phila). 2016;5(6):445\u20139.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"3","key":"1784_CR2","doi-asserted-by":"publisher","first-page":"532-9 e1","DOI":"10.1016\/j.ajo.2013.11.006","volume":"157","author":"A Igarashi","year":"2014","unstructured":"Igarashi A, Shimizu K, Kamiya K. Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia. Am J Ophthalmol. 2014;157(3):532-9 e1.","journal-title":"Am J Ophthalmol"},{"issue":"8","key":"1784_CR3","doi-asserted-by":"publisher","first-page":"548","DOI":"10.3928\/1081597X-20150727-05","volume":"31","author":"T Moya","year":"2015","unstructured":"Moya T, Javaloy J, Montes-Mico R, Beltran J, Munoz G, Montalban R. Implantable Collamer Lens for Myopia: Assessment 12 Years After Implantation. J Refract Surg. 2015;31(8):548\u201356.","journal-title":"J Refract Surg"},{"issue":"6","key":"1784_CR4","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1111\/ceo.12691","volume":"44","author":"J Lee","year":"2016","unstructured":"Lee J, Kim Y, Park S, Bae J, Lee S, Park Y, Lee J, Lee JE. Long-term clinical results of posterior chamber phakic intraocular lens implantation to correct myopia. Clin Exp Ophthalmol. 2016;44(6):481\u20137.","journal-title":"Clin Exp Ophthalmol"},{"issue":"5","key":"1784_CR5","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1001\/jamaophthalmol.2016.0078","volume":"134","author":"I Guber","year":"2016","unstructured":"Guber I, Mouvet V, Bergin C, Perritaz S, Othenin-Girard P, Majo F. Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia. JAMA Ophthalmol. 2016;134(5):487\u201394.","journal-title":"JAMA Ophthalmol"},{"issue":"11","key":"1784_CR6","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.1016\/j.jcrs.2019.06.015","volume":"45","author":"JH Choi","year":"2019","unstructured":"Choi JH, Lim DH, Nam SW, Yang CM, Chung ES, Chung TY. Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia. J Cataract Refract Surg. 2019;45(11):1555\u201361.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"1784_CR7","doi-asserted-by":"publisher","first-page":"765","DOI":"10.3928\/1081597X-20110617-01","volume":"27","author":"P Fernandes","year":"2011","unstructured":"Fernandes P, Gonzalez-Meijome JM, Madrid-Costa D, Ferrer-Blasco T, Jorge J, Montes-Mico R. Implantable collamer posterior chamber intraocular lenses: a review of potential complications. J Refract Surg. 2011;27(10):765\u201376.","journal-title":"J Refract Surg"},{"issue":"2","key":"1784_CR8","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s10792-015-0112-4","volume":"36","author":"S Almalki","year":"2016","unstructured":"Almalki S, Abubaker A, Alsabaani NA, Edward DP. Causes of elevated intraocular pressure following implantation of phakic intraocular lenses for myopia. Int Ophthalmol. 2016;36(2):259\u201365.","journal-title":"Int Ophthalmol"},{"issue":"11","key":"1784_CR9","doi-asserted-by":"publisher","first-page":"e0165469","DOI":"10.1371\/journal.pone.0165469","volume":"11","author":"S Senthil","year":"2016","unstructured":"Senthil S, Choudhari NS, Vaddavalli PK, Murthy S, Reddy JC, Garudadri CS. Etiology and Management of Raised Intraocular Pressure following Posterior Chamber Phakic Intraocular Lens Implantation in Myopic Eyes. PLoS One. 2016;11(11):e0165469.","journal-title":"PLoS One"},{"issue":"5","key":"1784_CR10","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/j.jcrs.2010.11.040","volume":"37","author":"JF Alfonso","year":"2011","unstructured":"Alfonso JF, Baamonde B, Fernandez-Vega L, Fernandes P, Gonzalez-Meijome JM, Montes-Mico R. Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up. J Cataract Refract Surg. 2011;37(5):873\u201380.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"1784_CR11","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1001\/archophthalmol.2009.67","volume":"127","author":"K Kamiya","year":"2009","unstructured":"Kamiya K, Shimizu K, Igarashi A, Hikita F, Komatsu M. Four-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia. Arch Ophthalmol. 2009;127(7):845\u201350.","journal-title":"Arch Ophthalmol"},{"issue":"3","key":"1784_CR12","doi-asserted-by":"publisher","first-page":"251","DOI":"10.3928\/1081597X-20090301-03","volume":"25","author":"TY Chung","year":"2009","unstructured":"Chung TY, Park SC, Lee MO, Ahn K, Chung ES. Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years. J Refract Surg. 2009;25(3):251\u20138.","journal-title":"J Refract Surg"},{"issue":"1","key":"1784_CR13","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/S0002-9394(02)01414-9","volume":"134","author":"CA Sanchez-Galeana","year":"2002","unstructured":"Sanchez-Galeana CA, Zadok D, Montes M, Cortes MA, Chayet AS. Refractory intraocular pressure increase after phakic posterior chamber intraocular lens implantation. Am J Ophthalmol. 2002;134(1):121\u20133.","journal-title":"Am J Ophthalmol"},{"issue":"10108","key":"1784_CR14","doi-asserted-by":"publisher","first-page":"2183","DOI":"10.1016\/S0140-6736(17)31469-1","volume":"390","author":"JB Jonas","year":"2017","unstructured":"Jonas JB, Aung T, Bourne RR, Bron AM, Ritch R, Panda-Jonas S. Glaucoma Lancet. 2017;390(10108):2183\u201393.","journal-title":"Glaucoma Lancet"},{"issue":"2","key":"1784_CR15","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1016\/j.ophtha.2006.06.050","volume":"114","author":"L Xu","year":"2007","unstructured":"Xu L, Wang Y, Wang S, Wang Y, Jonas JB. High myopia and glaucoma susceptibility the Beijing Eye Study. Ophthalmology. 2007;114(2):216\u201320.","journal-title":"Ophthalmology"},{"issue":"10","key":"1784_CR16","doi-asserted-by":"publisher","first-page":"e0138825","DOI":"10.1371\/journal.pone.0138825","volume":"10","author":"N Nagaoka","year":"2015","unstructured":"Nagaoka N, Jonas JB, Morohoshi K, Moriyama M, Shimada N, Yoshida T, Ohno-Matsui K. Glaucomatous-Type Optic Discs in High Myopia. PLoS One. 2015;10(10):e0138825.","journal-title":"PLoS One"},{"issue":"2","key":"1784_CR17","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/S0886-3350(13)80946-7","volume":"19","author":"HR Wilbrandt","year":"1993","unstructured":"Wilbrandt HR, Wilbrandt TH. Evaluation of intraocular pressure fluctuations with differing phacoemulsification approaches. J Cataract Refract Surg. 1993;19(2):223\u201331.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"1784_CR18","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.survophthal.2015.01.001","volume":"60","author":"T Shaarawy","year":"2015","unstructured":"Shaarawy T, Goldberg I, Fechtner R. EX-PRESS glaucoma filtration device: Review of clinical experience and comparison with trabeculectomy. Surv Ophthalmol. 2015;60(4):327\u201345.","journal-title":"Surv Ophthalmol"},{"issue":"3","key":"1784_CR19","doi-asserted-by":"publisher","first-page":"180","DOI":"10.3109\/08820538.2013.771197","volume":"28","author":"S Salim","year":"2013","unstructured":"Salim S. The role of the Ex-PRESS glaucoma filtration device in glaucoma surgery. Semin Ophthalmol. 2013;28(3):180\u20134.","journal-title":"Semin Ophthalmol"},{"issue":"3","key":"1784_CR20","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1097\/IJG.0b013e31824479ce","volume":"22","author":"S Estermann","year":"2013","unstructured":"Estermann S, Yuttitham K, Chen JA, Lee OT, Stamper RL. Comparative in vitro flow study of 3 different Ex-PRESS miniature glaucoma device models. J Glaucoma. 2013;22(3):209\u201314.","journal-title":"J Glaucoma"},{"issue":"1","key":"1784_CR21","doi-asserted-by":"publisher","first-page":"e39","DOI":"10.1097\/IJG.0000000000000243","volume":"25","author":"A Samsudin","year":"2016","unstructured":"Samsudin A, Eames I, Brocchini S, Khaw PT. Evaluation of Dimensional and Flow Properties of ExPress Glaucoma Drainage Devices. J Glaucoma. 2016;25(1):e39\u201345.","journal-title":"J Glaucoma"},{"issue":"5","key":"1784_CR22","doi-asserted-by":"publisher","first-page":"e63591","DOI":"10.1371\/journal.pone.0063591","volume":"8","author":"W Wang","year":"2013","unstructured":"Wang W, Zhou M, Huang W, Zhang X. Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis. PLoS One. 2013;8(5):e63591.","journal-title":"PLoS One"},{"issue":"10","key":"1784_CR23","doi-asserted-by":"publisher","first-page":"e159-e61","DOI":"10.1097\/IJG.0000000000001327","volume":"28","author":"A Hou","year":"2019","unstructured":"Hou A, Hasbrook M, Crandall D. A Case of Uveitis-Hyphema-Glaucoma Syndrome Due to EX-PRESS Glaucoma Filtration Device Implantation. J Glaucoma. 2019;28(10):e159-e61.","journal-title":"J Glaucoma"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01784-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-020-01784-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-01784-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,10]],"date-time":"2021-01-10T19:09:50Z","timestamp":1610305790000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-020-01784-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,7]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1784"],"URL":"https:\/\/doi.org\/10.1186\/s12886-020-01784-4","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,7]]},"assertion":[{"value":"11 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the ethics committee of The First Affiliated Hospital, Zhejiang University School of Medicine and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from the patient for reporting this case.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Patient has provided written consent to report data and publish findings in case report.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"20"}}