{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T20:12:43Z","timestamp":1785787963240,"version":"3.56.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,1,31]],"date-time":"2020-01-31T00:00:00Z","timestamp":1580428800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,1,31]],"date-time":"2020-01-31T00:00:00Z","timestamp":1580428800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["81670820, 81670818"],"award-info":[{"award-number":["81670820, 81670818"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"the Young Scientist Excellence Program, Shanghai","award":["2017YQ055"],"award-info":[{"award-number":["2017YQ055"]}]},{"name":"he New Technology Joint Research Project in Shanghai Hospitals","award":["SHDC12014114"],"award-info":[{"award-number":["SHDC12014114"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Backgroud<\/jats:title>\n                    <jats:p>Previous studies of internal graft-host malappositions have not dealt with the precise ways in which each malapposition affected post-penetrating keratoplasty (post-PK) visual outcomes. In this study, we reviewed our post-PK and post-deep anterior lamellar keratoplasty (post-DALK) keratoconic patients and used anterior segment optical coherence tomography (AS-OCT) to evaluate the associations between graft-host interface (GHI) characteristics and visual outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Novel GHI metrics included: mean graft-host touch (GHT), total prevalence of malapposition proportion (Pm), frequency of apposition (F), size of malapposition (Sm), junctional graft thickness (Tg), junctional host thickness (Th) and the absolute value of difference between Tg and Th (|Tg-Th|). We connected the external and internal junction points of GHI (GHT) and drew a straight line through the central point, perpendicular to both sides of the cornea. Tg and Th were the thicknesses at cross-points 1\u2009mm away from the meeting point on the external side of the graft and host, respectively. Linear regression analysis was used to describe associations between GHI metrics and postsurgical visual outcomes [logarithm of minimum angle of resolution best-corrected visual acuity (logMAR BCVA), spherical equivalent diopter (SE), diopter of spherical power (DS), diopter of cylindrical power (DC) and keratometric astigmatism (Astig value)].<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      We enrolled 22 post-PK and 23 post-DALK keratoconic patients. Compared with the regular-apposition results, GHT was decreased in step and gape patterns, and increased in hill and tag patterns. SE increased averagely by 6.851, 5.428 and 5.164 diopter per 1% increase in: F (step) [\u03b2\u2009=\u20096.851; 95% Confidence interval (CI)\u2009=\u20092.975\u201310.727;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.001]; F (graft step) [\u03b2\u2009=\u20095.428; 95% CI\u2009=\u20091.685\u20139.171;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.005]; and Pm [\u03b2\u2009=\u20095.164; 95%CI\u2009=\u20090.913\u20139.146;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.018], respectively. SE increased averagely by 0.31 diopter per 10-\u03bcm increment in |Tg-Th| [\u03b2\u2009=\u20090.031; 95% CI\u2009=\u20090.009\u20130.054;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.007]. LogMAR BCVA increased (on average) by 0.01 per 10-\u03bcm increment in both GHT [\u03b2\u2009=\u20090.001; 95% CI\u2009=\u20090\u20130.002;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.030]. and Tg [\u03b2\u2009=\u20090.001; 95% CI\u2009=\u20090.001\u20130.002;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.001]. Astig value increased on average by 0.17 diopter per 10-\u03bcm increment in Sm [\u03b2\u2009=\u20090.017; 95% CI\u2009=\u20090\u20130.033;\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.047].\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>This investigation of GHI characteristics suggests explanations for varied ametropia in keratoconic eyes and has potential significance as a reference for promoting pre-surgical planning and technology for corneal transplantation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-020-1307-7","type":"journal-article","created":{"date-parts":[[2020,1,31]],"date-time":"2020-01-31T11:03:51Z","timestamp":1580468631000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Malapposition of graft-host interface after penetrating keratoplasty (PK) and deep anterior lamellar keratoplasty (DALK): an optical coherence tomography study"],"prefix":"10.1186","volume":"20","author":[{"given":"Yujin","family":"Zhao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Zhuang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiaxu","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lijia","family":"Tian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianjiang","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,1,31]]},"reference":[{"key":"1307_CR1","doi-asserted-by":"publisher","first-page":"1947","DOI":"10.1007\/s00417-015-3091-2","volume":"253","author":"T Huang","year":"2015","unstructured":"Huang T, Hu Y, Gui M, Hou C, Zhang H. Comparison of refractive outcomes in three corneal transplantation techniques for keratoconus. Graefes Arch Clin Exp Ophthalmol. 2015;253:1947\u201353.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1307_CR2","doi-asserted-by":"publisher","first-page":"322","DOI":"10.3341\/kjo.2013.27.5.322","volume":"27","author":"BL Oh","year":"2013","unstructured":"Oh BL, Mk K, Wee WR. Comparison of clinical outcomes of same-size grafting between deep anterior lamellar keratoplasty and penetrating keratoplasty for keratoconus. Korean J Ophthalmol. 2013;27:322\u201330.","journal-title":"Korean J Ophthalmol"},{"key":"1307_CR3","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1097\/ICL.0000000000000359","volume":"44","author":"E Yildiz","year":"2018","unstructured":"Yildiz E, Toklu M, Turan VE. Vision-related quality of life before and after deep anterior lamellar Keratoplasty. Eye Contact Lens. 2018;44:144\u20138.","journal-title":"Eye Contact Lens"},{"key":"1307_CR4","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1016\/j.ajo.2010.10.029","volume":"151","author":"A Kubaloglu","year":"2011","unstructured":"Kubaloglu A, Coskun E, Sari ES, Gunes AS, Cinar Y, Pi\u00f1ero DP, et al. Comparison of astigmatic keratotomy results in deep anterior lamellar keratoplasty and penetrating keratoplasty in keratoconus. Am J Ophthalmol. 2011;151:637\u201343.","journal-title":"Am J Ophthalmol"},{"key":"1307_CR5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2011\/708736","volume":"2011","author":"Sepehr Feizi","year":"2011","unstructured":"Feizi S, Zare M. Current approaches for management of postpenetrating keratoplasty astigmatism. J Ophthalmol. 2011. https:\/\/doi.org\/10.1155\/2011\/708736.","journal-title":"Journal of Ophthalmology"},{"key":"1307_CR6","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1097\/ICO.0000000000000647","volume":"35","author":"I Lains","year":"2016","unstructured":"Lains I, Rosa AM, Guerra M, Tavares C, Lobo C, Silva MF, et al. Irregular astigmatism after corneal transplantation-efficacy and safety of topography guided treatment. Cornea. 2016;35:30\u20136.","journal-title":"Cornea"},{"key":"1307_CR7","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1136\/bjophthalmol-2015-306738","volume":"100","author":"H Bayramlar","year":"2016","unstructured":"Bayramlar H, Karadag R, Cakici O, Ozsoy I. Arcuate keratotomy on post-keratoplasty astigmatism is unpredictable and frequently needs repeat procedures to increase its success rate. Br J Ophthalmol. 2016;100:757\u201361.","journal-title":"Br J Ophthalmol"},{"key":"1307_CR8","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1016\/j.ajo.2015.07.005","volume":"160","author":"S Feizi","year":"2015","unstructured":"Feizi S, Javadi MA. Factors predicting refractive outcomes after deep anterior lamellar Keratoplasty in Keratoconus. Am J Ophthalmol. 2015;160:648\u201353.","journal-title":"Am J Ophthalmol"},{"key":"1307_CR9","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.ajo.2007.08.019","volume":"145","author":"LS Lim","year":"2008","unstructured":"Lim LS, Aung HT, Aung T, Tan DT. Corneal imaging with anterior segment optical coherence tomography for lamellar keratoplasty procedures. Am J Ophthalmol. 2008;145:81\u201390.","journal-title":"Am J Ophthalmol"},{"key":"1307_CR10","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.clae.2016.10.001","volume":"40","author":"C Henein","year":"2017","unstructured":"Henein C, Nanavaty MA. Systematic review comparing penetrating keratoplasty and deep anterior lamellar keratoplasty for management of keratoconus. Cont Lens Anterior Eye. 2017;40:3\u201314.","journal-title":"Cont Lens Anterior Eye"},{"key":"1307_CR11","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1007\/s10792-016-0269-5","volume":"37","author":"A Raj","year":"2017","unstructured":"Raj A, Dhasmana R, Bahadur H, Nagpal RC. Monitoring the appositions of posterior graft-host junctions with anterior segment optical coherence tomogram after penetrating keratoplasty. Int Ophthalmol. 2017;37:357\u201364.","journal-title":"Int Ophthalmol"},{"key":"1307_CR12","doi-asserted-by":"publisher","first-page":"1103","DOI":"10.1136\/bjo.2007.129015","volume":"92","author":"I Kaiserman","year":"2008","unstructured":"Kaiserman I, Bahar I, Rootman DS. Corneal wound malapposition after penetrating keratoplasty: an optical coherence tomography study. Br J Ophthalmol. 2008;92:1103\u20137.","journal-title":"Br J Ophthalmol"},{"key":"1307_CR13","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1007\/s10384-014-0309-5","volume":"58","author":"MS Sung","year":"2014","unstructured":"Sung MS, Yoon KC. Evaluation of graft-host interface after penetrating keratoplasty using anterior segment optical coherence tomography. Jpn J Ophthalmol. 2014;58:282\u20139.","journal-title":"Jpn J Ophthalmol"},{"key":"1307_CR14","doi-asserted-by":"publisher","first-page":"676","DOI":"10.3109\/08820538.2016.1169302","volume":"32","author":"UD Uzunel","year":"2017","unstructured":"Uzunel UD, Kusbeci T, Yuksel B. Does the stage of Keratoconus affect optical coherence tomography measurements? Semin Ophthalmol. 2017;32:676\u201381.","journal-title":"Semin Ophthalmol"},{"key":"1307_CR15","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/0002-9394(86)90461-7","volume":"101","author":"L Gk","year":"1986","unstructured":"Gk L, Green WR, Maumenee AE. Clinicopathologic studies of keratoplasty eyes obtained post mortem. Am J Ophthalmol. 1986;101:28\u201340.","journal-title":"Am J Ophthalmol"},{"key":"1307_CR16","doi-asserted-by":"publisher","first-page":"1412","DOI":"10.1136\/bjophthalmol-2015-307604","volume":"100","author":"JJ Meyer","year":"2016","unstructured":"Meyer JJ, McGhee CN. Incidence, severity and outcomes of traumatic wound dehiscence following penetrating and deep anterior lamellar keratoplasty. Br J Ophthalmol. 2016;100:1412\u20135.","journal-title":"Br J Ophthalmol"},{"key":"1307_CR17","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/S0002-9394(14)73257-X","volume":"108","author":"MB Limberg","year":"1989","unstructured":"Limberg MB, Dingeldein SA, Green MT, Klyce SD, Insler MS, Kaufman HE. Corneal compression sutures for the reduction of astigmatism after penetrating keratoplasty. Am J Ophthamol. 1989;108:36\u201342.","journal-title":"Am J Ophthamol"},{"key":"1307_CR18","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1097\/ICO.0b013e3181eed3f8","volume":"30","author":"V Jhanji","year":"2011","unstructured":"Jhanji V, Constantinou M, Beltz J, Vajpayee RB. Evaluation of posterior wound profile after penetrating keratoplasty using anterior segment optical coherence tomography. Cornea. 2011;30:277\u201380.","journal-title":"Cornea"},{"key":"1307_CR19","first-page":"40","volume-title":"Yanqianjie guangxuexiangganduancengsaomiao","author":"J Xu","year":"2013","unstructured":"Xu J, L Q. Yanqianjie guangxuexiangganduancengsaomiao. China: Fudanpress; 2013. p. 40\u20135."},{"key":"1307_CR20","doi-asserted-by":"publisher","first-page":"1515","DOI":"10.2147\/OPTH.S45904","volume":"7","author":"NM Yenerel","year":"2013","unstructured":"Yenerel NM, Rb K. Gorgun E. the complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty. Clin Ophthalmol. 2013;7:1515\u201323.","journal-title":"Clin Ophthalmol"},{"key":"1307_CR21","doi-asserted-by":"publisher","first-page":"5499","DOI":"10.1167\/iovs.07-0591","volume":"48","author":"S Mohamed","year":"2007","unstructured":"Mohamed S, Lee GK, Rao SK, Wong AL, Cheng AC, Li EY, et al. Repeatability and reproducibility of pachymetric mapping with Visante anterior segment-optical coherence tomography. Invest Ophthalmol Vis Sci. 2007;48:5499\u2013504.","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-1307-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-020-1307-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-1307-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,29]],"date-time":"2021-01-29T19:13:54Z","timestamp":1611947634000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-020-1307-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,31]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1307"],"URL":"https:\/\/doi.org\/10.1186\/s12886-020-1307-7","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.78\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.78\/v3","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.78\/v4","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.78\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,31]]},"assertion":[{"value":"26 November 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Written informed consent was obtained from all patients for participation in the study. Approval was received from the Ethics Committee of Shanghai Eye & ENT Hospital of Fudan University.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"41"}}