{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T06:49:56Z","timestamp":1794293396635,"version":"4.9.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T00:00:00Z","timestamp":1741737600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T00:00:00Z","timestamp":1741737600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>This study evaluated the agreement of the ocular parameters obtained with the two optical biometers, the IOLMaster 700 and the Galilei G6 Lens Professional.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Patients and methods<\/jats:title>\n            <jats:p>A comparative prospective study was conducted on 159 eyes of 91 adult patients using the IOLMaster 700 and Galilei G6 devices by a single examiner. Agreement between ocular biometric parameters: white-to-white (WTW) distance, keratometry (flat (K1) and steep (K2), mean (Km)) of anterior, posterior, and total corneal surfaces, central corneal thickness (CCT), anterior chamber depth (ACD), and axial length (AL) were assessed using Bland-Altman analysis. Keratometry measurements were further transformed into power vector components J0 and J45 for astigmatism analysis. Clinically significant differences were defined as deviations in biometric parameters translating to differences of 0.25 D or more in refractive outcomes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Statistically and clinically significant difference was identified for ACD (mean difference: -0.15\u00a0mm), posterior corneal metrics: K1 (0.39 D), K2 (0.42 D), Km (0.41 D) and J0 (0.05 D) and total corneal metrics: K1 (0.95 D), K2 (0.91 D), Km (0.93 D) and J0 (0.13 D). No significant differences were found for J45 components of posterior and total K, WTW, CCT, and AL measurements.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The difference in measurements of anterior chamber depth (ACD), posterior K, and total K metrics are clinically significant making the two devices are clinically significant and not interchangeable. These variation in metrics can impact the refractive outcomes of refractive and cataract surgery with toric IOLs.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12886-025-03916-0","type":"journal-article","created":{"date-parts":[[2025,3,12]],"date-time":"2025-03-12T15:54:32Z","timestamp":1741794872000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Agreement between swept-source OCT and Scheimpflug biometers in ocular measurements"],"prefix":"10.1186","volume":"25","author":[{"given":"Cameron","family":"McLintock","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"McKelvie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hamed","family":"Niyazmand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samir","family":"Uprety","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,12]]},"reference":[{"issue":"10","key":"3916_CR1","doi-asserted-by":"publisher","first-page":"e0223114","DOI":"10.1371\/JOURNAL.PONE.0223114","volume":"14","author":"CM Yang","year":"2019","unstructured":"Yang CM, Lim DH, Kim HJ, Chung TY. Comparison of two swept-source optical coherence tomography biometers and a partial coherence interferometer. PLoS ONE. 2019;14(10):e0223114. https:\/\/doi.org\/10.1371\/JOURNAL.PONE.0223114.","journal-title":"PLoS ONE"},{"issue":"5","key":"3916_CR2","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1007\/S00417-020-05046-3","volume":"259","author":"A Levron","year":"2021","unstructured":"Levron A, El Chehab H, Agard E, Chudzinski R, Billant J, Dot C. Impact of measured total keratometry versus anterior keratometry on the refractive outcomes of the AT TORBI 709-MP toric intraocular lens. Graefes Arch Clin Exp Ophthalmol. 2021;259(5):1199\u2013207. https:\/\/doi.org\/10.1007\/S00417-020-05046-3.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"3","key":"3916_CR3","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1097\/OPX.0000000000000799","volume":"93","author":"MC Shin","year":"2016","unstructured":"Shin MC, Chung SY, Hwang HS, Han KE. Comparison of two optical biometers. Optom Vis Sci. 2016;93(3):259\u201365.","journal-title":"Optom Vis Sci"},{"issue":"2","key":"3916_CR4","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1177\/11206721221143160","volume":"33","author":"C McLintock","year":"2023","unstructured":"McLintock C, Niyazmand H, Seo S, et al. Agreement between a new swept-source ocular coherence tomography and a Placido disc-dual Scheimpflug ocular biometric devices. Eur J Ophthalmol. 2023;33(2):905\u201311. https:\/\/doi.org\/10.1177\/11206721221143160.","journal-title":"Eur J Ophthalmol"},{"key":"3916_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-031-50666-6_27","volume-title":"GALILEI G6 Lens Professional","author":"G Schmid","year":"2024","unstructured":"Schmid G. GALILEI G6 Lens Professional. Cham: Springer International Publishing; 2024. https:\/\/doi.org\/10.1007\/978-3-031-50666-6_27."},{"issue":"9","key":"3916_CR6","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1097\/ICO.0000000000000480","volume":"34","author":"R Yagc","year":"2015","unstructured":"Yagc R, Kulak AE, G\u00fcler E, Tenlik A, G\u00fcraga\u00e7 FB, Hepsen IF. Comparison of anterior segment measurements with a dual Scheimpflug Placido corneal topographer and a new partial coherence interferometer in keratoconic eyes. Cornea. 2015;34(9):1012\u20138.","journal-title":"Cornea"},{"issue":"1","key":"3916_CR7","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.jcrs.2016.11.033","volume":"43","author":"BV Ventura","year":"2017","unstructured":"Ventura BV, Ventura MC, Wang L, Koch DD, Weikert MP. Comparison of biometry and intraocular lens power calculation performed by a new optical biometry device and a reference biometer. J Cataract Refract Surg. 2017;43(1):74\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"3916_CR8","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1097\/j.jcrs.0000000000000237","volume":"46","author":"MA Henriquez","year":"2020","unstructured":"Henriquez MA, Z\u00fa\u00f1iga R, Camino M, Camargo J, Ruiz-Montenegro K, Izquierdo L. Effectiveness and agreement of 3 optical biometers in measuring axial length in the eyes of patients with mature cataracts. J Cataract Refract Surg. 2020;46(9):1222\u20138. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000237.","journal-title":"J Cataract Refract Surg"},{"key":"3916_CR9","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/1516395","author":"S Jung","year":"2017","unstructured":"Jung S, Chin HS, Kim NR, Kang W, Lee J, Won J. Comparison of repeatability and agreement between swept-source Optical Biometry and Dual-Scheimpflug Topography. J Ophthalmol Published Online. 2017. https:\/\/doi.org\/10.1155\/2017\/1516395.","journal-title":"J Ophthalmol Published Online"},{"issue":"12","key":"3916_CR10","doi-asserted-by":"publisher","first-page":"2677","DOI":"10.1007\/S00417-019-04443-7","volume":"257","author":"S Srivannaboon","year":"2019","unstructured":"Srivannaboon S, Chirapapaisan C. Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery. Graefes Arch Clin Exp Ophthalmol. 2019;257(12):2677\u201382. https:\/\/doi.org\/10.1007\/S00417-019-04443-7.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"12","key":"3916_CR11","doi-asserted-by":"publisher","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","volume":"38","author":"DD Koch","year":"2012","unstructured":"Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg. 2012;38(12):2080\u20137. https:\/\/doi.org\/10.1016\/j.jcrs.2012.08.036.","journal-title":"J Cataract Refract Surg"},{"key":"3916_CR12","doi-asserted-by":"publisher","unstructured":"Tomidokoro A, Oshika T, Amano S, Higaki S, Maeda N, Miyata K. Changes in anterior and posterior corneal curvatures in keratoconus. Ophthalmology. 2000;107(7). https:\/\/doi.org\/10.1016\/S0161-6420(00)00159-7.","DOI":"10.1016\/S0161-6420(00)00159-7"},{"issue":"6","key":"3916_CR13","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/00006324-199706000-00019","volume":"74","author":"LN Thibos","year":"1997","unstructured":"Thibos LN, Wheeler W, Horner D. Power vectors: an application of Fourier analysis to the description and statistical analysis of refractive error. Optom Vis Sci. 1997;74(6):367\u201375.","journal-title":"Optom Vis Sci"},{"issue":"1","key":"3916_CR14","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.ajo.2013.01.029","volume":"156","author":"AZ Crawford","year":"2013","unstructured":"Crawford AZ, Patel DV, McGhee CN. Comparison and repeatability of keratometric and corneal power measurements obtained by Orbscan II, Pentacam, and Galilei corneal tomography systems. Am J Ophthalmol. 2013;156(1):53\u201360.","journal-title":"Am J Ophthalmol"},{"issue":"12","key":"3916_CR15","doi-asserted-by":"publisher","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","volume":"38","author":"DD Koch","year":"2012","unstructured":"Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg. 2012;38(12):2080\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"3916_CR16","doi-asserted-by":"publisher","first-page":"1107","DOI":"10.1097\/j.jcrs.0000000000000942","volume":"48","author":"C Mclintock","year":"2022","unstructured":"Mclintock C, Niyazmand H, Seo S, Barrett G, Nilagiri VK, Mckelvie J. Agreement between 2 SS-OCT biometry devices. J Cataract Refract Surg. 2022;48(10):1107\u201312. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000942.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"3916_CR17","doi-asserted-by":"publisher","first-page":"1652","DOI":"10.1097\/j.jcrs.0000000000000327","volume":"46","author":"L Wang","year":"2020","unstructured":"Wang L, Cao D, Vilar C, Koch DD. Posterior and total corneal astigmatism measured with optical coherence tomography-based biometer and dual Scheimpflug analyzer. J Cataract Refract Surg. 2020;46(12):1652\u20138. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000327.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"3916_CR18","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/j.jcrs.0000000000000373","volume":"47","author":"AD Fi\u015fu\u015f","year":"2021","unstructured":"Fi\u015fu\u015f AD, Hirnschall ND, Findl O. Comparison of 2 swept-source optical coherence tomography\u2013based biometry devices. J Cataract Refract Surg. 2021;47(1):87\u201392.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"3916_CR19","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1097\/j.jcrs.0000000000001320","volume":"50","author":"FM Wagner","year":"2024","unstructured":"Wagner FM, Hoffmann P, Preu\u00dfner PR. Accuracy comparison of tomography devices for ray tracing\u2013based intraocular lens calculation. J Cataract Refract Surg. 2024;50(2):110\u20135. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001320.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"3916_CR20","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1600-0420.2007.00879.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand. 2007;85(5):472\u201385. https:\/\/doi.org\/10.1111\/j.1600-0420.2007.00879.x.","journal-title":"Acta Ophthalmol Scand"},{"key":"3916_CR21","doi-asserted-by":"crossref","unstructured":"Yu J, Wen D, Zhao J et al. Comprehensive comparisons of ocular biometry: a network-based big data analysis. Eye Vis. 2023;10(1).","DOI":"10.1186\/s40662-022-00320-3"},{"key":"3916_CR22","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1080\/17434440.2021.2012448","volume":"18","author":"R Mazur","year":"2021","unstructured":"Mazur R, Wylegala A, Wylegala E, Dobrowolski D. Comparative analysis of measurements of the anterior segment and the axial length parameters of the eyeball obtained with optical and ultrasound technique. Med Devices. 2021;18:1245\u201353. https:\/\/doi.org\/10.1080\/17434440.2021.2012448.","journal-title":"Med Devices"},{"issue":"11","key":"3916_CR23","doi-asserted-by":"publisher","first-page":"e94","DOI":"10.1016\/j.ophtha.2020.08.010","volume":"128","author":"JX Kane","year":"2021","unstructured":"Kane JX, Chang DF. Intraocular lens power formulas, biometry, and intraoperative aberrometry: a review. Ophthalmol. 2021;128(11):e94\u2013114.","journal-title":"Ophthalmol"},{"issue":"1","key":"3916_CR24","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.sjopt.2011.11.002","volume":"26","author":"ME Wilson","year":"2012","unstructured":"Wilson ME, Trivedi RH. Axial length measurement techniques in pediatric eyes with cataract. Saudi J Ophthalmol. 2012;26(1):13\u20137.","journal-title":"Saudi J Ophthalmol"},{"key":"3916_CR25","doi-asserted-by":"publisher","unstructured":"Savini G, Hoffer KJ. Intraocular lens power calculation in eyes with previous corneal refractive surgery. Eye Vis. 2018;5(1). https:\/\/doi.org\/10.1186\/s40662-018-0110-5.","DOI":"10.1186\/s40662-018-0110-5"},{"key":"3916_CR26","doi-asserted-by":"publisher","unstructured":"Itoi M, Kitazawa K, Yokota I, et al. Anterior and posterior ratio of corneal surface areas: a novel index for detecting early stage keratoconus. PLoS ONE. 2020;15(4). https:\/\/doi.org\/10.1371\/journal.pone.0231074.","DOI":"10.1371\/journal.pone.0231074"},{"key":"3916_CR27","doi-asserted-by":"publisher","unstructured":"Wang Z, Song Y, Yang W, et al. Comparing Standard Keratometry and Total Keratometry before and after myopic corneal refractive surgery with a swept-source OCT biometer. Front Med (Lausanne). 2022;9. https:\/\/doi.org\/10.3389\/fmed.2022.928027.","DOI":"10.3389\/fmed.2022.928027"},{"key":"3916_CR28","doi-asserted-by":"publisher","unstructured":"Moshirfar M, Tenney S, McCabe S, Schmid G. Repeatability and reproducibility of the galilei G6 and its agreement with the pentacam\u00ae AXL in optical biometry and corneal tomography. Expert Rev Med Devices. 2022;19(4). https:\/\/doi.org\/10.1080\/17434440.2022.2075725.","DOI":"10.1080\/17434440.2022.2075725"},{"issue":"5","key":"3916_CR29","doi-asserted-by":"publisher","first-page":"347","DOI":"10.3928\/1081597X-20230202-02","volume":"39","author":"N Mart\u00ednez-Albert","year":"2023","unstructured":"Mart\u00ednez-Albert N, Nieto-Fern\u00e1ndez JC, Garc\u00eda-Marqu\u00e9s JV. Keratometry Agreement between two swept-source OCT devices in healthy and post-refractive surgery eyes. J Refract Surg. 2023;39(5):347\u201353. https:\/\/doi.org\/10.3928\/1081597X-20230202-02.","journal-title":"J Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-03916-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-03916-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-03916-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,13]],"date-time":"2025-03-13T00:59:02Z","timestamp":1741827542000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-03916-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,12]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["3916"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-03916-0","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,12]]},"assertion":[{"value":"26 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved and carried out in accordance with the Metro South Human Research Ethics Committee approval and followed the tenets of the Declaration of Helsinki. Prior to testing, each participant was informed about the purpose and procedures of the study, and written informed consent was obtained.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"127"}}