{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T20:42:01Z","timestamp":1792096921128,"version":"4.4.0"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T00:00:00Z","timestamp":1615248000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T00:00:00Z","timestamp":1615248000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The current practice for new-born eye examination by an Ophthalmologist in Malaysian hospitals is limited to only preterm new-borns, syndromic or ill infants. Healthy term new-borns are usually discharged without a thorough eye examination. This study is aimed at determining the proportion and types of ocular abnormalities detected in purportedly healthy term new-borns.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>This cross-sectional study is comprised of 203 participants, all purportedly healthy term new-born infants from the Obstetrics and Gynaecology ward at Hospital Kuala Lumpur over a 6\u00a0months period. The examination list includes external eye examination, red reflex test, and fundus imaging using a wide-field digital retinal imaging system (Phoenix Clinical ICON Paediatric Retinal Camera) by a trained Investigator. The pathologies detected were documented. The results were compared and correlated with similar studies published in the literature previously.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Total ocular abnormalities were detected in 34% of the infants. The most common finding was retinal haemorrhage in 29.6% of the infants, of which 53.3% occurred bilaterally. Spontaneous vaginal delivery (SVD) remained the greatest risk factor which has nearly 3.5 times higher risk of new-borns developing retinal haemorrhage compared to Lower Segment Caesarean Section (LSCS). There was a 6% increased likelihood of developing retinal haemorrhage for every 1-min increment in the duration of 2nd stage of labour.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Universal eye screening for all new-borns using a wide-field digital imaging system is realistically possible, safe, and useful in detecting posterior segment disorders. The most common abnormality detected is retinal haemorrhage.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-021-01882-x","type":"journal-article","created":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T04:03:37Z","timestamp":1615262617000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Neonatal eye screening for 203 healthy term new-borns using a wide-field digital retinal imaging system"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6883-9326","authenticated-orcid":false,"given":"Kenneth","family":"Teow Kheng Leong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Siti Nur Amira","family":"Abu Kassim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jasvinjeet Kaur","family":"Sidhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zayani","family":"Zohari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thivakar","family":"Sivalingam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunder","family":"Ramasamy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Safinaz","family":"Mohd Khialdin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noraihan","family":"Mohd Nordin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jamalia","family":"Rahmat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,3,9]]},"reference":[{"key":"1882_CR1","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1016\/j.jpeds.2016.08.048","volume":"179","author":"M Sun","year":"2016","unstructured":"Sun M, Ma A, Li F, Cheng K, Zhang M, Yang H, et al. Sensitivity and specificity of red reflex test in newborn eye screening. J Pediatr. 2016;179:192\u20136 e4.","journal-title":"J Pediatr"},{"issue":"1","key":"1882_CR2","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1038\/eye.2017.129","volume":"32","author":"P Goyal","year":"2018","unstructured":"Goyal P, Padhi TR, Das T, Pradhan L, Sutar S, Butola S, et al. Outcome of universal newborn eye screening with wide-field digital retinal image acquisition system: a pilot study. Eye (Lond). 2018;32(1):67\u201373.","journal-title":"Eye (Lond)"},{"issue":"5","key":"1882_CR3","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1136\/bjophthalmol-2012-302539","volume":"97","author":"LH Li","year":"2013","unstructured":"Li LH, Li N, Zhao JY, Fei P, Zhang GM, Mao JB, et al. Findings of perinatal ocular examination performed on 3573, healthy full-term newborns. Br J Ophthalmol. 2013;97(5):588\u201391.","journal-title":"Br J Ophthalmol"},{"issue":"5","key":"1882_CR4","doi-asserted-by":"publisher","first-page":"e372","DOI":"10.1111\/aos.12685","volume":"93","author":"A Vinekar","year":"2015","unstructured":"Vinekar A, Govindaraj I, Jayadev C, Kumar AK, Sharma P, Mangalesh S, et al. Universal ocular screening of 1021 term infants using wide-field digital imaging in a single public hospital in India - a pilot study. Acta Ophthalmol. 2015;93(5):e372\u20136.","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"1882_CR5","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1186\/s12886-018-0943-7","volume":"18","author":"Y Ma","year":"2018","unstructured":"Ma Y, Deng G, Ma J, Liu J, Li S, Lu H. Universal ocular screening of 481 infants using wide-field digital imaging system. BMC Ophthalmol. 2018;18(1):283.","journal-title":"BMC Ophthalmol"},{"issue":"12","key":"1882_CR6","first-page":"1832","volume":"9","author":"N Mansoor","year":"2016","unstructured":"Mansoor N, Mansoor T, Ahmed M. Eye pathologies in neonates. Int J Ophthalmol. 2016;9(12):1832\u20138.","journal-title":"Int J Ophthalmol"},{"issue":"11","key":"1882_CR7","doi-asserted-by":"publisher","first-page":"2113","DOI":"10.1016\/S0161-6420(03)00831-5","volume":"110","author":"AL Ells","year":"2003","unstructured":"Ells AL, Holmes JM, Astle WF, Williams G, Leske DA, Fielden M, et al. Telemedicine approach to screening for severe retinopathy of prematurity. Ophthalmology. 2003;110(11):2113\u20137.","journal-title":"Ophthalmology."},{"issue":"5","key":"1882_CR8","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1016\/j.ophtha.2016.01.004","volume":"123","author":"NF Callaway","year":"2016","unstructured":"Callaway NF, Ludwig CA, Blumenkranz MS, Jones JM, Fredrick DR, Moshfeghi DM. Retinal and optic nerve hemorrhages in the newborn infant: one-year results of the newborn eye screen test study. Ophthalmology. 2016;123(5):1043\u201352.","journal-title":"Ophthalmology."},{"key":"1882_CR9","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1186\/1471-2431-12-132","volume":"12","author":"MT Moral-Pumarega","year":"2012","unstructured":"Moral-Pumarega MT, Caserio-Carbonero S, De-La-Cruz-Bertolo J, Tejada-Palacios P, Lora-Pablos D, Pallas-Alonso CR. Pain and stress assessment after retinopathy of prematurity screening examination: indirect ophthalmoscopy versus digital retinal imaging. BMC Pediatr. 2012;12:132.","journal-title":"BMC Pediatr"},{"issue":"9","key":"1882_CR10","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1038\/eye.2013.128","volume":"27","author":"MA Sekeroglu","year":"2013","unstructured":"Sekeroglu MA, Hekimoglu E, Sekeroglu HT, Arslan U. Alternative methods for the screening of retinopathy of prematurity: binocular indirect ophthalmoscopy vs wide-field digital retinal imaging. Eye (Lond). 2013;27(9):1053\u20137.","journal-title":"Eye (Lond)."},{"issue":"5","key":"1882_CR11","doi-asserted-by":"publisher","first-page":"1879","DOI":"10.1007\/s10792-017-0670-8","volume":"38","author":"H Gursoy","year":"2018","unstructured":"Gursoy H, Bilgec MD, Erol N, Basmak H, Colak E. The analysis of posterior segment findings in term and premature infants using RetCam images. Int Ophthalmol. 2018;38(5):1879\u201386.","journal-title":"Int Ophthalmol"},{"key":"1882_CR12","doi-asserted-by":"crossref","unstructured":"Simkin SK, Misra SL, Battin M, McGhee CNJ, Dai S. Prospective observational study of universal newborn eye screening in a hospital and community setting in New Zealand. BMJ Paediatr Open. 2019;3:bmjpo-2018-000376.","DOI":"10.1136\/bmjpo-2018-000376"},{"issue":"1","key":"1882_CR13","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/S0161-6420(00)00474-7","volume":"108","author":"MV Emerson","year":"2001","unstructured":"Emerson MV, Pieramici DJ, Stoessel KM, Berreen JP, Gariano RF. Incidence and rate of disappearance of retinal hemorrhage in newborns. Ophthalmology. 2001;108(1):36\u20139.","journal-title":"Ophthalmology."},{"issue":"1","key":"1882_CR14","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1038\/eye.2017.133","volume":"32","author":"RI Chee","year":"2018","unstructured":"Chee RI, Chan RVP. Universal newborn eye screening: an effective strategy to improve ocular health? Eye (Lond). 2018;32(1):50\u20132.","journal-title":"Eye (Lond)."},{"issue":"1","key":"1882_CR15","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1016\/j.jaapos.2012.07.012","volume":"17","author":"P Watts","year":"2013","unstructured":"Watts P, Maguire S, Kwok T, Talabani B, Mann M, Wiener J, et al. Newborn retinal hemorrhages: a systematic review. J AAPOS. 2013;17(1):70\u20138.","journal-title":"J AAPOS"},{"key":"1882_CR16","doi-asserted-by":"publisher","first-page":"4231489","DOI":"10.1155\/2017\/4231489","volume":"2017","author":"Z Yanli","year":"2017","unstructured":"Yanli Z, Qi Z, Yu L, Haike G. Risk factors affecting the severity of full-term neonatal retinal hemorrhage. J Ophthalmol. 2017;2017:4231489.","journal-title":"J Ophthalmol"},{"issue":"4","key":"1882_CR17","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.jfo.2013.06.005","volume":"37","author":"M Laghmari","year":"2014","unstructured":"Laghmari M, Skiker H, Handor H, Mansouri B, Ouazzani Chahdi K, Lachkar R, et al. Birth-related retinal hemorrhages in the newborn: incidence and relationship with maternal, obstetric and neonatal factors. Prospective study of 2,031 cases. J Fr Ophtalmol. 2014;37(4):313\u20139.","journal-title":"J Fr Ophtalmol"},{"issue":"5","key":"1882_CR18","doi-asserted-by":"publisher","first-page":"311","DOI":"10.3341\/kjo.2011.25.5.311","volume":"25","author":"YJ Choi","year":"2011","unstructured":"Choi YJ, Jung MS, Kim SY. Retinal hemorrhage associated with perinatal distress in newborns. Korean J Ophthalmol. 2011;25(5):311\u20136.","journal-title":"Korean J Ophthalmol"},{"issue":"1","key":"1882_CR19","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1186\/s12886-018-0887-y","volume":"18","author":"F Chen","year":"2018","unstructured":"Chen F, Cheng D, Pan J, Huang C, Cai X, Tian Z, et al. The efficacy and safety of Retcam in detecting neonatal retinal hemorrhages. BMC Ophthalmol. 2018;18(1):202.","journal-title":"BMC Ophthalmol"},{"issue":"12","key":"1882_CR20","doi-asserted-by":"publisher","first-page":"983","DOI":"10.3928\/23258160-20171130-05","volume":"48","author":"LH Li","year":"2017","unstructured":"Li LH, Wu WC, Li N, Lu J, Zhang GM, Zhao JY, et al. Full-term neonatal ophthalmic screening in China: a review of 4-year outcomes. Ophthalmic Surg Lasers Imaging Retin. 2017;48(12):983\u201392.","journal-title":"Ophthalmic Surg Lasers Imaging Retin"},{"issue":"4","key":"1882_CR21","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1542\/peds.2007-3667","volume":"122","author":"AR Kemper","year":"2008","unstructured":"Kemper AR, Wallace DK, Quinn GE. Systematic review of digital imaging screening strategies for retinopathy of prematurity. Pediatrics. 2008;122(4):825\u201330.","journal-title":"Pediatrics."}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-021-01882-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12886-021-01882-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-021-01882-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,9]],"date-time":"2021-03-09T04:09:05Z","timestamp":1615262945000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-021-01882-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,9]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["1882"],"URL":"https:\/\/doi.org\/10.1186\/s12886-021-01882-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.16561\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.16561\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,3,9]]},"assertion":[{"value":"23 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 March 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval was obtained from the Universiti Kebangsaan Malaysia (UKM)\/ National University of Malaysia, Research and Ethics Committee (Ethical approval code: FF-2018-438\u2009TB) and the Medical Research & Ethics Committee (MREC), Malaysian Health Ministry (Ethical approval code: NMRR-18-1381-41558). This study adhered to the tenets of the Declaration of Helsinki and Malaysian Guidelines for Good Clinical Practice (GCP). A written informed consent was obtained from the parents\/legal guardians of the minors included in this study, who participated.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent to publish was provided in writing from the appropriate parents or legal guardians of the minors included in the study, as well as the minor used in an image within the consent forms attached to the manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"128"}}