{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T07:41:48Z","timestamp":1794642108254,"version":"4.9.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T00:00:00Z","timestamp":1670025600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T00:00:00Z","timestamp":1670025600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Shanghai Sailing Program","award":["20YF1405200"],"award-info":[{"award-number":["20YF1405200"]}]},{"DOI":"10.13039\/501100001809","name":"The National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82000932"],"award-info":[{"award-number":["82000932"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Project of Shanghai Science and Technology","award":["20410710100"],"award-info":[{"award-number":["20410710100"]}]},{"name":"Joint Research Project of New Frontier Technology in Municipal Hospitals","award":["SHDC12018103"],"award-info":[{"award-number":["SHDC12018103"]}]},{"name":"Clinical Research Plan of SHDC","award":["SHDC2020CR1043B"],"award-info":[{"award-number":["SHDC2020CR1043B"]}]},{"name":"Project of Shanghai Xuhui District Science and Technology","award":["2020-015"],"award-info":[{"award-number":["2020-015"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>To evaluate the accuracy of axial length, keratometry, and refractive measurement with Myopia Master in ametropic children.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this randomized prospective cross-sectional study, 125 children with ametropia (250 eyes) were recruited (55 boys and 70 girls; age range: 3\u201315\u00a0years). All examinations were performed under full cycloplegic conditions. Measurements of axial length (AL), keratometry, and autorefraction acquired with the Myopia Master were compared with those from the IOLMaster 500, IOLMaster 700, Nidek ARK-1, and manifest refraction. The differences between the different methods were analyzed, and their correlation was assessed by interclass correlation coefficients (ICCs), Bland\u2013Altman plot, and correlation test.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The ALs (mm) measured with Myopia Master, IOLMaster 500, and IOLMaster 700 were 23.67\u2009\u00b1\u20091.26, 23.68\u2009\u00b1\u20091.26, and 23.70\u2009\u00b1\u20091.25, respectively. The mean values and standard deviations for AL and keratometry readings from these devices were similar (<jats:italic>P<\/jats:italic>\u2009\u2265\u20090.059). The ICC analysis also revealed high consistency between the measurements (ICC\u2009\u2265\u20090.943). Additionally, the correlation coefficients were relatively high (<jats:italic>r<\/jats:italic>\u2009&gt;\u20090.9, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Although the results of refraction obtained with the Myopia Master were slightly higher than those with manifest refraction (<jats:italic>P<\/jats:italic>\u2009\u2264\u20090.024), the agreement between these two measurements was excellent (ICC\u2009\u2265\u20090.858). The percentage of points outside the limits of agreements was\u2009&lt;\u20095.22% in Bland\u2013Altman plots for all analyses.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Myopia Master could be a highly efficient tool for clinical use as a three-in-one system (AL, keratometry, and refractive measurements) for screening in children with ametropia.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-022-02672-9","type":"journal-article","created":{"date-parts":[[2022,12,3]],"date-time":"2022-12-03T11:02:49Z","timestamp":1670065369000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Accuracy of axial length, keratometry, and refractive measurement with Myopia Master in children with ametropia"],"prefix":"10.1186","volume":"22","author":[{"given":"Yuhao","family":"Ye","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tian","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huamao","family":"Miao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xingtao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,3]]},"reference":[{"issue":"1","key":"2672_CR1","doi-asserted-by":"publisher","first-page":"63","DOI":"10.2471\/BLT.07.041210","volume":"86","author":"S Resnikoff","year":"2008","unstructured":"Resnikoff S. Global magnitude of visual impairment caused by uncorrected refractive errors in 2004. B World Health Organ. 2008;86(1):63\u201370.","journal-title":"B World Health Organ"},{"issue":"4","key":"2672_CR2","doi-asserted-by":"publisher","first-page":"1492","DOI":"10.1167\/iovs.02-0816","volume":"44","author":"J Gwiazda","year":"2003","unstructured":"Gwiazda J, Hyman L, Hussein M, Everett D, Norton TT, Kurtz D, Leske MC, Manny R, Marsh-Tootle W, Scheiman M. A randomized clinical trial of progressive addition lenses versus single vision lenses on the progression of myopia in children. Invest Ophthalmol Vis Sci. 2003;44(4):1492\u2013500.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"6","key":"2672_CR3","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1046\/j.1475-1313.2001.00611.x","volume":"21","author":"AK Lam","year":"2001","unstructured":"Lam AK, Chan R, Pang PC. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt. 2001;21(6):477\u201383.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"6","key":"2672_CR4","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1097\/OPX.0000000000001386","volume":"96","author":"N Paudel","year":"2019","unstructured":"Paudel N, Adhikari S, Thakur A, Shrestha B, Loughman J. Clinical Accuracy of the Nidek ARK-1 Autorefractor. Optometry Vision Sci. 2019;96(6):407\u201313.","journal-title":"Optometry Vision Sci"},{"issue":"1","key":"2672_CR5","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1037\/1082-989X.1.1.30","volume":"1","author":"KO McGraw","year":"1996","unstructured":"McGraw KO, Wong SP. Forming inferences about some intraclass correlation coefficients. Psychol Methods. 1996;1(1):30\u201346.","journal-title":"Psychol Methods"},{"issue":"9","key":"2672_CR6","doi-asserted-by":"publisher","first-page":"1474","DOI":"10.1016\/j.jcrs.2010.02.027","volume":"36","author":"JH Shammas","year":"2010","unstructured":"Shammas JH, Chan S. Precision of biometry, keratometry, and refractive measurements with a partial coherence interferometry\u2013keratometry device. J Cataract Refr Surg. 2010;36(9):1474\u20138.","journal-title":"J Cataract Refr Surg"},{"key":"2672_CR7","doi-asserted-by":"publisher","first-page":"1961","DOI":"10.1016\/S0886-3350(01)01214-7","volume":"27","author":"ADHKF Vogel","year":"2001","unstructured":"Vogel ADHKF. Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability. J Cataract Refract Surg. 2001;27:1961\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"2672_CR8","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1136\/bjo.86.4.458","volume":"86","author":"J Santodomingo-Rubido","year":"2002","unstructured":"Santodomingo-Rubido J, Mallen EAH, Gilmartin B, Wolffsohn JS. A new non-contact optical device for ocular biometry. Brit J Ophthalmol. 2002;86(4):458\u201362.","journal-title":"Brit J Ophthalmol"},{"issue":"9","key":"2672_CR9","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s004170000188","volume":"238","author":"W Haigis","year":"2000","unstructured":"Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238(9):765\u201373.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"9","key":"2672_CR10","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","volume":"100","author":"A Akman","year":"2016","unstructured":"Akman A, Asena L, G\u00fcng\u00f6r SG. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500. Brit J Ophthalmol. 2016;100(9):1201\u20135.","journal-title":"Brit J Ophthalmol"},{"key":"2672_CR11","doi-asserted-by":"crossref","unstructured":"Kurian M, Negalur N, Das S, Puttaiah NK, Haria D, J TS, Thakkar MM. Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device. J Cataract Refract Surg. 2016;42(4):577-81.","DOI":"10.1016\/j.jcrs.2016.01.038"},{"issue":"2","key":"2672_CR12","doi-asserted-by":"publisher","first-page":"126","DOI":"10.3341\/kjo.2019.0102","volume":"34","author":"HS Jeon","year":"2020","unstructured":"Jeon HS, Hyon JY, Yoon DY. Comparison of Ocular Biometry and Refractive Outcomes Using IOL Master 500, IOL Master 700, and Lenstar LS900. Korean J Ophthalmol. 2020;34(2):126\u201332.","journal-title":"Korean J Ophthalmol"},{"key":"2672_CR13","doi-asserted-by":"crossref","unstructured":"Lee AC, Qazi MA, Pepose JS. Biometry and intraocular lens power calculation. Curr Opin Ophthalmol. 2008;19(1)13\u201317.","DOI":"10.1097\/ICU.0b013e3282f1c5ad"},{"issue":"8","key":"2672_CR14","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1016\/j.jcrs.2016.07.013","volume":"42","author":"KJ Hoffer","year":"2016","unstructured":"Hoffer KJ, Hoffmann PC, Savini G. Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry. J Cataract Refr Surg. 2016;42(8):1165\u201372.","journal-title":"J Cataract Refr Surg"},{"issue":"5","key":"2672_CR15","first-page":"705","volume":"39","author":"T Oshika","year":"1998","unstructured":"Oshika T, Tomidokoro A, Maruo K, Tokunaga T, Miyata N. Quantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data. Invest Ophth Vis Sci. 1998;39(5):705\u20139.","journal-title":"Invest Ophth Vis Sci"},{"issue":"2","key":"2672_CR16","doi-asserted-by":"publisher","first-page":"233","DOI":"10.4103\/0974-9233.151884","volume":"22","author":"Z Dehnavi","year":"2015","unstructured":"Dehnavi Z, Khabazkhoob M, Mirzajani A, Jabbarvand M, Yekta A, Jafarzadehpur E. Comparison of the Corneal Power Measurements with the TMS4-Topographer, Pentacam HR, IOL Master, and Javal Keratometer. Middle East Afr J Ophthalmol. 2015;22(2):233\u20137.","journal-title":"Middle East Afr J Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02672-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-022-02672-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02672-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,4]],"date-time":"2022-12-04T03:03:47Z","timestamp":1670123027000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-022-02672-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,3]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2672"],"URL":"https:\/\/doi.org\/10.1186\/s12886-022-02672-9","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,3]]},"assertion":[{"value":"12 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study followed the tenets of the Declaration of Helsinki and was approved by the ethics committee of the Eye and ENT Hospital of Fudan University (2020022, Date: 02\/02\/2020). Informed consent was obtained from all participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Patient names and the eyes\/facial region of study participants is not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"No conflicting relationship exists for any authors.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"468"}}