{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,18]],"date-time":"2026-05-18T13:51:29Z","timestamp":1779112289324,"version":"3.51.4"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T00:00:00Z","timestamp":1665360000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T00:00:00Z","timestamp":1665360000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Science Foundation of China","doi-asserted-by":"crossref","award":["81500697"],"award-info":[{"award-number":["81500697"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>To compare the accuracy of non-contact tonometry, Pentacam, and corneal visualization Scheimpflug technology (Corvis ST) for the measurement of intraocular pressure (IOP) after small incision lenticule extraction (SMILE) or femtosecond laser-assisted in situ keratomileusis (FS-LASIK) surgery.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A total of 49 patients (98 eyes) undergoing FS-LASIK or SMILE surgery at West China Hospital, Sichuan University from January to March 2021 were enrolled in this prospective, comparative, self-controlled study. IOP values were measured with non-contact tonometer, Pentacam, and Corvis ST before surgery and 1\u00a0month after surgery. Pentacam-derived postoperative IOP values were corrected using five correction formulas (Ehlers, Shah, Dresden, Orssengo-Pye, and Kohlhaas), while Corvis ST-derived values were corrected using a single formula.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In the SMILE group, no significant differences were observed between the IOP values corrected with the Shah formula before and after surgery (<jats:italic>t<\/jats:italic>\u2009=\u20090.17, <jats:italic>P<\/jats:italic>\u2009=\u20090.869), whereas postoperative IOP values corrected with the other formulas were significantly different from the corresponding preoperative measurements (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). In the FS-LASIK group, postoperative IOP values corrected with the Ehlers, Shah, or Corvis ST formulas were significantly different from the corresponding preoperative IOP measurements (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05), but no significant differences were observed between pre- and postoperative IOP values corrected with the Dresden (<jats:italic>t<\/jats:italic>\u2009=\u2009\u2009\u2212\u20090.08, <jats:italic>P<\/jats:italic>\u2009=\u20090.941), Orssengo-Pye (<jats:italic>t<\/jats:italic>\u2009=\u2009\u2009\u2212\u20090.52, <jats:italic>P<\/jats:italic>\u2009=\u20090.604), or Kohlhaas (<jats:italic>t<\/jats:italic>\u2009=\u20091.22, <jats:italic>P<\/jats:italic>\u2009=\u20090.231) formulas.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Pentacam\u2019s Shah correction formula seemed to be the most appropriate method for accurately measuring postoperative IOP in patients undergoing SMILE surgery, while the Dresden, Orssengo-Pye, and Kohlhaas correction formulas of Pentacam were identified as the most reliable methods for estimating IOP in patients after FS-LASIK surgery.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-022-02620-7","type":"journal-article","created":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T12:47:18Z","timestamp":1665406038000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery"],"prefix":"10.1186","volume":"22","author":[{"given":"Zhiqing","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Na","family":"Miao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lixiang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ke","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,10,10]]},"reference":[{"key":"2620_CR1","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s40662-015-0024-4","volume":"2","author":"E Chansue","year":"2015","unstructured":"Chansue E, Tanehsakdi M, Swasdibutra S, McAlinden C. Efficacy, predictability and safety of small incision lenticule extraction (SMILE). Eye and vision (London, England). 2015;2:14.","journal-title":"Eye and vision (London, England)"},{"issue":"10","key":"2620_CR2","doi-asserted-by":"publisher","first-page":"1989","DOI":"10.1016\/j.ophtha.2011.03.012","volume":"118","author":"MW Marcus","year":"2011","unstructured":"Marcus MW, de Vries MM, Junoy Montolio FG, Jansonius NM. Myopia as a risk factor for open-angle glaucoma: a systematic review and meta-analysis. Ophthalmology. 2011;118(10):1989-1994.e1982.","journal-title":"Ophthalmology"},{"issue":"3","key":"2620_CR3","first-page":"365","volume":"52","author":"A Masuda","year":"1998","unstructured":"Masuda A, Shimizu K, Shoji N, Hashimoto Y. Underestimation of intraocular pressure in eyes after refractive surgery. Japanese J Clin Ophthalmol. 1998;52(3):365\u20138.","journal-title":"Japanese J Clin Ophthalmol"},{"issue":"9","key":"2620_CR4","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1016\/S0161-6420(02)01161-2","volume":"109","author":"D Zadok","year":"2002","unstructured":"Zadok D, Raifkup F, Landao D, Frucht-Pery J. Intraocular pressure after LASIK for hyperopia. Ophthalmology. 2002;109(9):1659\u201361.","journal-title":"Ophthalmology"},{"issue":"3","key":"2620_CR5","first-page":"60","volume":"58","author":"T Tomi","year":"2003","unstructured":"Tomi T, Nicula C, Nicula D. Postoperative complications of refractive surgery, Lasik technique. Oftalmologia. 2003;58(3):60\u20133.","journal-title":"Oftalmologia"},{"issue":"4","key":"2620_CR6","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1016\/j.jcrs.2003.12.033","volume":"30","author":"DS Siganos","year":"2004","unstructured":"Siganos DS, Papastergiou GI, Moedas C. Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg. 2004;30(4):746\u201351.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"2620_CR7","doi-asserted-by":"publisher","first-page":"341","DOI":"10.5455\/medarh.2018.72.341-343","volume":"72","author":"V Ajazaj","year":"2018","unstructured":"Ajazaj V, Ka\u00e7aniku G, Asani M, Shabani A, Dida E. Intraocular Pressure After Corneal Refractive Surgery. Med Arch. 2018;72(5):341\u20133.","journal-title":"Med Arch"},{"issue":"4","key":"2620_CR8","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1007\/s10792-012-9701-7","volume":"33","author":"S Hamed-Azzam","year":"2013","unstructured":"Hamed-Azzam S, Briscoe D, Tomkins O, Shehedeh-Mashor R, Garzozi H. Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia. Int Ophthalmol. 2013;33(4):349\u201354.","journal-title":"Int Ophthalmol"},{"key":"2620_CR9","doi-asserted-by":"publisher","first-page":"1069","DOI":"10.2147\/OPTH.S63915","volume":"8","author":"I Yilmaz","year":"2014","unstructured":"Yilmaz I, Altan C, Aygit ED, Alagoz C, Baz O, Ahmet S, Urvasizoglu S, Yasa D, Demirok A. Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL. Clinical ophthalmology (Auckland, NZ). 2014;8:1069\u201374.","journal-title":"Clinical ophthalmology (Auckland, NZ)"},{"issue":"12","key":"2620_CR10","doi-asserted-by":"publisher","first-page":"3441","DOI":"10.19082\/3441","volume":"8","author":"S Emerah","year":"2016","unstructured":"Emerah S, ELZakzouk E, Farag M. Comparison of Central Corneal Thickness Measurements by Pentacam and Ultrasound Pachymetry in Normal Myopic Patients. Electron Physician. 2016;8(12):3441\u20134.","journal-title":"Electron Physician."},{"key":"2620_CR11","first-page":"71","volume":"7","author":"SM Shousha","year":"2013","unstructured":"Shousha SM, Abo Steit MA, Hosny MH, Ewais WA, Shalaby AM. Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery. Clinical ophthalmology (Auckland, NZ). 2013;7:71\u20139.","journal-title":"Clinical ophthalmology (Auckland, NZ)"},{"issue":"1","key":"2620_CR12","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1111\/j.1755-3768.1975.tb01135.x","volume":"53","author":"N Ehlers","year":"1975","unstructured":"Ehlers N, Bramsen T, Sperling S. Applanation tomometry and central corneal thickness. Acta Ophthalmol (Copenh). 1975;53(1):34\u201343.","journal-title":"Acta Ophthalmol (Copenh)"},{"issue":"11","key":"2620_CR13","doi-asserted-by":"publisher","first-page":"2154","DOI":"10.1016\/S0161-6420(99)90498-0","volume":"106","author":"S Shah","year":"1999","unstructured":"Shah S, Chatterjee A, Mathai M, Kelly SP, Kwartz J, Henson D, McLeod D. Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology. 1999;106(11):2154\u201360.","journal-title":"Ophthalmology"},{"issue":"4","key":"2620_CR14","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1001\/archopht.124.4.471","volume":"124","author":"M Kohlhaas","year":"2006","unstructured":"Kohlhaas M, Boehm AG, Spoerl E, P\u00fcrsten A, Grein HJ, Pillunat LE. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol. 2006;124(4):471\u20136.","journal-title":"Arch Ophthalmol"},{"issue":"3","key":"2620_CR15","doi-asserted-by":"publisher","first-page":"263","DOI":"10.3928\/1081-597X-20060301-11","volume":"22","author":"M Kohlhaas","year":"2006","unstructured":"Kohlhaas M, Spoerl E, Boehm AG, Pollack K. A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg. 2006;22(3):263\u20137.","journal-title":"J Refract Surg"},{"issue":"3","key":"2620_CR16","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1006\/bulm.1999.0102","volume":"61","author":"GJ Orssengo","year":"1999","unstructured":"Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61(3):551\u201372.","journal-title":"Bull Math Biol"},{"issue":"9","key":"2620_CR17","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.3349\/ymj.2018.59.9.1115","volume":"59","author":"H Lee","year":"2018","unstructured":"Lee H, Kang DSY, Ha BJ, Choi JY, Kim EK, Seo KY, Kim TI. Biomechanical properties of the cornea using a dynamic scheimpflug analyzer in healthy eyes. Yonsei Med J. 2018;59(9):1115\u201322.","journal-title":"Yonsei Med J"},{"issue":"1","key":"2620_CR18","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s10792-019-01159-9","volume":"40","author":"J Ma","year":"2020","unstructured":"Ma J, Wang Y, Hao W, Jhanji V. Comparative analysis of biomechanically corrected intraocular pressure with corneal visualization Scheimpflug technology versus conventional noncontact intraocular pressure. Int Ophthalmol. 2020;40(1):117\u201324.","journal-title":"Int Ophthalmol"},{"key":"2620_CR19","doi-asserted-by":"publisher","first-page":"5592195","DOI":"10.1155\/2021\/5592195","volume":"2021","author":"CC Chou","year":"2021","unstructured":"Chou CC, Shih PJ, Lin HC, Chen JP, Yen JY, Wang IJ. Changes in Intraocular Pressure after Transepithelial Photorefractive Keratectomy and Femtosecond Laser in Situ Keratomileusis. J Ophthalmol. 2021;2021:5592195.","journal-title":"J Ophthalmol"},{"key":"2620_CR20","first-page":"67","volume":"1","author":"Y He","year":"2009","unstructured":"He Y, Yuan L, Li X, Hu Y. The correction of Goldmann applanation tonometer with Pentacam System in measurement of IOP before and after LASIK (in Chinese). Chin Ophthalmic Res. 2009;1:67\u201370.","journal-title":"Chin Ophthalmic Res"},{"issue":"1","key":"2620_CR21","first-page":"22","volume":"52","author":"H Li","year":"2016","unstructured":"Li H, Wang Y, Dou R, Wang L, Wei P, Zhao W, Li L. Analysis of intraocular pressure measurement and the influencing factors after small incision lenticule extraction (in Chinese). Chin J Ophthalmol. 2016;52(1):22\u20139.","journal-title":"Chin J Ophthalmol"},{"key":"2620_CR22","doi-asserted-by":"publisher","first-page":"683895","DOI":"10.1155\/2015\/683895","volume":"2015","author":"I Cacho","year":"2015","unstructured":"Cacho I, Sanchez-Naves J, Batres L, Pintor J, Carracedo G. Comparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry. J Ophthalmol. 2015;2015:683895.","journal-title":"J Ophthalmol"},{"key":"2620_CR23","first-page":"986","volume":"9","author":"S Zhou","year":"2007","unstructured":"Zhou S, Hu Q, Lu X, Hong H, Mai Q, Li J. Change in intraocnlar pressure in myopic eyes after laser in situ keratomi leusis and assessment of actual intraocular pressure (in Chinese). Chin J Pract Ophthalmol. 2007;9:986\u20138.","journal-title":"Chin J Pract Ophthalmol"},{"key":"2620_CR24","first-page":"930","volume":"9","author":"X Zhang","year":"2008","unstructured":"Zhang X, Li Y. Influence Factors and Prediction ot~ Noncontact Tonometry Measurements after Myopic and Astigmatism LASIK Surgery (in Chinese). Chin J Pract Ophthalmol. 2008;9:930\u20134.","journal-title":"Chin J Pract Ophthalmol"},{"issue":"3","key":"2620_CR25","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1097\/IJG.0b013e31829da1ec","volume":"24","author":"J Shin","year":"2015","unstructured":"Shin J, Kim TW, Park SJ, Yoon M, Lee JW. Changes in biomechanical properties of the cornea and intraocular pressure after myopic laser in situ keratomileusis using a femtosecond laser for flap creation determined using ocular response analyzer and Goldmann applanation tonometry. J Glaucoma. 2015;24(3):195\u2013201.","journal-title":"J Glaucoma"},{"issue":"3","key":"2620_CR26","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.survophthal.2008.02.005","volume":"53","author":"E Chihara","year":"2008","unstructured":"Chihara E. Assessment of True Intraocular Pressure: The Gap Between Theory and Practical Data. Surv Ophthalmol. 2008;53(3):203\u201318.","journal-title":"Surv Ophthalmol"},{"issue":"4","key":"2620_CR27","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1159\/000303213","volume":"134","author":"H Goldmann","year":"1957","unstructured":"Goldmann H, Schmidt T. Applanation tonometry. Ophthalmologica. 1957;134(4):221\u201342.","journal-title":"Ophthalmologica"},{"issue":"1","key":"2620_CR28","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.ophtha.2008.07.014","volume":"116","author":"SS Sandhu","year":"2009","unstructured":"Sandhu SS, Chattopadhyay S, Amariotakis GA, Skarmoutsos F, Birch MK, Ray-Chaudhuri N. The Accuracy of Continued Clinical Use of Goldmann Applanation Tonometers with Known Calibration Errors. Ophthalmology. 2009;116(1):9\u201313.","journal-title":"Ophthalmology"},{"key":"2620_CR29","unstructured":"Zhan S, Pang G, Jin Y, Sun Y. Central corneal thickness and intraocular pressure (in Chinese). Recent Adv Ophthalmol 2001;2:126\u20137."},{"issue":"7","key":"2620_CR30","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1097\/j.jcrs.0000000000000204","volume":"46","author":"S Chen","year":"2020","unstructured":"Chen S, Lopes BT, Huang W, Zheng X, Wang J, Zhu R, Vinciguerra R, Li Y, Wang Q, Li H, et al. Effectiveness of 4 tonometers in measuring IOP after femtosecond laser-assisted LASIK, SMILE, and transepithelial photorefractive keratectomy. J Cataract Refract Surg. 2020;46(7):967\u201374.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"2620_CR31","first-page":"1068","volume":"32","author":"L Hong","year":"2014","unstructured":"Hong L, Li Y. Application of Pentacam system in correction of intraocular pressure after Epi-LASIK (in Chinese). Chin J Pract Ophthalmol. 2014;32(9):1068\u201371.","journal-title":"Chin J Pract Ophthalmol"},{"key":"2620_CR32","first-page":"813","volume":"11","author":"J Zhao","year":"2011","unstructured":"Zhao J, Meng J. Applied comparison between the dynamic contour tonometry and the pentacam system before and after LASIK (in Chinese). J Injuries Occupational Dis Eye with Ophthalmic Surg. 2011;11:813\u20136.","journal-title":"J Injuries Occupational Dis Eye with Ophthalmic Surg"},{"key":"2620_CR33","first-page":"341","volume":"4","author":"Y Li","year":"2020","unstructured":"Li Y, Li J, Zhang J, Ma R, Liang G. Clinical observation on measurement of corneal thickness and intraocular pressure by Corvis st pentacam combined diagnostic system (in Chinese). J Clin Ophthalmol. 2020;4:341\u20136.","journal-title":"J Clin Ophthalmol"},{"key":"2620_CR34","unstructured":"Xiao X, Liu W, Huang J, Wang Y. Accuracy of Corvis ST for the measurement of central corneal thickness and intraocular pressure in myopia (in Chinese). Chin J Exp Ophthalmol. 2016(4):340\u20134."},{"key":"2620_CR35","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.exer.2018.06.013","volume":"175","author":"A Eliasy","year":"2018","unstructured":"Eliasy A, Chen KJ, Vinciguerra R, Maklad O, Vinciguerra P, Ambr\u00f3sio R Jr, Roberts CJ, Elsheikh A. Ex-vivo experimental validation of biomechanically-corrected intraocular pressure measurements on human eyes using the CorVis ST. Exp Eye Res. 2018;175:98\u2013102.","journal-title":"Exp Eye Res"},{"issue":"4","key":"2620_CR36","doi-asserted-by":"publisher","first-page":"1762","DOI":"10.1177\/1120672120945664","volume":"31","author":"EA Abd El-Fattah","year":"2021","unstructured":"Abd El-Fattah EA, El Dorghamy AA, Ghoneim AM, Saad HA. Comparison of corneal biomechanical changes after LASIK and F-SMILE with CorVis ST. Eur J Ophthalmol. 2021;31(4):1762\u201370.","journal-title":"Eur J Ophthalmol"},{"issue":"7","key":"2620_CR37","doi-asserted-by":"publisher","first-page":"917","DOI":"10.3109\/02713683.2015.1082185","volume":"41","author":"SMM Sefat","year":"2016","unstructured":"Sefat SMM, Wiltfang R, Bechmann M, Mayer WJ, Kampik A, Kook D. Evaluation of Changes in Human Corneas After Femtosecond Laser-Assisted LASIK and Small-Incision Lenticule Extraction (SMILE) Using Non-Contact Tonometry and Ultra-High-Speed Camera (Corvis ST). Curr Eye Res. 2016;41(7):917\u201322.","journal-title":"Curr Eye Res"},{"issue":"3","key":"2620_CR38","first-page":"176","volume":"58","author":"Association PHOBoCPM","year":"2022","unstructured":"Association PHOBoCPM. Chinese expert consensus on prevention and control of COVID-19 eye disease (2022). Chin J Ophthalmol. 2022;58(3):176\u201381.","journal-title":"Chin J Ophthalmol"},{"issue":"1","key":"2620_CR39","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1007\/s42399-020-00633-1","volume":"3","author":"C Hoeferlin","year":"2021","unstructured":"Hoeferlin C, Hosseini H. Review of Clinical and Operative Recommendations for Ophthalmology Practices During the COVID-19 Pandemic. SN Comprehensive Clin Med. 2021;3(1):3\u20138.","journal-title":"SN Comprehensive Clin Med"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02620-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-022-02620-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02620-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T12:47:38Z","timestamp":1665406058000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-022-02620-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,10]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2620"],"URL":"https:\/\/doi.org\/10.1186\/s12886-022-02620-7","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10,10]]},"assertion":[{"value":"13 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 October 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Ethics Committee of West China Hospital of Sichuan University and was performed in accordance with the declaration of Helsinki. Informed consent was obtained from all subjects and\/or their legal guardian(s).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The author declares that there are no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"404"}}