{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T16:22:27Z","timestamp":1782231747705,"version":"3.54.5"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T00:00:00Z","timestamp":1713744000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T00:00:00Z","timestamp":1713744000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Joint Program of Henan Provincial Medical Science & Technology Plan","award":["LHGJ20220086"],"award-info":[{"award-number":["LHGJ20220086"]}]},{"name":"Henan Provincial science and technology research and development plan joint fund project","award":["232103810052"],"award-info":[{"award-number":["232103810052"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)\/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-024-03448-z","type":"journal-article","created":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T12:02:14Z","timestamp":1713787334000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Repeatability assessment of anterior segment measurements in myopic patients using an anterior segment OCT with placido corneal topography and agreement with a swept-source OCT"],"prefix":"10.1186","volume":"24","author":[{"given":"Hao","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Shuang","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen-Jiu","family":"Pang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,22]]},"reference":[{"key":"3448_CR1","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.exer.2018.12.008","volume":"180","author":"M El Hamdaoui","year":"2019","unstructured":"El Hamdaoui M, Gann DW, Norton TT, Grytz R. Matching the LenStar optical biometer to A-Scan ultrasonography for use in small animal eyes with application to tree shrews. Exp Eye Res. 2019;180:250\u20139. https:\/\/doi.org\/10.1016\/j.exer.2018.12.008","journal-title":"Exp Eye Res"},{"issue":"1","key":"3448_CR2","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1186\/s12886-020-01754-w","volume":"20","author":"J Xu","year":"2020","unstructured":"Xu J, Li C, Wang L, Li C, Li X, Lu P. Influence of measurement differences of anterior chamber depth and axial length on lens thickness evaluation in cataract patients: a comparison of two tests. BMC Ophthalmol. 2020;20(1):481. https:\/\/doi.org\/10.1186\/s12886-020-01754-w","journal-title":"BMC Ophthalmol"},{"issue":"6","key":"3448_CR3","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.3980\/j.issn.2222-3959.2015.06.13","volume":"8","author":"N Hamzeh","year":"2015","unstructured":"Hamzeh N, Moghimi S, Latifi G, Mohammadi M, Khatibi N, Lin SC. Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography. Int J Ophthalmol. 2015;8(6):1151\u20135. https:\/\/doi.org\/10.3980\/j.issn.2222-3959.2015.06.13","journal-title":"Int J Ophthalmol"},{"issue":"4","key":"3448_CR4","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1016\/j.ajo.2015.07.007","volume":"160","author":"V Yeter","year":"2015","unstructured":"Yeter V, Arit\u00fcrk N, B\u0130r\u0130nc\u0130 H, S\u00fcll\u00fc Y, G\u00fcng\u00f6r \u0130. Effects of Birth Weight on Anterior segment measurements in full-term children without low Birth Weight by Dual-Scheimpflug Analyzer. Am J Ophthalmol. 2015;160(4):832\u201340. https:\/\/doi.org\/10.1016\/j.ajo.2015.07.007","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"3448_CR5","doi-asserted-by":"publisher","first-page":"352","DOI":"10.3928\/1081597X-20170216-01","volume":"33","author":"JS Titiyal","year":"2017","unstructured":"Titiyal JS, Rathi A, Kaur M, Falera R. AS-OCT as a rescue Tool during difficult lenticule extraction in SMILE. J Refract Surg. 2017;33(5):352\u20134. https:\/\/doi.org\/10.3928\/1081597X-20170216-01","journal-title":"J Refract Surg"},{"issue":"1","key":"3448_CR6","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1186\/s12886-017-0425-3","volume":"17","author":"H Akil","year":"2017","unstructured":"Akil H, Dastiridou A, Marion K, Francis BA, Chopra V. Effects of diurnal, lighting, and angle-of-incidence variation on anterior segment optical coherence tomography (AS-OCT) angle metrics. BMC Ophthalmol. 2017;17(1):31. https:\/\/doi.org\/10.1186\/s12886-017-0425-3","journal-title":"BMC Ophthalmol"},{"key":"3448_CR7","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015","volume":"187","author":"T Nakamura","year":"2018","unstructured":"Nakamura T, Isogai N, Kojima T, Yoshida Y, Sugiyama Y. Implantable Collamer Lens sizing Method based on swept-source Anterior Segment Optical Coherence Tomography. Am J Ophthalmol. 2018;187:99\u2013107. https:\/\/doi.org\/10.1016\/j.ajo.2017.12.015","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"3448_CR8","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1186\/s12886-021-02213-w","volume":"21","author":"Y Wu","year":"2021","unstructured":"Wu Y, Zhang S, Zhong Y, Bian A, Zhang Y, Wang Z. Prediction of effective Lens position using anterior segment optical coherence tomography in Chinese subjects with angle closure. BMC Ophthalmol. 2021;21(1):454. https:\/\/doi.org\/10.1186\/s12886-021-02213-w","journal-title":"BMC Ophthalmol"},{"issue":"7","key":"3448_CR9","doi-asserted-by":"publisher","first-page":"2309","DOI":"10.1007\/s00417-022-05571-3","volume":"260","author":"A Lazaridis","year":"2022","unstructured":"Lazaridis A, Spiru B, Giallouros E, Sekundo W, Schroeder FM, Messerschmidt-Roth A, Droutsas K. Five-year follow-up of corneal morphology and corneal refractive power changes after uneventful DMEK. Graefes Arch Clin Exp Ophthalmol. 2022;260(7):2309\u201319. https:\/\/doi.org\/10.1007\/s00417-022-05571-3","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"1","key":"3448_CR10","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1186\/s12886-019-1236-5","volume":"19","author":"M Chen","year":"2019","unstructured":"Chen M, Zhang L, Xu J, Chen X, Gu Y, Ren Y, Wang K. Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group. BMC Ophthalmol. 2019;19(1):225. https:\/\/doi.org\/10.1186\/s12886-019-1236-5","journal-title":"BMC Ophthalmol"},{"issue":"12","key":"3448_CR11","doi-asserted-by":"publisher","first-page":"1554","DOI":"10.1136\/bjophthalmol-2013-303477","volume":"97","author":"S Fukuda","year":"2013","unstructured":"Fukuda S, Beheregaray S, Hoshi S, Yamanari M, Lim Y, Hiraoka T, Yasuno Y, Oshika T. Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis. Br J Ophthalmol. 2013;97(12):1554\u20139. https:\/\/doi.org\/10.1136\/bjophthalmol-2013-303477","journal-title":"Br J Ophthalmol"},{"issue":"12","key":"3448_CR12","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","volume":"119","author":"Y Li","year":"2012","unstructured":"Li Y, Tan O, Brass R, Weiss JL, Huang D. Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology. 2012;119(12):2425\u201333. https:\/\/doi.org\/10.1016\/j.ophtha.2012.06.023","journal-title":"Ophthalmology"},{"issue":"1","key":"3448_CR13","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1167\/iovs.12-10105","volume":"54","author":"K Ishii","year":"2013","unstructured":"Ishii K, Yamanari M, Iwata H, Yasuno Y, Oshika T. Relationship between changes in crystalline lens shape and axial elongation in young children. Invest Ophthalmol Vis Sci. 2013;54(1):771\u20137. https:\/\/doi.org\/10.1167\/iovs.12-10105","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"3448_CR14","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/s00417-017-3832-5","volume":"256","author":"N Mart\u00ednez-Albert","year":"2018","unstructured":"Mart\u00ednez-Albert N, Esteve-Taboada JJ, Mont\u00e9s-Mic\u00f3 R. Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT. Graefes Arch Clin Exp Ophthalmol. 2018;256(1):113\u201323. https:\/\/doi.org\/10.1007\/s00417-017-3832-5","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"6","key":"3448_CR15","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.1016\/j.ophtha.2015.01.021","volume":"122","author":"Y Ueno","year":"2015","unstructured":"Ueno Y, Hiraoka T, Miyazaki M, Ito M, Oshika T. Corneal thickness profile and posterior corneal astigmatism in normal corneas. Ophthalmology. 2015;122(6):1072\u20138. https:\/\/doi.org\/10.1016\/j.ophtha.2015.01.021","journal-title":"Ophthalmology"},{"issue":"1","key":"3448_CR16","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1038\/s41598-020-57926-7","volume":"10","author":"D Schiano-Lomoriello","year":"2020","unstructured":"Schiano-Lomoriello D, Bono V, Abicca I, Savini G. Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus. Sci Rep. 2020;10(1):1124. https:\/\/doi.org\/10.1038\/s41598-020-57926-7","journal-title":"Sci Rep"},{"issue":"4","key":"3448_CR17","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.jcrs.2018.02.015","volume":"44","author":"G Savini","year":"2018","unstructured":"Savini G, Schiano-Lomoriello D, Hoffer KJ. Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras. J Cataract Refract Surg. 2018;44(4):471\u20138. https:\/\/doi.org\/10.1016\/j.jcrs.2018.02.015","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"3448_CR18","doi-asserted-by":"publisher","first-page":"616","DOI":"10.3928\/1081597X-20210610-02","volume":"37","author":"Q Wang","year":"2021","unstructured":"Wang Q, Chen M, Ning R, Savini G, Wang Y, Zhang T, Lin X, Chen X, Huang J. The Precision of a New Anterior Segment Optical Coherence Tomographer and its comparison with a swept-source OCT-Based optical biometer in patients with cataract. J Refract Surg. 2021;37(9):616\u201322. https:\/\/doi.org\/10.3928\/1081597X-20210610-02","journal-title":"J Refract Surg"},{"issue":"4","key":"3448_CR19","doi-asserted-by":"publisher","first-page":"330","DOI":"10.1111\/j.1475-1313.2011.00851.x","volume":"31","author":"C McAlinden","year":"2011","unstructured":"McAlinden C, Khadka J, Pesudovs K. Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology. Ophthalmic Physiol Opt. 2011;31(4):330\u20138. https:\/\/doi.org\/10.1111\/j.1475-1313.2011.00851.x","journal-title":"Ophthalmic Physiol Opt"},{"issue":"1","key":"3448_CR20","doi-asserted-by":"publisher","first-page":"12345","DOI":"10.1038\/s41598-018-30173-7","volume":"8","author":"M Brunner","year":"2018","unstructured":"Brunner M, Czanner G, Vinciguerra R, Romano V, Ahmad S, Batterbury M, Britten C, Willoughby CE, Kaye SB. Improving precision for detecting change in the shape of the cornea in patients with keratoconus. Sci Rep. 2018;8(1):12345. https:\/\/doi.org\/10.1038\/s41598-018-30173-7","journal-title":"Sci Rep"},{"issue":"1","key":"3448_CR21","doi-asserted-by":"publisher","first-page":"16537","DOI":"10.1038\/s41598-019-52987-9","volume":"9","author":"G Savini","year":"2019","unstructured":"Savini G, Calossi A, Schiano-Lomoriello D, Barboni P. Precision and normative values of a new computerized chart for contrast Sensitivity Testing. Sci Rep. 2019;9(1):16537. https:\/\/doi.org\/10.1038\/s41598-019-52987-9","journal-title":"Sci Rep"},{"issue":"2","key":"3448_CR22","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1177\/096228029900800204","volume":"8","author":"JM Bland","year":"1999","unstructured":"Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8(2):135\u201360. https:\/\/doi.org\/10.1177\/096228029900800204","journal-title":"Stat Methods Med Res"},{"issue":"1","key":"3448_CR23","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1038\/s41598-020-79674-4","volume":"11","author":"D Schiano-Lomoriello","year":"2021","unstructured":"Schiano-Lomoriello D, Hoffer KJ, Abicca I, Savini G. Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices. Sci Rep. 2021;11(1):983. https:\/\/doi.org\/10.1038\/s41598-020-79674-4","journal-title":"Sci Rep"},{"issue":"30","key":"3448_CR24","doi-asserted-by":"publisher","first-page":"e1219","DOI":"10.1097\/MD.0000000000001219","volume":"94","author":"TCY Chan","year":"2015","unstructured":"Chan TCY, Biswas S, Yu M, Jhanji V. Longitudinal evaluation of Cornea with swept-source Optical Coherence Tomography and Scheimpflug Imaging before and after Lasik. Med (Baltim). 2015;94(30):e1219. https:\/\/doi.org\/10.1097\/MD.0000000000001219","journal-title":"Med (Baltim)"},{"issue":"10","key":"3448_CR25","doi-asserted-by":"publisher","first-page":"1196","DOI":"10.1097\/OPX.0000000000001785","volume":"98","author":"S Biswas","year":"2021","unstructured":"Biswas S, Biswas P. Agreement and repeatability of corneal thickness and Radius among three different corneal measurement devices. Optom Vis Sci. 2021;98(10):1196\u2013202. https:\/\/doi.org\/10.1097\/OPX.0000000000001785","journal-title":"Optom Vis Sci"},{"issue":"7","key":"3448_CR26","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1080\/08164622.2022.2152312","volume":"106","author":"E Garcia Ardoy","year":"2023","unstructured":"Garcia Ardoy E, Mateos N, Roda L, Torrado Sierra O, Baptista AM, Serra PM. Repeatability and agreement of swept-source optical coherence tomography and partial coherence interferometry biometers in myopes. Clin Exp Optom. 2023;106(7):783\u201392. https:\/\/doi.org\/10.1080\/08164622.2022.2152312","journal-title":"Clin Exp Optom"},{"issue":"10","key":"3448_CR27","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1097\/j.jcrs.0000000000000633","volume":"47","author":"AD Fi\u015fu\u015f","year":"2021","unstructured":"Fi\u015fu\u015f AD, Hirnschall ND, Ruiss M, Pilwachs C, Georgiev S, Findl O. Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer. J Cataract Refract Surg. 2021;47(10):1302\u20137. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000633","journal-title":"J Cataract Refract Surg"},{"key":"3448_CR28","doi-asserted-by":"publisher","first-page":"9739878","DOI":"10.1155\/2020\/9739878","volume":"2020","author":"S Chen","year":"2020","unstructured":"Chen S, Gao R, McAlinden C, Ye J, Wang Y, Chen M, Huang J, Sun Y, Yu AY. Comparison of anterior ocular biometric measurements using swept-source and time-domain Optical Coherence Tomography. J Ophthalmol. 2020;2020:9739878. https:\/\/doi.org\/10.1155\/2020\/9739878","journal-title":"J Ophthalmol"},{"key":"3448_CR29","doi-asserted-by":"crossref","unstructured":"Dembski M, Nowi\u0144ska A, Ulfik-Dembska K, Wyl\u0119ga\u0142a E. Swept Source Optical Coherence Tomography Analysis of the Selected Eye\u2019s Anterior Segment Parameters. J Clin Med., Savini G, Barboni P, Carbonelli M, Hoffer KJ. Repeatability of automatic measurements by a new Scheimpflug camera combined with Placido topography. J Cataract Refract Surg. 2011;37(10):1809-16. DOI: 10.1016\/j.jcrs.2011.04.033.","DOI":"10.1016\/j.jcrs.2011.04.033"},{"issue":"11","key":"3448_CR30","doi-asserted-by":"publisher","first-page":"1934","DOI":"10.1016\/j.jcrs.2012.06.049","volume":"38","author":"J Aramberri","year":"2012","unstructured":"Aramberri J, Araiz L, Garcia A, Illarramendi I, Olmos J, Oyanarte I, et al. Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement. J Cataract Refract Surg. 2012;38(11):1934\u201349. https:\/\/doi.org\/10.1016\/j.jcrs.2012.06.049","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"3448_CR31","doi-asserted-by":"publisher","first-page":"1951","DOI":"10.1016\/j.ophtha.2013.02.022","volume":"120","author":"J Huang","year":"2013","unstructured":"Huang J, Ding X, Savini G, Pan C, Feng Y, Cheng D, Hua Y, Hu X, Wang Q. A comparison between Scheimpflug imaging and optical coherence tomography in measuring corneal thickness. Ophthalmology. 2013;120(10):1951\u20138. https:\/\/doi.org\/10.1016\/j.ophtha.2013.02.022","journal-title":"Ophthalmology"},{"issue":"7","key":"3448_CR32","doi-asserted-by":"publisher","first-page":"1484","DOI":"10.1016\/j.ophtha.2011.03.009","volume":"118","author":"KJ Hoffer","year":"2011","unstructured":"Hoffer KJ. Definition of ACD. Ophthalmology. 2011;118(7):1484. https:\/\/doi.org\/10.1016\/j.ophtha.2011.03.009","journal-title":"Ophthalmology"},{"issue":"1","key":"3448_CR33","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1186\/s12886-023-03148-0","volume":"23","author":"Y Wu","year":"2023","unstructured":"Wu Y, Shen T, Tan L, He T, Zheng Q, Hong C. Corneal remodeling after SMILE for moderate and high myopia: short-term assessment of spatial changes in corneal volume and thickness. BMC Ophthalmol. 2023;23(1):402. https:\/\/doi.org\/10.1186\/s12886-023-03148-0","journal-title":"BMC Ophthalmol"},{"issue":"3","key":"3448_CR34","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1007\/s40123-023-00693-1","volume":"12","author":"R Ning","year":"2023","unstructured":"Ning R, Huang X, Jin Y, Lei CS, Ma X, Xu S, Xiahou J, Savini G, Schiano-Lomoriello D, Wang X, Zhou X, Huang J. Corneal higher-order aberrations measurements: Precision of SD-OCT\/Placido Topography and Comparison with a Scheimpflug\/Placido Topography in eyes after small-incision Lenticule extraction. Ophthalmol Ther. 2023;12(3):1595\u2013610. https:\/\/doi.org\/10.1007\/s40123-023-00693-1","journal-title":"Ophthalmol Ther"},{"issue":"1","key":"3448_CR35","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s40662-023-00348-z","volume":"10","author":"S Georgiev","year":"2023","unstructured":"Georgiev S, Ruiss M, Dana-Fisus A, Leitgeb RA, Findl O. Comparison of corneal aberrations from anterior segment swept source OCT versus Placido-topography combined spectral domain OCT in cataract patients. Eye Vis (Lond). 2023;10(1):30. https:\/\/doi.org\/10.1186\/s40662-023-00348-z","journal-title":"Eye Vis (Lond)"},{"issue":"1","key":"3448_CR36","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1186\/s40662-023-00330-9","volume":"10","author":"Y Wang","year":"2023","unstructured":"Wang Y, Wan T, Liu L, Xue Y, Chen X, Savini G, Schiano-Lomoriello D, Zhou X, Yu J, Huang J. Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer. Eye Vis (Lond). 2023;10(1):13. https:\/\/doi.org\/10.1186\/s40662-023-00330-9","journal-title":"Eye Vis (Lond)"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03448-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-024-03448-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03448-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,22]],"date-time":"2024-04-22T12:04:37Z","timestamp":1713787477000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-024-03448-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,22]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3448"],"URL":"https:\/\/doi.org\/10.1186\/s12886-024-03448-z","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,22]]},"assertion":[{"value":"22 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study followed the tenets of the Declaration of Helsinki and was approved by the institutional review board of Henan Provincial Eye Hospital. Written informed consent was obtained from all patients enrolled.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"182"}}