{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T05:22:28Z","timestamp":1780723348416,"version":"3.54.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,28]],"date-time":"2022-12-28T00:00:00Z","timestamp":1672185600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,28]],"date-time":"2022-12-28T00:00:00Z","timestamp":1672185600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>To ascertain the agreement of corneal aberrations obtained from the Pentacam and the KR-1W in myopic populations and to investigate the influence of the level of myopia as well as the laterality on the agreement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In this observational study, a rotating Scheimpflug camera (Pentacam AXL) and a Hartmann-Shack wavefront analyzer with Placido-disc topographer (KR-1W) were used to measure the aberrations of myopes in the anterior corneal surface by one experienced operator. All examinations were computed across a 6\u00a0mm diameter. Six subgroups were generated according to the degree of myopia (mild, moderate, and severe\u00a0myopia) and the laterality of eyes (right and left eyes).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The study included 245 eyes of 170 participants. For certain anterior corneal aberrations, statistically significant differences existed between the Pentacam and the KR-1W (all<jats:italic>P<\/jats:italic>\u2009&lt;\u2009.05). The values of Zernike (Z)(2,0), Z(2,2), Z(3,1), and Z(4,0) varied in all levels of myopia regardless of the laterality, with the values of the Pentacam constantly larger than the KR-1W in the measurement of Z(2,0), Z(2,2), and Z(4,0). For 2nd to 6th aberrations, both instruments correlated poorly to moderately. The width of limits of agreement between the two instruments was clinically too wide (&gt;\u20090.1\u00a0\u03bcm) for aberrations closely correlated with visual quality, including Z(3,\u2009\u00b1\u20093), Z(3,\u2009\u00b1\u20091), and Z(4,0), and almost all aberrations, indicating poor agreement.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>In clinical practice, the Pentacam based on Scheimpflug technology and the KR-1W based on Placido Disc System are not interchangeable in measuring anterior corneal aberration for myopes regardless of myopia degree and the laterality, suggesting that a consistent instrument should be selected for surgical design as well as follow-up.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12886-022-02753-9","type":"journal-article","created":{"date-parts":[[2022,12,28]],"date-time":"2022-12-28T17:03:23Z","timestamp":1672247003000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of anterior corneal aberrations measured by Scheimpflug and Placido Disc System for myopes"],"prefix":"10.1186","volume":"22","author":[{"given":"Wei","family":"Lou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haiying","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ying","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,12,28]]},"reference":[{"issue":"1","key":"2753_CR1","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.jcrs.2018.08.026","volume":"45","author":"A Gyldenkerne","year":"2019","unstructured":"Gyldenkerne A, Ivarsen A, Hjortdal J. Optical and visual quality after small-incision lenticule extraction. J Cataract Refract Surg. 2019;45(1):54\u201361.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"2753_CR2","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1080\/02713683.2019.1622019","volume":"44","author":"X Liao","year":"2019","unstructured":"Liao X, Lin J, Tan Q, Wen B, Tian J, Lan C. Evaluation of Visual Quality in Pseudophakic Eyes with Different Ocular Spherical Aberrations. Curr Eye Res. 2019;44(9):963\u20137.","journal-title":"Curr Eye Res"},{"key":"2753_CR3","doi-asserted-by":"crossref","unstructured":"Goto S, Maeda N. Corneal topography for intraocular lens selection in refractive cataract surgery. Ophthalmology.\u00a02021;128(11):e142\u201352.","DOI":"10.1016\/j.ophtha.2020.11.016"},{"issue":"4","key":"2753_CR4","doi-asserted-by":"publisher","first-page":"302","DOI":"10.1007\/s10384-016-0449-x","volume":"60","author":"K Kamiya","year":"2016","unstructured":"Kamiya K, Shimizu K, Miyake T. Changes in astigmatism and corneal higher-order aberrations after phacoemulsification with toric intraocular lens implantation for mild keratoconus with cataract. Jpn J Ophthalmol. 2016;60(4):302\u20138.","journal-title":"Jpn J Ophthalmol"},{"issue":"10","key":"2753_CR5","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1097\/OPX.0000000000001435","volume":"96","author":"NK Singh","year":"2019","unstructured":"Singh NK, Jaskulski M, Ramasubramanian V, Meyer D, Reed O, Rickert ME, Bradley A, Kollbaum PS. Validation of a clinical aberrometer using pyramidal wavefront sensing. Optom Vis Sci. 2019;96(10):733\u201344.","journal-title":"Optom Vis Sci"},{"issue":"6","key":"2753_CR6","doi-asserted-by":"publisher","first-page":"2864","DOI":"10.3390\/tomography8060240","volume":"8","author":"A Salman","year":"2022","unstructured":"Salman A, Kailani O, Marshall J, Ghabra M, Balamoun AA, Darwish TR, Badla AA, Alhaji H. Evaluation of anterior and posterior corneal higher order aberrations for the detection of Keratoconus and suspect keratoconus. Tomography. 2022;8(6):2864\u201373.","journal-title":"Tomography"},{"key":"2753_CR7","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.ajo.2020.06.013","volume":"219","author":"EO Kreps","year":"2020","unstructured":"Kreps EO, Jimenez-Garcia M, Issarti I, Claerhout I, Koppen C, Rozema JJ. Repeatability of the Pentacam HR in Various Grades of Keratoconus. Am J Ophthalmol. 2020;219:154\u201362.","journal-title":"Am J Ophthalmol"},{"issue":"12","key":"2753_CR8","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.1136\/bjophthalmol-2018-312333","volume":"102","author":"S Koh","year":"2018","unstructured":"Koh S, Tung CI, Inoue Y, Jhanji V. Effects of tear film dynamics on quality of vision. Br J Ophthalmol. 2018;102(12):1615\u201320.","journal-title":"Br J Ophthalmol"},{"issue":"1","key":"2753_CR9","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1007\/s00417-019-04504-x","volume":"258","author":"L Batres","year":"2020","unstructured":"Batres L, Peruzzo S, Serramito M, Carracedo G. Accommodation response and spherical aberration during orthokeratology. Graefe\u2019s Arch Clin Exp ophthalmol. 2020;258(1):117\u201327.","journal-title":"Graefe's Arch Clin Exp ophthalmol"},{"issue":"8","key":"2753_CR10","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1097\/ICO.0000000000001959","volume":"38","author":"N Telinius","year":"2019","unstructured":"Telinius N, Ott P, Sandahl T, Hjortdal J. Scheimpflug imaging of the Danish cohort of patients with Wilson disease. Cornea. 2019;38(8):998\u20131002.","journal-title":"Cornea"},{"issue":"7","key":"2753_CR11","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1111\/aos.13183","volume":"94","author":"A Fredriksson","year":"2016","unstructured":"Fredriksson A, Behndig A. Eccentric small-zone ray tracing wavefront aberrometry for refraction in keratoconus. Acta Ophthalmol. 2016;94(7):679\u201384.","journal-title":"Acta Ophthalmol"},{"issue":"7","key":"2753_CR12","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1097\/j.jcrs.0000000000000550","volume":"47","author":"S Georgiev","year":"2021","unstructured":"Georgiev S, Hirnschall N, Fi\u015fu\u015f AD, Ruiss M, Hienert J, Leisser C, Findl O. Repeatability of intraoperative Hartmann-Shack wavefront sensing in cataract surgery. J Cataract Refract Surg. 2021;47(7):902\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"2753_CR13","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.jcrs.2018.11.015","volume":"45","author":"AL Piccinini","year":"2019","unstructured":"Piccinini AL, Golan O, Hafezi F, Randleman JB. Higher-order aberration measurements: comparison between Scheimpflug and dual Scheimpflug-placido technology in normal eyes. J Cataract Refract Surg. 2019;45(4):490\u20134.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"2753_CR14","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.4103\/ijo.IJO_1464_18","volume":"67","author":"WH Cook","year":"2019","unstructured":"Cook WH, McKelvie J, Wallace HB, Misra SL. Comparison of higher order wavefront aberrations with four aberrometers. Indian J Ophthalmol. 2019;67(7):1030\u20135.","journal-title":"Indian J Ophthalmol"},{"issue":"2","key":"2753_CR15","first-page":"292","volume":"9","author":"J Hao","year":"2016","unstructured":"Hao J, Li L, Tian F, Zhang H. Comparison of two types of visual quality analyzer for the measurement of high order aberrations. Int J Ophthalmol. 2016;9(2):292\u20137.","journal-title":"Int J Ophthalmol"},{"issue":"1","key":"2753_CR16","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s12886-018-0683-8","volume":"18","author":"Z Xu","year":"2018","unstructured":"Xu Z, Hua Y, Qiu W, Li G, Wu Q. Precision and agreement of higher order aberrations measured with ray tracing and Hartmann-Shack aberrometers. BMC Ophthalmol. 2018;18(1):18.","journal-title":"BMC Ophthalmol"},{"issue":"2","key":"2753_CR17","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.jcrs.2012.08.061","volume":"39","author":"A L\u00f3pez-Miguel","year":"2013","unstructured":"L\u00f3pez-Miguel A, Mart\u00ednez-Almeida L, Gonz\u00e1lez-Garc\u00eda MJ, Coco-Mart\u00edn MB, Sobrado-Calvo P, Maldonado MJ. Precision of higher-order aberration measurements with a new Placido-disk topographer and Hartmann-Shack wavefront sensor. J Cataract Refract Surg. 2013;39(2):242\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"2753_CR18","doi-asserted-by":"publisher","first-page":"509","DOI":"10.3928\/1081597X-20101214-01","volume":"27","author":"DP Pi\u00f1ero","year":"2011","unstructured":"Pi\u00f1ero DP, Juan JT, Ali\u00f3 JL. Intrasubject repeatability of internal aberrometry obtained with a new integrated aberrometer. J Refract Surg. 2011;27(7):509\u201317 (Thorofare, NJ\u202f: 1995).","journal-title":"J Refract Surg"},{"issue":"4","key":"2753_CR19","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1097\/j.jcrs.0000000000000084","volume":"46","author":"C McAlinden","year":"2020","unstructured":"McAlinden C, Schwiegerling J, Khadka J, Pesudovs K. Corneal aberrations measured with a high-resolution Scheimpflug tomographer: repeatability and reproducibility. J Cataract Refract Surg. 2020;46(4):581\u201390.","journal-title":"J Cataract Refract Surg"},{"key":"2753_CR20","doi-asserted-by":"crossref","unstructured":"Shetty R, Trivedi D, Ranade R, Arun S, Khamar P, Kundu G. Repeatability and agreement of wavefront aberrations of pentacam AXL wave- a new hybrid topographer and aberrometer with ITrace in healthy eyes. J Cataract Refract Surg. 2021.","DOI":"10.1097\/j.jcrs.0000000000000775"},{"key":"2753_CR21","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s12886-016-0184-6","volume":"16","author":"H Song","year":"2016","unstructured":"Song H, Yuan X, Tang X. Effects of intraocular lenses with different diopters on chromatic aberrations in human eye models. BMC Ophthalmol. 2016;16:9.","journal-title":"BMC Ophthalmol"},{"key":"2753_CR22","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.ajo.2016.04.011","volume":"167","author":"S Klijn","year":"2016","unstructured":"Klijn S, Reus NJ, van der Sommen CM, Sicam VA. Accuracy of Total Corneal Astigmatism Measurements With a Scheimpflug imager and a color light-emitting diode corneal topographer. Am J Ophthalmol. 2016;167:72\u20138.","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"2753_CR23","doi-asserted-by":"publisher","first-page":"249","DOI":"10.3928\/1081597X-20150212-01","volume":"31","author":"S Klijn","year":"2015","unstructured":"Klijn S, Reus NJ, Sicam VA. Evaluation of keratometry with a novel color-LED corneal topographer. J Refract Surg. 2015;31(4):249\u201356 (Thorofare, NJ\u202f: 1995).","journal-title":"J Refract Surg"},{"key":"2753_CR24","doi-asserted-by":"publisher","unstructured":"Hwang Y, Kim DY, Chung H. Comparison between color light\u2010emitting diode corneal topographer and scheimpflug imager in measuring corneal astigmatism and corneal higher order aberrations.\u00a0Acta Ophthalmol (1755375X).\u00a02019;97(S263). https:\/\/doi.org\/10.1111\/j.1755-3768.2019.5189.","DOI":"10.1111\/j.1755-3768.2019.5189"},{"issue":"7","key":"2753_CR25","first-page":"515","volume":"55","author":"ZY Wang","year":"2019","unstructured":"Wang ZY, Yang WL, Li DJ, Chen W, Zhao Q, Li YF, Cui R, Shen L, Xian JF. Comparison of biometry with the Pentacam AXL, IOLMaster 700 and IOLMaster 500 in cataract patients]. [Zhonghua yan ke za zhi] Chin J Ophthalmol. 2019;55(7):515\u201321.","journal-title":"[Zhonghua yan ke za zhi] Chin J Ophthalmol"},{"key":"2753_CR26","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ajo.2017.02.027","volume":"178","author":"M Shajari","year":"2017","unstructured":"Shajari M, Cremonese C, Petermann K, Singh P, M\u00fcller M, Kohnen T. Comparison of axial length, corneal curvature, and anterior chamber depth measurements of 2 recently introduced devices to a known biometer. Am J Ophthalmol. 2017;178:58\u201364.","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"2753_CR27","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1038\/s41598-021-81146-2","volume":"11","author":"HA Arruda","year":"2021","unstructured":"Arruda HA, Pereira JM, Neves A, Vieira MJ, Martins J, Sousa JC. Lenstar LS 900 versus pentacam-AXL: analysis of refractive outcomes and predicted refraction. Sci Rep. 2021;11(1):1449.","journal-title":"Sci Rep"},{"key":"2753_CR28","doi-asserted-by":"publisher","first-page":"3487","DOI":"10.2147\/OPTH.S278701","volume":"14","author":"C Supiyaphun","year":"2020","unstructured":"Supiyaphun C, Rattanasiri S, Jongkhajornpong P. Comparison of anterior segment parameters and axial length using two Scheimpflug devices with integrated optical biometers. Clin Ophthalmol (Auckland, NZ). 2020;14:3487\u201394.","journal-title":"Clin Ophthalmol (Auckland, NZ)"},{"issue":"9","key":"2753_CR29","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.1007\/s10792-018-1028-6","volume":"39","author":"I Almor\u00edn-Fern\u00e1ndez-Vigo","year":"2019","unstructured":"Almor\u00edn-Fern\u00e1ndez-Vigo I, S\u00e1nchez-Guill\u00e9n I, Fern\u00e1ndez-Vigo JI, Macarro-Merino A, Kudsieh B, Fern\u00e1ndez-Vigo C, Fern\u00e1ndez-Vigo JA. Normative Pentacam anterior and posterior corneal elevation measurements: effects of age, sex, axial length and white-to-white. Int Ophthalmol. 2019;39(9):1955\u201363.","journal-title":"Int Ophthalmol"},{"issue":"9","key":"2753_CR30","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1097\/j.jcrs.0000000000000237","volume":"46","author":"MA Henriquez","year":"2020","unstructured":"Henriquez MA, Z\u00fa\u00f1iga R, Camino M, Camargo J, Ruiz-Montenegro K, Izquierdo L Jr. Effectiveness and agreement of 3 optical biometers in measuring axial length in the eyes of patients with mature cataracts. J Cataract Refract Surg. 2020;46(9):1222\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"2753_CR31","doi-asserted-by":"publisher","first-page":"1896","DOI":"10.1016\/S0886-3350(03)00643-6","volume":"29","author":"L Wang","year":"2003","unstructured":"Wang L, Koch DD. Ocular higher-order aberrations in individuals screened for refractive surgery. J Cataract Refract Surg. 2003;29(10):1896\u2013903.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"2753_CR32","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0054990","volume":"8","author":"F Cade","year":"2013","unstructured":"Cade F, Cruzat A, Paschalis EI, Esp\u00edrito Santo L, Pineda R. Analysis of four aberrometers for evaluating lower and higher order aberrations. PLoS ONE. 2013;8(1): e54990.","journal-title":"PLoS ONE"},{"issue":"3","key":"2753_CR33","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1167\/iovs.10-5841","volume":"52","author":"N Visser","year":"2011","unstructured":"Visser N, Berendschot TT, Verbakel F, Tan AN, de Brabander J, Nuijts RM. Evaluation of the comparability and repeatability of four wavefront aberrometers. Invest Ophthalmol Vis Sci. 2011;52(3):1302\u201311.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"6","key":"2753_CR34","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1016\/j.jcrs.2009.01.020","volume":"35","author":"SA Read","year":"2009","unstructured":"Read SA, Collins MJ, Iskander DR, Davis BA. Corneal topography with Scheimpflug imaging and videokeratography: comparative study of normal eyes. J Cataract Refract Surg. 2009;35(6):1072\u201381.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"2753_CR35","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1167\/iovs.07-0762","volume":"49","author":"S Koh","year":"2008","unstructured":"Koh S, Maeda N, Hirohara Y, Mihashi T, Bessho K, Hori Y, Inoue T, Watanabe H, Fujikado T, Tano Y. Serial measurements of higher-order aberrations after blinking in patients with dry eye. Invest Ophthalmol Vis Sci. 2008;49(1):133\u20138.","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02753-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-022-02753-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-022-02753-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,3]],"date-time":"2023-12-03T17:10:59Z","timestamp":1701623459000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-022-02753-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,28]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2753"],"URL":"https:\/\/doi.org\/10.1186\/s12886-022-02753-9","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,28]]},"assertion":[{"value":"19 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the local ethics institution of Shanghai Sixth People\u2019s Hospital. All procedures strictly adhered to the tenets of the Declaration of Helsinki. A written informed consent was obtained from all participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no proprietary or financial interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"512"}}