{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T14:43:23Z","timestamp":1787496203792,"version":"build-2736575974"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T00:00:00Z","timestamp":1679875200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T00:00:00Z","timestamp":1679875200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Current intraocular pressure (IOP) measurements based on non-contact tonometry are derived from statistics-driven equations and lack biomechanical significance, which often leads to under-estimation in post-refractive surgery cornea. This study aims to introduce and validate modal analysis-derived intraocular pressure (mIOP) as a novel method generated through Legendre-based modal decomposition of the anterior corneal contour; it provides an accurate and intuitive IOP measurement from an energy-based perspective.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This retrospective study included 680 patients. Healthy participants were divided into reference (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009385) and validation (\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u2009142) datasets, and the others underwent either femtosecond-assisted laser in situ keratomileusis (FS-LASIK,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200958) or transepithelial photorefractive keratectomy (TPRK,\n                      <jats:italic>n<\/jats:italic>\n                      \u2009=\u200955). Corneal curvature of the right eyes was extracted from raw serial cross-sectional images of the cornea generated by Corvis ST, a noncontact tonometer with a high-speed Scheimpflug-camera. Legendre expansion was then applied to the corneal curvature to obtain the modal profiles (i.e., temporal changes of the coefficient for each basis polynomial [modes]). Using the reference dataset, feature selection on the modal profiles generated a final mIOP model consisting of a single parameter: total area under curve (frames 1\u2013140) divided by the area under curve of the rising phase (frames 24\u201340) in the fourth mode, i.e. the M\n                      <jats:sub>4<\/jats:sub>\n                      ratio. Validation was performed in both the healthy validation and postoperative datasets. IOP-Corvis, pachymetry-corrected IOP, biomechanically corrected IOP, and mIOP values were compared. For the FS-LASIK and TPRK groups, pairwise postoperative IOP changes were analyzed through repeated measures analysis of variance, and agreement was examined through Bland\u2013Altman analysis. Using a finite element analysis based three-dimensional model of the human cornea, we further compared the M\n                      <jats:sub>4<\/jats:sub>\n                      ratio with the true intraocular pressure within the physiological range.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The M\n                      <jats:sub>4<\/jats:sub>\n                      ratio-based mIOP demonstrated weak to negligible association with age, radius of corneal curvature, and central corneal thickness (CCT) in all validation analyses, and performed comparably with biomechanically corrected IOP (bIOP) in the refractive surgery groups. Both remained nearly constant postoperatively and were not influenced by CCT changes. Additionally, M\n                      <jats:sub>4<\/jats:sub>\n                      ratio accurately represented true intraocular pressure in the in silico model.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>mIOP is a reliable IOP measurement in healthy and postrefractive surgery populations. This energy-based, ratio-derived approach effectively filters out pathological, rotational, misaligned movements and serves as an interpatient self-calibration index. Modal analysis of corneal deformation dynamics provides novel insights into regional corneal responses against pressure loading.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-023-02867-8","type":"journal-article","created":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T08:03:26Z","timestamp":1679904206000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Development and validation of an intuitive biomechanics-based method for intraocular pressure measurement: a modal analysis approach"],"prefix":"10.1186","volume":"23","author":[{"given":"Francis Li-Tien","family":"Hsu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Po-Jen","family":"Shih","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I.-Jong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,27]]},"reference":[{"issue":"1","key":"2867_CR1","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1001\/archopht.121.1.48","volume":"121","author":"MC Leske","year":"2003","unstructured":"Leske MC, Heijl A, Hussein M, Bengtsson B, Hyman L, Komaroff E, et al. Factors for glaucoma progression and the effect of treatment: the early manifest glaucoma trial. Arch Ophthalmol. 2003;121(1):48\u201356.","journal-title":"Arch Ophthalmol"},{"key":"2867_CR2","doi-asserted-by":"crossref","unstructured":"Brusini P, Salvetat ML, Zeppieri M. How to Measure Intraocular Pressure: An Updated Review of Various Tonometers. J Clin Med. 2021;10(17):3860. https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC8456330\/.","DOI":"10.3390\/jcm10173860"},{"issue":"1","key":"2867_CR3","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","volume":"31","author":"DA Luce","year":"2005","unstructured":"Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refr Surg. 2005;31(1):156\u201362.","journal-title":"J Cataract Refr Surg"},{"issue":"1","key":"2867_CR4","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1167\/iovs.12-10984","volume":"54","author":"J Hong","year":"2013","unstructured":"Hong J, Xu J, Wei A, Deng SX, Cui X, Yu X, et al. A new tonometer\u2013the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest Ophthalmol Vis Sci. 2013;54(1):659\u201365.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"10","key":"2867_CR5","doi-asserted-by":"publisher","first-page":"4410","DOI":"10.1167\/iovs.06-0158","volume":"47","author":"JM Martinez-de-la-Casa","year":"2006","unstructured":"Martinez-de-la-Casa JM, Garcia-Feijoo J, Fernandez-Vidal A, Mendez-Hernandez C, Garcia-Sanchez J. Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements. Invest Ophth Vis Sci. 2006;47(10):4410\u20134.","journal-title":"Invest Ophth Vis Sci"},{"issue":"1","key":"2867_CR6","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jcrs.2004.09.031","volume":"31","author":"J Liu","year":"2005","unstructured":"Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31(1):146\u201355.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"2867_CR7","doi-asserted-by":"publisher","first-page":"4410","DOI":"10.1167\/iovs.06-0158","volume":"47","author":"JM Martinez-de-la-Casa","year":"2006","unstructured":"Martinez-de-la-Casa JM, Garcia-Feijoo J, Fernandez-Vidal A, Mendez-Hernandez C, Garcia-Sanchez J. Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements. Invest Ophthalmol Vis Sci. 2006;47(10):4410\u20134.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"2867_CR8","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1111\/j.1755-3768.1975.tb01135.x","volume":"53","author":"N Ehlers","year":"1975","unstructured":"Ehlers N, Bramsen T, Sperling S. Applanation tonometry and central corneal thickness. Acta Ophthalmol. 1975;53(1):34\u201343.","journal-title":"Acta Ophthalmol"},{"issue":"6","key":"2867_CR9","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1097\/IJG.0000000000000359","volume":"25","author":"FJ Bao","year":"2016","unstructured":"Bao FJ, Huang ZX, Huang JH, Wang JJ, Deng ML, Li LN, et al. Clinical evaluation of methods to correct intraocular pressure measurements by the goldmann applanation tonometer, ocular response analyzer, and corvis st tonometer for the effects of corneal stiffness parameters. J Glaucoma. 2016;25(6):510\u20139.","journal-title":"J Glaucoma"},{"issue":"8","key":"2867_CR10","doi-asserted-by":"publisher","first-page":"550","DOI":"10.3928\/1081597X-20160524-01","volume":"32","author":"R Vinciguerra","year":"2016","unstructured":"Vinciguerra R, Elsheikh A, Roberts CJ, Ambrosio R, Kang DSY, Lopes BT, et al. Influence of pachymetry and intraocular pressure on dynamic corneal response parameters in healthy patients. J Refract Surg. 2016;32(8):550\u201361.","journal-title":"J Refract Surg"},{"key":"2867_CR11","doi-asserted-by":"publisher","unstructured":"Lee M, Ahn J. Effects of Central Corneal Stromal Thickness and Epithelial Thickness on Intraocular Pressure Using Goldmann Applanation and Non-Contact Tonometers. Plos One. 2016;11(3):e0151868. https:\/\/doi.org\/10.1371\/journal.pone.0151868","DOI":"10.1371\/journal.pone.0151868"},{"key":"2867_CR12","doi-asserted-by":"publisher","unstructured":"Rogowska ME, Iskander DR. Age-Related Changes in Corneal Deformation Dynamics Utilizing Scheimpflug Imaging. Plos One. 2015;10(10):e0140093. https:\/\/doi.org\/10.1371\/journal.pone.0140093.","DOI":"10.1371\/journal.pone.0140093"},{"issue":"6","key":"2867_CR13","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/S0161-6420(98)96021-3","volume":"105","author":"PJ Foster","year":"1998","unstructured":"Foster PJ, Baasanhu J, Alsbirk PH, Munkhbayar D, Uranchimeg D, Johnson GJ. Central corneal thickness and intraocular pressure in a Mongolian population. Ophthalmology. 1998;105(6):969\u201373.","journal-title":"Ophthalmology"},{"key":"2867_CR14","doi-asserted-by":"publisher","first-page":"3305","DOI":"10.2147\/OPTH.S278167","volume":"14","author":"SC Chow","year":"2020","unstructured":"Chow SC, Yeung BYM. A review on different tonometers for intraocular pressure measurement after photorefractive keratectomy or small incision lenticule extraction. Clin Ophthalmol. 2020;14:3305\u201323.","journal-title":"Clin Ophthalmol"},{"issue":"6","key":"2867_CR15","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1016\/j.ophtha.2004.12.033","volume":"112","author":"DH Chang","year":"2005","unstructured":"Chang DH, Stulting RD. Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology. 2005;112(6):1009\u201316.","journal-title":"Ophthalmology"},{"issue":"12","key":"2867_CR16","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.jcrs.2017.08.019","volume":"43","author":"H Lee","year":"2017","unstructured":"Lee H, Roberts CJ, Kim TI, Ambrosio R, Elsheikh A, Kang DSY. Changes in biomechanically corrected intraocular pressure and dynamic corneal response parameters before and after transepithelial photorefractive keratectomy and femtosecond laser-assisted laser in situ keratomileusis. J Cataract Refr Surg. 2017;43(12):1495\u2013503.","journal-title":"J Cataract Refr Surg"},{"issue":"1","key":"2867_CR17","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0170206","volume":"12","author":"Y Nakao","year":"2017","unstructured":"Nakao Y, Kiuchi Y, Okimoto S. a comparison of the corrected intraocular pressure obtained by the corvis ST and reichert 7CR tonometers in glaucoma patients. PLoS ONE. 2017;12(1): e0170206.","journal-title":"PLoS ONE"},{"issue":"9","key":"2867_CR18","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0238395","volume":"15","author":"Y Nakao","year":"2020","unstructured":"Nakao Y, Kiuchi Y, Okumichi H. Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma. PLoS One. 2020;15(9): e0238395.","journal-title":"PLoS One"},{"issue":"4","key":"2867_CR19","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1136\/bjophthalmol-2019-314370","volume":"104","author":"M Matsuura","year":"2020","unstructured":"Matsuura M, Murata H, Fujino Y, Yanagisawa M, Nakao Y, Tokumo K, et al. Relationship between novel intraocular pressure measurement from Corvis ST and central corneal thickness and corneal hysteresis. Brit J Ophthalmol. 2020;104(4):563\u20138.","journal-title":"Brit J Ophthalmol"},{"issue":"9","key":"2867_CR20","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1080\/10255842.2015.1077515","volume":"19","author":"AA Joda","year":"2016","unstructured":"Joda AA, Shervin MMS, Kook D, Elsheikh A. Development and validation of a correction equation for Corvis tonometry. Comput Method Biomec. 2016;19(9):943\u201353.","journal-title":"Comput Method Biomec"},{"issue":"9","key":"2867_CR21","doi-asserted-by":"publisher","first-page":"1316","DOI":"10.1016\/j.jcrs.2019.04.004","volume":"45","author":"KJ Chen","year":"2019","unstructured":"Chen KJ, Eliasy A, Vinciguerra R, Abass A, Lopes BT, Vinciguerra P, et al. Development and validation of a new intraocular pressure estimate for patients with soft corneas. J Cataract Refr Surg. 2019;45(9):1316\u201323.","journal-title":"J Cataract Refr Surg"},{"issue":"2","key":"2867_CR22","doi-asserted-by":"publisher","first-page":"43","DOI":"10.3921\/joptom.2008.43","volume":"1","author":"CGV De Moraes","year":"2008","unstructured":"De Moraes CGV, Prata TS, Liebmann J, Ritch R. Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. Journal of optometry. 2008;1(2):43\u20139.","journal-title":"Journal of optometry"},{"issue":"10","key":"2867_CR23","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0140093","volume":"10","author":"ME Rogowska","year":"2015","unstructured":"Rogowska ME, Iskander DR. Age-related changes in corneal deformation dynamics utilizing scheimpflug imaging. PLoS One. 2015;10(10): e0140093.","journal-title":"PLoS One"},{"key":"2867_CR24","doi-asserted-by":"crossref","unstructured":"Koprowski R, Wilczy\u0144ski S. Corneal vibrations during intraocular pressure measurement with an air-puff method. J Healthc Eng. 2018;2018:Article ID 5705749. https:\/\/www.hindawi.com\/journals\/jhe\/2018\/5705749\/.","DOI":"10.1155\/2018\/5705749"},{"issue":"8","key":"2867_CR25","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0104904","volume":"9","author":"S Kling","year":"2014","unstructured":"Kling S, Bekesi N, Dorronsoro C, Pascual D, Marcos S. Corneal viscoelastic properties from finite-element analysis of in vivo air-puff deformation. PLoS ONE. 2014;9(8):e104904.","journal-title":"PLoS ONE"},{"key":"2867_CR26","doi-asserted-by":"crossref","unstructured":"Shih PJ, Huang CJ, Huang TH, Lin HC, Yen JY, Wang IJ, et al. Estimation of the corneal young\u2019s modulus in vivo based on a fluid-filled spherical-shell model with scheimpflug imaging. J Ophthalmol. 2017;2017:5410143.","DOI":"10.1155\/2017\/5410143"},{"issue":"1","key":"2867_CR27","doi-asserted-by":"publisher","first-page":"13906","DOI":"10.1038\/s41598-017-14293-0","volume":"7","author":"PJ Shih","year":"2017","unstructured":"Shih PJ, Wang IJ, Cai WF, Yen JY. Biomechanical simulation of stress concentration and intraocular pressure in corneas subjected to myopic refractive surgical procedures. Sci Rep. 2017;7(1):13906.","journal-title":"Sci Rep"},{"key":"2867_CR28","unstructured":"Roberts CJ, Liu J. Corneal Biomechanics: from theory to practice: Kugler Publications; 2017. pp. 91-114."},{"issue":"9","key":"2867_CR29","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1097\/OPX.0b013e3181559db2","volume":"84","author":"A Lam","year":"2007","unstructured":"Lam A, Chen D, Chiu R, Chui WS. Comparison of IOP measurements between ORA and GAT in normal Chinese. Optometry Vision Sci. 2007;84(9):909\u201314.","journal-title":"Optometry Vision Sci"},{"key":"2867_CR30","doi-asserted-by":"crossref","unstructured":"Koprowski R, Wilczynski S. Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method. J Healthc Eng. 2018;2018:5705749. https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC5828335\/.","DOI":"10.1155\/2018\/5705749"},{"issue":"1","key":"2867_CR31","doi-asserted-by":"publisher","first-page":"e14","DOI":"10.1111\/aos.12408","volume":"93","author":"L Agnifili","year":"2015","unstructured":"Agnifili L, Mastropasqua R, Frezzotti P, Fasanella V, Motolese I, Pedrotti E, et al. Circadian intraocular pressure patterns in healthy subjects, primary open angle and normal tension glaucoma patients with a contact lens sensor. Acta Ophthalmol. 2015;93(1):e14-21.","journal-title":"Acta Ophthalmol"},{"issue":"3","key":"2867_CR32","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1167\/tvst.8.3.48","volume":"8","author":"M Matsuura","year":"2019","unstructured":"Matsuura M, Murata H, Fujino Y, Yanagisawa M, Nakao Y, Nakakura S, et al. Repeatability of the novel intraocular pressure measurement from corvis ST. Transl Vis Sci Technol. 2019;8(3):48.","journal-title":"Transl Vis Sci Technol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-023-02867-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-023-02867-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-023-02867-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,27]],"date-time":"2023-03-27T08:05:55Z","timestamp":1679904355000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-023-02867-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,27]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["2867"],"URL":"https:\/\/doi.org\/10.1186\/s12886-023-02867-8","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,27]]},"assertion":[{"value":"15 July 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This retrospective study was reviewed and approved by the Research Ethics Committee of National Taiwan University Hospital, Taiwan (No. 1053730732) and was conducted in accordance with all ethical standards outlined in the Declaration of Helsinki. The IRB of National Taiwan University Hospital approved waiver of informed consent on the basis that the study involves no more than minimal risk to the subjects. All data has undergone de-identification prior to our research.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"124"}}