{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:31:31Z","timestamp":1787020291708,"version":"build-2736575974"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T00:00:00Z","timestamp":1675036800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T00:00:00Z","timestamp":1675036800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The design of cap thickness for small incision lenticule extraction (SMILE) plays a role in post-laser vision correction (post-LVC) corneal biomechanics. This study aimed to compare the corneal biomechanical characteristics following SMILE with different cap thicknesses of 110\u2009\u03bcm, 120\u2009\u03bcm, and 130\u2009\u03bcm for myopia and myopic astigmatism correction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Seventy-five patients (146 eyes) who underwent SMILE with designed cap thickness of 110\u2009\u03bcm, 120\u2009\u03bcm, and 130\u2009\u03bcm were recruited at the Eye Center of Beijing Tongren Hospital between August 2020 and November 2021. Visual acuity, refraction, and corneal biomechanical parameters were measured preoperatively, 1\u2009week and 1, 3, 6\u2009months postoperatively. One-way analysis of variances (ANOVA) with Bonferroni correction or Kruskal-Wallis test was performed to compare the parameters among different groups. Repeated-measures analysis of variance with Bonferroni correction or Friedman test was applied for comparing the parameters within different follow-up times.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Uncorrected distance visual acuity of 110-\u03bcm group was better only at 1-week and 1-month postoperatively (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.012, 0.037). There were no significant differences in spherical equivalent, nor in Corvis biomechanical index-laser vision correction (CBI-LVC). All the parameters reached stability at 3-month postoperatively. Integrated radius (IR) and deformation amplitude ratio 2\u2009mm (DA ratio 2\u2009mm) in 120-\u03bcm and 130-\u03bcm groups were higher than 110-\u03bcm group at 1-month postoperatively (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.019, 0.002). So was Ambr\u00f3sio relational thickness (ARTh) at 6-month postoperatively (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.011). Stiffness parameter at applanation A1 (SP-A1), stress-strain index (SSI), biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT) were highest in 130-\u03bcm group, followed by 120-\u03bcm group, then 110-\u03bcm group at 3-month (\n                      <jats:italic>P<\/jats:italic>\n                      &lt;0.001,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.030,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.027,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.008) and 6-month (\n                      <jats:italic>P<\/jats:italic>\n                      &lt;0.001,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.002,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.0023,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.001) postoperatively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The corneal stiffness following SMILE was greatest with 130-\u03bcm cap, followed by 120-\u03bcm cap, then 110-\u03bcm cap. 130-\u03bcm cap might have advantages in terms of corneal biomechanics and retreatment option. The SMILE-designed protocol should be customized in practice.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-023-02786-8","type":"journal-article","created":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T05:04:04Z","timestamp":1675055044000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses"],"prefix":"10.1186","volume":"23","author":[{"given":"Xiaotong","family":"Lv","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fengju","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanzheng","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changbin","family":"Zhai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ning","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingbo","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yushan","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,30]]},"reference":[{"issue":"10185","key":"2786_CR1","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/S0140-6736(18)33209-4","volume":"393","author":"TI Kim","year":"2019","unstructured":"Kim TI, Alio Del Barrio JL, Wilkins M, Cochener B, Ang M. Refractive surgery. Lancet. 2019;393(10185):2085\u201398.","journal-title":"Lancet"},{"issue":"3","key":"2786_CR2","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1016\/j.jcrs.2015.02.006","volume":"41","author":"M Moshirfar","year":"2015","unstructured":"Moshirfar M, McCaughey MV, Reinstein DZ, Shah R, Santiago-Caban L, Fenzl CR. Small-incision lenticule extraction. J Cataract Refract Surg. 2015;41(3):652\u201365.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"2786_CR3","first-page":"456","volume":"6","author":"GK Marino","year":"2017","unstructured":"Marino GK, Santhiago MR, Wilson SE. Femtosecond lasers and corneal surgical procedures. Asia Pac J Ophthalmol (Phila). 2017;6(5):456\u201364.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"4","key":"2786_CR4","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.exer.2006.03.015","volume":"83","author":"WJ Dupps Jr","year":"2006","unstructured":"Dupps WJ Jr, Wilson SE. Biomechanics and wound healing in the cornea. Exp Eye Res. 2006;83(4):709\u201320.","journal-title":"Exp Eye Res"},{"key":"2786_CR5","doi-asserted-by":"publisher","first-page":"108347","DOI":"10.1016\/j.exer.2020.108347","volume":"202","author":"MQ Salomao","year":"2021","unstructured":"Salomao MQ, Hofling-Lima AL, Gomes Esporcatte LP, Correa FF, Lopes B, Sena N Jr, et al. Ectatic diseases. Exp Eye Res. 2021;202:108347.","journal-title":"Exp Eye Res"},{"key":"2786_CR6","doi-asserted-by":"publisher","first-page":"176","DOI":"10.2174\/1874364101711010176","volume":"11","author":"R Ambrosio Jr","year":"2017","unstructured":"Ambrosio R Jr, Correia FF, Lopes B, Salomao MQ, Luz A, Dawson DG, et al. Corneal biomechanics in Ectatic diseases: refractive surgery implications. Open Ophthalmol J. 2017;11:176\u201393.","journal-title":"Open Ophthalmol J"},{"key":"2786_CR7","doi-asserted-by":"publisher","first-page":"108508","DOI":"10.1016\/j.exer.2021.108508","volume":"205","author":"J Chong","year":"2021","unstructured":"Chong J, Dupps WJ Jr. Corneal biomechanics: measurement and structural correlations. Exp Eye Res. 2021;205:108508.","journal-title":"Exp Eye Res"},{"issue":"1","key":"2786_CR8","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1159\/000520241","volume":"65","author":"C Liang","year":"2022","unstructured":"Liang C, Zhang Y, He Y, Wang S. Research Progress on morphological changes and surgery-related parameters of corneal cap in small-incision lenticule extraction. Ophthalmic Res. 2022;65(1):4\u201313.","journal-title":"Ophthalmic Res"},{"issue":"1","key":"2786_CR9","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ophtha.2007.03.073","volume":"115","author":"JB Randleman","year":"2008","unstructured":"Randleman JB, Woodward M, Lynn MJ, Stulting RD. Risk assessment for ectasia after corneal refractive surgery. Ophthalmology. 2008;115(1):37\u201350.","journal-title":"Ophthalmology"},{"key":"2786_CR10","doi-asserted-by":"publisher","first-page":"1685","DOI":"10.2147\/OPTH.S157172","volume":"12","author":"JS Titiyal","year":"2018","unstructured":"Titiyal JS, Kaur M, Shaikh F, Gagrani M, Brar AS, Rathi A. Small incision lenticule extraction (SMILE) techniques: patient selection and perspectives. Clin Ophthalmol. 2018;12:1685\u201399.","journal-title":"Clin Ophthalmol"},{"issue":"9","key":"2786_CR11","doi-asserted-by":"publisher","first-page":"e0163259","DOI":"10.1371\/journal.pone.0163259","volume":"11","author":"M He","year":"2016","unstructured":"He M, Wang W, Ding H, Zhong X. Comparison of two cap thickness in small incision lenticule extraction: 100 \u03bcm versus 160 \u03bcm. PLoS One. 2016;11(9):e0163259.","journal-title":"PLoS One"},{"issue":"5","key":"2786_CR12","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1167\/iovs.17-23675","volume":"59","author":"IB Damgaard","year":"2018","unstructured":"Damgaard IB, Ivarsen A, Hjortdal J. Refractive correction and biomechanical strength following SMILE with a 110- or 160-\u03bcm cap thickness, evaluated ex vivo by inflation test. Invest Ophthalmol Vis Sci. 2018;59(5):1836\u201343.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"2786_CR13","doi-asserted-by":"publisher","first-page":"6040873","DOI":"10.1155\/2018\/6040873","volume":"2018","author":"T Liu","year":"2018","unstructured":"Liu T, Yu T, Liu L, Chen K, Bai J. Corneal cap thickness and its effect on visual acuity and corneal biomechanics in eyes undergoing small incision lenticule extraction. J Ophthalmol. 2018;2018:6040873.","journal-title":"J Ophthalmol"},{"issue":"5","key":"2786_CR14","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1097\/ICO.0000000000001835","volume":"38","author":"F Wu","year":"2019","unstructured":"Wu F, Yin H, Yang Y. Contralateral eye comparison between 2 cap thicknesses in small incision lenticule extraction: 110 versus 130 \u03bcm. Cornea. 2019;38(5):617\u201323.","journal-title":"Cornea"},{"issue":"2","key":"2786_CR15","doi-asserted-by":"publisher","first-page":"82","DOI":"10.3928\/1081597X-20191216-01","volume":"36","author":"D Wu","year":"2020","unstructured":"Wu D, Liu C, Li B, Wang D, Fang X. Influence of cap thickness on corneal curvature and corneal biomechanics after SMILE: a prospective, contralateral eye study. J Refract Surg. 2020;36(2):82\u20138.","journal-title":"Contralateral Eye Study J Refract Surg"},{"issue":"8","key":"2786_CR16","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1167\/tvst.10.8.15","volume":"10","author":"I Jun","year":"2021","unstructured":"Jun I, Kang DSY, Roberts CJ, Lee H, Jean SK, Kim EK, et al. Comparison of clinical and biomechanical outcomes of small incision lenticule extraction with 120- and 140-micron cap thickness. Transl Vis Sci Technol. 2021;10(8):15.","journal-title":"Transl Vis Sci Technol"},{"issue":"5","key":"2786_CR17","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1097\/APO.0000000000000259","volume":"8","author":"J Siedlecki","year":"2019","unstructured":"Siedlecki J, Luft N, Priglinger SG, Dirisamer M. Enhancement options after myopic small-incision lenticule extraction (SMILE): a review. Asia Pac J Ophthalmol (Phila). 2019;8(5):406\u201311.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"5","key":"2786_CR18","doi-asserted-by":"publisher","first-page":"294","DOI":"10.3928\/1081597X-20190416-02","volume":"35","author":"J Siedlecki","year":"2019","unstructured":"Siedlecki J, Siedlecki M, Luft N, Kook D, Meyer B, Bechmann M, et al. Surface ablation versus CIRCLE for myopic enhancement after SMILE: a matched comparative study. J Refract Surg. 2019;35(5):294\u2013300.","journal-title":"J Refract Surg"},{"issue":"11","key":"2786_CR19","doi-asserted-by":"publisher","first-page":"1384","DOI":"10.1016\/j.jcrs.2018.07.047","volume":"44","author":"M Moshirfar","year":"2018","unstructured":"Moshirfar M, Shah TJ, Masud M, Linn SH, Ronquillo Y, Hoopes PC Sr. Surgical options for retreatment after small-incision lenticule extraction: advantages and disadvantages. J Cataract Refract Surg. 2018;44(11):1384\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"2786_CR20","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1097\/OPX.0b013e3181981b7e","volume":"86","author":"SA Read","year":"2009","unstructured":"Read SA, Collins MJ. Diurnal variation of corneal shape and thickness. Optom Vis Sci. 2009;86(3):170\u201380.","journal-title":"Optom Vis Sci"},{"issue":"10","key":"2786_CR21","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1097\/j.jcrs.0000000000000629","volume":"47","author":"R Vinciguerra","year":"2021","unstructured":"Vinciguerra R, Ambrosio R Jr, Elsheikh A, Hafezi F, Yong Kang DS, Kermani O, et al. Detection of post-laser vision correction ectasia with a new combined biomechanical index. J Cataract Refract Surg. 2021;47(10):1314\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"2786_CR22","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1097\/j.jcrs.0000000000000909","volume":"48","author":"NJ Lu","year":"2022","unstructured":"Lu NJ, Hafezi F, Rozema JJ, Hillen M, Hafezi N, Zhang J, et al. Repeatability of Corvis ST to measure biomechanical parameters before and after myopic refractive surgery. J Cataract Refract Surg. 2022;48(9):1057\u201362.","journal-title":"J Cataract Refract Surg"},{"key":"2786_CR23","doi-asserted-by":"publisher","first-page":"105","DOI":"10.3389\/fbioe.2019.00105","volume":"7","author":"A Eliasy","year":"2019","unstructured":"Eliasy A, Chen KJ, Vinciguerra R, Lopes BT, Abass A, Vinciguerra P, et al. Determination of corneal biomechanical behavior in-vivo for healthy eyes using CorVis ST tonometry: stress-strain index. Front Bioeng Biotechnol. 2019;7:105.","journal-title":"Front Bioeng Biotechnol"},{"issue":"4","key":"2786_CR24","doi-asserted-by":"publisher","first-page":"266","DOI":"10.3928\/1081597X-20161221-03","volume":"33","author":"CJ Roberts","year":"2017","unstructured":"Roberts CJ, Mahmoud AM, Bons JP, Hossain A, Elsheikh A, Vinciguerra R, et al. Introduction of two novel stiffness parameters and interpretation of air puff-induced biomechanical deformation parameters with a dynamic Scheimpflug analyzer. J Refract Surg. 2017;33(4):266\u201373.","journal-title":"J Refract Surg"},{"issue":"6","key":"2786_CR25","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.jcrs.2017.03.038","volume":"43","author":"N Luft","year":"2017","unstructured":"Luft N, Priglinger SG, Ring MH, Mayer WJ, Mursch-Edlmayr AS, Kreutzer TC, et al. Stromal remodeling and lenticule thickness accuracy in small-incision lenticule extraction: one-year results. J Cataract Refract Surg. 2017;43(6):812\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"2786_CR26","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1097\/j.jcrs.0000000000000242","volume":"46","author":"MV Olsen","year":"2020","unstructured":"Olsen MV, Lyngstadaas AV, Zhou W, Stojanovic A, Utheim TP, Wang X, et al. Temporal redistribution of cap and residual stromal thickness after SMILE. J Cataract Refract Surg. 2020;46(10):1331\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"2786_CR27","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1080\/02713683.2018.1532011","volume":"44","author":"D Wang","year":"2019","unstructured":"Wang D, Li Y, Sun M, Guo N, Zhang F. Lenticule thickness accuracy and influence in predictability and stability for different refractive errors after SMILE in Chinese myopic eyes. Curr Eye Res. 2019;44(1):96\u2013101.","journal-title":"Curr Eye Res"},{"issue":"12","key":"2786_CR28","doi-asserted-by":"publisher","first-page":"803","DOI":"10.3928\/1081597X-20160629-01","volume":"32","author":"R Vinciguerra","year":"2016","unstructured":"Vinciguerra R, Ambrosio R Jr, Elsheikh A, Roberts CJ, Lopes B, Morenghi E, et al. Detection of keratoconus with a new biomechanical index. J Refract Surg. 2016;32(12):803\u201310.","journal-title":"J Refract Surg"},{"issue":"8","key":"2786_CR29","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1016\/j.ophtha.2020.01.010","volume":"127","author":"JG Dishler","year":"2020","unstructured":"Dishler JG, Slade S, Seifert S, Schallhorn SC. Small-incision lenticule extraction (SMILE) for the correction of myopia with astigmatism: outcomes of the United States Food and Drug Administration premarket approval clinical trial. Ophthalmology. 2020;127(8):1020\u201334.","journal-title":"Ophthalmology"},{"issue":"11","key":"2786_CR30","doi-asserted-by":"publisher","first-page":"975","DOI":"10.3928\/1081597X-20091016-01","volume":"25","author":"DZ Reinstein","year":"2009","unstructured":"Reinstein DZ, Waring GO 3rd. Graphic reporting of outcomes of refractive surgery. J Refract Surg. 2009;25(11):975\u20138.","journal-title":"J Refract Surg"},{"issue":"1","key":"2786_CR31","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1097\/ICO.0000000000001404","volume":"37","author":"S Weng","year":"2018","unstructured":"Weng S, Liu M, Yang X, Liu F, Zhou Y, Lin H, et al. Evaluation of human corneal lenticule quality after SMILE with different cap thicknesses using scanning Electron microscopy. Cornea. 2018;37(1):59\u201365.","journal-title":"Cornea"},{"issue":"2 Suppl","key":"2786_CR32","first-page":"S204","volume":"14","author":"P Vinciguerra","year":"1998","unstructured":"Vinciguerra P, Azzolini M, Radice P, Sborgia M, De Molfetta V. A method for examining surface and interface irregularities after photorefractive keratectomy and laser in situ keratomileusis: predictor of optical and functional outcomes. J Refract Surg. 1998;14(2 Suppl):S204\u20136.","journal-title":"J Refract Surg"},{"issue":"1","key":"2786_CR33","doi-asserted-by":"publisher","first-page":"P170","DOI":"10.1016\/j.ophtha.2018.10.021","volume":"126","author":"FJ Garcia-Ferrer","year":"2019","unstructured":"Garcia-Ferrer FJ, Akpek EK, Amescua G, Farid M, Lin A, Rhee MK, et al. Corneal ectasia preferred practice pattern(R). Ophthalmology. 2019;126(1):P170\u2013215.","journal-title":"Ophthalmology"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-023-02786-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-023-02786-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-023-02786-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,30]],"date-time":"2023-01-30T05:10:45Z","timestamp":1675055445000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-023-02786-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,30]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["2786"],"URL":"https:\/\/doi.org\/10.1186\/s12886-023-02786-8","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,30]]},"assertion":[{"value":"19 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted in compliance with the Declaration of Helsinki and was approved by the ethics committee of Beijing Tongren Hospital affiliated to Capital Medical University. Informed consent was obtained from all patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"42"}}