{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T15:41:25Z","timestamp":1787499685590,"version":"build-2736575974"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,9,19]],"date-time":"2024-09-19T00:00:00Z","timestamp":1726704000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,9,19]],"date-time":"2024-09-19T00:00:00Z","timestamp":1726704000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-024-03658-5","type":"journal-article","created":{"date-parts":[[2024,9,19]],"date-time":"2024-09-19T05:02:13Z","timestamp":1726722133000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Comparison of measurements and calculated lens power using three biometers: a Scheimpflug tomographer with partial coherence interferometry and two swept source optical coherence tomographers"],"prefix":"10.1186","volume":"24","author":[{"given":"Robert Edward T.","family":"Ang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benedict L.","family":"Estolano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulo Hector C.","family":"Luz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Isabel N.","family":"Umali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle Marie Q.","family":"Araneta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emerson M.","family":"Cruz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,9,19]]},"reference":[{"issue":"1","key":"3658_CR1","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1097\/apo.0b013e31829df4bf","volume":"113","author":"G Davis","year":"2016","unstructured":"Davis G. The evolution of cataract surgery. Mo Med. 2016;113(1):58\u201362. https:\/\/doi.org\/10.1097\/apo.0b013e31829df4bf","journal-title":"Mo Med"},{"issue":"02","key":"3658_CR2","doi-asserted-by":"publisher","first-page":"94","DOI":"10.17925\/eor.2016.10.02.94","volume":"10","author":"M Turczynowska","year":"2016","unstructured":"Turczynowska M, Ko\u017alik-Nowakowska K, Gaca-Wysocka M, Grzybowski A. Effective ocular biometry and Intraocular Lens Power Calculation. Eur Ophthalmic Rev. 2016;10(02):94. https:\/\/doi.org\/10.17925\/eor.2016.10.02.94","journal-title":"Eur Ophthalmic Rev"},{"issue":"5","key":"3658_CR3","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1007\/s10792-018-0927-x","volume":"39","author":"M Muzyka-Wo\u017aniak","year":"2019","unstructured":"Muzyka-Wo\u017aniak M, Oleszko A. Comparison of anterior segment parameters and axial length measurements performed on a Scheimpflug device with biometry function and a reference optical biometer. Int Ophthalmol. 2019;39(5):1115\u201322. https:\/\/doi.org\/10.1007\/s10792-018-0927-x","journal-title":"Int Ophthalmol"},{"issue":"9","key":"3658_CR4","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","volume":"100","author":"A Akman","year":"2016","unstructured":"Akman A, Asena L, G\u00fcng\u00f6r SG. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500. Br J Ophthalmol. 2016;100(9):1201\u20135. https:\/\/doi.org\/10.1136\/bjophthalmol-2015-307779","journal-title":"Br J Ophthalmol"},{"issue":"1","key":"3658_CR5","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/j.jcrs.0000000000000373","volume":"47","author":"AD Fi\u015fu\u015f","year":"2021","unstructured":"Fi\u015fu\u015f AD, Hirnschall ND, Findl O. Comparison of 2 swept-source optical coherence tomography-based biometry devices. J Cataract Refract Surg. 2021;47(1):87\u201392. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000373","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3658_CR6","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.jcrs.2015.07.039","volume":"42","author":"KS Kunert","year":"2016","unstructured":"Kunert KS, Peter M, Blum M, et al. Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry. J Cataract Refract Surg. 2016;42(1):76\u201383. https:\/\/doi.org\/10.1016\/j.jcrs.2015.07.039","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3658_CR7","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1097\/j.jcrs.0000000000000483","volume":"47","author":"P Ta\u00f1\u00e1-Rivero","year":"2021","unstructured":"Ta\u00f1\u00e1-Rivero P, Aguilar-C\u00f3rcoles S, Tello-Elordi C, Pastor-Pascual F, Mont\u00e9s-Mic\u00f3 R. Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer. J Cataract Refract Surg. 2021;47(4):488\u201395. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000483","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3658_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-79674-4","volume":"11","author":"D Schiano-Lomoriello","year":"2021","unstructured":"Schiano-Lomoriello D, Hoffer KJ, Abicca I, Savini G. Repeatability of automated measurements by a new anterior segment optical coherence tomographer and biometer and agreement with standard devices. Sci Rep. 2021;11(1):1\u20137. https:\/\/doi.org\/10.1038\/s41598-020-79674-4","journal-title":"Sci Rep"},{"issue":"12 12","key":"3658_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0244590","volume":"15","author":"KY Kim","year":"2020","unstructured":"Kim KY, Choi GS, Kang MS, Kim US. Comparison study of the axial length measured using the new swept-source optical coherence tomography ANTERION and the partial coherence interferometry IOL Master. PLoS ONE. 2020;15(12 12):1\u201311. https:\/\/doi.org\/10.1371\/journal.pone.0244590","journal-title":"PLoS ONE"},{"issue":"9","key":"3658_CR10","doi-asserted-by":"publisher","first-page":"931","DOI":"10.4103\/0301-4738.143930","volume":"62","author":"S Hui","year":"2014","unstructured":"Hui S, Yi L. Comparison of two optical biometers in intraocular lens power calculation. Indian J Ophthalmol. 2014;62(9):931\u20134. https:\/\/doi.org\/10.4103\/0301-4738.143930","journal-title":"Indian J Ophthalmol"},{"issue":"8","key":"3658_CR11","doi-asserted-by":"publisher","first-page":"1809","DOI":"10.1007\/s10792-018-1006-z","volume":"39","author":"A Ortiz","year":"2019","unstructured":"Ortiz A, Galvis V, Tello A, et al. Comparison of three optical biometers: IOLMaster 500, Lenstar LS 900 and Aladdin. Int Ophthalmol. 2019;39(8):1809\u201318. https:\/\/doi.org\/10.1007\/s10792-018-1006-z","journal-title":"Int Ophthalmol"},{"issue":"6","key":"3658_CR12","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1177\/1120672118771844","volume":"28","author":"JMM Pereira","year":"2018","unstructured":"Pereira JMM, Neves A, Alfaiate P, Santos M, Arag\u00e3o H, Sousa JC. Lenstar\u00ae LS 900 vs Pentacam\u00ae-AXL: comparative study of ocular biometric measurements and intraocular lens power calculation. Eur J Ophthalmol. 2018;28(6):645\u201351. https:\/\/doi.org\/10.1177\/1120672118771844","journal-title":"Eur J Ophthalmol"},{"key":"3658_CR13","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ajo.2017.02.027","volume":"178","author":"M Shajari","year":"2017","unstructured":"Shajari M, Cremonese C, Petermann K, Singh P, M\u00fcller M, Kohnen T. Comparison of axial length, corneal curvature, and Anterior Chamber depth measurements of 2 recently, Introduced devices to a known Biometer. Am J Ophthalmol. 2017;178:58\u201364. https:\/\/doi.org\/10.1016\/j.ajo.2017.02.027","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"3658_CR14","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1007\/s40123-018-0122-1","volume":"7","author":"N Hirnschall","year":"2018","unstructured":"Hirnschall N, Varsits R, Doeller B, Findl O. Enhanced penetration for axial length measurement of eyes with dense cataracts using swept source Optical Coherence Tomography: a consecutive observational study. Ophthalmol Ther. 2018;7(1):119\u201324. https:\/\/doi.org\/10.1007\/s40123-018-0122-1","journal-title":"Ophthalmol Ther"},{"issue":"4","key":"3658_CR15","doi-asserted-by":"publisher","first-page":"041211","DOI":"10.1117\/1.2773728","volume":"12","author":"B Pova\u017eay","year":"2007","unstructured":"Pova\u017eay B, Hermann B, Unterhuber A, et al. Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients. J Biomed Opt. 2007;12(4):041211. https:\/\/doi.org\/10.1117\/1.2773728","journal-title":"J Biomed Opt"},{"issue":"5","key":"3658_CR16","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1016\/j.clae.2017.03.007","volume":"40","author":"S Sel","year":"2017","unstructured":"Sel S, Stange J, Kaiser D, Kiraly L. Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements. Contact Lens Anterior Eye. 2017;40(5):318\u201322. https:\/\/doi.org\/10.1016\/j.clae.2017.03.007","journal-title":"Contact Lens Anterior Eye"},{"issue":"9","key":"3658_CR17","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1097\/j.jcrs.0000000000000237","volume":"46","author":"MA Henriquez","year":"2020","unstructured":"Henriquez MA, Z\u00fa\u00f1iga R, Camino M, Camargo J, Ruiz-Montenegro K, Izquierdo L. Effectiveness and agreement of 3 optical biometers in measuring axial length in the eyes of patients with mature cataracts. J Cataract Refract Surg. 2020;46(9):1222\u20138. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000237","journal-title":"J Cataract Refract Surg"},{"key":"3658_CR18","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/j.ajo.2016.06.020","volume":"169","author":"P \u00d6zyol","year":"2016","unstructured":"\u00d6zyol P, \u00d6zyol E. Agreement between swept-source Optical Biometry and Scheimpflug-based Topography measurements of Anterior Segment parameters. Am J Ophthalmol. 2016;169:73\u20138. https:\/\/doi.org\/10.1016\/j.ajo.2016.06.020","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"3658_CR19","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.jcrs.2010.08.044","volume":"37","author":"J Huang","year":"2011","unstructured":"Huang J, Pesudovs K, Wen D, et al. Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry. J Cataract Refract Surg. 2011;37(2):341\u20138. https:\/\/doi.org\/10.1016\/j.jcrs.2010.08.044","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"3658_CR20","doi-asserted-by":"publisher","first-page":"187","DOI":"10.4103\/picr.PICR_123_17","volume":"8","author":"P Ranganathan","year":"2017","unstructured":"Ranganathan P, Pramesh C, Aggarwal R. Common pitfalls in statistical analysis: measures of agreement. Perspect Clin Res. 2017;8(4):187\u201391. https:\/\/doi.org\/10.4103\/picr.PICR_123_17","journal-title":"Perspect Clin Res"},{"issue":"11","key":"3658_CR21","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1016\/j.jcrs.2008.07.012","volume":"34","author":"DF Chang","year":"2008","unstructured":"Chang DF. Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses. J Cataract Refract Surg. 2008;34(11):1842\u20137. https:\/\/doi.org\/10.1016\/j.jcrs.2008.07.012","journal-title":"J Cataract Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03658-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-024-03658-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-024-03658-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,19]],"date-time":"2024-09-19T05:04:33Z","timestamp":1726722273000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-024-03658-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,19]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3658"],"URL":"https:\/\/doi.org\/10.1186\/s12886-024-03658-5","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,19]]},"assertion":[{"value":"29 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 August 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 September 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"In compliance with institutional guidelines for research involving human subjects, the St. Frances Cabrini Medical Center-Asian Eye Institute (SCMC-AEI) Ethics Review Committee has officially approved the study protocol and waived the need to obtain participants\u2019 informed consent. The decision was made on the basis of the study\u2019s retrospective design, low participant risk, and use of anonymized data. The decision was made after a careful evaluation of the research protocol and ethical issues, with a strong emphasis on protecting participant rights and welfare. All procedures were carried out in complete conformity to ethical norms and guidelines.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"410"}}