{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T17:47:47Z","timestamp":1778953667917,"version":"3.51.4"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T00:00:00Z","timestamp":1664755200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T00:00:00Z","timestamp":1664755200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>During cataract phacoemulsification surgery, an Intrepid\u00ae balanced (IB) tip can achieve a larger amplitude, which may lead to higher energy efficiency than a Kelman (K) tip when paired with a torsional phaco platform. In this retrospective cohort study, we compared their energy efficiency and damage to the cornea under a new energy setting.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The medical records of 104 eyes of 79 patients were reviewed, with 47 eyes belonging to the IB group and 57 eyes belonging to the K group. All surgeries were performed on an Alcon Centurion\u00ae platform with gravity infiltration. Surgical parameters, visual outcome, central corneal thickness (CCT) changes, and endothelial cell density (ECD) loss rate were recorded and calculated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>No significant differences in postoperative best corrected visual acuity (BCVA), intraocular pressure (IOP), total ultrasound time, estimated fluid aspirated, CCT changes, or ECD loss rate were observed between the two groups. We divided the included eyes into soft nucleus and hard nucleus subgroups and found lower cumulative dissipated energy (CDE, 8.15\u2009\u00b1\u20098.02 vs 14.82\u2009\u00b1\u200914.16, <jats:italic>P<\/jats:italic>\u2009=\u20090.023), cumulative torsional energy (CTE, 8.06\u2009\u00b1\u20097.87 vs 14.13\u2009\u00b1\u200913.02, <jats:italic>P<\/jats:italic>\u2009=\u20090.027), and cumulative longitudinal energy (CLE, 0.09\u2009\u00b1\u20090.17 vs 0.69\u2009\u00b1\u20091.37, <jats:italic>P<\/jats:italic>\u2009=\u20090.017) in the IB group than in the K group, implying less energy used and higher energy efficiency of the IB tip.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Lower CLE in the IB group indicates fewer phaco tip obstructions and a significantly higher capability to conquer hard nuclei with IB tips with statistical significance. With an ultra-perfusion cannula, the balanced tip does not cause more corneal damage.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-022-02619-0","type":"journal-article","created":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T04:02:38Z","timestamp":1664769758000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparisons of the energy efficiency and intraocular safety of two torsional phacoemulsification tips"],"prefix":"10.1186","volume":"22","author":[{"given":"Yan-Xiu","family":"Sun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rong","family":"Cao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zi-Yuan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hua-Qin","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu-Jie","family":"Cen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lu","family":"Gao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dan-Dan","family":"Shi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,10,3]]},"reference":[{"issue":"5","key":"2619_CR1","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1016\/j.jcrs.2009.11.015","volume":"36","author":"B Jun","year":"2010","unstructured":"Jun B, Berdahl JP, Kim T. Thermal study of longitudinal and torsional ultrasound phacoemulsification: tracking the temperature of the corneal surface, incision, and handpiece. J Cataract Refract Surg. 2010;36(5):832\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"2619_CR2","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1016\/j.ajo.2014.04.015","volume":"158","author":"F Helvacioglu","year":"2014","unstructured":"Helvacioglu F, Yeter C, Sencan S, Tunc Z, Uyar OM. Comparison of two different ultrasound methods of phacoemulsification. Am J Ophthalmol. 2014;158(2):221\u201331.","journal-title":"Am J Ophthalmol"},{"key":"2619_CR3","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.2147\/OPTH.S105065","volume":"10","author":"J Zacharias","year":"2016","unstructured":"Zacharias J. Laboratory assessment of thermal characteristics of three phacoemulsification tip designs operated using torsional ultrasound. Clin Ophthalmol. 2016;10:1095\u2013101.","journal-title":"Clin Ophthalmol"},{"issue":"2","key":"2619_CR4","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/j.jcrs.2006.10.044","volume":"33","author":"Y Liu","year":"2007","unstructured":"Liu Y, Zeng M, Liu X, Luo L, Yuan Z, Xia Y, et al. Torsional mode versus conventional ultrasound mode phacoemulsification: randomized comparative clinical study. J Cataract Refract Surg. 2007;33(2):287\u201392.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"2619_CR5","doi-asserted-by":"publisher","first-page":"1417","DOI":"10.4103\/ijo.IJO_7_18","volume":"66","author":"S Dasgupta","year":"2018","unstructured":"Dasgupta S, Mehra R. Comparative studies between longitudinal and torsional modes in phacoemulsification, using active fluidics technology along with the intrepid balanced tip. Indian J Ophthalmol. 2018;66(10):1417\u201322.","journal-title":"Indian J Ophthalmol"},{"issue":"10","key":"2619_CR6","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1016\/j.jcrs.2009.04.046","volume":"35","author":"YK Han","year":"2009","unstructured":"Han YK, Miller KM. Heat production: Longitudinal versus torsional phacoemulsification. J Cataract Refract Surg. 2009;35(10):1799\u2013805.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"2619_CR7","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.jcrs.2013.07.051","volume":"40","author":"F Helvacioglu","year":"2014","unstructured":"Helvacioglu F, Sencan S, Yeter C, Tunc Z, Uyar OM. Outcomes of torsional microcoaxial phacoemulsification using tips with 30-degree and 45-degree aperture angles. J Cataract Refract Surg. 2014;40(3):362\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"2619_CR8","first-page":"1168","volume":"8","author":"S Demircan","year":"2015","unstructured":"Demircan S, Ata\u015f M, G\u00f6kta\u015f E, Ba\u015fkan B. Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification. Int J Ophthalmol. 2015;8(6):1168\u201372.","journal-title":"Int J Ophthalmol"},{"issue":"8","key":"2619_CR9","doi-asserted-by":"publisher","first-page":"e0159049","DOI":"10.1371\/journal.pone.0159049","volume":"11","author":"A Yoo","year":"2016","unstructured":"Yoo A, Nam KY, Tchah H, Kim MJ. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve. PLoS One. 2016;11(8):e0159049 Public Library of Science.","journal-title":"PLoS One"},{"issue":"4","key":"2619_CR10","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1016\/j.jcrs.2016.01.037","volume":"42","author":"KDS Md","year":"2016","unstructured":"Md KDS, Md RL, Mba DF, Md RJC. Clinical study using a new phacoemulsification system with surgical intraocular pressure control. J Cataract Refract Surg. 2016;42(4):542\u20139 ASCRS and ESCRS.","journal-title":"J Cataract Refract Surg"},{"key":"2619_CR11","doi-asserted-by":"publisher","unstructured":"Malik PK, Dewan T, Patidar AK, Sain E. Effect of IOP based infusion system with and without balanced phaco tip on cumulative dissipated energy and estimated fluid usage in comparison to gravity fed infusion in torsional phacoemulsification. Eye Vis. 2017;4:22. https:\/\/doi.org\/10.1186\/s40662-017-0087-5.","DOI":"10.1186\/s40662-017-0087-5"},{"issue":"8","key":"2619_CR12","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1111\/ceo.12748","volume":"44","author":"JD Jensen","year":"2016","unstructured":"Jensen JD, Shi DS, Robinson MS, Kramer GD, Zaugg B, Stagg BC, et al. Torsional power study using CENTURION phacoemulsification technology. Clin Exp Ophthalmol. 2016;44(8):710\u20133 John Wiley & Sons, Ltd.","journal-title":"Clin Exp Ophthalmol"},{"key":"2619_CR13","doi-asserted-by":"publisher","first-page":"1563","DOI":"10.2147\/OPTH.S90245","volume":"9","author":"JA Davison","year":"2015","unstructured":"Davison JA. Two-speed phacoemulsification for soft cataracts using optimized parameters and procedure step toolbar with the CENTURION Vision System and Balanced Tip. Clin Ophthalmol. 2015;9:1563\u201372.","journal-title":"Clin Ophthalmol"},{"issue":"1","key":"2619_CR14","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1111\/ceo.12998","volume":"46","author":"M Pahlitzsch","year":"2018","unstructured":"Pahlitzsch M, Pahlitzsch M-L, Sumarni U, Pahlitzsch T. Can we improve the efficacy of modern cataract surgery by using different tip designs? A comparison of balanced and tapered tip in femtosecond laser-assisted cataract surgery and manual phacoemulsification. Clin Exp Ophthalmol. 2018;46(1):35\u201345 John Wiley & Sons, Ltd.","journal-title":"Clin Exp Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02619-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-022-02619-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02619-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,3]],"date-time":"2022-10-03T04:04:29Z","timestamp":1664769869000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-022-02619-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,3]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2619"],"URL":"https:\/\/doi.org\/10.1186\/s12886-022-02619-0","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,3]]},"assertion":[{"value":"2 February 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective cohort study was approved by the ethical committee of Peking University Third Hospital (M2021666). Written informed consent was obtained from all subjects and\/or their legal guardians for study participation.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable (NA).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"392"}}