{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T21:19:01Z","timestamp":1776201541071,"version":"3.50.1"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T00:00:00Z","timestamp":1713225600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T00:00:00Z","timestamp":1713225600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["22K18231"],"award-info":[{"award-number":["22K18231"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008884","name":"Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100008884","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Japan Medical Herb Association Research Grant Program"},{"name":"Clinical Research Promotion Foundation"},{"DOI":"10.13039\/501100008670","name":"Terumo Foundation for Life Sciences and Arts","doi-asserted-by":"publisher","award":["22-III 1009"],"award-info":[{"award-number":["22-III 1009"]}],"id":[{"id":"10.13039\/501100008670","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100009619","name":"Japan Agency for Medical Research and Development","doi-asserted-by":"publisher","award":["23he0422031j0001"],"award-info":[{"award-number":["23he0422031j0001"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>This study aimed to compare the results of the Chronos binocular\/monocular refraction system, that measures objective and subjective ocular refraction in one unit, to objective findings obtained from a conventional autorefractometer and a conventional subjective ocular refraction using a trial-frame in real space.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Twenty-eight healthy volunteers (21.2\u2009\u00b1\u20091.5 years old) were included in this study. Objective ocular refraction was measured using two tests: the Chronos binocular\/monocular refraction system under binocular conditions and a conventional autorefractometer under monocular conditions. Subjective ocular refraction was measured using three tests: Chronos binocular\/monocular refraction system under binocular, monocular conditions, and trial-frame in the real space under monocular conditions. The measurement distance was set to 5.0\u00a0m for each test. All ocular refractions were converted into spherical equivalents (SEs).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The objective SE was significantly more negative with Chronos binocular\/monocular refraction system under binocular condition (\u2212\u20094.08\u2009\u00b1\u20092.76 D) than with the conventional autorefractometer under monocular condition (\u2212\u20093.85\u2009\u00b1\u20092.66 D) (<jats:italic>P<\/jats:italic>\u2009=\u20090.002). Although, the subjective SE was significantly more negative with Chronos binocular\/monocular refraction system under binocular condition (\u2212\u20093.55\u2009\u00b1\u20092.67 D) than with the trial-frame in the real space under monocular condition (\u2212\u20093.33\u2009\u00b1\u20092.75 D) (<jats:italic>P<\/jats:italic>\u2009=\u20090.002), Chronos binocular\/monocular refraction system under monocular condition (\u2212\u20093.17\u2009\u00b1\u20092.57 D) was not significantly different from that in trial-frame in real space under monocular condition (<jats:italic>P<\/jats:italic>\u2009=\u20090.33).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>These findings suggest that the Chronos binocular\/monocular refraction system, which can complete both objective and subjective ocular refraction tests in a single unit, is suitable for screening ocular refraction, although it produces slightly more myopic results. Furthermore, subjective ocular refraction testing accuracy in Chronos binocular\/monocular refraction system can be equivalent to trial-frame in real-space testing by switching from binocular to monocular condition.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-024-03449-y","type":"journal-article","created":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T08:02:09Z","timestamp":1713254529000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of objective and subjective binocular ocular refraction with looking in type"],"prefix":"10.1186","volume":"24","author":[{"given":"Megumi","family":"Fukushima","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1420-9844","authenticated-orcid":false,"given":"Masakazu","family":"Hirota","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takafumi","family":"Yukimori","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akio","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoko","family":"Hirohara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Saika","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kumiko","family":"Matsuoka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,4,16]]},"reference":[{"key":"3449_CR1","unstructured":"Gurnani B, Kaur K. Autorefractors. StatPearls. edn. Treasure Island (FL); 2023."},{"issue":"3","key":"3449_CR2","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1111\/opo.12363","volume":"37","author":"GD Hastings","year":"2017","unstructured":"Hastings GD, Marsack JD, Nguyen LC, Cheng H, Applegate RA. Is an objective refraction optimised using the visual Strehl ratio better than a subjective refraction? Ophthalmic Physiol Opt. 2017;37(3):317\u201325.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"3","key":"3449_CR3","doi-asserted-by":"publisher","first-page":"1558","DOI":"10.3390\/ijerph19031558","volume":"19","author":"M Rossato","year":"2022","unstructured":"Rossato M, Nart A, Messina G, Favro F, Rossato V, Rrutja E, Biancalana V. The Refraction Assessment and the electronic trial Frame Measurement during Standing or sitting position can affect Postural Stability. Int J Environ Res Public Health. 2022;19(3):1558.","journal-title":"Int J Environ Res Public Health"},{"issue":"5","key":"3449_CR4","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1007\/s00417-022-05936-8","volume":"261","author":"Y Lei","year":"2023","unstructured":"Lei Y, Chen X, Cheng M, Li B, Jiang Y, Xu Y, Wang X. Comparisons of objective and subjective refraction with and without cycloplegia using binocular wavefront optometer with autorefraction and retinoscopy in school-age children. Graefe\u2019s Archive Clin Experimental Ophthalmol. 2023;261(5):1465\u201372.","journal-title":"Graefe\u2019s Archive Clin Experimental Ophthalmol"},{"issue":"10","key":"3449_CR5","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/0042-6989(80)90063-2","volume":"20","author":"DG Green","year":"1980","unstructured":"Green DG, Powers MK, Banks MS. Depth of focus, eye size and visual acuity. Vis Res. 1980;20(10):827\u201335.","journal-title":"Vis Res"},{"issue":"12","key":"3449_CR6","doi-asserted-by":"publisher","first-page":"6858","DOI":"10.1167\/iovs.10-5499","volume":"51","author":"KY Li","year":"2010","unstructured":"Li KY, Tiruveedhula P, Roorda A. Intersubject variability of foveal cone photoreceptor density in relation to eye length. Invest Ophthalmol Vis Sci. 2010;51(12):6858\u201367.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"2","key":"3449_CR7","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1038\/nn.2465","volume":"13","author":"EA Rossi","year":"2010","unstructured":"Rossi EA, Roorda A. The relationship between visual resolution and cone spacing in the human fovea. Nat Neurosci. 2010;13(2):156\u20137.","journal-title":"Nat Neurosci"},{"issue":"5","key":"3449_CR8","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1111\/j.1475-1313.2011.00834.x","volume":"31","author":"M Rosenfield","year":"2011","unstructured":"Rosenfield M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic Physiol Opt. 2011;31(5):502\u201315.","journal-title":"Ophthalmic Physiol Opt"},{"key":"3449_CR9","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.2147\/OPTH.S259011","volume":"15","author":"JA Katz","year":"2021","unstructured":"Katz JA, Karpecki PM, Dorca A, Chiva-Razavi S, Floyd H, Barnes E, Wuttke M, Donnenfeld E. Presbyopia\u2013 A Review of Current Treatment options and emerging therapies. Clin Ophthalmol. 2021;15:2167\u201378.","journal-title":"Clin Ophthalmol"},{"issue":"1","key":"3449_CR10","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.optom.2020.04.003","volume":"14","author":"N Yazdani","year":"2021","unstructured":"Yazdani N, Sadeghi R, Ehsaei A, Taghipour A, Hasanzadeh S, Zarifmahmoudi L, Heravian Shandiz J. Under-correction or full correction of myopia? A meta-analysis. J Optom. 2021;14(1):11\u20139.","journal-title":"J Optom"},{"issue":"3","key":"3449_CR11","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1364\/JOSA.73.000332","volume":"73","author":"D Kersten","year":"1983","unstructured":"Kersten D, Legge GE. Convergence accommodation. J Opt Soc Am. 1983;73(3):332\u20138.","journal-title":"J Opt Soc Am"},{"issue":"1","key":"3449_CR12","doi-asserted-by":"publisher","first-page":"263","DOI":"10.4103\/ijo.IJO_884_22","volume":"71","author":"S Marmamula","year":"2023","unstructured":"Marmamula S, Bhoopalan D, Kumbham TR, Yelagondula VK, Keeffe J. Prevalence, pattern, and compliance with spectacles use among the elderly in homes for the aged in South India: the Hyderabad Ocular Morbidity in Elderly Study (HOMES). Indian J Ophthalmol. 2023;71(1):263\u20137.","journal-title":"Indian J Ophthalmol"},{"issue":"4","key":"3449_CR13","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/S0886-3350(13)80617-7","volume":"19","author":"NA Alpins","year":"1993","unstructured":"Alpins NA. A new method of analyzing vectors for changes in astigmatism. J Cataract Refract Surg. 1993;19(4):524\u201333.","journal-title":"J Cataract Refract Surg"},{"issue":"30","key":"3449_CR14","doi-asserted-by":"publisher","first-page":"9553","DOI":"10.1364\/AO.441646","volume":"60","author":"M Tamura","year":"2021","unstructured":"Tamura M, Moriguchi Y, Yeh SY, Matsumoto A, Shibutani M, Asao T, Mino T, Nakanishi M, Kubota A, Akiba M. Sensorless astigmatism correction using a variable cross-cylinder for high lateral resolution optical coherence tomography in a human retina. Appl Opt. 2021;60(30):9553\u20139.","journal-title":"Appl Opt"},{"issue":"5 Suppl","key":"3449_CR15","first-page":"S734","volume":"20","author":"IY Yeung","year":"2004","unstructured":"Yeung IY, Mantry S, Cunliffe IA, Benson MT, Shah S. Correlation of Nidek OPD-Scan objective refraction with subjective refraction. J Refract Surg. 2004;20(5 Suppl):S734\u2013736.","journal-title":"J Refract Surg"},{"issue":"23","key":"3449_CR16","doi-asserted-by":"publisher","first-page":"3934","DOI":"10.1016\/S0042-6989(99)00102-9","volume":"39","author":"J Porrill","year":"1999","unstructured":"Porrill J, Ivins JP, Frisby JP. The variation of torsion with vergence and elevation. Vis Res. 1999;39(23):3934\u201350.","journal-title":"Vis Res"},{"issue":"4","key":"3449_CR17","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1111\/j.1475-1313.2007.00484.x","volume":"27","author":"H Radhakrishnan","year":"2007","unstructured":"Radhakrishnan H, Charman WN. Age-related changes in static accommodation and accommodative miosis. Ophthalmic Physiol Opt. 2007;27(4):342\u201352.","journal-title":"Ophthalmic Physiol Opt"},{"key":"3449_CR18","doi-asserted-by":"crossref","unstructured":"Kemchoknatee P, Sunlakaviset P, Khieokhoen N, Srisombut T, Tangon D. A Comparison of Autorefraction and Subjective Refraction in an Academic Optometry Clinic. Cureus 2023.","DOI":"10.7759\/cureus.37448"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03449-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-024-03449-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03449-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T08:02:41Z","timestamp":1713254561000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-024-03449-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,16]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3449"],"URL":"https:\/\/doi.org\/10.1186\/s12886-024-03449-y","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,16]]},"assertion":[{"value":"18 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"After explaining the nature of the study and possible complications, all participants provided informed consent. This study adhered to the tenets of the 2013 revised Declaration of Helsinki of the World Medical Association. The Institutional Review Board of Teikyo University approved the experimental protocol and consent procedures (approval no. 21\u2013067).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The author M.H., is financial support to Topcon Corp. for this study performed. T.Y., A.H., Y.H., and M.S. are employees of the Topcon Corporation. As described in the Authors\u2019 Contributions section, they only contributed to setting up the study design. To avoid bias, the experiments, data analysis, and writing of this paper were conducted independently at Teikyo University. T.Y., A.H., Y.H., and M.S. were not involved in the experiments, data analyses, or manuscript writing. All other authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"170"}}