{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T08:11:27Z","timestamp":1773389487968,"version":"3.50.1"},"reference-count":8,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,2,22]],"date-time":"2020-02-22T00:00:00Z","timestamp":1582329600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,2,22]],"date-time":"2020-02-22T00:00:00Z","timestamp":1582329600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Glaucoma drainage device (GDD) implantation in the anterior chamber are associated with corneal complications. We describe a novel technique to implant GDD tubes in the posterior chamber of pseudophakic eyes.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Ten patients with glaucoma who required GDD tube implantation were included.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The new technique begins with the passage of one of two straight needles existing at each end of a 10\u20130 Polypropylene suture through the GDD tube. A 23-gauge needle then is inserted at an angle 180\u00b0 away and passed from the anterior to the posterior chamber and finally through the sclera. The two suture straight needles from the 10\u20130 Polypropylene suture are positioned in the lumen of the 23-gauge needle. The 23-gauge needle is then extracted from the eye by passing the 2 needles through the lumen. The suture remains inside the posterior chamber, and the tube is inserted into the posterior chamber by pulling on the suture from the other side. No intra-operative complications were found such as bleeding, vitreous tube placement, bent tubes, etc.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>This surgical procedure to implant a tube into the posterior chamber of the pseudophakic eyes is uncomplicated and facilitates the insertion of the flexible tube into the posterior chamber. This eliminates the tendency of the tube to enter the vitreous as the tube is always placed in the posterior chamber away from the cornea.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Trial registration<\/jats:title>\n<jats:p>Current Controlled Trials <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/www.isrctn.com\/ISRCTN14276553\">ISRCTN14276553<\/jats:ext-link> (31th May, 2019) Retrospectively registered.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12886-020-1329-1","type":"journal-article","created":{"date-parts":[[2020,2,22]],"date-time":"2020-02-22T16:02:36Z","timestamp":1582387356000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Ab interno implantation of glaucoma drainage devices tubes in the posterior chamber"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6623-6783","authenticated-orcid":false,"given":"Javier","family":"Moreno-Monta\u00f1\u00e9s","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Concepci\u00f3n","family":"Guirao-Navarro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francisco","family":"Arg\u00fceso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,2,22]]},"reference":[{"issue":"6","key":"1329_CR1","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1136\/bjo.2006.107839","volume":"91","author":"C. Tello","year":"2007","unstructured":"Tello C, Espana EM, Mora R, Dorairaj S, Liebmann JM, Ritch R. Baerveldt glaucoma implant insertion in the posterior chamber sulcus. Br J Ophthalmol. 2007. https:\/\/doi.org\/10.1136\/bjo.2006.107839.","journal-title":"British Journal of Ophthalmology"},{"key":"1329_CR2","unstructured":"Sidoti PA, Mosny AY, Ritterband DC, Seedor JA. Pars Plana Tube Insertion of Glaucoma Drainage Implants and Penetrating Keratoplasty in Patients with Coexisting Glaucoma and Corneal Disease. Vol 108.; 2001. https:\/\/ac.els-cdn.com\/S0161642001005838\/1-s2.0-S0161642001005838-main.pdf?_tid=c0ecb240-0a30-4f84-812e-db67764acb34&acdnat=1534674046_0b94457da4db1bf7ebc295309fdf9a39. Accessed August 19, 2018."},{"key":"1329_CR3","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/j.ajo.2009.04.016","volume":"148","author":"E-K Lee","year":"2009","unstructured":"Lee E-K, Yun Y-J, Lee J-E, Yim J-H, Kim C-S. Changes in corneal endothelial cells after Ahmed Glaucoma valve implantation: 2-year follow-up. AJOPHT. 2009;148:361\u20137. https:\/\/doi.org\/10.1016\/j.ajo.2009.04.016.","journal-title":"AJOPHT."},{"key":"1329_CR4","doi-asserted-by":"publisher","first-page":"75-82.e3","DOI":"10.1016\/j.ajo.2015.11.023","volume":"163","author":"Donald L. Budenz","year":"2016","unstructured":"Budenz DL, Feuer WJ, Barton K, et al. Postoperative Complications in the Ahmed Baerveldt Comparison Study During Five Years of Follow-up. 2016. https:\/\/doi.org\/10.1016\/j.ajo.2015.11.023.","journal-title":"American Journal of Ophthalmology"},{"key":"1329_CR5","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1111\/aos.13161","volume":"95","author":"AN Tan","year":"2017","unstructured":"Tan AN, Webers CAB, Berendschot TTJM, et al. Corneal endothelial cell loss after Baerveldt glaucoma drainage device implantation in the anterior chamber. Acta Ophthalmol. 2017;95:91\u20136. https:\/\/doi.org\/10.1111\/aos.13161.","journal-title":"Acta Ophthalmol"},{"key":"1329_CR6","doi-asserted-by":"publisher","first-page":"1828","DOI":"10.1016\/j.jcrs.2008.05.063","volume":"34","author":"J Moreno-Monta\u00f1\u00e9s","year":"2008","unstructured":"Moreno-Monta\u00f1\u00e9s J, Fantes F, Garc\u00eda-G\u00f3mez P. Polypropylene suture-guided valve tube for posterior chamber implantation in patients with pseudophakic glaucoma. J Cataract Refract Surg. 2008;34:1828\u201331. https:\/\/doi.org\/10.1016\/j.jcrs.2008.05.063.","journal-title":"J Cataract Refract Surg"},{"key":"1329_CR7","doi-asserted-by":"crossref","unstructured":"Reinstein DZ, Archer TJ, Silverman RH, Rondeau MJ, Jackson Coleman D. Correlation of Anterior Chamber Angle and Ciliary Sulcus Diameters with White-to-White Corneal Diameter in High Myopes Using Artemis VHF Digital Ultrasound. Vol 25.; 2009. https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC2649749\/pdf\/nihms78851.pdf. Accessed August 19, 2018.","DOI":"10.3928\/1081597X-20090201-03"},{"issue":"5","key":"1329_CR8","doi-asserted-by":"publisher","first-page":"434","DOI":"10.3928\/15428877-20080901-04","volume":"39","author":"L Camejo","year":"2008","unstructured":"Camejo L, Noecker R. Ab Interno sulcus placement of Glaucoma tube implants. Ophthalmic Surg Lasers Imaging. 2008;39(5):434\u20136. https:\/\/doi.org\/10.3928\/15428877-20080901-04.","journal-title":"Ophthalmic Surg Lasers Imaging"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-1329-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-020-1329-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-020-1329-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,21]],"date-time":"2021-02-21T02:33:59Z","timestamp":1613874839000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-020-1329-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,22]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1329"],"URL":"https:\/\/doi.org\/10.1186\/s12886-020-1329-1","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,22]]},"assertion":[{"value":"10 March 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 February 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Ethics Committee of the University of Navarra. All the participants signed a written consent form.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All the participants signed the consent for the publication of the clinical data of each case and the inclusion of pictures.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"66"}}