{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T02:17:24Z","timestamp":1784859444496,"version":"3.55.0"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,22]],"date-time":"2024-07-22T00:00:00Z","timestamp":1721606400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,22]],"date-time":"2024-07-22T00:00:00Z","timestamp":1721606400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Medizinische Fakult\u00e4t Heidelberg der Universit\u00e4t Heidelberg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>The aim of this study was to analyze the causes and characteristics of IOL explantation within the first year after primary implantation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>In this retrospective, cross sectional database study, a database consisting of over 2500 IOL explants sent from 199 national and international doctors over the past 10 years was analyzed. All IOLs explanted within the first year after implantation were included in this analysis. Explants with insufficient information as well as phakic and Add-on IOLs were excluded. Main outcome measures were the reason for explantation, the time between implantation and explantation, as well as IOLs\u2019 and patients\u2019 characteristics. Additionally, the explanted IOLs were microscopically and histologically analyzed, as required.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Of all explanted IOLs from the database, 1.9% (<jats:italic>n<\/jats:italic>\u2009=\u200950) were explanted within the first year after implantation. The most frequent reasons for early IOL explantation were IOL dislocation (32%), visual intolerance (26%), opacification (20%), and intraoperative complications (16%). The time between implantation and explantation was the shortest in cases with intraoperative complications (1.5\u2009\u00b1\u20093.1 days), followed by IOL dislocation (90.9\u2009\u00b1\u2009103.9 days), visual intolerance (98.3\u2009\u00b1\u200986.5 days), opacifications (253.5\u2009\u00b1\u2009124.0 days) and other indications (249.7\u2009\u00b1\u2009124.0 days). Calcification of hydrophilic IOLs was the main type of opacification (80%). Notably, seven IOLs required immediate intraoperative exchange due to an intraoperative crack in the optic or a torn off haptic.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Indications for early IOL explantation were IOL dislocation, visual intolerance, opacification, and intraoperative complications. Especially intraoperative damages to the IOL and early calcification show a potential for improvement of affected IOLs and implantation systems.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12886-024-03570-y","type":"journal-article","created":{"date-parts":[[2024,7,22]],"date-time":"2024-07-22T08:01:54Z","timestamp":1721635314000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Early intraocular lens explantations: 10-year database analysis"],"prefix":"10.1186","volume":"24","author":[{"given":"Maximilian","family":"Friedrich","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyeck-Soo","family":"Son","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oliver","family":"Hassel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lilly","family":"Teich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor Aristide","family":"Augustin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd Uwe","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timur Mert","family":"Yildirim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,22]]},"reference":[{"issue":"12","key":"3570_CR1","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1097\/j.jcrs.0000000000000349","volume":"46","author":"J Goemaere","year":"2020","unstructured":"Goemaere J, Trigaux C, Denissen L, Dragnea D, Hua MT, Tassignon MJ, et al. Fifteen years of IOL exchange: indications, outcomes, and complications. J Cataract Refract Surg. 2020;46(12):1596\u2013603.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"3570_CR2","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1016\/S0039-6257(97)00140-9","volume":"42","author":"AN Carlson","year":"1998","unstructured":"Carlson AN, Stewart WC, Tso PC. Intraocular lens complications requiring removal or exchange. Surv Ophthalmol. 1998;42(5):417\u201340.","journal-title":"Surv Ophthalmol"},{"key":"3570_CR3","doi-asserted-by":"crossref","unstructured":"M\u00e4rker DA, Radeck V, Barth T, Helbig H, Scherer NCD. Long-term outcome and complications of IOL-Exchange. Clinical ophthalmology (Auckland, NZ). 2023;17:3243\u20138.","DOI":"10.2147\/OPTH.S436963"},{"issue":"11","key":"3570_CR4","doi-asserted-by":"publisher","first-page":"e186","DOI":"10.1016\/j.ophtha.2020.07.004","volume":"128","author":"GM Durr","year":"2021","unstructured":"Durr GM, Ahmed IIK. Intraocular lens complications: decentration, uveitis-glaucoma-hyphema syndrome, opacification, and refractive surprises. Ophthalmology. 2021;128(11):e186\u201394.","journal-title":"Ophthalmology"},{"issue":"5","key":"3570_CR5","doi-asserted-by":"publisher","first-page":"762","DOI":"10.5301\/ejo.5000168","volume":"22","author":"R Fern\u00e1ndez-Buenaga","year":"2012","unstructured":"Fern\u00e1ndez-Buenaga R, Alio JL, Mu\u00f1oz-Negrete FJ, Barraquer Compte RI, Alio-Del Barrio JL. Causes of IOL explantation in Spain. Eur J Ophthalmol. 2012;22(5):762\u20138.","journal-title":"Eur J Ophthalmol"},{"issue":"1","key":"3570_CR6","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/ICU.0000000000000719","volume":"32","author":"P Kanclerz","year":"2021","unstructured":"Kanclerz P, Yildirim TM, Khoramnia R. A review of late intraocular lens opacifications. Curr Opin Ophthalmol. 2021;32(1):31\u201344.","journal-title":"Curr Opin Ophthalmol"},{"issue":"7","key":"3570_CR7","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1016\/j.jcrs.2019.01.025","volume":"45","author":"JN Weindler","year":"2019","unstructured":"Weindler JN, \u0141abuz G, Yildirim TM, Tandogan T, Khoramnia R, Auffarth GU. The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens. J Cataract Refract Surg. 2019;45(7):1020\u20135.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3570_CR8","first-page":"372","volume":"6","author":"R Fern\u00e1ndez-Buenaga","year":"2017","unstructured":"Fern\u00e1ndez-Buenaga R, Ali\u00f3 JL. Intraocular lens explantation after cataract surgery: indications, results, and explantation techniques. Asia Pac J Ophthalmol (Phila). 2017;6(4):372\u201380.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"8","key":"3570_CR9","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1001\/archopht.1994.01090200043019","volume":"112","author":"MK Jensen","year":"1994","unstructured":"Jensen MK, Crandall AS, Mamalis N, Olson RJ. Crystallization on intraocular lens surfaces associated with the use of Healon GV. Arch Ophthalmol. 1994;112(8):1037\u201342.","journal-title":"Arch Ophthalmol"},{"issue":"2","key":"3570_CR10","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/S0002-9394(98)00076-2","volume":"126","author":"RJ Olson","year":"1998","unstructured":"Olson RJ, Caldwell KD, Crandall AS, Jensen MK, Huang SC. Intraoperative crystallization on the intraocular lens surface. Am J Ophthalmol. 1998;126(2):177\u201384.","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"3570_CR11","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1111\/j.1442-9071.1997.tb01279.x","volume":"25","author":"GA Lee","year":"1997","unstructured":"Lee GA, Dal Pra ML. Cracked acrylic intraocular lens requiring explantation. Aust N Z J Ophthalmol. 1997;25(1):71\u20133.","journal-title":"Aust N Z J Ophthalmol"},{"issue":"6","key":"3570_CR12","doi-asserted-by":"publisher","first-page":"1260","DOI":"10.1016\/j.jcrs.2005.04.004","volume":"31","author":"JL Chuah","year":"2005","unstructured":"Chuah JL, Rajesh CV. Intraoperative fracture of AMO clariflex silicone posterior chamber IOL. J Cataract Refractive Surg. 2005;31(6):1260\u20131.","journal-title":"J Cataract Refractive Surg"},{"issue":"7","key":"3570_CR13","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1038\/eye.2013.95","volume":"27","author":"R Fern\u00e1ndez-Buenaga","year":"2013","unstructured":"Fern\u00e1ndez-Buenaga R, Alio JL, P\u00e9rez-Ardoy AL, Larrosa-Quesada A, Pinilla-Cort\u00e9s L, Barraquer R, et al. Late in-the-bag intraocular lens dislocation requiring explantation: risk factors and outcomes. Eye (Lond). 2013;27(7):795\u2013801. quiz 2.","journal-title":"Eye (Lond)"},{"issue":"2","key":"3570_CR14","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.ophtha.2016.10.024","volume":"124","author":"O Kristianslund","year":"2017","unstructured":"Kristianslund O, R\u00e5en M, \u00d8stern AE, Drolsum L. Late in-the-bag intraocular lens dislocation: a randomized clinical trial comparing lens repositioning and lens exchange. Ophthalmology. 2017;124(2):151\u20139.","journal-title":"Ophthalmology"},{"issue":"4","key":"3570_CR15","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.ophtha.2023.10.021","volume":"131","author":"HS Son","year":"2024","unstructured":"Son HS, Chang DF, Li C, Liu L, Zafar S, Lum F, et al. Visual acuity outcomes and complications after intraocular lens exchange: an IRIS\u00ae registry (Intelligent research in sight) analysis. Ophthalmology. 2024;131(4):403\u201311.","journal-title":"Ophthalmology"},{"key":"3570_CR16","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.ajo.2017.12.016","volume":"187","author":"ED Bothun","year":"2018","unstructured":"Bothun ED, Cavalcante LCB, Hodge DO, Patel SV. Population-based incidence of intraocular lens exchange in Olmsted County, Minnesota. Am J Ophthalmol. 2018;187:80\u20136.","journal-title":"Am J Ophthalmol"},{"key":"3570_CR17","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1186\/s12886-015-0149-1","volume":"15","author":"T Tandogan","year":"2015","unstructured":"Tandogan T, Khoramnia R, Choi CY, Scheuerle A, Wenzel M, Hugger P, et al. Optical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study. BMC Ophthalmol. 2015;15:170.","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"3570_CR18","first-page":"20","volume":"46","author":"T Neuhann","year":"2020","unstructured":"Neuhann T, Yildirim TM, Son HS, Merz PR, Khoramnia R, Auffarth GU. Reasons for explantation, demographics, and material analysis of 200 intraocular lens explants. J Cataract Refract Surg. 2020;46(1):20\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"3570_CR19","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1007\/s00347-020-01075-9","volume":"117","author":"MS Bedar","year":"2020","unstructured":"Bedar MS, Kellner U. Clinical experience with the Clareon\u00ae IOL and the AutonoMe\u00ae implantation system. Der Ophthalmologe: Z Der Deutschen Ophthalmologischen Gesellschaft. 2020;117(11):1100\u20134.","journal-title":"Der Ophthalmologe: Z Der Deutschen Ophthalmologischen Gesellschaft"},{"issue":"2","key":"3570_CR20","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/S0886-3350(02)01457-8","volume":"29","author":"T Takeshita","year":"2003","unstructured":"Takeshita T, Yamada K, Tanihara H. Single-action implantation of a 3-piece acrylic intraocular lens with an injector. J Cataract Refract Surg. 2003;29(2):246\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"3570_CR21","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1055\/s-2001-18391","volume":"218","author":"Y Hesse","year":"2001","unstructured":"Hesse Y, Freissler KA, Lang GK. Scanning electron microscopic study of 12 lenses of two types of soft acrylic intraocular lenses. Klin Monatsbl Augenheilkd. 2001;218(10):682\u20137.","journal-title":"Klin Monatsbl Augenheilkd"},{"issue":"7","key":"3570_CR22","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.1016\/j.jcrs.2010.01.031","volume":"36","author":"IJ Khan","year":"2010","unstructured":"Khan IJ, Abbott J, Bhatnager AJ, Price NJ. Three-haptic intraocular lens for myopia: early results. J Cataract Refract Surg. 2010;36(7):1161\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"3570_CR23","first-page":"e38903","volume":"15","author":"C Evereklioglu","year":"2023","unstructured":"Evereklioglu C, Uysal Y, Sener H, S\u00f6nmez HK, Horozoglu F. The incidence of optic cracks or fractures during a foldable AcrySof or Acriva BB acrylic monofocal intraocular lens implantation via the manual monarch injector system with the cartridge in phacoemulsification surgery. Cureus. 2023;15(5):e38903.","journal-title":"Cureus"},{"issue":"4","key":"3570_CR24","doi-asserted-by":"publisher","first-page":"618","DOI":"10.1016\/j.ajo.2011.03.009","volume":"152","author":"SL Pueringer","year":"2011","unstructured":"Pueringer SL, Hodge DO, Erie JC. Risk of late intraocular lens dislocation after cataract surgery, 1980\u20132009: a population-based study. Am J Ophthalmol. 2011;152(4):618\u201323.","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"3570_CR25","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/j.ophtha.2006.09.017","volume":"114","author":"K Hayashi","year":"2007","unstructured":"Hayashi K, Hirata A, Hayashi H. Possible predisposing factors for in-the-bag and out-of-the-bag intraocular lens dislocation and outcomes of intraocular lens exchange surgery. Ophthalmology. 2007;114(5):969\u201375.","journal-title":"Ophthalmology"},{"issue":"8","key":"3570_CR26","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1055\/a-2074-9028","volume":"240","author":"R Khoramnia","year":"2023","unstructured":"Khoramnia R, Baur ID, Auffarth GU. Aetiology and management of IOL dislocations. Klin Monatsbl Augenheilkd. 2023;240(8):971\u201380.","journal-title":"Klin Monatsbl Augenheilkd"},{"issue":"4","key":"3570_CR27","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1038\/s41433-019-0585-x","volume":"34","author":"P Rudalevicius","year":"2020","unstructured":"Rudalevicius P, Lekaviciene R, Auffarth GU, Liutkeviciene R, Jasinskas V. Relations between patient personality and patients\u2018 dissatisfaction after multifocal intraocular lens implantation: clinical study based on the five factor inventory personality evaluation. Eye. 2020;34(4):717\u201324.","journal-title":"Eye"},{"issue":"5","key":"3570_CR28","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","volume":"37","author":"NE de Vries","year":"2011","unstructured":"de Vries NE, Webers CAB, Touwslager WRH, Bauer NJC, de Brabander J, Berendschot TT, et al. Dissatisfaction after implantation of multifocal intraocular lenses. J Cataract Refractive Surg. 2011;37(5):859\u201365.","journal-title":"J Cataract Refractive Surg"},{"issue":"4","key":"3570_CR29","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/j.jcrs.2007.11.040","volume":"34","author":"GJ Jin","year":"2008","unstructured":"Jin GJ, Merkley KH, Crandall AS, Jones YJ. Laser in situ keratomileusis versus lens-based surgery for correcting residual refractive error after cataract surgery. J Cataract Refract Surg. 2008;34(4):562\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"3570_CR30","doi-asserted-by":"publisher","first-page":"2094","DOI":"10.1016\/j.ophtha.2004.06.032","volume":"111","author":"IM Neuhann","year":"2004","unstructured":"Neuhann IM, Werner L, Izak AM, Pandey SK, Kleinmann G, Mamalis N, et al. Late postoperative opacification of a hydrophilic acrylic (hydrogel) intraocular lens: a clinicopathological analysis of 106 explants. Ophthalmology. 2004;111(11):2094\u2013101.","journal-title":"Ophthalmology"},{"issue":"1","key":"3570_CR31","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1111\/ceo.13650","volume":"48","author":"J Fern\u00e1ndez","year":"2020","unstructured":"Fern\u00e1ndez J, S\u00e1nchez-Garc\u00eda A, Rodr\u00edguez-Vallejo M, Pi\u00f1ero DP. Systematic review of potential causes of intraocular lens opacification. Clin Exp Ophthalmol. 2020;48(1):89\u201397.","journal-title":"Clin Exp Ophthalmol"},{"issue":"9","key":"3570_CR32","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1097\/j.jcrs.0000000000000553","volume":"47","author":"G \u0141abuz","year":"2021","unstructured":"\u0141abuz G, Yildirim TM, Khoramnia R, Son HS, Auffarth GU. Optical function of intraocular lenses in different opacification patterns: metrology analysis of 67 explants. J Cataract Refract Surg. 2021;47(9):1210\u20137.","journal-title":"J Cataract Refract Surg"},{"key":"3570_CR33","doi-asserted-by":"crossref","unstructured":"Son HS, \u0141abuz G, Khoramnia R, Yildirim TM, Choi CY, Knorz MC et al. Visualization of forward light scatter in opacified intraocular lenses and straylight assessment. Diagnostics (Basel). 2021;11(8).","DOI":"10.3390\/diagnostics11081512"},{"issue":"1","key":"3570_CR34","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s40662-021-00235-5","volume":"8","author":"G \u0141abuz","year":"2021","unstructured":"\u0141abuz G, Yildirim TM, Auffarth GU, Son HS, Khoramnia R. Laboratory evaluation of higher-order aberrations and light scattering in explanted opacified intraocular lenses. Eye Vis (Lond). 2021;8(1):14.","journal-title":"Eye Vis (Lond)"},{"key":"3570_CR35","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.ajo.2018.06.002","volume":"193","author":"TM Yildirim","year":"2018","unstructured":"Yildirim TM, Auffarth GU, \u0141abuz G, Bopp S, Son HS, Khoramnia R. Material analysis and optical quality assessment of opacified hydrophilic acrylic intraocular lenses after pars plana vitrectomy. Am J Ophthalmol. 2018;193:10\u20139.","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"3570_CR36","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1016\/j.jcrs.2018.01.033","volume":"44","author":"G \u0141abuz","year":"2018","unstructured":"\u0141abuz G, Yildirim TM, van den Berg T, Khoramnia R, Auffarth GU. Assessment of straylight and the modulation transfer function of intraocular lenses with centrally localized opacification associated with the intraocular injection of gas. J Cataract Refract Surg. 2018;44(5):615\u201322.","journal-title":"J Cataract Refract Surg"},{"key":"3570_CR37","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.ajo.2016.04.018","volume":"168","author":"SP Gartaganis","year":"2016","unstructured":"Gartaganis SP, Prahs P, Lazari ED, Gartaganis PS, Helbig H, Koutsoukos PG. Calcification of hydrophilic acrylic intraocular lenses with a hydrophobic surface: laboratory analysis of 6 cases. Am J Ophthalmol. 2016;168:68\u201377.","journal-title":"Am J Ophthalmol"},{"key":"3570_CR38","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/j.ajo.2017.04.024","volume":"179","author":"S Schrittenlocher","year":"2017","unstructured":"Schrittenlocher S, Penier M, Schaub F, Bock F, Cursiefen C, Bachmann B. Intraocular lens calcifications after (Triple-) descemet membrane endothelial keratoplasty. Am J Ophthalmol. 2017;179:129\u201336.","journal-title":"Am J Ophthalmol"},{"issue":"6","key":"3570_CR39","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1016\/j.jcrs.2016.02.047","volume":"42","author":"E M\u00f6nestam","year":"2016","unstructured":"M\u00f6nestam E, Behndig A. Change in light scattering caused by glistenings in hydrophobic acrylic intraocular lenses from 10 to 15 years after surgery. J Cataract Refract Surg. 2016;42(6):864\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"3570_CR40","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1016\/j.jcrs.2010.06.003","volume":"36","author":"L Werner","year":"2010","unstructured":"Werner L. Glistenings and surface light scattering in intraocular lenses. J Cataract Refract Surg. 2010;36(8):1398\u2013420.","journal-title":"J Cataract Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03570-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-024-03570-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03570-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,22]],"date-time":"2024-07-22T08:03:38Z","timestamp":1721635418000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-024-03570-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,22]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3570"],"URL":"https:\/\/doi.org\/10.1186\/s12886-024-03570-y","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,22]]},"assertion":[{"value":"15 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study solely involves laboratory analyses of IOL explants. No additional procedures on humans or animals were performed. The local Ethics Committee of the University of Heidelberg approved this study under the reference number: S-372\/2012. All patients gave written informed consent on the use of their anonymized data for scientific purposes. The study was performed in conformance with the tenets of the Declaration of Helsinki and adheres to all German federal and state laws.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"V.A.A. reports research grant from Kowa Co., Ltd. R.K. report grants, personal fees, and nonfinancial support from Johnson & Johnson Vision, Alcon Laboratories, Hoya Corp., Kowa Co., Ltd., Teleon, Physiol S.A., Sifi Medtech Srl, and Rayner Intraocular Lenses Ltd.; grants and personal fees from Oculus Optikger\u00e4te GmbH, Carl Zeiss Meditec AG, Heidelberg Engineering and Ophtec BV; and grants from Acufocus, Inc., outside the submitted work. G.U.A. reports lecture fees and research grants from Johnson & Johnson Vision, Alcon Laboratories, Carl Zeiss Meditec AG, Hoya Corp., Kowa Co., Ltd., Oculentis GmbH\/Teleon, Rayner Intraocular Lenses Ltd., Santen, Sifi Medtech Srl, and Biotech. T.M.Y. reports lecture fees from Alcon Laboratories, Johnson & Johnson Vision and Hoya Corp. and nonfinancial support from Johnson & Johnson Vision. For the remaining authors, no financial disclosures were declared.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"300"}}