{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T19:25:50Z","timestamp":1762543550331,"version":"3.37.3"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,12,1]],"date-time":"2021-12-01T00:00:00Z","timestamp":1638316800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,12,27]],"date-time":"2021-12-27T00:00:00Z","timestamp":1640563200000},"content-version":"vor","delay-in-days":26,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Despite the XEN gel stent low-risk profile, various complications following the implant have been described, including internal and external occlusion, with a consequent postoperative rise in intraocular pressure (IOP). In this case report we aimed to present a XEN45 stent internal occlusion successfully treated by trimming in situ its proximal end with a 25\u2009G vitreous scissors using a bimanual technique.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 63-year-old male patient affected by primary open angle glaucoma (IOP\u2009=\u200925\u2009mmHg) and a full thickness macular hole in his right eye, underwent ab-interno Xen gel stent implantation and, 1 month later, a 25\u2009G vitrectomy surgery. Despite a significant IOP reduction after stent implant, 6 days after vitrectomy, IOP increased (25\u2009mmHg) and the conjunctival bleb flattened following occlusion of stent internal ostium by a clot of presumed fibrinous material. The Nd:YAG laser failed to remove the clot, so that we decided to snip a small bit of the proximal end of the Xen tube (about 0,5\u2009mm length) with a 25\u2009G vitreous scissors, using a bimanual technique. In the postoperative day 1 and month 1, the IOP was 8\u2009mmHg and 12\u2009mmHg, respectively. The Anterior Segment OCT confirmed a functional, layered, filtering bleb, and the normal appearance and patency of the XEN proximal segment. No side effects from the intervention were observed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Ab interno trimming with vitreous scissors of the occluded proximal end of the XEN stent may represent a safe, rapid and efficient method to restore aqueous humor subconjunctival drainage.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-021-02207-8","type":"journal-article","created":{"date-parts":[[2021,12,27]],"date-time":"2021-12-27T11:05:55Z","timestamp":1640603155000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Xen45 gel stent ab interno trimming for ostium occlusion: case report"],"prefix":"10.1186","volume":"21","author":[{"given":"Filippo","family":"Tatti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pietro","family":"Gentile","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lorenzo","family":"Mangoni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Demarinis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pietro","family":"Napoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1520-7760","authenticated-orcid":false,"given":"Maurizio","family":"Fossarello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,12,27]]},"reference":[{"key":"2207_CR1","doi-asserted-by":"publisher","first-page":"2081","DOI":"10.1016\/j.ophtha.2014.05.013","volume":"121","author":"YC Tham","year":"2014","unstructured":"Tham YC, Li X, Wong TY, Quigley HA, Aung T, Cheng CY. Global prevalence of glaucoma and projections of glaucoma burden through 2040: a systematic review and meta-analysis. Ophthalmology. 2014;121:2081\u201390.","journal-title":"Ophthalmology"},{"key":"2207_CR2","first-page":"1","volume":"101","author":"European Glaucoma Society Terminology and Guidelines for Glaucoma","year":"2017","unstructured":"European Glaucoma Society Terminology and Guidelines for Glaucoma. 4th edition\u2014part 1 supported by the EGS foundation. Br J Ophthalmol. 2017;101:1\u201372.","journal-title":"Br J Ophthalmol"},{"key":"2207_CR3","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1136\/bjophthalmol-2016-EGSguideline.003","volume":"101","author":"European Glaucoma Society","year":"2017","unstructured":"European Glaucoma Society. Terminology and guidelines for Glaucoma: treatment principles and options (chapter 3). Br J Ophthalmol. 2017;101:130\u201395.","journal-title":"Br J Ophthalmol"},{"key":"2207_CR4","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1097\/IIO.0000000000000231","volume":"58","author":"KJ Koike","year":"2018","unstructured":"Koike KJ, Chang PT. Trabeculectomy: a brief history and review of current trends. Int Ophthalmol Clin. 2018;58:117\u201333.","journal-title":"Int Ophthalmol Clin"},{"key":"2207_CR5","doi-asserted-by":"publisher","first-page":"e1","DOI":"10.1097\/IJG.0000000000000521","volume":"26","author":"D Tognetto","year":"2017","unstructured":"Tognetto D, Cecchini P, D\u2019Aloisio R, Vattovani O, Turco G. Scanning electron microscopy evaluation of an EX-PRESS mini glaucoma shunt after explantation. J Glaucoma. 2017;26:e1\u20134.","journal-title":"J Glaucoma"},{"key":"2207_CR6","doi-asserted-by":"publisher","unstructured":"Lavia C, Dallorto L, Maule M, Ceccarelli M, Fea AM. Minimally-invasive glaucoma surgeries (MIGS) for open angle glaucoma: a systematic review and meta-analysis. PLoS One. 2017. https:\/\/doi.org\/10.1371\/journal.pone.0183142.","DOI":"10.1371\/journal.pone.0183142"},{"key":"2207_CR7","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1016\/j.jcrs.2014.01.032","volume":"40","author":"RA Lewis","year":"2014","unstructured":"Lewis RA. Ab interno approach to the subconjunctival space using a collagen glaucoma stent. J Cataract Refract Surg. 2014;40:1301\u20136.","journal-title":"J Cataract Refract Surg"},{"key":"2207_CR8","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1097\/IJG.0000000000001351","volume":"28","author":"J Rigo","year":"2019","unstructured":"Rigo J, Castany M, Banderas S, Pujol O, Amilburu M, Dou A. Possible intraluminal obstruction of the XEN45 gel stent observed with anterior segment optical coherence tomography. J Glaucoma. 2019;28:1095\u2013101.","journal-title":"J Glaucoma"},{"key":"2207_CR9","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1080\/08820538.2019.1581820","volume":"34","author":"A Chatzara","year":"2019","unstructured":"Chatzara A, Chronopoulou I, Theodossiadis G, Theodossiadis P, Chatziralli I. XEN implant for Glaucoma treatment: a review of the literature. Semin Ophthalmol. 2019;34:93\u20137.","journal-title":"Semin Ophthalmol"},{"key":"2207_CR10","doi-asserted-by":"publisher","first-page":"1805","DOI":"10.2147\/OPTH.S178348","volume":"14","author":"AM Fea","year":"2020","unstructured":"Fea AM, Durr GM, Marolo P, Malinverni L, Economou MA, Ahmed I. Xen\u00ae gel stent: a comprehensive review on its use as a treatment option for refractory glaucoma. Clin Ophthalmol. 2020;14:1805\u201332.","journal-title":"Clin Ophthalmol"},{"key":"2207_CR11","doi-asserted-by":"publisher","first-page":"524","DOI":"10.4103\/ijo.IJO_1051_19","volume":"68","author":"Y Scantling-Birch","year":"2020","unstructured":"Scantling-Birch Y, Merzougui W, Lindfield D. Early postoperative lumen blockage of ab-interno gel stent (XEN) cleared with Nd:YAG laser. Indian J Ophthalmol. 2020;68:524.","journal-title":"Indian J Ophthalmol"},{"key":"2207_CR12","doi-asserted-by":"publisher","first-page":"e150","DOI":"10.1097\/IJG.0000000000000625","volume":"26","author":"NP Ferreira","year":"2017","unstructured":"Ferreira NP, Pinto LA, Marques-Neves C. XEN gel stent internal Ostium occlusion: Ab-Interno revision. J Glaucoma. 2017;26:e150\u20132.","journal-title":"J Glaucoma"},{"key":"2207_CR13","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1001\/archopht.120.11.1487","volume":"120","author":"AH Zalta","year":"2002","unstructured":"Zalta AH, Sweeney CP, Zalta AK, Kaufman AH. Intracameral tissue plasminogen activator use in a large series of eyes with valved glaucoma drainage implants. Arch Ophthalmol. 2002;120:1487\u201393.","journal-title":"Arch Ophthalmol"},{"key":"2207_CR14","doi-asserted-by":"publisher","first-page":"1086","DOI":"10.1097\/IJG.0000000000001360","volume":"28","author":"S Olivari","year":"2019","unstructured":"Olivari S, Cutolo CA, Negri L, et al. XEN implant fracture during needling procedure. J Glaucoma. 2019;28:1086\u20139.","journal-title":"J Glaucoma"},{"key":"2207_CR15","doi-asserted-by":"publisher","first-page":"NP11\u20135","DOI":"10.1177\/1120672118805876","volume":"30","author":"Y Bustros","year":"2020","unstructured":"Bustros Y, Chaudhary A, Salinas L, Mansouri K. Cutting the subconjunctival fragment of the XEN gel implant during needling procedure. Eur J Ophthalmol. 2020;30:NP11\u20135.","journal-title":"Eur J Ophthalmol"},{"key":"2207_CR16","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1007\/s40123-020-00234-0","volume":"9","author":"E Linton","year":"2020","unstructured":"Linton E, Au L. Technique of Xen implant revision surgery and the surgical outcomes: a retrospective interventional case series. Ophthalmol Ther. 2020;9:149\u201357.","journal-title":"Ophthalmol Ther"},{"key":"2207_CR17","doi-asserted-by":"publisher","first-page":"e174","DOI":"10.1097\/IJG.0000000000000645","volume":"26","author":"P Baciu","year":"2017","unstructured":"Baciu P, Moster SJ, Lee RK. Rapid intraocular tube trimming for Glaucoma drainage implant devices. J Glaucoma. 2017;26:e174\u20136.","journal-title":"J Glaucoma"},{"key":"2207_CR18","doi-asserted-by":"publisher","first-page":"671","DOI":"10.2147\/OPTH.S163089","volume":"13","author":"D Shroff","year":"2019","unstructured":"Shroff D, Gupt P, Atri N, Gupta C, Shroff C. Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations. Clin Ophthalmol. 2019;13:671\u20138.","journal-title":"Clin Ophthalmol"},{"key":"2207_CR19","doi-asserted-by":"publisher","first-page":"2015","DOI":"10.1167\/iovs.17-23705","volume":"59","author":"J Ling","year":"2018","unstructured":"Ling J, Bell NP, Feldman RM. Sustainable staining of the Xen gel stent. Investig Ophthalmol Vis Sci. 2018;59:2015.","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"2207_CR20","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1038\/s41433-018-0243-8","volume":"33","author":"A Karimi","year":"2019","unstructured":"Karimi A, Lindfield D, Turnbull A, et al. A multi-Centre interventional case series of 259 ab-interno Xen gel implants for glaucoma, with and without combined cataract surgery. Eye. 2019;33:469\u201377.","journal-title":"Eye"},{"key":"2207_CR21","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1097\/IJG.0000000000001002","volume":"27","author":"K Gillmann","year":"2018","unstructured":"Gillmann K, Mansouri K, Bravetti GE, Mermoud A. Chronic intraocular inflammation as a risk factor for XEN gel stent occlusion: a case of microscopic examination of a fibrin-obstructed XEN stent. J Glaucoma. 2018;27:739\u201341.","journal-title":"J Glaucoma"},{"key":"2207_CR22","doi-asserted-by":"publisher","first-page":"93","DOI":"10.5935\/0034-7280.20140021","volume":"73","author":"LP Cunha","year":"2014","unstructured":"Cunha LP, Costa-Cunha LVF, Costa CF, Bastos RR, dos Prata TS, Monteiro MLR. Predictive factors for anterior chamber fibrin formation after vitreoretinal surgery. Rev Bras Oftalmol. 2014;73:93\u20137.","journal-title":"Rev Bras Oftalmol"},{"key":"2207_CR23","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.ogla.2020.05.002","volume":"3","author":"GA Lee","year":"2020","unstructured":"Lee GA, Shah P. YAG laser Xen stent truncation. Ophthalmol Glaucoma. 2020;3:359.","journal-title":"Ophthalmol Glaucoma"},{"key":"2207_CR24","doi-asserted-by":"publisher","first-page":"4789","DOI":"10.1167\/iovs.15-16625","volume":"56","author":"A Sheybani","year":"2015","unstructured":"Sheybani A, Reitsamer H, Ahmed IIK. Fluid dynamics of a novel micro-fistula implant for the surgical treatment of glaucoma. Investig Ophthalmol Vis Sci. 2015;56:4789\u201395.","journal-title":"Investig Ophthalmol Vis Sci"},{"key":"2207_CR25","doi-asserted-by":"publisher","first-page":"2014","DOI":"10.1111\/j.1755-3768.2014.F034.x","volume":"92","author":"NM Jansonius","year":"2014","unstructured":"Jansonius NM. A relationship between tube length and intraocular pressure after glaucoma drainage implant surgery cannot be explained by Poiseuille\u2019s law. Acta Ophthalmol. 2014;92:2014.","journal-title":"Acta Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-021-02207-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-021-02207-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-021-02207-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,27]],"date-time":"2021-12-27T11:09:36Z","timestamp":1640603376000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-021-02207-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,12]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2207"],"URL":"https:\/\/doi.org\/10.1186\/s12886-021-02207-8","relation":{},"ISSN":["1471-2415"],"issn-type":[{"type":"electronic","value":"1471-2415"}],"subject":[],"published":{"date-parts":[[2021,12]]},"assertion":[{"value":"11 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Since only normal clinical practice was described in this case report, formal ethical approval by the Independent Review Board was not required in accordance with the policy of our Institution.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written consent for the publication of this case report, any related information and images was obtained from the patient.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The Authors have no financial or proprietary interest in products, methods, or material used in this case report.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"446"}}