{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T16:14:46Z","timestamp":1779293686612,"version":"3.51.4"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,19]],"date-time":"2024-04-19T00:00:00Z","timestamp":1713484800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,19]],"date-time":"2024-04-19T00:00:00Z","timestamp":1713484800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Plusoptix photoscreeners are capable of measuring refractive errors of children from 1 meter distance, without cyloplegia. We aimed to compare refractive data obtained from the newest version of Plusoptix (model 12) with cycloplegic autorefraction.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We examined 111 consecutive children aged 3-7 years first by Plusoptix A12C under manifest condition and subsequently for cycloplegic refraction by Topcon KR-1 tabletop autorefractometer. Sphere, spherical equivalent, cylinder and axis of astigmatism measured by the two methods were analyzed to determine correlation, agreement and differences.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Binocular examination of 111 children aged 4.86\u00b11.27 years revealed good agreement between refractive data obtained by Plusoptix and cycloautorefraction, according to Bland-Altman plots. Significant (<jats:italic>p<\/jats:italic> &lt; 0.001) and strong correlation was found between all refractive measurements (Pearson\u2019s r value of 0.707 for sphere, 0.756 for pherical equivalent, and 0.863 for cylinder). Plusoptix mean sphere, spherical equivalent and cylinder were 1.22, 0.56, and -1.32 D, respectively. Corresponding values for cycloautorefraction were 1.63, 1.00, and -1.26 D. The difference between axis of cylinder measured by the two methods was &lt; 10\u00b0 in 144 eyes (64.9%).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Considering the significant agreement and correlation between Plusoptix photoscreener and cycloplegic autorefraction, the need for cycloplegic drops in refractive examination of children may be obviated. The mean difference between cylinder measurements are considerably trivial (0.06 D), but sphere is approximately 0.4 D underestimated by Plusoptix compared to cycloautorefraction, on average.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-024-03459-w","type":"journal-article","created":{"date-parts":[[2024,4,19]],"date-time":"2024-04-19T07:01:53Z","timestamp":1713510113000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of photorefraction by Plusoptix A12 and cycloplegic autorefraction in children"],"prefix":"10.1186","volume":"24","author":[{"given":"Hadi","family":"Ghadimi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mojgan","family":"Nikdel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Donny W.","family":"Suh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,4,19]]},"reference":[{"issue":"12","key":"3459_CR1","doi-asserted-by":"publisher","first-page":"2298","DOI":"10.1016\/j.ophtha.2006.06.015","volume":"113","author":"ML Ganz","year":"2006","unstructured":"Ganz ML, Xuan Z, Hunter DG. Prevalence and correlates of children\u2019s diagnosed eye and vision conditions. Ophthalmology. 2006;113(12):2298\u2013306. https:\/\/doi.org\/10.1016\/j.ophtha.2006.06.015.","journal-title":"Ophthalmology"},{"issue":"8","key":"3459_CR2","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.1136\/bjophthalmol-2019-314759","volume":"104","author":"Z Fu","year":"2020","unstructured":"Fu Z, Hong H, Su Z, Lou B, Pan CW, Liu H. Global prevalence of amblyopia and disease burden projections through 2040: a systematic review and meta-analysis. Br J Ophthalmol. 2020;104(8):1164\u201370. https:\/\/doi.org\/10.1136\/bjophthalmol-2019-314759.","journal-title":"Br J Ophthalmol"},{"issue":"4","key":"3459_CR3","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1067\/mpa.2000.105274","volume":"4","author":"M Eibschitz-Tsimhoni","year":"2000","unstructured":"Eibschitz-Tsimhoni M, Friedman T, Naor J, Eibschitz N, Friedman Z. Early screening for amblyogenic risk factors lowers the prevalence and severity of amblyopia. J AAPOS. 2000;4(4):194\u20139. https:\/\/doi.org\/10.1067\/mpa.2000.105274.","journal-title":"J AAPOS"},{"issue":"3","key":"3459_CR4","doi-asserted-by":"publisher","first-page":"194","DOI":"10.3928\/01913913-20170703-18","volume":"55","author":"T Williams","year":"2018","unstructured":"Williams T, Morgan LA, High R, Suh DW. Critical assessment of an ocular photoscreener. J Pediatr Ophthalmol Strabismus. 2018;55(3):194\u20139. https:\/\/doi.org\/10.3928\/01913913-20170703-18.","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"3459_CR5","doi-asserted-by":"publisher","first-page":"775","DOI":"10.2147\/OPTH.S300871","volume":"15","author":"M Keffalos","year":"2021","unstructured":"Keffalos M, Martin S, Arnold R. Drive-by photoscreening: Plusoptix, 2WIN and Blinq amblyopia detection during the COVID-19 pandemic. Clin Ophthalmol. 2021;15:775\u201382. https:\/\/doi.org\/10.2147\/OPTH.S300871.","journal-title":"Clin Ophthalmol"},{"issue":"10","key":"3459_CR6","doi-asserted-by":"publisher","first-page":"2186","DOI":"10.4103\/ijo.IJO_2046_19","volume":"68","author":"K Kaur","year":"2020","unstructured":"Kaur K, Kannusamy V, Mouttapa F, Gurnani B, Venkatesh R, Khadia A. To assess the accuracy of Plusoptix S12-C photoscreener in detecting amblyogenic risk factors in children aged 6 months to 6 years in remote areas of South India. Indian J Ophthalmol. 2020;68(10):2186\u20139. https:\/\/doi.org\/10.4103\/ijo.IJO_2046_19.","journal-title":"Indian J Ophthalmol"},{"issue":"5","key":"3459_CR7","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1080\/02713683.2018.1437453","volume":"43","author":"M Kinori","year":"2018","unstructured":"Kinori M, Molina I, Hernandez EO, et al. The PlusoptiX photoscreener and the Retinomax autorefractor as community-based screening devices for preschool children. Curr Eye Res. 2018;43(5):654\u20138. https:\/\/doi.org\/10.1080\/02713683.2018.1437453.","journal-title":"Curr Eye Res"},{"issue":"2","key":"3459_CR8","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1364\/josa.64.000240","volume":"64","author":"HC Howland","year":"1974","unstructured":"Howland HC, Howland B. Photorefraction: a technique for study of refractive state at a distance. J Opt Soc Am. 1974;64(2):240\u20139. https:\/\/doi.org\/10.1364\/josa.64.000240.","journal-title":"J Opt Soc Am"},{"issue":"2","key":"3459_CR9","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1111\/j.1755-3768.1979.tb00481.x","volume":"57","author":"K Kaakinen","year":"1979","unstructured":"Kaakinen K. A simple method for screening of children with strabismus, anisometropia or ametropia by simultaneous photography of the corneal and the fundus reflexes. Acta Ophthalmol (Copenh). 1979;57(2):161\u201371. https:\/\/doi.org\/10.1111\/j.1755-3768.1979.tb00481.x.","journal-title":"Acta Ophthalmol (Copenh)"},{"issue":"6","key":"3459_CR10","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1111\/j.1475-1313.2004.00233.x","volume":"24","author":"S Jainta","year":"2004","unstructured":"Jainta S, Jaschinski W, Hoormann J. Measurement of refractive error and accommodation with the photorefractor PowerRef II. Ophthalmic Physiol Opt. 2004;24(6):520\u20137. https:\/\/doi.org\/10.1111\/j.1475-1313.2004.00233.x.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"6","key":"3459_CR11","doi-asserted-by":"publisher","first-page":"e0126052","DOI":"10.1371\/journal.pone.0126052","volume":"10","author":"XR Yan","year":"2015","unstructured":"Yan XR, Jiao WZ, Li ZW, Xu WW, Li FJ, Wang LH. Performance of the Plusoptix A09 photoscreener in detecting amblyopia risk factors in Chinese children attending an eye clinic. PLoS One. 2015;10(6):e0126052. https:\/\/doi.org\/10.1371\/journal.pone.0126052. eCollection 2015.","journal-title":"PLoS One"},{"issue":"5","key":"3459_CR12","doi-asserted-by":"publisher","first-page":"306","DOI":"10.3928\/01913913-20180405-03","volume":"55","author":"K Teberik","year":"2018","unstructured":"Teberik K, Eski MT, Kaya M, Ankarali H. A comparison of three different photoscreeners in children. J Pediatr Ophthalmol Strabismus. 2018;55(5):306\u201311. https:\/\/doi.org\/10.3928\/01913913-20180405-03.","journal-title":"J Pediatr Ophthalmol Strabismus"},{"issue":"10","key":"3459_CR13","doi-asserted-by":"publisher","first-page":"1555","DOI":"10.4103\/ijo.IJO_1465_18","volume":"67","author":"V Saini","year":"2019","unstructured":"Saini V, Raina UK, Gupta A, et al. Comparison of Plusoptix S12R photoscreener with cycloplegic retinoscopy and autorefraction in pediatric age group. Indian J Ophthalmol. 2019;67(10):1555\u20139. https:\/\/doi.org\/10.4103\/ijo.IJO_1465_18.","journal-title":"Indian J Ophthalmol"},{"issue":"5","key":"3459_CR14","doi-asserted-by":"publisher","first-page":"276.e1","DOI":"10.1016\/j.jaapos.2019.05.017","volume":"23","author":"E Racano","year":"2019","unstructured":"Racano E, Alessi S, Pertile R. Comparison of 2Win and plusoptiX A12R refractometers with Retinomax handheld autorefractor keratometer. J AAPOS. 2019;23(5):276.e1-276.e5. https:\/\/doi.org\/10.1016\/j.jaapos.2019.05.017.","journal-title":"J AAPOS"},{"issue":"4","key":"3459_CR15","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1016\/j.jaapos.2016.04.006","volume":"20","author":"M Fogel-Levin","year":"2016","unstructured":"Fogel-Levin M, Doron R, Wygnanski-Jaffe T, Ancri O, Ben Zion I. A comparison of plusoptiX A12 measurements with cycloplegic refraction. J AAPOS. 2016;20(4):310\u20134. https:\/\/doi.org\/10.1016\/j.jaapos.2016.04.006.","journal-title":"J AAPOS"},{"issue":"1","key":"3459_CR16","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1038\/s41598-017-02246-6","volume":"7","author":"D Huang","year":"2017","unstructured":"Huang D, Chen X, Zhang X, et al. Pediatric vision screening using the plusoptiX A12C photoscreener in Chinese preschool children aged 3 to 4 years. Sci Rep. 2017;7(1):2041. https:\/\/doi.org\/10.1038\/s41598-017-02246-6.","journal-title":"Sci Rep"},{"issue":"7","key":"3459_CR17","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0254831","volume":"16","author":"C Al-Haddad","year":"2021","unstructured":"Al-Haddad C, El Moussawi Z, Hoyeck S, et al. Amblyopia risk factors among pediatric patients in a hospital-based setting using photoscreening. PLoS One. 2021;16(7): e0254831. https:\/\/doi.org\/10.1371\/journal.pone.0254831.","journal-title":"PLoS One"},{"issue":"2","key":"3459_CR18","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1097\/OPX.0b013e318031b09b","volume":"84","author":"SP Donahue","year":"2007","unstructured":"Donahue SP. Prescribing spectacles in children: a pediatric ophthalmologist\u2019s approach. Optom Vis Sci. 2007;84(2):110\u20134. https:\/\/doi.org\/10.1097\/OPX.0b013e318031b09b.","journal-title":"Optom Vis Sci"},{"issue":"1","key":"3459_CR19","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1136\/bjo.87.1.4","volume":"87","author":"KA Hutcheson","year":"2003","unstructured":"Hutcheson KA, Ellish NJ, Lambert SR. Weaning children with accommodative esotropia out of spectacles: a pilot study. Br J Ophthalmol. 2003;87(1):4\u20137. https:\/\/doi.org\/10.1136\/bjo.87.1.4.","journal-title":"Br J Ophthalmol"},{"key":"3459_CR20","doi-asserted-by":"publisher","first-page":"1487013","DOI":"10.1155\/2019\/148701","volume":"2019","author":"ET Yassa","year":"2019","unstructured":"Yassa ET, \u00dcnl\u00fc C. Comparison of Autorefraction and Photorefraction with and without Cycloplegia Using 1% Tropicamide in Preschool Children. J Ophthalmol. 2019;2019:1487013. https:\/\/doi.org\/10.1155\/2019\/148701.","journal-title":"J Ophthalmol"},{"issue":"3","key":"3459_CR21","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.optom.2017.09.001","volume":"11","author":"N Yazdani","year":"2018","unstructured":"Yazdani N, Sadeghi R, Momeni-Moghaddam H, Zarifmahmoudi L, Ehsaei A. Comparison of cyclopentolate versus tropicamide cycloplegia: A systematic review and meta-analysis. J Optom. 2018;11(3):135\u201343. https:\/\/doi.org\/10.1016\/j.optom.2017.09.001.","journal-title":"J Optom"},{"issue":"4","key":"3459_CR22","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1016\/j.jcrs.2004.10.068","volume":"31","author":"EM Hofmeister","year":"2005","unstructured":"Hofmeister EM, Kaupp SE, Schallhorn SC. Comparison of tropicamide and cyclopentolate for cycloplegic refractions in myopic adult refractive surgery patients. J Cataract Refract Surg. 2005;31(4):694\u2013700. https:\/\/doi.org\/10.1016\/j.jcrs.2004.10.068.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"3459_CR23","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1016\/j.ophtha.2020.03.004","volume":"127","author":"LB Wilson","year":"2020","unstructured":"Wilson LB, Melia M, Kraker RT, et al. Accuracy of Autorefraction in Children: A Report by the American Academy of Ophthalmology. Ophthalmology. 2020;127(9):1259\u201367. https:\/\/doi.org\/10.1016\/j.ophtha.2020.03.004.","journal-title":"Ophthalmology"},{"issue":"2","key":"3459_CR24","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jaapos.2012.11.008","volume":"17","author":"DI Silbert","year":"2013","unstructured":"Silbert DI, Matta NS, Andersen K. Plusoptix photoscreening may replace cycloplegic examination in select pediatric ophthalmology patients. J AAPOS. 2013;17(2):163\u20135. https:\/\/doi.org\/10.1016\/j.jaapos.2012.11.008.","journal-title":"J AAPOS"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03459-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-024-03459-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03459-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,19]],"date-time":"2024-04-19T07:03:49Z","timestamp":1713510229000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-024-03459-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,19]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3459"],"URL":"https:\/\/doi.org\/10.1186\/s12886-024-03459-w","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,19]]},"assertion":[{"value":"5 February 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study and data collection were performed in accordance with relevant guidelines and regulations and adhered to local laws and the Institutional Review Board approval standards. The research protocol was approved by the ethics committee of Guilan society of ophthalmology and was compliant with the principles of the declaration of Helsinki.Written informed consents were obtained from all patients\u2019 parents or legal guardians for participation in the study and publication of this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Information or images that could lead to identification of a study participant: not applicable","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"179"}}